750W Single Output Power Supply ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E
750W Single Output Power Supply ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E ¡E
E¡¡E¡½ Features :
Universal AC input / Full range
¡E¡E Protections: Short circuit / Overload / Over voltage / Over temperature / Fan alarm
Output voltage can be trimmed between 40 ~ 110% of the rated output voltage
¡E¡E Output OLP can be trimmed between 40 ~ 110% of the rated output current
Forced air cooling by built-in DC fan
¡E¡E DC OK Signal
Built-in remote ON-OFF control
SPECIFICATION
MODEL RSP-750-5 RSP-750-12 RSP-750-15 RSP-750-24 RSP-750-27 RSP-750-48
DC VOLTAGE 5V 12V 15V 24V 27V 48V
RATED CURRENT 100A 62.5A 50A 31.3A 27.8A 15.7A
CURRENT RANGE 0 ~ 100A 0 ~ 62.5A 0 ~ 50A 0 ~ 31.3A 0 ~ 27.8A 0 ~ 15.7A
RATED POWER 500W 750W 750W 751.2W 750.6W 753.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
OUTPUT VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 10 ~ 13.5V 13.5 ~ 16.5V 20 ~ 26.4V 24 ~ 30V 43 ~ 55V
VOLTAGE TOLERANCE Note.3 ¡Ó2.0% ¡Ó1.0% ¡Ó1.0% ¡Ó1.0% ¡Ó1.0% ¡Ó1.0%
LINE REGULATION ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5%
LOAD REGULATION ¡Ó2.0% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5% ¡Ó0.5%
SETUP, RISE TIME 1000ms, 50ms at full load
HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) 0.97/230VAC 0.98/115VAC at full load
INPUT EFFICIENCY (Typ.) 82% 87% 89% 91% 91% 92%
AC CURRENT (Typ.) 5V : 5.6A/115VAC 2.8A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC
INRUSH CURRENT (Typ.) 25A/115VAC 40A/230VAC
LEAKAGE CURRENT <2.0mA / 240VAC
105 ~ 125% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 56.6 ~ 66.2V
PROTECTION OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
85 ¢J¡Ó ¢J
5 (TSW2 ) detect on heatsink of O/P diode; 80 ¢J¡Ó ¢J
5 (TSW1 ) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
AUXILIARY POWER(AUX) ¡Ó
12V @ 0.1A ( 10%)
REMOTE ON/OFF CONTROL Note.6 Power on : short between on/off(pin13) & 12V-AUX(pin14) on CN50 Power off : open between on/off(pin13) & 12-AUX(pin14) on CN50
FUNCTION DC OK SIGNAL The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V
OUTPUT VOLTAGE TRIM Note.6 Adjustment of output voltage is possible between 40 ~ 110% of rated output
OUTPUT OLP TRIM Adjustment of output OLP is possible between 40 ~ 110% of rated output
WORKING TEMP. -30 ~ +70 ¢J (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY ¢J
-40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT ¡Ó0.03%/¢J (0 ~ 50¢J)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH ¢J
(Note 4) EMC EMISSION Compliance to EN55022 (CISPR22), EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
MTBF 120.8Khrs min. MIL-HDBK-217F (25 ) ¢J
OTHERS DIMENSION 250*127*41mm (L*W*H)
PACKING 1.64Kg; 6pcs/10.8Kg/1.1CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. ¢J
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains three shorting wires: one is from on/off(pin13) to
12V-AUX(pin14), two is from PC(pin7) to PO(pin8) and the other is from PV(pin5) to PS(pin6). Please refter to function manual for details.
7. Please consult MEAN WELL for applications of more units connecting in parallel.
File Name:RSP-750-SPEC 2012-06-22
750W Single Output Power Supply RSP-750 series
7.8
20.5
25.4
3-M4 L=6
250
231.5
41 33.5
18.5
63.5
-V
+V
2 1 Air flow
127
90
CN50 direction
SVR51 14 13
3
7
2
10
1
3-M4 L=4
TB1
3-M4 L=6
25.4
20.5
7.8
6
236
80 80
70
60
LOAD (%)
50
LOAD (%)
60
40
50
20 40
10,11 GND These pins connect to the negative terminal (-V). Return for DC_OK Signal output.
12 G-AUX Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
13 ON/OFF Turns the output on and off by electrical or dry contact between pin 13 ( ON/OFF) and pin 14 (12V-AUX). Short: Power ON, Open: Power OFF.
Auxiliary voltage output, 10.8~13.2V, referenced to pin 12(G-AUX). The maximum load current is 0.1A. This output is not controlled by the
14 12V-AUX "remote ON/OFF control".
Function Manual
1."Remote ON/OFF" and "Output voltage trim" and "Output OLP trim" functions are not used.
The power supply unit will have no output if the shorting connector (accessory comes along with the PSU) is not assembled. It contains
three shorting wires : one is from ON/OFF (pin13) to 12V-AUX (pin14), two is from PV(pin5) to PS (pin6) and the other is from PC (pin7) to PO (pin8).
-V +V CN50 TB1
1 13
2 14
LOAD
- +
Fig 1.1
CN50
1 3 5 7 13
+S -S PV PC DC_OK GND ON/OFF
(Shorting connector)
2.Remote ON/OFF
The PSU can be turned ON/OFF by using the "Remote
ON/OFF" function
Between ON/OFF(pin13) and 12V-AUX(pin14) Output Status
SW ON (Short) ON
CN50
LOAD
- + 1 3 5 7 13
+S -S PV PC DC_OK GND ON/OFF SW
Fig 2.1
+VS -VS PS PO GND G-AUX 12V-AUX
2 4 6 8 14
3.DC_OK signal
"DC_OK" is an open collector signal.
It indicates the output status of the PSU. It can operate
in two ways : One is sinking current from external TTL
signal ; the other is sending out a TTL voltage signal.
3-1 Sink current :
The maximum sink current is 10mA and the maximum -V +V CN50 TB1
external voltage is 5.6V. 1 13
3-2 TTL voltage signal : 2 14
4.Remote Sense
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
-V +V CN50 TB1
1 13
2 14
Sense lines should
be twisted in pairs
LOAD 1 3 5 7 CN50 13
-S +S
(Pin3) + - (Pin1)
+S -S PV PC DC_OK GND ON/OFF
Fig 4.1 6 8 14
OVP 120%(Typ.)
Vout -V +V CN50 TB1
120 1 13
2 14
OUTPUT VOLTAGE (%)
100
80 Non-Linear
LOAD
60
- +
40
External Voltage
20 UVP 10%(Typ.)
Note: External voltage<0.5V Vo may be the UVP need to restart. +VS -VS PS PO GND G-AUX 12V-AUX
2 4 8 14
Fig 5.1
OLP 115%(Typ.)
OLP
120
External Voltage
OUTPUT CURRENT (%)
100 1 3 5 7 CN50 11 13
20
PC(Referenced to GND)
1 2 3 4 5 6 Fig 6.1
EXTERNAL VOLTAGE (VDC)