Ultrasonic Liposuction Unit Manual
Ultrasonic Liposuction Unit Manual
Ultrasonic Liposuction Unit Manual
Model S-48E
User Manual
Overview
Cellulite and associated obesity issues have become one of the major problems in developed countries.
In China, it is estimated that at least ½ billion people are seeking some form of body slimming modality.
Approximately 30% of the people in Beijing, Shanghai and Guangzhou died last year from diseases related to
obesity, overshadowing deaths from natural causes.
Unfortunately, many slimming products that have tried to fill this demanding market are unscientific and use
techniques that simply don’t work or reduce fat in the short term with no sustainable results. Some devices
function in ways that actually do damage to the body.
There are two general categories of obesity – primary and secondary. The causes of primary obesity relate to
eating habits, psychological issues, education and the availability of low fat and low sugar foods. Primary
obesity accounts for 99% of all obese people. Secondary obesity is more complicated, although it accounts for
only 1% of the population, the causes have been speculated to be genetic, glandular or viral. Genetic obesity is
where the person has a genetic disorder or genetic predisposition to accumulate fatty tissue in areas of the body.
Glandular obesity is where severe weight gain is from a disorder related to malfunctions of the pituitary gland,
thyroid gland, gonadotrophic disorder, as well as Cushing’s syndrome all of which are serious medical
conditions. Viral obesity is not yet accepted by some parts of the medical community but basically (as
discovered by Indian Medial Research) is where a type of bird flu virus cross contaminates to humans. The
virus, once in the cells will cause immature fat cells to become mature and therefore absorb fat. People who
show the particular antigen for the virus experience abnormal weight gain despite their diet. Discovered in the
‘70’s it is estimated that this accounts for about 10% of obese people in the United States, 3% in the United
Kingdom and as much as 40% in India – other countries have not been studied.
In conclusion, with most cases of primary obesity and just about all cases of secondary obesity, it is virtually
impossible for the person to lose a sustainable amount of weight due to factors such as life style, family history,
inability to exercise, or medical reasons.
This equipment represents a major step in returning these people to a state where good health and vitality can be
maintained.
Unit Dynamics
Control Panel
Unit’s Attachments
Strong Ultrasound Head (40KHz)
Marked as “CRACK”
Operational Steps
• Plug in the power and switch the unit on via the mains switch located at the rear of the unit. The LCD
display will illuminate with the base menu.
• After selecting the appropriate language setting, press “ENTER” to move to the next step.
• After entering the main menu, use the UP or DOWN buttons to choose the required function –
Ultrasonic Liposuction, RF Dissolving Fat or Oriented Liposuction. In a normal treatment Ultrasonic
Liposuction is performed first.
• Ultrasonic Liposuction –
On entering this menu, use the UP or DOWN buttons to select “Ultrasonic Liposuction” then press
ENTER to enter this menu. Use the UP or DOWN buttons to select the aspects of this menu.
Select the “Time” and then using the LEFT or RIGHT buttons, determine the length of time required
then move DOWN to select “Wave Shape” Two wave shapes are available, Continuous (indicated by
a sine wave) or Intermittent (indicated by a square wave). Continuous runs the ultrasound head
continuously and is able to penetrate the deeper layers where the fatty tissue is located above muscle.
Intermittent turns the head on and off about twice per second and has a more profound effect on sub-
dermal fat that lies just below the skin.
Then move DOWN to select “Intensity” and then, by using the LEFT and RIGHT buttons adjust the
required power setting you wish to use. When finished note the bottom of the display will read
“Preparing”.
To begin treatment, press ENTER. While the head is in operation the bottom of the display will
change to “Working” at which point the timer will begin to count down. It is advised that the
ultrasound head is not held without direct contact with the skin for any length of time as there is a
possibility that damage to the head could occur.
• Apply a reasonable amount of conductive jell - usually an aqua-jell or ultrasound jell, this could be
mixed with a skin or beauty preparation if required.
• To finish the treatment, the timer will reach zero and an audible signal will indicate that the head is no
longer in operation. If a pause is required at any time, simply press the ENTER button and the display
will switch from “Working” to “Preparing” indicating that the head is not in operation.
• Upon completion of this step, press SHIFT to return to the main menu to begin the next selection –
Move the arrow to RF Dissolving Fat and press ENTER to enter this menu.
• RF Dissolving Fat –
• Select the “Time” and then using the LEFT or RIGHT buttons, determine the length of time required
then move DOWN to select “Intensity” and then, by using the LEFT and RIGHT buttons, adjust the
required power setting you wish to use.
• When finished note the bottom of the display will read “Preparing”. To begin treatment, press
ENTER. While the head is in operation the bottom of the display will change to “Working” at which
point the timer will begin to count down. It is advised that the ultrasound head is not held without
direct contact with the skin for any length of time as there is a possibility that damage to the head
could occur.
• Apply a reasonable amount of conductive jell - usually an aqua-jell or ultrasound jell, this could be
mixed with a skin or beauty preparation if required. Please note that with this head the frequency is
exceptionally high and as a result the head may get reasonably hot, this is normal, however, if there is
insufficient conductive jell between the head and the skin the patient may feel a burning
sensation or other discomfort.
• To finish the treatment, the timer will reach zero and an audible signal will indicate that the head is no
longer in operation. If a pause is required at any time, simply press the ENTER button and the display
will switch from “Working” to “Preparing” indicating that the head is not in operation.
• Upon completion of this step, press SHIFT to return to the main menu to begin the next selection –
Oriented Liposuction.
• Oriented Liposuction –
Use the UP or DOWN buttons to select the aspects of this menu. Select the “Time” and then using the
LEFT or RIGHT buttons, determine the length of time required then move DOWN to select “Mode”
and then, by using the LEFT and RIGHT buttons select either A,B or C which sets the control mode
used for the electrical stimulation part of this treatment.
a. Select “A” if it is required to stimulate the lymph nodes and lymphatic vessels surrounding the
intestines and abdominal region. This emits a single pulse at about 1Hz (pulse per second) which
contracts the involuntary muscles and helps to accelerate the movement of fluid though the
lymph system.
b. Select “B” if you require stimulation of soft fatty tissue that has a flabby consistency. This
produces a faster pulse of around 2Hz. This has been shown to have the greatest effect this type
of tissue.
c. Select “C” if you need to stimulate fatty tissue that has a more solid consistency usually over
muscle areas such as cellulite deposits over the hips and thighs. The unit will produce a variable
pulse scaling from 10Hz to 20Hz and then back again. The idea is to stimulate the tissue
contractions as well as the underlying muscle to hasten the movement of fluid through the lymph
system.
Then move down to “Intensity” and then, by using the LEFT and RIGHT buttons, adjust the required
power setting you wish to use for the electrical stimulation this setting can be changed while the unit
is in operation so it is often preferable to adjust this setting using feedback from the patient. Then
move down to “Light Intensity” and then, by using the LEFT and RIGHT buttons, adjust the
required power setting you wish to use for the photon stimulation, this setting can also be changed
while the unit is in operation but generally it is used at full power since the patient will feel no
discomfort or side effects from this aspect of the treatment. When finished note the bottom of the
display will read “Preparing”. To begin treatment, press ENTER. While the unit is in operation the
bottom of the display will change to “Working” at which point the timer will begin to count down.
• Upon completion of this step, press SHIFT to return to the main menu and the unit can now be
switched off via the mains switch located at the rear of the unit.
Second: Configure the unit to desired settings using the “RF Dissolving Fat” section of the menu. Apply a
reasonable amount of ultrasonic jell or other suitable preparation to the area of treatment. Using the
“MELT” ultrasonic head, apply the head to the skin and depress the ENTER button to begin operation.
(Commonly, but not necessarily, both heads are used for the same period of time).
Third: Configure the unit to desired settings using the “Oriented Liposuction” section of the menu. Apply
a small amount of ultrasonic jell or other electrically conductive preparation to three chrome electrodes on
each head being used. Not all of the six heads have to be used. The heads are normally used with the light
power setting at full, the electrical stimulation setting should be increased to maximum patient comfort.
Press the ENTER button to begin operation. As a rule of thumb, timing of this step is nominally half to
three quarters of the treatment time used for the ‘Melt’ head.
Please note: Ultrasound heads of any description do not function well if held in mid-air. There is a
possibility that the energy can feed back and damage the head. Keep the ultrasound head in good contact
with the skin as much as possible while in the ‘working’ mode.
On abdominal areas, move slowly in small circles with a smooth consistent movement. I would emphasize
slowly in most cases since it takes a reasonable amount of energy to break cell membranes and/or
emulsify fat, therefore, by moving the head too fast will result in less energy being absorbed by individual
cells and a corresponding reduction in the amount of tissue being affected.
When using the Oriented Liposuction place the heads evenly over both sides of the body. Use conductive
jell to get a good electrical connection with the skin and use the supplies stretch bands to hold them in
place. Since the posterior buttocks and lower back lies generally over muscle it is advisable to select the
“C” setting. It is suggested that 20 minutes of light and electrical stimulation over the whole surface of the
buttocks area would be appropriate. Normally the light therapy is set to high and the electrical stimulation
set to a high level in relation to patient comfort.
When using the Oriented Liposuction place the heads evenly over both sides of the body. Use some
conductive jell to get a good electrical connection with the skin and use the supplies stretch bands to hold
them in place. Since these areas are obviously over muscle it is advisable to select the “C” setting. It is
suggested that 20 minutes of light and electrical stimulation over the whole surface of the buttocks area
would be appropriate. Normally the light therapy is set to high and the electrical stimulation set to a high
level in relation to patient comfort.
Treat each side for approximately 10 to 15 minutes with the ‘Crack’ as well as the ‘Melt’ heads. With the
‘Melt’ head, pay close attention to the heat generated during the treatment. It is not advisable to heat the
tissue to over 40 degrees Celsius, otherwise damage to the collagen matrix in the sub-dermal layer could
occur. The amount of heat generated is directly proportional to the power setting used. Generally, if the
tissue becomes overly red and very warm, then it’s time to move on to another area. Although the
ultrasound waves on both heads are focused to provide a maximum of intensity at a depth to about 30mm
one should always pay attention to underlying organs and tissue. In this case there are ribs, plural cavity
(filled with fluid), plural membrane and lung tissue. These tissues are quite resilient and will absorb a
great deal of energy, however, the “go slow” approach is always wise.