Owner's Manual
Original Instructions
◆ Never install the wired remote controller in highly humid environments or expose to direct
sunlight.
◆ Never drop, shake, toss or frequently disassemble the wired remote controller or the wireless
remote controller.
◆ Never operate the wired remote controller and the wireless remote controller with wet hands.
◆ Do not remove or install the wired controller by yourself. If you have questions, please contact
your local licensed HVAC technician.
◆ This wired controller is compatible with several kinds of units.
Some functions of the wired controller are not available for certain units,IRU more details please
refer to the owner’s manual of unit. Selecting an unavailable function will do nothing and will not
affect unit’s operation.
◆ The wired controller is universal. The remote receiver is either in the indoor unit or in the wired
controller. Please refer to the specific models.
◆ When some indoor units are connected to the wired controller and the remote controller is set in
the auto mode (where the temperature adjusts automatically), the remote controller will override
the wired controllers auto mode setting.
Please read the manual carefully before installing and using this product.
Contents
Wired Remote Controller XE71 (XE71-44/G)........................................................... 1
1 Symbols on LCD ........................................................................................... 1
1.1 Outside View of the Wired Remote Controller ...................................................... 1
1.2 LCD Display of the Wired Remote Controller ........................................................ 1
2 Touch Pad..................................................................................................... 2
2.1 Buttons on the Wired Remote Controller .............................................................. 2
2.2 Function of the Buttons ......................................................................................... 3
AUTO TURBO
F SET
HOUR
Enter/Cancel
Enter/cancel Fan Mode
AUTOT URBO
F SET
HOUR
7 8 9 10 1112 13 14 15 16 17 18 19
Fig.2 LCD Display of the Wired Remote Controller
1
Wired Remote Controller XE71(XE71-44/G)
Table 1
No. Symbols Description
1 Swing function.
2 Sleep function (Only sleep 1).
3 Running modes of the indoor unit (Cooling, Dry, Fan and Heating).
5 Gate-control function.
6 Lock function.
16 Blow function.
17 Timing value.
Quiet function (two types: quiet and auto quiet)
18
(this function is yet unavailable for this unit).
19 SET It will be displayed under the debugging mode.
2 Touch Pad
2.1 Buttons on the Wired Remote Controller
1 2 3 4
Enter/Cancel
Enter/cancel Fan Mode
5 6 7 8
2
Wired Remote Controller XE71(XE71-44/G)
3 By pressing these at the same time when unit is off will be displayed
Fan+▼
+6 on the wired remote controller.
Upon startup of the unit, if there are no problems or if the unit is off,
2 press both at the same time for 5s to enter the lock mode where no
▲+▼
+6 buttons will won’t respond when pressed. Repress both for 5s to cancel
this operation.
While "OFF" the Celsius and Fahrenheit scales can be switched by
4+6 Mode+▼
3
Wired Remote Controller XE71(XE71-44/G)
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit, press again to turn it off.
Note: The state shown in Fig.4 indicates unit is “Off” after powering on. The state shown in Fig.5
indicates the unit is “On” after powering on.
F F
4
Wired Remote Controller XE71(XE71-44/G)
Fig.6
3.4 Fan Setting
In the “On”/”Off” state of the unit, press Fan and the fan speed of the indoor unit will
change in the order shown in Fig.7.
Low Middle High
AUTO F
Fig.7
3.5 Timer Setting
In the “On”/”Off” state of the unit, press Timer to set timer off/on.
Timer "On" setting: Press "Timer", and the LCD will display “xx.x hour”, with “hour” blinking.
Then press ▲or ▼to adjust the time. Then prexx Enter/Cancel to confirm.
Timer "Off" setting: Press "Timer", if LCD won’t display xx.x hour then it means the timer
setting is canceled.
Timer "Off" setting under the “On” state of the unit is shown as Fig.8.
5
Wired Remote Controller XE71(XE71-44/G)
F F F
F F
Fig. 8 Timer off Setting under the “On” State of the Unit
Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by
0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every
0.5s.
6
Wired Remote Controller XE71(XE71-44/G)
Swing Off: When the Swing function is on, press Function to enter the Swing setting interface,
with blinking. After that, press Enter/Cancel to cancel this function.
Swing setting is shown as Fig.9.
F F F
F F
7
Wired Remote Controller XE71(XE71-44/G)
Sleep off: When the Sleep function is activated, press Function to enter the Sleep setting
interface. After that, press Enter/Cancel to can this function.
In the Cooling or Dry mode, the temperature will increase by 1℃ after the unit runs under Sleep
1 for 1hr and 1℃ after another 1hr.After that, the unit will run at this temperature.
In the Heating mode, the temperature will decrease by 1℃ after the unit runs under Sleep 1 for
1hr and 1℃ after another 1hr. After that, the unit will run at this temperature.
Sleep setting is shown as Fig.10.
F
F F
F F
8
Wired Remote Controller XE71(XE71-44/G)
When the Turbo function is activated, press Function to enter the Turbo setting interface and
then press Enter/Cancel to cancel this function.
Turbo function setting is as shown in Fig.11.
F F F
F F
9
Wired Remote Controller XE71(XE71-44/G)
Once the wired remote controller or the remote controller enters the Heating mode, this function
will be turned on automatically.
Press Function in the Heating mode to enter the E-heater setting interface and then press
Enter/Cancel to cancel this function.
Press Function to enter the E-heater setting interface, if the E-heater function is not activated,
and then press Enter/Cancel to turn it on.
The setting of this function is shown as Fig.12 below:
F F F
F F
10
Wired Remote Controller XE71(XE71-44/G)
F F F
F F
11
Wired Remote Controller XE71(XE71-44/G)
Pressing the button “On/Off” also can quit this commissioning status but the set data won’t be
memorized.
Under the commissioning status, if there is no any operation in 20 seconds after the last button
press, it will back to the previous state without memorizing the current data.
Note:
After connected with indoor unit, if the type of ambient temperature sensor has not been manually
set, the wired controller will select the ambient temperature sensor according to the model of connected
IDU; if it connects to cassette type IDU, duct type IDU, floor ceiling type IDU, ceiling type IDU, it will
adopt ③, otherwise it will adopt ①. If the type of ambient temperature sensor is set manually, the wired
controller will subject to the manual setting, and will not set according to automatic IDU model selection.
12
Wired Remote Controller XE71(XE71-44/G)
go to the commissioning status, and then adjust the display in the temperature display area to 01
through the button “Mode” and adjust the setting of the fan speed, which comes to two options.
01: Three low fan speeds; 02: Three high fan speeds
Pressing the button “On/Off” also can quit this commissioning status but the set data won’t be memorized.
Under the commissioning status, if there is no any operation in 20 seconds after the last button
press, it will back to the previous state without memorizing the current data.
1 2 3 4 5
No. 1 2 3 4 5
Socket box Soleplate of the Front Panel of the
Sponge 20×20×2
Name embedded Wired Remote Wired Remote Screw ST2.9X6
Screw M4X25
in the wall Controller Controller
13
Wired Remote Controller XE71(XE71-44/G)
1 2 3 4
6 5
7
Note:CN1 is 485 communication interface and it used
for connecting the 4-core communication wire.
These two needle stands(CN2、CN3) are used for
connecting the smart zone controller. There is no
sequence for these two needle stands. You can
connect one or two needle stand(s) basing on the
requirement.
8 9 10
Fig.15
Fig.15 shows the installation steps of the wired remote controller, but there are some issues that need your attention.
(1). Prior to the installation, please firstly cut off the power supply of the wire buried in the
installation hole, that is, no operation is allowed with electricity during the whole installation.
(2). Pull out the four-core twisted pair line from the installation holes and then let it go through
the rectangular hole behind the soleplate of the wired remote controller.
(3). Stick the soleplate of wired controller on the wall and then use screw M4×25 to fix
soleplate and installation hole on wall together, attach the sponge 20×20×2 at the screw hole
and then press it with fingers to make sure it’s attached firmly.
(4). Insert the four-core twisted pair line into the slot of the wired remote controller and then
buckle the front panel and the soleplate of the wired remote controller together.
(5).
ST2.9X6.
14
Wired Remote Controller XE71(XE71-44/G)
Smart zone
controller
Fig.16
Fig.16 shows the schematic diagram of control system connection. XE71(XE71-44/G) can connect the smart
zone controller (integrated control system). “n” indicates the number of communication node address
(programmable wired controller XE71). The complete system is composed of the smart zone controller,
wired controller XE71 and communication cable. The wired controller XE71can support 16 communication
node addresses at the most (n≤16).
Terminal A and terminal B of the smart zone controller are respectively connected to the corresponding
communication needle stand terminal of the #1wired controller by the communication cable; the other
needle stand of #1 wired controller is connected to the #2 wired controller through the telecommunication
cable and so forth until connect to the #n wired controller. Except the last wired controller in the control
system (only use CN2 or CN3, and the other one will not be connected), there’s no the sequence and the
importance for the wired controller. The series number in the figure is only for the sake of clarity.
Fig.17
Fig.17 shows schematic diagram of DIP switch. There is a 2-bit DIP switch on the main board of wired
controller XE71(XE71-44/G). As for the last #n wired controller in the control system, the 1-bit and the 2-bit of the
DIP switch should be manually pulled to position “on” and position “off” respectively. The DIP switches of
other wired controllers should be kept at the initial ex-factory status (1-bit and 2-bit are set at position
“off”).
CAUTION!
Please pay special attention to the following during the installation to avoid any problems with
the air conditioning unit due to electromagnetic interference.
① . Separate the signal and communication lines of the wired remote controller from the power
15
Wired Remote Controller XE71-44/G
cord and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm,
otherwise the communication of the unit will probably work abnormally.
② . If the air conditioning unit is installed where is vulnerable to electromagnetic interference,
then the signal and communication lines of the wired remote controller must be the shielding
twisted pair lines.
4.3 Dismantlement of the Wired Remote Controller
1 2 3 4
5 Errors Display
If there is an error occurring during the operation of the system, the error code will be displayed
on the LCD, as show in Fig.18. If multi errors occur at the same time, their codes will be displayed
circularly.
Note: In event of any error, please turn off the unit and contact the professionally skilled
personnel.
Enter/cancel