Cable Protection Systems Latvia
Cable Protection Systems Latvia
www.radiustelecoms.com
The content of this publication is for information only. Information in this publication is given in good faith
and Radius Systems accepts no liability for its content. Information is correct at the time of going to press.
About us
Radius Systems has
manufactured and supplied
polyethylene (PE) pipe and
fittings to major utilities around
the world since 1969 and
telecoms companies since 1988
With four manufacturing facilities in the UK, a joint venture
in Abu Dhabi, a global distribution network and over 500
employees, we are proud to supply over 100 countries.
BS OHSAS 18001:2007
ISO 9001:2008
ISO 14001
We pledge to:
3
About FTTx
FTTx FTTC
Fibre-to-the-x Fibre-to-the-cabinet or fibre-to-the-curb
A generic term for any broadband network architecture that Very similar to FTTN (see below), but the street cabinet is
uses optical fibre to replace all or part of the usual metal local closer to the user’s premises; typically within 300m.
loop used for the last mile.
Mole Ploughing
• Specialist machines dig
the trench and lay the
duct in one operation
• Special heavy duty
tube assemblies
5
FTTx applications
Our telecoms and FTTx systems can be used anywhere in the network from backbone to
deep fibre applications. This can include metro loops, WAN, LAN, access networks and last
mile connections right to the premises.
Our FTTx product range provides a wide range of solutions for The main influences for the infrastructure deployment
next generation access networks. methodology are:
• type of FTTx area
Access networks may connect some of the following:
• size of the FTTx network
• Fixed wireless network antenna, for example
• initial deployment cost of the infrastructure elements
wireless LAN or WiMAX
(CAPEX)
• Mobile network base stations
• ongoing costs for network operation and maintenance
• Subscribers in residential houses, terraces or
(OPEX)
blocks of flats
• network architecture, for example PON (passive optical
• Larger buildings such as schools, hospitals and businesses
network) or Active Ethernet
• Key security and monitoring structures like surveillance
• local conditions, for example, local labour costs, local
cameras, security alarms and control devices
authority restrictions (traffic control) and others
Network applications The fibre deployment technology will determine CAPEX and
OPEX, as well as the reliability of the network. These costs
The network environment can be broadly split into:
can be optimised by choosing the most appropriate active
• intercity/regional solution combined with the most appropriate infrastructure
• city deployment methodology. These methods include:
• campus, business parks, private networks
• conventional underground duct and cable
• open residential
• blown microtubes and cable
• rural
• direct buried cable
• building type and density – single homes or
• aerial cable
multi-dwelling units (MDUs)
• ‘other rights of way’ solutions
The type of site will be a key factor in deciding the most
appropriate network design and architecture. Types include:
• Greenfield – new build where the network will be
introduced at the same time as the buildings
• Brownfield – where there are existing buildings and
infrastructure but the infrastructure is to a lower standard
• Overbuild – adding to the existing infrastructure
Helping you achieve tomorrow’s networks – future proof, flexible and cost effective
City/Metro
Residential MDUs
Backbone
Residential Homes
Business MDUs
Industrial
Campus/Business Parks
7
FTTx Microtubing Systems
9
MiniGlide™ Tubing
Standard Wall Drum Lengths (m) Thick Wall Drum Lengths (m)
OD ID OD ID
500 1000 2000 2500 4000 5000 500 1000 2000 2500 4000 5000
(mm) (mm) (mm) (mm)
7 5.5 • • • • • 7 3.5 • • • • •
10 8 • • • • 8 3.5 • • • •
12 10 • • • 10 6 • • • •
14 11 • • 14 10 • •
14 12 • • 16 12 • •
16 10 • •
13
MicroGlide™ Tubing
Configuration Tube OD/ID Assembly Drum Length (m) Configuration Tube OD/ID Assembly Drum Length (m)
# of Tubes (mm) OD (mm)* 500 1000 2000 4000 # of Tubes (mm) OD (mm)* 500 1000 2000 4000
1 5/3.5 6.9 • • • • 1 5/3.5 6.9 • • • •
2 5/3.5 12.0 x 7.0 • • • • 2 5/3.5 12.0 x 7.0 • • • •
4 5/3.5 14.1 x 12.0 • • • • 4 5/3.5 14.1 x 12.0 • • • •
7 5/3.5 17.0 x 15.7 • • • • 7 5/3.5 17.0 x 15.7 • • • •
12 5/3.5 22.4 x 20.1 • • • • 12 5/3.5 22.4 x 20.1 • • • •
19 5/3.5 27.0 x 24.3 • • • 19 5/3.5 27.0 x 24.3 • • •
24 5/3.5 32.0 x 31.8 • • • 24 5/3.5 32.0 x 31.8 • • •
Configuration Tube OD/ID Assembly Drum Length (m) Configuration Tube OD/ID Assembly Drum Length (m)
# of Tubes (mm) OD (mm)* 500 1000 2000 4000 # of Tubes (mm) OD (mm)* 500 1000 2000 4000
1 5/3.5 7.5 • • • • 1 5/3.5 6.9 • • • •
2 5/3.5 12.5 x 7.5 • • • • 2 5/3.5 11.9 x 6.9 • • • •
4 5/3.5 15.5 • • • • 4 5/3.5 14.0 x 11.9 • • • •
7 5/3.5 18.5 • • • • 7 5/3.5 16.9 x 15.6 • • • •
12 5/3.5 22.2 x 19.9 • • • •
* Nominal values
19 5/3.5 26.9 x 24.2 • • •
24 5/3.5 31.9 x 31.6 • • •
17
Special Assemblies
19
Special Assemblies
Anti-Termite (Direct Bury)
• For use where termites are problematic
• Nylon layer provides protection against attack by termites
Chemical Resistant
• For use in environments at risk of chemical contact
• Maximum chemical resistance is provided through four
layers of protection; an initial aluminium layer, an inner PE
sheath, a chemical resistant layer and an outer PE sheath
Sheath Stripper
• Circular and longitudinal cutting
• Adjustable depth, replaceable hardened blade
Longitudinal Cutter 1A
• 4 way cam for different thicknesses
• Shoe for small cables, reversible blade
Tube Cutter
For Tube OD Pack Qty Product Code
4-14mm 1 ZA2951
Spare Blade 10 ZA2952
21
Matrix™ Joint Closures
23
FTTx Connectors and Sealing
Reducer
• For joining microtubes of different outer diameters
Microduct A Microduct B
Pack
Tube OD Tube ID Tube OD Tube ID Product Code
Qty
(mm) (mm) (mm) (mm)
5 3.5 3 2.1 100 UV0153
5 3.5 4 2.5 100 UV0154
7 5.5 3 2.1 100 UV0156
7 5.5 5 3.5 100 UV0158
10 8 5 3.5 100 UV0160
10 8 7 5.5 100 UV0161
12 10 5 3.5 100 UV0163
12 10 7 5.5 100 UV0164
12 10 10 8 100 UV0166
14 10 10 8 100 UV0167
14 10 12 10 100 UV0168
16 12 12 10 100 UV0169
25
FTTx Push-Fit Connectors
End Stop
• For sealing the end of an open microtube
Tube OD Cable OD
Pack Qty Product Code
(mm) Ramge (mm)
4 Fibre Unit 100 UV0184
5 Fibre Unit 100 UV0185
5/4 Fibre Unit 100 UV0186
7 1/3.8 Cable 100 UV0188
7 2/5.5 Cable 100 UV0187
10 1-4 Cable 100 UV0191
10 3-6 Cable 100 UV0202
10 5-8 Cable 100 UV0190
12 3-6 Cable 100 UV0193
12 5-8 Cable 100 UV0194
12 7-10 Cable 100 UV0192
14 3-6 Cable 100 UV0197
14 5-8 Cable 100 UV0196
14 7-10 Cable 100 UV0200
14 9-12 Cable 100 UV0195
16 9-12 Cable 100 UV0198
Tube OD Cable OD
Pack Qty Product Code
(mm) Range (mm)
7 1-3.8 100 UV0370
7 2-5.5 100 UV0267
10 1-4 100 UV0371
10 3-6 100 UV0202
10 5-8 100 UV0268
12 3-6 100 UV0373
12 5-8 100 UV0374
12 7-10 100 UV0269
14 3-6 100 UV0375
14 7-10 100 UV0376
14 5-8 100 UV0270
14 9-12 100 UV0377
16 9-12 100 UV0271
27
FTTx Sealing Systems
Duct Sealing Plugs
• Simple and effective splashproof and dirt tight sealing of ducts
• Can be used as a blank plug or for sealing around a cable/tube
• Special conical shape can be easily cut to fit cable/tube diameter
Duct ID Cable/
Duct OD No. of Product
Range tube OD Pack Qty
(mm) Ports Code
(mm) (mm)
32 27.0-28.5 6.0-16.0 1 40 UV0500
40 31.5-33.0 5.0-22.0 1 40 UV0501
50 39.5-41.5 8.0-20.0 1 10 UV0502
Duct ID No. of
Duct OD Minitube Product
Range Minitube Pack Qty
(mm) OD (mm) Code
(mm) Ports
40 33 7 7 100 UV0514
40 33 10 5 100 UV0515
40 33 12 4 100 UV0516
* Other sizes available on request, subject to minimum order quantities and lead time
No. of
Duct OD Minitube Product
Minitube Pack Qty
(mm) OD (mm) Code
Ports
40 7 10 40 UV0258
40 10 5 40 UV0529
40 12 4 10 UV0530
50 7 14 25 UV0531
50 10 7 25 UV0532
* Other sizes available on request, subject to minimum order quantities and lead time
No. of
Duct OD Minitube Product
Minitube Pack Qty
(mm) OD (mm) Code
Ports
32 10 3 10 UV0544
12 1
32 10 1 10 UV0545
7.5 1
40 7 10 10 UV0546
40 10 5 10 UV0547
40 12 4 10 UV0548
16 1
50 10 UV0549
12 3
50 10 7 10 UV0550
50 12 7 10 UV0551
* Other sizes available on request, subject to minimum order quantities and lead time
Duct ID No. of
Duct OD Minitube Product
Range Minitube Pack Qty
(mm) OD (mm) Code
(mm) Ports
32 26.6-27.7 7 3 12 ZA0448
32 26.6-27.7 10 3 12 ZA0449
40 32.2-33.8 12 3 12 ZA0450
40 32.2-33.8 7 7 12 ZA0451
40 32.2-33.8 10 5 12 ZA0452
50 40-41.2 12 5 12 ZA0453
50 40-41.2 10 5 12 ZA0454
50 40-41.2 7 10 12 ZA0455
50 40-41.2 10 7 12 ZA0456
29
Have you got the complete set?
FTTx Microtubing Systems
Cable Protection Systems
www.radiustelecoms.com
The content of this publication is for information only. Information in this publication is given in good faith
and Radius Systems accepts no liability for its content. Information is correct at the time of going to press.