Rowan Adjustable Canister Anchor Bolt

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Rowan Adjustable Canister Anchor Bolt

ROWAN Rev 2-22-08

The Rowan Adjustable Canister Bolt is an engineered, OPTIONAL TM


2 H HEX NUT
field friendly anchor bolt. It can be adjusted laterally and ROTABOLT DOUBLE
LOAD MONITOR
angularly to compensate for installation errors or thermal AVAILABLE
SPHERICAL WASHER

A
growth of equipment, drops below grade for easy
FOAM DONUT SEAL
equipment installation, has adjustable projection, and is AT TOP OF CANISTER
SLEEVE
lightweight so it is easy to install. Since the entire bolt
length is free to stretch, the loss of torque from seating or
relaxation is greatly reduced, providing a more
maintenance free anchor bolt. PLASTIC PIPE SLEEVE

Prevents Bolt Binding From:

♦ Missed location at installation TM


(+ ⅛” to ¼” adjustability) R-100 SERIES BOLT/ANCHOR ROD
8 TPI ROLLED THREADS
PER ASTM A-193 AND
GRADE B7 STEEL
♦ Thermal growth of equipment

B
(angular adjustability) LATERAL
A. RANGE OF ADJUSTMENT ADJUSTMENT
ABOVE TOP OF CONCRETE FEATURE

B. UPPER PLASTIC TUBING

C. LOWER PLASTIC TUBING


AND STEEL HOUSING E
Benefits:
D. STEEL HOUSING

♦ ⅛” to ¼” lateral adjustability

D
E. STEEL HOUSING DIAMETER
♦ Adjustable projection E HOUSING
(see chart) DIAMETER
C

♦ Drops below grade for easy


equipment installation
♦ 1° to 2° angular adjustability
♦ Light weight canister for
easy installment STANDARD DIMENSIONS FOR ROWAN R-100/CANISTER ANCHOR BOLT
PART NUMBER SIZE A B* C D E CAPACITY*
♦ Total bolt length free to NA 807528XCT10 ¾” 0-5” 18” 10” V 3” 27,000
stretch NA8100028XCT08 1” 0 – 6” 18” 10” A 5” 50,000
NA8113034XCT08 1 ⅛” 0 – 6” 24” 10” R 5” 67,000
NA8125041XCT08 1 ¼” 0 – 7” 30” 11” I 5” 84,000
NA8138051XCT08 1 ⅜” 0 – 8” 39” 12” E 5” 104,000
NA8150061XCT08 1 ½” 0 – 9” 48” 13” S 5” 125,000
NA8175071XCT08 1 ¾” 0 – 12” 54” 17” - 5” 174,000
NA8200081XCT08 2” 0 – 16” 60” 21” - 6” 232,000
NA8225096XCT08 2 ¼” 0-16” 75” 21” - 6” 299,000
*BASED ON GRADE B-7 PUBLISHED DATA AND USING 80% OF 105,000 PSI YIELD STRENGTH
(125,000 PSI TENSILE STRENGTH) IN POUNDS. ACTUAL PULLOUT STRENGTH MAY VARY
DEPENDING ON THE QUALITY OF CONCRETE AND THE STEEL REINFORCING.

* Custom lengths longer or shorter available

Robt. L. Rowan & Assoc., Inc. · 3816 Dacoma · P.O. Box 920760 · Houston, Texas 77292-0760
Tel (713) 681-5811 · Toll Free (800) 231-2908 · Fax (713) 681-5815
Visit our website at www.rlrowan.com
© Copyright 1999 – Robt. L. Rowan & Assoc., Inc.

Page 1 of 1