A B C D E F: Date: Signatures
A B C D E F: Date: Signatures
A B C D E F: Date: Signatures
C9
+260VDC
330mV
RMS
+275VDC +315VDC
470pF R8 R14
5.5Vp-p
500V
2 CW HI C4
10K
2W
10K
2W
2
250K L VTL-5C6 R60 9-PIN
10 C8 EL84
P2 R41 R76 450V 10 J17
10K 7
450V 1/2W R59 OUTPUT
475K 221K R11
7.65V 82.5K 1% 9 TRANSFORMER 15.5V
1/2W 1/2W 1/2W 2 100 RMS
S4 1% R74 1%
RMS
3 P/N 94-754-01
TO HDR SHT 2 1% 4 5 2W J6 43.5Vp-p
PRESENCE F -12.9V 62.5Vp-p
220 SEND
TO HDR SHT 2
OC3 1/2W 215VDC C13 F1 F2
R13 I I PRE_SEND R21
33.2K C46
1/2W
C28
A 12/10/03 INITIAL ISSUE
.22
50V REV Date DESCRIPTION Ecr(s)/Ecn(s) Chgd By Appvd by Date
CAUTION:
THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL. THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO
ST. LOUIS MUSIC, INC
TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL. DO NOT PERFORM ANY SERVICING BEYOND Signatures: Date:
THAT EXPLAINED IN THE OPERATING INSTRUCTIONS.
Drawn: WFB 12/10/03
4 NOTE: NOT SPLIT TEST POINT BUBBLE = CLEAN & DIRTY
Power Table
1901 Congressional, St. Louis, MO 63146
First Used On:
4
NOTES: Checked:
RefDes +14.7V -14.7V
1) CAUTION: SHOCK HAZARD!! Released:
THIS UNIT CONTAINS HAZARDOUS VOLTAGE. DISCONNECT POWER IC1 & IC2 8 4
AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE Drawing Title:
TOUCHING INTERNAL PARTS. NOTE: SPLIT TEST POINT BUBBLE Plot Date: Thu Jan 29, 2004 Drawing Size: C
2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL. CLEAN=TOP RMS VOLTS ( NO WAVE FORM ) Plot Time: Drawing Type: Schematic
PWA - TUBE GUITAR AMP
CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL. DIRTY=BOTTOM p-p VOLTS ( SEE WAVEFORM )
3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE Class Code: NONE Drawing Number:
Tolerance:
AND 10 MEGOHM DIGITAL VOLTMETER. DC VOLTS
Sheet 1 of 2
07S677
A B C D E F
A B C D
R49 R51
+12.9V
10 10
2W 2W
J28
POWER XMFR D7 +16.5V
R46
1 +14.7V 1
J20 240VAC J23 1N4002 150
1
100V PIV C23
230VAC 2 2200 C25
J14 FC1 F1 FC2 J18 J21 J29 D8 25V 47 C44
115VAC 3 16V 1000
LINE
FUSE CLIP
100VAC 3 16V
100/120V
FUSE CLIP POWER J22 4 1N4002
LINE 1-1/2 A SB SWITCH 2 100V PIV
AC 230/240V 5
LINE GND
1.6A SB CERAMIC
CORD C17 1 100V PIV
NEUT
.0033 1N4002 C26 C43
C24 47 1000
250V 16V
J15 2200 16V
D9 25V
NEUT
D10 R47
S2 C18 -14.7V
S3 150
BOOST SWITCH .0033 1N4002
CHANNEL SW 250V 100V PIV -16.5V
2 I I I I 3 F2 R50 R52 2
6.3VAC -12.9V
C C
2 10 10
C C 2W 2W
-12.9V 1 F1
J24 +320VDC
O O O O BOOST C32 STANDBY
+16.5V J39 SWITCH
.001 J40
R63 R64 1KV
15K 4.7K J25 D3
R73
1.5K R65
J31 FOOTSWITCH Q2 A 1N4007
RING
D12 D13 1M D5 1KV PIV C33 R26
C34 1N4007 .001
11 11 ON = -11.5VDC .001 D4
RING_SW OFF = 0VDC 1KV PIV 1N4007 150K
1N914 1N914 1KV 1KV 2W
TIP_SW
10 10 75V PIV 75V PIV 2N5087 D6 1KV PIV
9 9 D11 C19
TIP
1N746ARL 1N4007
8 8
3.3V 1KV PIV
3 SLVE_SW
7 7
C35
100 3
SLEEVE 450V
-12.9V J26 .001
6 6
1KV
SWITCH GROUND 5 5 PRE_SEND CHAN_SEL CH SELECT
4 4 RETURN
+16.5V R70
SEND R68 R66 33K
3 3 15K
ON JACK BOARD 4.7K
CLEAN = -12.9VDC
BREAK-OFF PC BOARD 2 2 B
R69 DIRTY = -2.7VDC
1 1 1.5K R67
J35 J36 C50
100K Q4
10 2N5087 POWER
CAUTION:
PREAMP GROUND D14 D16 35V
THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL. F2 A 12/10/03 INITIAL ISSUE
TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED
REV Date DESCRIPTION Ecr(s)/Ecn(s) Chgd By Appvd by Date
SERVICE PERSONNEL. DO NOT PERFORM ANY SERVICING BEYOND
1N914 1N914 Q3
THAT EXPLAINED IN THE OPERATING INSTRUCTIONS.
75V PIV 75V PIV 2N5087 F1 THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO ST. LOUIS MUSIC, INC
D CLEAN = 0VDC
NOTES: C51 DIRTY = -11.8VDC J9
Signatures: Date:
4 1) CAUTION: SHOCK HAZARD!!
D15
1N746ARL Drawn: WFB 12/10/03 1901 Congressional, St. Louis, MO 63146
4
THIS UNIT CONTAINS HAZARDOUS VOLTAGE. DISCONNECT POWER 3.3V 10 Checked: First Used On:
AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE 35V
TOUCHING INTERNAL PARTS. Released:
2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL. Plot Date: Thu Jan 29, 2004 Drawing Size: B Drawing Title:
PWA - TUBE GUITAR AMP
CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL. Plot Time: 12:07:07 Drawing Type: Schematic
3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE
Tolerance: Class Code: NONE Drawing Number:
AND 10 MEGOHM DIGITAL VOLTMETER.
Sheet 2 of 2 07S677
A B C D
A B C D
J28
FC1 F1
J8
FC2
J6
J23
J20
R24
R25
R59
J14
J18
FOOTSWITCH
J21
1 R9
1
J31
C17
J15
J22
C18
J17 J4 J5 J16 C16
C15
EL84 EL84 EL84 EL84
C19
R23
J7
R21
J35
R60
J24 1
1
R57
JW11
JW12
J40
C35
C30 C39
SEND
J19
D6
C33
R77
R17
R22
C4 R8 R14 R58
C7 J25
R19
D4 D5
R34 C8 D3
J39
C24
R42
C23
R11
D12
C49
R15
R40
C13
R7
C14
R2
C6 R63
J30
D11
2 R55 1
J36 D15
D14
R73 1 J29 2
R69
J11
J12
D16 Q3 D10
C29 R68 C51
R30 D9
Q2
R39
C50
Q4
C25
OC2
R33
R6
R47
R20
R43
C21
D1
R46
R32
C1 {Label} C5 {Label} {Label} R70 R67
D7
R52
R12
SPEAKER
J33
C31
C26
R50
R10
C38 R29
J32
W1
R78
C46
R79
J13
D2
R44
R37
W2
J27
R28 C27
C22
R3
OC5 C36
R18
R16
J34 C48 OC1 R13
C2
C3
R35
C41
R4
R27
R62
C28
Q1
C55
G S D
R49
C53
R51
INPUT R38 R41
W1 R76
C10
C11
R31
R5
R75
R74
R48 C54
R65
R64
J10 W2
R1
R45
C9
C52
P7 P1 P2 P3 P4 P5 P6
3 VOLUME GAIN HI MID LOW LEVEL REVERB 3
BOOST SWITCH
Plot Date: Thu Jan 29, 2004 Drawing Size: B Drawing Title:
CAUTION:
THIS ASSEMBLY DRAWING IS PROVIDED FOR USE BY QUALIFIED PERSONNEL. Drawing Type:
PWA - GUITAR AMP
Plot Time: 12:00:34 ASSEMBLY
TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
DO NOT PERFORM ANY SERVICING BEYOND THAT EXPLAINED IN THE OPERATING INSTRUCTIONS. Tolerance: Class Code: NONE Drawing Number:
07-677
Sheet 1 of 1
A B C D
A 1/29/04 INITIAL ISSUE
Rev. Date DESC. ECR(s)/ECN(s) Chgd by Appvd by DATE
THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO
ST. LOUIS MUSIC, INC.
SLM Electronics
Signatures: Date: 1901 Congressional Drive, St. Louis, MO 63146
Drawn: WFB 1/28/04
Checked: First Used On:
Released:
Tolerance: Drawing Size: A Drawing Title: PWA - 30W TUBE
Drawing Type: PL
Class Code: Drawing No.: 07-677-PL
Scale: N/A
DOCUMENT No. :
Section 1 of 1 Page 1 of 5
DOCUMENT No. :
Section 1 of 1 Page 2 of 5
DOCUMENT No. :
Section 1 of 1 Page 3 of 5
DOCUMENT No. :
Section 1 of 1 Page 4 of 5
DOCUMENT No. :
Section 1 of 1 Page 5 of 5