TSG

Basic CT training : Reconstruction CT

Basics of Image Reconstruction

36 sheets
(recon.ppt *B)

© Copyright Toshiba 1998 1


TSG

Basic CT training : Reconstruction CT

TUBE

DETECTOR

DAS
CALIBRATION
DATA
Pre-Proc
RAW DATA

Reconstructor

IMAGE DATA

© Copyright Toshiba 1998 2


TSG

Basic CT training : Reconstruction CT

TUBE

DETECTOR

DAS
CALIBRATION
DATA
Pre-Proc
RAW DATA

Reconstructor

IMAGE DATA

© Copyright Toshiba 1998 3


TSG

Basic CT training : Reconstruction CT

Pre-Processing (1/5)
TUBE
ª Input = Pure Raw Data
DETECTOR
CALIBRATION

DAS Pre Processing functions :


DATA

• Offset correction
Pre-Proc
RAW DATA • Reference correction
• Water Calibration
Reconstructor
• Air Calibration
IMAGE DATA

ª Output = Raw Data

© Copyright Toshiba 1998 4


TSG

Basic CT training : Reconstruction CT

Pre-Processing (2/5)
TUBE

DETECTOR Offset correction


CALIBRATION

DAS ¤ Offset data is detector


DATA

data taken without X-ray.


Pre-Proc
RAW DATA
¤ Scan data is corrected
Reconstructor with offset data to
compensate for drifts in
IMAGE DATA
the DAS.

© Copyright Toshiba 1998 5


TSG

Basic CT training : Reconstruction CT

Pre-Processing (3/5)
TUBE

DETECTOR Reference correction


CALIBRATION

DAS ¤ Uses the output of the


DATA

reference detector.
Pre-Proc
RAW DATA (= very close to tube)

Reconstructor ¤ Compensates for


IMAGE DATA
variations in tube output.

© Copyright Toshiba 1998 6


TSG

Basic CT training : Reconstruction CT

Pre-Processing (4/5)
TUBE Water Calibration
DETECTOR » Calibration data from disk
CALIBRATION

DAS is loaded into Pre-Proc.


DATA

Pre-Proc
RAW DATA
(Calibration data was
taken with water phantom)
Reconstructor

IMAGE DATA
» Is used to set water value
to 0 H (0 Hounsfield).

© Copyright Toshiba 1998 7


TSG

Basic CT training : Reconstruction CT

Pre-Processing (5/5)
TUBE
Air Calibration
DETECTOR
CALIBRATION

» Calibration data from disk


DAS is loaded into Pre-Proc.
DATA

Pre-Proc
RAW DATA (Calibration data was
taken during air scan.)
Reconstructor

IMAGE DATA » Compensates for


differences in channel
characteristics.
© Copyright Toshiba 1998 8
TSG

Basic CT training : Reconstruction CT

Reconstruction Flow (S&V)


From DAS Pre
(Pure Raw Data) Processing

To HDD
Reconstructor (Raw Data)

Filtering

Back To Monitor and HDD.


Projection (Image Data)

© Copyright Toshiba 1998 9


TSG

Basic CT training : Reconstruction CT

Simple backprojection (1/7)


1 reading of all detector cells (1 view)

1 Qn 896
channels

ell
Example orc
ect
1 scan is 900 readings (views) t
de
1
of
e
alu
v 10
© Copyright Toshiba 1998
TSG

Basic CT training : Reconstruction CT

Simple backprojection (2/7)

are taken for every detector cell.


During a scan 900 samples (views)
view 1 I

1
channels
Qn 896

view n I

1
channels
Qn 896

view 900
I

1
channels
Qn 896

© Copyright Toshiba 1998 11


TSG

Basic CT training : Reconstruction CT

Simple backprojection (3/7)


X-ray
tube
Reconstruction Matrix

Detector
Array

Detector cell
value of
detector
readout
Value of detector readout
Qn
is ‘smeared’ back on the
reconstruction matrix.
© Copyright Toshiba 1998 12
TSG

Basic CT training : Reconstruction CT

Simple backprojection (4/7)


Value of matrix cell + (0.5* Qn)

Qn
Value of matrix cell + (1* Qn)

© Copyright Toshiba 1998 13


TSG

Basic CT training : Reconstruction CT

Simple backprojection (5/7)


This is done for all channels and all views.

Qn ’
Qn’’

© Copyright Toshiba 1998 14


TSG

Basic CT training : Reconstruction CT

Simple backprojection (6/7)

4 6
3
7 1
2
5 4 5
3

3 3 7 9 8 14 13 16
7 7 11 13 16 17 19 22

1 2 3 4

© Copyright Toshiba 1998 15


TSG

Basic CT training : Reconstruction CT

Simple backprojection (7/7)

After all detector readings


from all angles are ‘smeared’ back.

© Copyright Toshiba 1998 16


TSG

Basic CT training : Reconstruction CT

Backprojection for parallel beam


P1

QA P1 QB

The attenuation value for P1 is


QA P2 found by linear interpolation.

QB
a
b

α QN

VIEWα

© Copyright Toshiba 1998 17


TSG

Basic CT training : Reconstruction CT

Backprojection for fan beam


P1

QA P1 QB

P2 The attenuation value for P1 is


QA found by linear interpolation.

a QB
b

QN
α
VIEWα

© Copyright Toshiba 1998 18


TSG

Basic CT training : Reconstruction CT

Linear superposition method

T
T

T
T

© Copyright Toshiba 1998 19


TSG

Basic CT training : Reconstruction CT

Result of Lineair superposition method

Original object Result of Lineair Unsharp


Unsharpresult
result
Superposition method

IMPROVEMENT:
IMPROVEMENT:
Filtered
Filtered
Backprojection
Backprojection

© Copyright Toshiba 1998 20


TSG

Basic CT training : Reconstruction CT

Filtered backprojection (FFT)


Filtering System

Filter function
multiplication Fast Inverse
Fast Fourier Fourier
Transformation Transformation

FFT FFT-1
Input Filter Function Output

Real space Transformation Transformation Real space


Frequency space data
data area area data

© Copyright Toshiba 1998 21


TSG

Basic CT training : Reconstruction CT

Filtered backprojection(FFT)
Amplitude Amplitude of Fourier coefficients

A1 A1
Frequency = f1
t
f1 spatial frequency
Fourier
transform

A2 Frequency = f2 A2

t
f2 spatial frequency

This profile is the sum of A1


both sine waves f1 and f2 A2

t
f1 f2 spatial frequency

© Copyright Toshiba 1998 22


TSG

Basic CT training : Reconstruction CT

Filtered backprojection(FFT)
Measured
Absorption
value
Real measured profile
in spatial domain
(detector output)

r
(distance in space)
Amplitude
Fourier
coefficients

Real measured profile


in Fourier domain

R
(spatial frequency)

© Copyright Toshiba 1998 23


TSG

Basic CT training : Reconstruction CT

Filtered backprojection
Measurement Filter data Result after
data filtering

part dge
e e
ativ arp
g
e ne a sh
Th l give
wil

© Copyright Toshiba 1998 24


TSG

Basic CT training : Reconstruction CT

Filtered backprojection

T
T

T
T

© Copyright Toshiba 1998 25


TSG

Basic CT training : Reconstruction CT

Linear superposition vs. Filtered backprojection

Original object Result of Linear Result of Filtered


Superposition method backprojection

© Copyright Toshiba 1998 26


TSG

Basic CT training : Reconstruction CT

Reconstruction Flow (S&V)


From DAS Pre
(Pure Raw Data) Processing

To HDD
(Raw Data)

After
Afterbackprojection
backprojection
the
theimage
imageis
isin
inthe
the
Reconstructor

Filtering
backprojector
backprojectormemory.
memory.

Back To Monitor and HDD.


Projection (Image Data)

© Copyright Toshiba 1998 27


TSG

Basic CT training : Reconstruction CT

Reconstructor systems
• FRU
(Fast Reconstruction Unit) Ö8 seconds
• AFRU
(Advanced F.R.U.) Ö7 seconds
• RTRU (Master)
(Real Time R.U.) Ö5 seconds
• RTRU (Master + slave) Ö2 seconds

© Copyright Toshiba 1998 28


TSG

Basic CT training : Reconstruction CT

Viewing
• The values in the backprojector memory are
Hounsfield units (after Sir G.N. Hounsfield).

• The definition of the Hounsfield unit is :


µx - µH2O
CT number = 1000 x −−−−−−−−−
µH2O

or: CT number = 5263 x µx - 1000

© Copyright Toshiba 1998 29


TSG

Basic CT training : Reconstruction CT

Viewing
• Some Hounsfield values are :
Bone : 200 - 1000
Dense tumour tissue : 50 - 90
Congealed blood : 55 - 75
Grey matter (brain) : 36 - 46
White matter (brain) : 22 - 32
Blood : 12
Water : 0
Fat : -100
Air : -1000

© Copyright Toshiba 1998 30


TSG

Basic CT training : Reconstruction CT

Viewing
• To view the image on the monitor the H-
values are displayed as gray-values.

• If the whole Hounsfield scale (-1000 to


+3100) is displayed in gray-values no details
are visible.

• To be able to see details, Window Width and


Window Level techniques are applied.

© Copyright Toshiba 1998 31


TSG

Basic CT training : Reconstruction CT

Viewing
• Window Width (WW) selects the number of
H-values we see as 256 gray-steps.

» To see details : select narrow WW.

• Window Level (WL) selects the center value


of the WW.

» To see certain tissue : select correct WL.

© Copyright Toshiba 1998 32


TSG

Basic CT training : Reconstruction CT

Viewing : Window Width


+1000

(+600)
+500 (+500)
Window Width Ex.: 600H values
Window Width are displayed in
(=400H) (=600H) 256 gray-steps
(+100)
0 (0)

-500

-1000
© Copyright Toshiba 1998 33
TSG

Basic CT training : Reconstruction CT

Viewing : Window Level


+1000

(+600)
+500
Window Level
(= +300H)

0 (0)

(-100)

Window Level
-500 (= -500H)

(-800)

-1000
© Copyright Toshiba 1998 34
TSG

Basic CT training : Reconstruction CT

Viewing : WW visual

WW = 100 WW = 1000
WL = 30 WL = 30

© Copyright Toshiba 1998 35


TSG

Basic CT training : Reconstruction CT

Viewing : WL visual

WW = 100 WW = 100
WL = 30 WL = 0

© Copyright Toshiba 1998 36