01-10 Cables

The document describes different types of cables used in OptiX OSN 3500/2500/1500 hardware, including fiber jumper cables, power cables, alarm cables, management cables, and signal cables. Details are provided on the structure and purpose of each cable type.

Uploaded by

SRK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 53

OptiX OSN 3500/2500/1500

Hardware Description Manual Contents

Contents

10 Cables .......................................................................................................................................10-1
10.1 Fiber Jumper............................................................................................................................ 10-1
10.1.1 Classification.................................................................................................................. 10-1
10.1.2 Connector....................................................................................................................... 10-3
10.2 Power Cable and Grounding Cable ......................................................................................... 10-5
10.2.1 Cabinet –48 V/BGND/PGND Power cable ................................................................... 10-5
10.2.2 Cabinet Door Grounding Cable ..................................................................................... 10-7
10.2.3 Subrack Power Cable ..................................................................................................... 10-8
10.2.4 Equipment –48 V/–60 V Power Cable/PGND Grounding Cable .................................. 10-9
10.2.5 HUB/COA Power Cable .............................................................................................. 10-11
10.2.6 UPM Power Cable ....................................................................................................... 10-13
10.3 Alarm Cable........................................................................................................................... 10-14
10.3.1 Cabinet Indicator Cable ............................................................................................... 10-14
10.3.2 Indicator/Alarm Concatenating Cables between OSN Subracks ................................. 10-16
10.3.3 Alarm Concatenating Cable between OSN Subrack and Other Subrack ..................... 10-17
10.3.4 Housekeeping Alarm Input/Output Cable.................................................................... 10-18
10.4 Management Cable................................................................................................................ 10-21
10.4.1 OAM Serial Port Cable ................................................................................................ 10-21
10.4.2 Serial 1–4/F1/F&f Cable.............................................................................................. 10-23
10.4.3 RS-232/422 Serial Port Cable ...................................................................................... 10-24
10.4.4 Orderwire Telephone Wire........................................................................................... 10-25
10.4.5 COA Concatenating Cable ........................................................................................... 10-26
10.4.6 Straight Through Cable ................................................................................................ 10-27
10.4.7 Crossover Cable ........................................................................................................... 10-29
10.5 Signal Cable .......................................................................................................................... 10-31
10.5.1 75 ohm 8xE1 Cable...................................................................................................... 10-31
10.5.2 75 ohm 16xE1 Cable.................................................................................................... 10-33
10.5.3 120 ohm 8xE1 Cable.................................................................................................... 10-35
10.5.4 120 ohm 16xE1 Cable.................................................................................................. 10-37
10.5.5 E3/T3/STM-1 Cable..................................................................................................... 10-40
10.5.6 Extended Subrack Service Connection Cable.............................................................. 10-41

Issue 04 (2007-04-30) Huawei Technologies Proprietary i


OptiX OSN 3500/2500/1500
Contents Hardware Description Manual

10.6 Clock Cable ........................................................................................................................... 10-43


10.6.1 Clock Cable.................................................................................................................. 10-43
10.6.2 1/2-Channel Clock Transfer Cable............................................................................... 10-45

ii Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual Figures

Figures

Figure 10-1 LC/PC optical interface............................................................................................... 10-3


Figure 10-2 SC/PC Optical interface.............................................................................................. 10-4
Figure 10-3 FC/PC optical interface............................................................................................... 10-4
Figure 10-4 E2000/APC optical interface ...................................................................................... 10-5
Figure 10-5 –48 V cabinet power cable/cabinet BGND power cable............................................. 10-6
Figure 10-6 Cabinet PGND power cable........................................................................................ 10-6
Figure 10-7 Cabinet PGND power cable........................................................................................ 10-6
Figure 10-8 Structure of the cabinet door grounding cable ............................................................ 10-8
Figure 10-9 Structure of the subrack power cable .......................................................................... 10-8
Figure 10-10 Structure of the –48 V/–60 V power cable.............................................................. 10-10
Figure 10-11 Structure of the PGND power cable........................................................................ 10-10
Figure 10-12 Structure of the HUB/COA power cable................................................................. 10-12
Figure 10-13 Structure of the subrack power cable ...................................................................... 10-13
Figure 10-14 Structure of the cabinet indicator cable................................................................... 10-14
Figure 10-15 Structure of the indicator/alarm concatenating cable between OSN subracks........ 10-16
Figure 10-16 Alarm concatenating cable between OSN subrack and other subrack .................... 10-17
Figure 10-17 Structure of the housekeeping alarm input/output cable......................................... 10-19
Figure 10-18 Structure of the OAM serial port cable ................................................................... 10-22
Figure 10-19 Structure of the serial 1–4/F1/F&f cable................................................................. 10-23
Figure 10-20 Structure of the RS-232/422 serial port cable ......................................................... 10-24
Figure 10-21 Structure of ordinary telephone wire....................................................................... 10-26
Figure 10-22 Structure of the COA concatenating serial port cable ............................................. 10-27
Figure 10-23 Structure of straight through cable.......................................................................... 10-28
Figure 10-24 Structure of the crossover cable .............................................................................. 10-29
Figure 10-25 Structure of the 75 ohm 8xE1 cable........................................................................ 10-31
Figure 10-26 Structure of the 75 ohm 16xE1 cable...................................................................... 10-33

Issue 04 (2007-04-30) Huawei Technologies Proprietary iii


OptiX OSN 3500/2500/1500
Figures Hardware Description Manual

Figure 10-27 Structure of the 120 ohm 8 x E1 cable.................................................................... 10-36


Figure 10-28 Structure of the 120 ohm 16xE1 cable.................................................................... 10-38
Figure 10-29 Structure of the E3/T3/STM-1 cable....................................................................... 10-40
Figure 10-30 Structure of the extended subrack service connection cable................................... 10-41
Figure 10-31 Structure of the 75 ohm clock cable........................................................................ 10-44
Figure 10-32 Structure of the 120 ohm clock cable...................................................................... 10-44
Figure 10-33 Structure of the 1-channel 120 ohm/75 ohm clock transfer cable........................... 10-45
Figure 10-34 Structure of the 2-channel 120 ohm/75 ohm clock transfer cable........................... 10-46

iv Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual Tables

Tables

Table 10-1 Classification of fiber jumper ....................................................................................... 10-2


Table 10-2 Classification of fiber connector................................................................................... 10-3
Table 10-3 OptiX OSN 3500/2500/1500 power cables and grounding cables ............................... 10-5
Table 10-4 Pin assignment of subrack power cable ........................................................................ 10-9
Table 10-5 Pin assignment of the –48 V/–60 V power cable........................................................ 10-10
Table 10-6 Pin assignment of the HUB power cable .................................................................... 10-12
Table 10-7 Pin assignment of the UPM power cable.................................................................... 10-13
Table 10-8 OptiX OSN 3500/2500/1500 alarm cable................................................................... 10-14
Table 10-9 Pin assignment of the cabinet indicator cable............................................................. 10-15
Table 10-10 Pin assignment of indicator/alarm concatenating cables between OSN subracks .... 10-16
Table 10-11 Pin assignment of alarm concatenating cable between OSN subrack and other subrack
....................................................................................................................................................... 10-18
Table 10-12 Pin assignment of housekeeping alarm input/output cable for OptiX OSN 3500/2500
....................................................................................................................................................... 10-19
Table 10-13 Pin assignment of housekeeping alarm input/output cable for OptiX OSN 1500 .... 10-20
Table 10-14 OptiX OSN 3500/2500/1500 management cables .................................................... 10-21
Table 10-15 Pin assignment of OAM serial port cable ................................................................. 10-22
Table 10-16 Pin assignment of the serial 1–4/F1/F&f cable......................................................... 10-23
Table 10-17 Pin assignment of the RS-232/422 serial port cable ................................................. 10-25
Table 10-18 Pin assignment of ordinary telephone wire............................................................... 10-26
Table 10-19 pin assignment of the COA concatenating serial port cable ..................................... 10-27
Table 10-20 Pin assignment of the straight through cable ............................................................ 10-28
Table 10-21 Pin assignment of crossover cable ............................................................................ 10-30
Table 10-22 OptiX OSN 3500/2500/1500 signal cables............................................................... 10-31
Table 10-23 Pin assignment of the 75 ohm 8xE1 cable ................................................................ 10-32
Table 10-24 Pin assignment of the 75 ohm 16xE1 cable .............................................................. 10-34

Issue 04 (2007-04-30) Huawei Technologies Proprietary v


OptiX OSN 3500/2500/1500
Tables Hardware Description Manual

Table 10-25 Pin assignment of the 120 ohm 8 x E1 cable ............................................................ 10-36
Table 10-26 Pin assignment of the 120 ohm 16xE1 cable ............................................................ 10-38
Table 10-27 Pin assignment of the extended subrack service connection cable........................... 10-42
Table 10-28 OptiX OSN 3500/2500/1500 clock cables................................................................ 10-43
Table 10-29 Pin assignment of the 120 ohm clock cable.............................................................. 10-44
Table 10-30 Pin assignment of the 75 ohm/120 ohm clock transfer cable ................................... 10-46

vi Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

10 Cables

This chapter describes the cables in the following aspects: cable classification,
cable structure, connector, and pin assignment. Cables used by the OptiX OSN
3500, OptiX OSN 2500, OptiX OSN 2500REG and OptiX OSN 1500 include:
„ Fiber jumper
„ Power cable and grounding cable
„ Alarm cable
„ Management cable
„ Clock cable
„ Signal cable

10.1 Fiber Jumper


10.1.1 Classification
The fiber jumpers used by the OptiX OSN 3500 are classified as shown in Table
10-1.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-1


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Table 10-1 Classification of fiber jumper


Usage Connector 1 Connector 2 Cable Length

Optical fiber LC/PC FC/PC 2 mm 6 m, 10 m, 20 m, 30 m,


connecting OSN single-mode 50 m
equipment to the ODF fiber
or other equipment
2 mm multi 3 m, 5 m, 10 m, 20 m,
–mode optical 30 m, 50 m
fiber
LC/PC SC/PC 2 mm 5 m, 10 m, 20 m, 30 m,
single-mode 50 m
optical fiber
2 mm 10 m, 20 m, 30 m, 50
multi-mode m
optical fiber
SC/PC SC/PC 3 mm 2 m, 5 m, 10 m, 20 m,
single-mode 30 m, 50 m, 80 m
optical fiber
Optical fiber LC/PC LC/PC 2 mm 1.5 m, 3 m, 5 m, 10 m,
connecting OSN single-mode 20 m, 30 m
equipments optical fiber
2 mm 3 m, 5 m, 10 m, 20 m,
multi-mode 30 m
optical fiber
LC/PC FC/PC 2 mm SLM 6 m, 10 m, 20 m, 30 m,
optical fiber 50 m
LC/PC SC/PC 2 mm 5 m, 10 m, 20 m, 30 m,
single-mode 50 m
optical fiber

Select fiber connector and fiber length according to the on-site survey. The OptiX
OSN 3500/2500/1500 uses LC/PC fiber connector (SC/PC for the N2OU08 board).
The "IN" interface on the externally-installed 62COA uses E2000/APC connector.
The "IN" interface on the externally-installed 61COA uses SC/PC connector.

Caution
Multi-transverse mode optical transmitting module needs to be connected to
multi-mode fiber; the single-longitudinal mode or multi-longitudinal mode optical
transmitting module needs to be connected to single-mode fiber.

10-2 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

10.1.2 Connector
Most optical interfaces on the OptiX OSN 3500/2500/1500 board front panel are of
LC/PC type, as shown in Figure 10-1. The N2OU08 board provides SC/PC optical
interface. The "IN” interface of the externally-installed 62COA uses E2000/APC
connector, as shown in Figure 10-4.
On the client-side ODF, the FC/PC or SC/PC optical interface is used. The matched
FC/PC and SC/PC connectors are shown in Figure 10-3 and Figure 10-2
respectively. The four types of connector are described in Table 10-2.

Table 10-2 Classification of fiber connector


Internal fiber connector Description

LC/PC Plug-in square fiber connector/protruding polished


E2000/APC Connector with dust-proof cover/protruding polished (8°)
FC/PC Round fiber connector/protruding polished
SC/PC Square fiber connector/protruding polished

LC/PC Optical Interface


The appearance of the LC/PC optical interface is shown in Figure 10-1.

Figure 10-1 LC/PC optical interface

The plugging/unplugging of LC/PC optical interface only needs axial operation


instead of rotation.
When inserting the fiber jumper with LC/PC connector, be careful to align the head
of the fiber jumper with the optical interface on the optical board and push in the
fiber with proper strength. When pulling it out, press the clip first, then push fiber
connector inward slightly, and then pull out the connector.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-3


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

SC/PC Optical Interface


The appearance of the SC/PC optical interface is shown in Figure 10-2.

Figure 10-2 SC/PC Optical interface

FC/PC Optical Interface


The appearance of the FC/PC optical interface is shown in Figure 10-3.

Figure 10-3 FC/PC optical interface

E2000/APC Optical Interface


The appearance of the E2000/APC optical interface is shown in Figure 10-4.

10-4 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Figure 10-4 E2000/APC optical interface

10.2 Power Cable and Grounding Cable


The OptiX OSN 3500/2500/1500 power cables and grounding cables are listed in
Table 10-3.

Table 10-3 OptiX OSN 3500/2500/1500 power cables and grounding cables
OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

Cabinet –48V/BGND/PGND Cabinet –48V/BGND/PGND Cabinet


power cable power cable –48V/BGND/PGND
power cable
Cabinet door grounding Cabinet door grounding -
cable cable
Subrack power cable Subrack power cable Equipment –48 V/-60
V power cable/PGND
power cable
HUB/COA power cable HUB/COA power cable -
- UPM power cable UPM power cable

10.2.1 Cabinet –48 V/BGND/PGND Power cable


–48 V, BGND and PGND power cables are used for supplying power to the
equipment in the cabinet. One end of the power cable connects to the power
distribution cabinet and grounding bar in the equipment room, and the other end
connects to the power distribution unit at the cabinet top.

Structure
The structure of the –48 V cabinet power cable/BGND power cable is shown in
Figure 10-5. The PGND power cable is shown in Figure 10-6 and Figure 10-7.The
types of naked connector in Figure 10-6 and Figure 10-7 are different from each
other.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-5


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1 2

1. Cord end terminal 2. Naked connector-OT type 3. Cable tie


Figure 10-5 –48 V cabinet power cable/cabinet BGND power cable

1. Naked connector-OT type 2. Cable tie 3. Naked connector(JG2)


4. Heat-shrink tube 5. Main tag 6. Wire
7. Heat-shrink tube
Figure 10-6 Cabinet PGND power cable

1. Naked connector-OT type 2. Cable tie 3. Naked connector(OT type)


4. Heat-shrink tube 5. Main tag 6. Wire
7. Heat-shrink tube
Figure 10-7 Cabinet PGND power cable

10-6 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Pin Assignment
None

Technical Parameters
Item Description

–48 V cabinet Connector 2 Naked crimping terminal-OT type-16 mm2-M8-tin


power cable plating-naked ring terminal
Connector 1 Single cord end terminal-16 mm2-length 24
mm-inserted 12 mm deep-80A-green
Cable type Power cable-450 V/750 V-16 mm2-round and
bllue-85A
Cabinet Connector 2 Naked crimping terminal-OT type-16 mm2-M8-tin
BGND plating-naked ring terminal
grounding
cable Connector 1 Single cord end terminal-16 mm2-24 mm-inserted
12 mm deep-80A-green
Cable type Power cable-450 V/750 V-16 mm2-round and
black-85A
Cabinet Connector 1 Naked crimping terminal-OT type-16 mm2-M8-tin
PGND plating-naked ring terminal
grounding
cable Connector 3 Naked crimping connector-JG2-16
mm2-M6-95A-tin plating, or
Naked crimping connector-JG2-16
mm2-M8-95A-tin plating, or
Naked crimping terminal-OT type-16 mm2-M8-tin
plating-naked ring terminal
Cable type Power cable-450 V/750 V-16 mm2-yellow and
green-85A
Fireproof level CM
Length 10 m, 20 m, 30 m

10.2.2 Cabinet Door Grounding Cable


The cabinet door grounding cable grounds the front door, rear door and side panels.
This cable is installed before delivery.

Structure
The structure of the cabinet door grounding cable is shown in Figure 10-8.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-7


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1. Naked connector--OT type 2. Heat-shrink tube 3. Main tag


Figure 10-8 Structure of the cabinet door grounding cable

Pin Assignment
None

Technical Parameters
Item Description

Connector X1/X2 Naked crimping terminal-OT-6mm2-M6-tin


plating-insulated ring terminal-12~10AWG
Cable Model Wire-600 V-UL1015-10AWG-50A-yellow and green
Fireproof level CM
Length 0.35 m

10.2.3 Subrack Power Cable


The subrack power cable connects the power distribution unit at the cabinet top and
the PIU board on the subrack, leading the –48 V power supply from the top of the
cabinet to subrack. This cable is installed before delivery.

Structure
The structure of the subrack power cable is shown in Figure 10-9.

1. Cable connector 2. Main tag 3. Cable tie 4. Tag 5. Cord end terminal
Figure 10-9 Structure of the subrack power cable

10-8 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Pin Assignment
The pin assignment of the subrack power cable is shown in Table 10-4.

Table 10-4 Pin assignment of subrack power cable


Cable connector Naked Relation Core color
connector

X1.A1 X2 A1 connects to X2 Blue (–48 V power)


X1.A3 X3 A3 connects to X3 Black (power ground)

Technical Parameters
Item Parameter

Cable connector X1 Cable connector-D type-3PIN-female


Naked connector X2/X3 Single cord end terminal-4 mm2-20A-insertion depth
10mm-gray
Cable Model Power cable-600 V-0 mm2-12AWG-balck (the core is
blue and black)-41A
Number of 2
cores
Fireproof level CM
Color Blue or black
Length 2.5 m, 3 m, 3.5 m

10.2.4 Equipment –48 V/–60 V Power Cable/PGND Grounding


Cable
The –48 V/–60 V power cable and grounding cable connects –48 V/–60 V power
supply to the PIU board of the OptiX OSN 1500 to access –48 V/–60 V power to the
equipment.

Structure
The structure of the –48 V/–60 V power cable is shown in Figure 10-10 and that of
the PGND grounding cable is shown in Figure 10-11.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-9


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

A3
A
A2

A1

Figure 10-10 Structure of the –48 V/–60 V power cable

1. Naked connector-OT type 2. Cable tie 3. Naked connector 4. Heat-shrink tube


5. Main tag 6. Wire 7. Heat-shrink tube
Figure 10-11 Structure of the PGND power cable

Pin Assignment
The pin assignment of the –48 V/–60 V power cable is shown in Table 10-5.

Table 10-5 Pin assignment of the –48 V/–60 V power cable


Cable connector Cable Core color

A1 W1 Blue (–48 V/–60 power)


A3 W2 Black (power ground)

10-10 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Technical Parameters
–48 V/–60 V power cable PGND grounding cable

Cable connector Cable connector-D Naked connector-OT-6mm2-M4-tin


type-3PIN-female plating-round insulated conennctor-12 to
10AWG
Naked connector-OT-6mm2-M8-tin
plating-round insulated conennctor-12 to
10AWG
Cable Model Wire-300 V-16AWG-black(the Wire-600 V-10AWG-yellow/green-50A
core is blue and black)-13A
Number of 2 1
cores
Fireproof level CM CM
Color Blue and black Yellow and green
Length 15 m, 30 m 15 m, 30 m

10.2.5 HUB/COA Power Cable


The OptiX OSN 3500/2500 PIU board can supply power to external equipment
(such as COA or HUB). The HUB/COA power cable connects power port on the
PIU and the power port of external equipment.
Both ends of the HUB/COA power cable use 4PIN connector, with one end
connected to the PIU board and the other end to the power port of external
equipment (HUB or COA).

Structure
The structure of the HUB/COA power cable is shown in Figure 10-12.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-11


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1
A-A A 3
B
3 1 W1

4 2 X1
A 2

W2 X3

X2

W1.1
W1
B W1.2 X3
W2.1

W2
W2.2

1. Common connector-female 2. Plug-4PIN 3. Main tag


A-A. Sectional view in A direction
Figure 10-12 Structure of the HUB/COA power cable

Pin Assignment
The pin assignment of the HUB/COA power cable is shown in Table 10-6.

Table 10-6 Pin assignment of the HUB power cable


Connector X1, X2 Cable W1, W2 Color Connector X3

X1.1 W1.1 Brown X3.1


X2.1 W2.1
X1.3 W1.2 Black X3.3
X2.3 W2.2

Technical Parameters
Item Description

Connector X3 Common plug-4 PIN-double rows/4.20 mm


Connector X1/X2 Common terminal-female-4PIN-18/26AWG-13.7 mm in
length
W1/W2 cable model Twisted pair-UL2464-0.64mm-22AWG-1 pair-black
Number of cores 2
Fireproof level CM
Color Black

10-12 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Item Description

Length 1.8 m

10.2.6 UPM Power Cable


Structure
The structure of the power cable connecting UPM to the OptiX OSN 2500/1500 is
shown in Figure 10-13.
A

B
A1 A B 1
A2 2
A3

X1 X2

Figure 10-13 Structure of the subrack power cable

Pin Assignment
The pin assignment of the UPM power cable is shown in Table 10-7.

Table 10-7 Pin assignment of the UPM power cable


Cable connector X1 Cable Cable connector X2 Core color

A1 W1 1 Blue (–48 V/–60 V


power)
A3 W2 2 Black (power ground)

Technical Parameters
Item Parameter

Cable connector X1 Cable connector-D-spin-female (2 female, 1 male)


Common connector X2 Common terminal-2PIN-single row
Cable Model Power cable-300 V-1.31 mm2-16AWG-black (the core is
blue and black)-13A
Number of 2
cores
Fireproof level CM

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-13


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Item Parameter

Color The color of the core is blue or black


Length 2.5 m

10.3 Alarm Cable


The OptiX OSN 3500/2500/1500 alarm cables are listed in:

Table 10-8 OptiX OSN 3500/2500/1500 alarm cable


OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

Cabinet indicator cable Cabinet indicator cable -


Indicator/Alarm Indicator/Alarm concatenating -
concatenating cable between cable between OSN subracks
OSN subracks
Alarm concatenating cable Alarm concatenating cable -
between OSN subrack and between OSN subrack and
other subrack other subrack
Housekeeping alarm Housekeeping alarm Housekeeping alarm
input/output cable input/output cable input/output cable

10.3.1 Cabinet Indicator Cable


The cabinet indicator cable is used to connect the AUX board on the subrack to the
cabinet indicator, leading out the indicator signal from the AUX to the cabinet
indicator.

Structure
The structure of the cabinet indicator is shown in Figure 10-14.

X2

X3

X1
X4

X5

A-A. Sectional view in A direction B-B. Sectional view in B direction


Figure 10-14 Structure of the cabinet indicator cable

10-14 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Pin Assignment
The pin assignment of the cabinet indicator cable is shown in Table 10-9.

Table 10-9 Pin assignment of the cabinet indicator cable


Connector X1 Connector Relationship Label print
X2,/X3/ X4/ X5

X1.4 X2.2 Pair Green


X1.5 X2.1
X1.1 X3.2 Pair Red
X1.2 X3.1
X1.3 X4.2 Pair Orange
X1.6 X4.1
X1.7 X5.2 Pair Yellow
X1.8 X5.1

Technical Parameters
Item Description

Connector X1 Network interface connector-8PIN-8bit-shielded-crystal model


connector
Connector Common connector -2PIN-single row/2.5 mm
X2/X3/X4/X5
Cable model Twisted pair cable-120 ohm-SEYPVPV-0.5 mm-24AWG-8
cores-PANTONE 430U
Number of cores 8
Fireproof level CM
Core diameter 0.5 mm
Length 2.5 m, 3 m, 3.5 m

10.3.2 Indicator/Alarm Concatenating Cables between OSN


Subracks
The indicator/alarm concatenating cables between subracks respectively
concatenates indicator and alarm signals of the OSN subracks in one cabinet or
different cabinet. Both ends of the cable uses RJ-45 connector, with one end

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-15


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

connected to LAMP1 or ALMO2 interface of one subrack and the other end to
LAMP2 or ALMO1 interface of another subrack.

Structure
The structure of the indicator/alarm concatenating cables between OSN subracks is
shown in Figure 10-15.

1. Network port connector – RJ-45 2. Main tag A-A. Sectional view in A direction
Figure 10-15 Structure of the indicator/alarm concatenating cable between OSN subracks

Pin Assignment
The pin assignment of the indicator/alarm concatenating cables between OSN
subracks is shown in Table 10-10.

Table 10-10 Pin assignment of indicator/alarm concatenating cables between OSN subracks
Connector X1 Connector X2 Relationship Alarm output

X1.1 X2.1 Pair EMERGENCY ALARM +


X1.2 X2.2 EMERGENCY ALARM -
X1.3 X2.3 Pair MAIN ALARM +
X1.6 X2.6 MAIN ALARM -
X1.4 X2.4 Pair AUXILIARY ALARM 1+
X1.5 X2.5 AUXILIARY ALARM 1-
X1.7 X2.7 Pair AUXILIARY ALARM 2+
X1.8 X2.8 AUXILIARY ALARM 2-

Technical Parameters
Item Description

Connector X1/X2 Network interface connector-8PIN-8bit-shielded-crystal model


connector

10-16 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Item Description

Cable model Twisted pair-120 ohm-SEYPVPV-0.5 mm-24AWG-8


cores-PANTONE 430U
Number of cores 8
Fireproof level CM
Core diameter 0.5 mm
Length 3 m, 5 m, 10 m, 20 m

10.3.3 Alarm Concatenating Cable between OSN Subrack and


Other Subrack
The alarm concatenating cable between OSN subrack and other subrack is used to
concatenate the signals output/input from/to the OptiX OSN equipment and non
OSN series transmission equipment (such as OptiX 2500+, etc) of Huawei. One
end of the cable uses RJ-45 connector, connected to ALMO1 or ALMO2 interface
of the subrack and the other end to the alarm concatenating interface of other
equipment.

Structure
The structure of the alarm concatenating cable between OSN subrack and other
subrack is shown in Figure 10-16.

1. Network port connector - RJ45 2. Main tag 3. Tag 1 4. Cable connector-D type 9
PINs-female
L: 5 m, 10 m, 20 m
Figure 10-16 Alarm concatenating cable between OSN subrack and other subrack

Pin Assignment
The pin assignment of the alarm concatenating cable between OSN subrack and
other subrack is shown in Table 10-11.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-17


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Table 10-11 Pin assignment of alarm concatenating cable between OSN subrack and other
subrack
Connector X1 Connector X2 Relationship Relationship

X1.1 X2.7 Pair EMERGENCY ALARM +


X1.2 X2.3 EMERGENCY ALARM -
X1.3 X2.6 Pair MAIN ALARM +
X1.6 X2.1 MAIN ALARM -

Technical Parameters
Item Description

Connector X1 Network interface connector-8PIN-8bit-shielded-crystal model


connector
ConnectorX2 Cable connector-D type-9PIN-female
Cable model Twisted pair-100 ohm-SEYVP-0.48 mm-26AWG-4 cores-BLACK
Number of cores 4
Fireproof level CM
Core diameter 0.5 mm
Length 5 m, 10 m, 20 m

10.3.4 Housekeeping Alarm Input/Output Cable


The housekeeping alarm input cable inputs the alarm signal of the external
equipment into the OptiX OSN 3500/2500/1500 and the output cable outputs the
alarm signal of the OptiX OSN 3500/2500/1500 to the centralized alarm
monitoring equipment.
One end of the housekeeping alarm input/output cable connects to the
housekeeping alarm input/output interface through an RJ-45 connector and the
other end connects to the external equipment or the centralized alarm monitoring
equipment. Make the connector following the on-site requirements. Each cable can
provide 4 channels transmission for housekeeping alarm.

Structure
The structure of the housekeeping alarm input/output cable is shown in Figure
10-17.

10-18 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

1. Network port connector – RJ-45 2. Main tag A-A. Sectional view in A direction
Figure 10-17 Structure of the housekeeping alarm input/output cable

Pin Assignment
„ OptiX OSN 3500 provide house-keeping alarm interface for 16 inputs and 4
outputs.
„ OptiX OSN 2500 provide house-keeping alarm interface for 8 inputs and 4
outputs.
„ OptiX OSN 1500 provide house-keeping alarm interface for three inputs and
one output.
So the pin assignment of the housekeeping alarm input/output cable for OptiX OSN
3500/2500 is shown in Table 10-12 and that for OptiX OSN 1500 is shown in Table
10-13.

Table 10-12 Pin assignment of housekeeping alarm input/output cable for OptiX OSN
3500/2500
Connector Color Relationship Alarm output Alarm input
X1

X1.1 Blue Pair CRITICAL AND SW_INPUT 1+


MAJOR ALARM
SIGNAL +
X1.2 White CRITICAL AND SW_INPUT 1-
MAJOR ALARM
SIGNAL -
X1.3 Orange Pair MINOR OR SW_INPUT 2+
WARNING ALARM
SIGNAL +
X1.6 White MINOR OR SW_INPUT 2-
WARNING ALARM
SIGNAL -
X1.4 Green Pair AUXILIARY SW_INPUT 3+
ALARM 1+

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-19


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Connector Color Relationship Alarm output Alarm input


X1

X1.5 White AUXILIARY SW_INPUT 3-


ALARM 1-
X1.7 Brown Pair AUXILIARY SW_INPUT 4+
ALARM 2+
X1.8 White AUXILIARY SW_INPUT 4-
ALARM 2-

Table 10-13 Pin assignment of housekeeping alarm input/output cable for OptiX OSN 1500
Connector Color Relationship Alarm output Alarm input
X1

X1.1 Blue Pair - SW_INPUT 1+


X1.2 White - SW_INPUT 1-
X1.3 Orange Pair - SW_INPUT 2+
X1.6 White - SW_INPUT 2-
X1.4 Green Pair - SW_INPUT 3+
X1.5 White - SW_INPUT 3-
X1.7 Brown Pair SW_OUT1+ -
X1.8 White SW_OUT1- -

Technical Parameters
Item Description

ConnectorX1 Network interface connector-8PIN-8bit-shielded-crystal model


connector
Cable model OptiX OSN 3500/2500: Twisted pair-120 ohm-SEYPVPV-0.5
mm-24AWG-8 cores-PANTONE 430U
OptiX OSN 1500: Twisted pair-100±15 ohm-shielded CAT5E
SFTP-24AWG-8 cores-PANTONE445U
Number of cores 8
Fireproof level CM
Core diameter OptiX OSN 3500/2500: 0.5 mm
OptiX OSN 1500: 0mm

10-20 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Item Description

Length 10 m, 20 m, 30 m

10.4 Management Cable


The OptiX OSN 3500/2500/1500 management cables are listed in Table 10-14.

Table 10-14 OptiX OSN 3500/2500/1500 management cables


OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

OAM serial port cable OAM serial port cable OAM serial port cable
Serial1–4/F&f serial port Serial1–4/F&f serial Serial1–4/F&f serial port
cable port cable cable
RS-232/422 serial port RS-232/422 serial port RS-232/422 serial port cable
cable cable
Ordinary telephone wire Ordinary telephone wire Ordinary telephone wire
COA concatenating cable COA concatenating COA concatenating cable
cable
Straight through cable Straight through cable Straight through cable
Crossover cable Crossover cable Crossover cable

10.4.1 OAM Serial Port Cable


The OAM serial port cable is used for management and remote maintenance of the
OptiX OSN 3500. One end of the cable uses RJ-45 connector, connected to the
OAM interface. The other end uses DB25 or DB9 connector, connected to the
laptop computer, serial NM or modem.

Structure
Figure 10-18 takes DB25 as example to show the structure of the OAM serial port
cable.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-21


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1. Network port connector – RJ-45 2. Main tag 3. Cable connector-DB25 male


A-A. Sectional view in A direction
B-B. Sectional view in B direction
Figure 10-18 Structure of the OAM serial port cable

Pin Assignment
The pin assignment of the OAM serial port cable is shown in Table 10-15.

Table 10-15 Pin assignment of OAM serial port cable


Connector X1 Connector X2 Relationship Function

X1.2 X2.20 Single DTR (Data Terminal Ready)


X1.3 X2.2 Single TD (Transmit Data)
X1.6 X2.3 Single RD (Receive Data)
X1.4 X2.7 Pair SG (Signaling Ground)
X1.5

Technical Parameters
Item Description

Connector X1 Network interface connector-8PIN-8bit-shielded-crystal model


connector
ConnectorX2 Cable connector-D type-25PIN-male or Cable connector-D
type-9PIN-male
Cable model Twisted pair-120 ohm-SEYPVPV-0.5 mm-24AWG-8
cores-PANTONE 430U
Number of cores 8
Fireproof level CM
Length 5m

10-22 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

10.4.2 Serial 1–4/F1/F&f Cable


The serial 1~4/F1/F&f cable is used for:
„ transparent transmission of environment detection data signal
„ management of external devices like COA
„ management of the UPM
One end of the cable uses RJ-45 connector, connected to serial 1–4 interfaces, F1 or
F&f serial interface, and the other end uses DB9 connector, connected to external
detection equipment or external equipment.

Structure
The structure of the Serial S1–S4/F1/F&f cable is shown in Figure 10-19.

1. Network port connector – RJ-45 2. Main tag 3. Cable connector-DB9 male


A-A. Sectional view in A direction
B-B. Sectional view in B direction
Figure 10-19 Structure of the serial 1–4/F1/F&f cable

Pin Assignment
The pin assignment of the Serial 1–4/F1/F&f cable is shown in Table 10-16.

Table 10-16 Pin assignment of the serial 1–4/F1/F&f cable


Connector X1 Connector X2 Relationship Function

X1.1 X2.8 Pair RS-422RX +


X1.2 X2.9 RS-422RX -
X1.3 X2.6 Pair RS-422TX +
X1.6 X2.7 RS-422TX -
X1.4 X2.3 Pair RS-232RX
X1.8 X2.2 RS-232TX

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-23


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Connector X1 Connector X2 Relationship Function

X1.5 X2.5 Single SG

Technical Parameters
Item Description

Connector X1 Network interface connector-8PIN-8bit-shielded-crystal model


connector
ConnectorX2 Cable connector-D type-9PIN-male
Cable model (1) Twisted pair-120 ohm-SEYPVPV-0.5 mm-24AWG-8
cores-PANTONE 430U
(2) Twisted pair-100 ohm-SEYVP-0.48 mm-26AWG-8 cores-black
Number of 8
cores
Fireproof level CM
Length Cable (2) is 3 m and cable (1) is 15 m

10.4.3 RS-232/422 Serial Port Cable


The RS-232/422 serial port cable is used to transmission management signaling
between different subnets. Both ends use RJ45 connector. One end is connected to
the RS-232/422 serial port, and the other end to the RS-232/422 serial port of other
NE.

Structure
The structure of the RS232/422 serial port cable is shown in Figure 10-20.

1. Network port connector – RJ-45 2. Main tag


A-A. Sectional view in A direction
Figure 10-20 Structure of the RS-232/422 serial port cable

10-24 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Pin Assignment
The pin assignment of the RS232/422 serial port cable is shown in Table 10-17.

Table 10-17 Pin assignment of the RS-232/422 serial port cable


Connector X1 Connector X2 Relationship Function

X1.3 X2.1 Pair RX +


X1.6 X2.2 RX -
X1.1 X2.3 Pair TX +
X1.2 X2.6 TX -
X1.5 X2.5 Pair SG
X1.4 X2.8 232RX
X1.8 X2.4 Single 232TX

Technical Parameters
Item Description

Connector X1/X2 Network interface connector-8PIN-8bit-shielded-crystal model


connector
Model Twisted pair-120 ohm-SEYPVPV-0.5 mm-24AWG-8
cores-PANTONE 430U
Number of cores 8
Fireproof level CM
Length 15 m

10.4.4 Orderwire Telephone Wire


The telephone wire is used to connect the orderwire phone. Both ends use RJ-11
connector. One end is connected to the PHONE interface and the other end to the
interface of the orderwire phone.

Structure
The structure of the ordinary telephone wire is shown in Figure 10-21.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-25


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1. Phone connector-RJ-11crystal plug 2. Main tag


Figure 10-21 Structure of ordinary telephone wire

Pin Assignment
The pin assignment of the ordinary telephone wire is shown in Table 10-18.

Table 10-18 Pin assignment of ordinary telephone wire


Connector X1 Connector X2 Function

X1.1 X2.1 No connected


X1.2 X2.2 No connected
X1.3 X2.3 TIP
X1.4 X2.4 RING
X1.5 X2.5 No connected
X1.6 X2.6 No connected

Technical Parameters
Item Description

Connector X1/X2 Network interface connector-6PIN-26 to 28AWG


Cable model Power cable-150 V-UL20251-0.08
mm2-28AWG-black-1A-2-core telephone wire
Number of cores 2
Fireproof level CM
Length 15 m

10.4.5 COA Concatenating Cable


When multiple COAs are installed in the cabinet, the RS-232/422 serial port is
required to concatenate them. Both ends of the cable use DB9 connector, connected
to the RS232-1 serial port of one COA and the RS232-2 serial port of another COA.

10-26 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Structure
The structure of the COA concatenating serial port cable is shown in Figure 10-22.

1. Cable connector-DB9 male 2. Main tag


Figure 10-22 Structure of the COA concatenating serial port cable

Pin Assignment
The pin assignment of the COA concatenating serial port cable is shown in Table
10-19.

Table 10-19 pin assignment of the COA concatenating serial port cable
Connector X1 Connector X2 Remark

3 2 A pair
2 3
5 5 Grounding

Technical Parameters
Item Description

Connector X1/X2 Cable connector-D type-9PIN-male


Cable model Twisted pair-100 ohm-UL2464-0.32 mm-28AWG-2P-grey
Number of cores 2 pairs
Fireproof level CM
Length 0.6 m, 2.5 m

10.4.6 Straight Through Cable


The straight through cable is used in many ways, including:

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-27


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

„ Connect the OptiX OSN 3500/2500/1500 and HUB.


„ Connect HUB and NM computer
„ Connect the Ethernet interface board and Ethernet equipment
Both ends of the straight through cable use RJ-45 connector which connects the
equipment at two ends respectively.

Structure
The structure of the straight through cable is shown in Figure 10-23.

1. Network port connector – RJ-45 2. Tag 1 3. Main tag 4. Tag 2


Figure 10-23 Structure of straight through cable

Pin Assignment
The pin assignment of the straight through cable is shown in Table 10-20.

Table 10-20 Pin assignment of the straight through cable


Connector X1 Connector X2 Relationship

X1.2 X2.2 Pair


X1.1 X2.1
X1.6 X2.6 Pair
X1.3 X2.3
X1.4 X2.4 Pair
X1.5 X2.5
X1.8 X2.8 Pair
X1.7 X2.7

10-28 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Technical Parameters
Item Description

Connector X1/X2 Network interface connector-crystal model


connector-8PIN-8bit-shielded-24 to 26AWG-CAT 6/used with
SFTP network cable
Cable model Communication cable-100±15 ohm-CAT5E-SFTP 24AWG-8
cores-PANTONE 445U
Number of cores 8
Fireproof level CM
Length 5 m, 10 m, 20 m, 30 m

10.4.7 Crossover Cable


The crossover cable is used to connect the NM computer to the OptiX OSN
3500/2500/1500. Both ends of the cable use RJ-45 connector. One end is connected
to the ETH interface, and the other end to the network port of the compute.

Structure
The structure of the crossover cable is shown in Figure 10-24.

1. Network port connector RJ-45 2. Tag 1 3. Main tag 4. Network cable 5. Tag 2
Figure 10-24 Structure of the crossover cable

Pin Assignment
The pin assignment of the crossover cable is shown in Table 10-21.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-29


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Table 10-21 Pin assignment of crossover cable


Connector X1 Connector X2 Relationship

X1.6 X2.2 Pair


X1.3 X2.1
X1.2 X2.6 Pair
X1.1 X2.3
X1.4 X2.4 Pair
X1.5 X2.5
X1.8 X2.8 Pair
X1.7 X2.7

Technical Parameters
Item Description

Connector X1/X2 Network interface connector-crystal model


connector-8PIN-8bit-shielded-24 to 26AWG-CAT 6/used with
SFTP network cable
Model Communication cable-100±15ohm-CAT5E-SFTP-24AWG-8
cores PANTONE 646U
Number of cores 8
Fireproof level CM
Length 5 m, 30 m

10-30 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

10.5 Signal Cable


The OptiX OSN 3500/2500/1500 signal cables are listed in Table 10-22.

Table 10-22 OptiX OSN 3500/2500/1500 signal cables


OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

75 ohm E1 cable 75 ohm E1 cable 75 ohm E1 cable


120 ohm E1 cable 120 ohm E1 cable 120 ohm E1 cable
E3/T3/STM-1 cable E3/T3/STM-1 cable E3/T3/STM-1 cable

Extended subrack service - -


connection cable

10.5.1 75 ohm 8xE1 Cable


The 75 ohm 8xE1 cable, used to input/output E1 signal, connects to the interface on
the D75S interface board. One end uses DB44 connector, connected to the 75 ohm
E1 interface board. The other end is connected to DDF. The connector needs to be
made as required. Each cable can transmit eight E1 signals.

Structure
The structure of the 75 ohm 8xE1 cable is shown in Figure 10-25.

1. Cable connector-D type-44PIN-male 2. Tag 1, marked: ‘W1 (E1:1 to 4)’


3. Tag 3, marked: ‘W2 (E1:5 to 8)’ 4. Main tag
Figure 10-25 Structure of the 75 ohm 8xE1 cable

Pin Assignment
The pin assignment of the 75 ohm 8xE1 cable is shown in Table 10-23.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-31


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Table 10-23 Pin assignment of the 75 ohm 8xE1 cable


PIN of Cable W1 Remark PIN of Cable W2 Remark
DB44 DB44
Core Series NO. Core Series
NO.

38 Ring 1 R1 34 Ring 1 R5
23 Tip 19 Tip
37 Ring 3 R2 33 Ring 3 R6
22 Tip 18 Tip
36 Ring 5 R3 32 Ring 5 R7
21 Tip 17 Tip
35 Ring 7 R4 31 Ring 7 R8
20 Tip 16 Tip
15 Ring 2 T1 11 Ring 2 T5
30 Tip 26 Tip
14 Ring 4 T2 10 Ring 4 T6
29 Tip 25 Tip
13 Ring 6 T3 9 Ring 6 T7
28 Tip 24 Tip
12 Ring 8 T4 8 Ring 8 T8
27 Tip 7 Tip
Shell Out braid of whole cable & ring of Shell Out braid of whole cable & ring of
each coax each coax

10-32 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Technical Parameters
Item Description

Connector X Cable connector-D type-44PIN-male


Cable model Coaxial cable-SYFVZP-75-1-1x8(A)-75 ohm-9.65 mm-1.2
(W1/W2) mm-0.252 mm-white
Fireproof level CM
Number of cores 8 x E1
Diameter cover diameter 9.65mm-insulation diameter 1.2mm-conductor
diameter 0.252mm
Length 3 m, 10 m, 15 m, 20 m, 25 m, 30 m, 40 m

Caution
The pin assignment table of the E1 cable is put in one packing case with the cable.
Be sure not to discard it before installation

10.5.2 75 ohm 16xE1 Cable


The 75 ohm 16xE1 cable, used to input/output E1 signal, connects to the interface
on the L75S interface board. One end uses 2 mm HM connector, connected to the
75 ohm E1 interface board L75S. The other end is connected to DDF. The
connector needs to be made as required. Each cable can transmit 16 E1 signals.

Structure
The structure of the 75 ohm 16xE1 cable is shown in Figure 10-26.

Main tag

1. Cable connector 2. Terminal


Figure 10-26 Structure of the 75 ohm 16xE1 cable

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-33


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Pin Assignment
The pin assignment of the 75 ohm 8xE1 cable is shown in Table 10-24.

Table 10-24 Pin assignment of the 75 ohm 16xE1 cable


Plug X Cable W Remark Plug X Cable W Remark

Core Series No. Core Series


No.

a1 Tip 1 R1 a10 Tip 17 R9


a2 Ring a11 Ring
a3 Tip 2 T1 a12 Tip 18 T9
a4 Ring a13 Ring
a6 Tip 3 R2 a15 Tip 19 R10
a7 Ring a16 Ring
a8 Tip 4 T2 a17 Tip 20 T10
a9 Ring a18 Ring
b1 Tip 5 R3 b10 Tip 21 R11
b2 Ring b11 Ring
b3 Tip 6 T3 b12 Tip 22 T11
b4 Ring b13 Ring
b6 Tip 7 R4 b15 Tip 23 R12
b7 Ring b16 Ring
b8 Tip 8 T4 b17 Tip 24 T12
b9 Ring b18 Ring
c1 Tip 9 R5 c10 Tip 25 R13
c2 Ring c11 Ring
c3 Tip 10 T5 c12 Tip 26 T13
c4 Ring c13 Ring
c6 Tip 11 R6 c15 Tip 27 R14
c7 Ring c16 Ring
c8 Tip 12 T6 c17 Tip 28 T14
a9 Ring c18 Ring
d1 Tip 13 R7 d10 Tip 29 R15

10-34 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Plug X Cable W Remark Plug X Cable W Remark

Core Series No. Core Series


No.

d2 Ring d11 Ring


d3 Tip 14 T7 d12 Tip 30 T15
d4 Ring d13 Ring
d6 Tip 15 R8 d15 Tip 31 R16
d7 Ring d16 Ring
d8 Tip 16 T8 d17 Tip 32 T16
d9 Ring d18 Ring

Technical Parameters
Item Description

Connector X 2 mm HM cable
connector-4x18PIN-28-30AWG-press-fit
Cable model (W1/W2) Coaxial cable-SYFVZP-75-1-1x32(A)-75 ohm-18
mm-1.2 mm-0.254 mm-Huawei gray
Fireproof level CM
Number of cores 16 x E1
Cover diameter-insulation 18 mm-1.2 mm-0.254 mm
diameter-conductor
diameter
Length 10 m, 15 m, 20 m, 25 m, 30 m

Caution
The pin assignment table of the E1 cable is put in one packing case with the cable.
Be sure not to discard it before installation

10.5.3 120 ohm 8xE1 Cable


The 120 ohm 8 x E1 cable is used to input/output E1 signals. One end uses DB44
connector, connected to 120 ohm E1 electrical interface board D12S. The other end
is connected to the DDF. The connector needs to be made as required. Each cable
can transmit eight E1 signals.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-35


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Structure
The structure of the 120 ohm 8xE1 cable is shown in Figure 10-27.

1. Cable connector-D type-44PIN-male 2. Tag 1, marked:"W1 (TX1–8)"


3. Tag 3, marked"W2 (RX1–8)" 4. Main tag
Figure 10-27 Structure of the 120 ohm 8 x E1 cable

Pin Assignment
The pin assignment of the 120 ohm 8xE1 cable is shown in Table 10-25.

Table 10-25 Pin assignment of the 120 ohm 8 x E1 cable


PIN of Cable W1 Remark PIN of Cable W2 Remark
DB44 DB44
Core Series NO. Core Series
NO.

15 Blue Pair Tx1 38 Blue Pair Rx1


30 White 23 White
14 Orange Pair Tx2 37 Orange Pair Rx2
29 White 22 White
13 Green Pair Tx3 36 Green Pair Rx3
28 White 21 White
12 Brown Pair Tx4 35 Brown Pair Rx4
27 White 20 White
11 Grey Pair Tx5 34 Grey Pair Rx5
26 White 19 White
10 Blue Pair Tx6 33 Blue Pair Rx6
25 Red 18 Red

10-36 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

PIN of Cable W1 Remark PIN of Cable W2 Remark


DB44 DB44
Core Series NO. Core Series
NO.

9 Orange Pair Tx7 32 Orange Pair Rx7


24 Red 17 Red
8 Green Pair Tx8 31 Green Pair Rx8
7 Red 16 Red
Shell Out braid of whole cable Shell Out braid of whole cable

Technical Parameters
Item Description

Connector X Cable connector-D type-44PIN-male


Cable model Communication cable-120 ohm-SEYPVPV-0.5
mm-24AWG-16 cores-PANTONE 430U
Number of cores 16
Inner conductor 0.5 mm
diameter
Fireproof level CM
Length 10 m, 15 m, 20 m, 30 m, 40 m

10.5.4 120 ohm 16xE1 Cable


The 120 ohm 16 x E1 cable is used to input/output E1 signals. One end uses 2 mm
HM connector, connected to the 120 ohm E1 electrical interface board L12S or
PL1B. The other end is connected to the DDF. The connector needs to be made as
required. Each cable can transmit 16 E1 signals.

Structure
The structure of the 120 ohm 16xE1 cable is shown in Figure 10-28.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-37


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

W2

X
W1
2

1. Cable connector 2. Terminal 3. Main tag


Figure 10-28 Structure of the 120 ohm 16xE1 cable

Pin Assignment
The pin assignment of the 120 ohm 8xE1 cable is shown in Table 10-26.

Table 10-26 Pin assignment of the 120 ohm 16xE1 cable


Plug X Cable W1 Remark Plug X Cable W2 Remark

Core Series Core Series


NO. NO.

a1 Blue Pair R1 a3 Blue Pair T1


a2 White a4 White
a6 Orange Pair R2 a8 Orange Pair T2
a7 White a9 White
b1 Green Pair R3 b3 Green Pair T3
b2 White b4 White
b6 Brown Pair R4 b8 Brown Pair T4
b7 White b9 White
c1 Grey Pair R5 c3 Grey Pair T5
c2 White c4 White
c6 Blue Pair R6 c8 Blue Pair T6
c7 Red c9 Red
d1 Orange Pair R7 d3 Orange Pair T7
d2 Red d4 Red
d6 Green Pair R8 d8 Green Pair T8
d7 Red d9 Red
a10 Brown Pair R9 a12 Brown Pair T9

10-38 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Plug X Cable W1 Remark Plug X Cable W2 Remark

Core Series Core Series


NO. NO.

a11 Red a13 Red


a15 Grey Pair R10 a17 Grey Pair T10
a16 Red a18 Red
b10 Blue Pair R11 b12 Blue Pair T11
b11 Black b13 Black
b15 Orange Pair R12 b17 Orange Pair T12
b16 Black b18 Black
c10 Green Pair R13 c12 Green Pair T13
c11 Black c13 Black
c15 Brown Pair R14 c17 Brown Pair T14
c16 Black c18 Black
d10 Grey Pair R15 d12 Grey Pair T15
d11 Black d13 Black
d15 Blue Pair R16 d17 Blue Pair T16
d16 Yellow d18 Yellow
a5 shield PGND a14 shield PGND

Technical Parameters
Item Description

Connector X 2 mm HM cable connector-4x18PIN—24-26AWG-press-fit


Cable model Symmetrical twisted pair-120 ohm-SEYPVPV-0.5
W1/W2 mm-24AWG-32 cores-PANTONE 430U
Number of cores 32
Inner conductor 0.5 mm
diameter
Fireproof level CM
Length 10 m, 15 m, 20 m, 25 m, 30 m

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-39


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

10.5.5 E3/T3/STM-1 Cable


The E3/T3/STM-1 cable is used to input/output E3/T3/STM-1 signal. One end uses
SMB connector, connected to the E3/T3/STM-1 interface board. The other end is
connected to the DDF, and the connector needs to be made as required.

Structure
The structure of the E3/T3/STM-1 cable is shown in Figure 10-29.

1. Coaxial connector-SMB 2. Main tag 3. Coaxial cable


Figure 10-29 Structure of the E3/T3/STM-1 cable

Pin Assignment
None

Technical Parameters
Item Description

Connector Coaxial connector-SMB-75 Ω-straight and female


Cable I Model Coaxial cable-75 ohm-3.9 mm-2.1 mm-0.34 mm-shielded
Diameter cover diameter 3.9 mm-insulation diameter 2.1
mm-conductor diameter 0.34 mm
Length 10 m, 15 m, 20 m, 30 m
Cable II Model Coaxial cable-75 ohm-4.4 mm-2.4 mm-0.4
mm-shielded-grey
Diameter cover diameter 4.4 mm-insulation diameter 2.4
mm-conductor diameter 0.4 mm
Length 15 m, 20 m, 25 m, 30 m, 40 m
Cable III Model Coaxial
cable-75ohm-6.7mm-3.8mm-0.61mm-shielded-grey
Diameter cover diameter 6.7 mm-insulation diameter 3.8
mm-conductor diameter 0.61 mm
Length 15 m, 20 m, 25 m, 30 m, 130 m

10-40 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Item Description

Cable IV Model Coaxial cable-75 ohm-5.80 mm-3.71 mm-0.643 mm-black


Diameter cover diameter 5.80 mm-insulation diameter 3.71
mm-conductor diameter 0.643 mm
Length 30 m
Fireproof level CM

10.5.6 Extended Subrack Service Connection Cable


The OptiX OSN 3500 supports extended subrack, adding/dropping up to 504 x E1
services. The extended subrack service connection cable is used to connect the
service between main subrack and extended subrack in one cabinet. One end of the
cable is connected to the EXA/EXB interface of the UXCSB board of the main
subrack and the other end to the EXA/EXB interface of the XCE board.

Structure
The structure of the extended subrack service connection cable is shown in Figure
10-30.
2 1

1 2

X1 X2

1. PIN#1 2. PIN#26
Figure 10-30 Structure of the extended subrack service connection cable

Pin Assignment
The pin assignment of the extended subrack service connection cable is shown in
Table 10-27.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-41


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

Table 10-27 Pin assignment of the extended subrack service connection cable
Pin Core and serial number

1 Core 1
14
2 Ground
15 Core 2
3
16 Ground
4 Core 3
17
5 Ground
18 Core 4
6
19 Ground
9 Core 5
21
8 Ground
23 Core 6
10
22 Ground
12 Core 7
24
11 Ground
26 Core 8
13
25 Ground
7 Core 9
20
X1/X2 enclosure Ground

10-42 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Technical Parameters
Item Description

Connector X1/X2 Cable Connector-1.27mm mini D type-26PIN


male-LVDS,28AWG or 30AWG
Cable model Communication Cable-100Ω-UL20379-30AWG-8P+1P-grey
Number of cores 8P+1P
Fireproof level CM
Length 5 m,1.9m

10.6 Clock Cable


The OptiX OSN 3500/2500/1500 clock cables are listed in Table 10-28.

Table 10-28 OptiX OSN 3500/2500/1500 clock cables


OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

75 ohm clock cable 75 ohm clock cable 75 ohm clock cable


120 ohm clock cable 120 ohm clock cable 120 ohm clock cable
1/2-channel clock transfer 1/2-channel clock 1/2-channel clock transfer
cable transfer cable cable

10.6.1 Clock Cable


The clock cable includes 75 ohm clock cable and 120 ohm clock cable, used for
inputting/outputting external clock signal.
For the 75 ohm clock cable, one end uses SMB connector, connected to the external
clock interface of the AUX board. The other end is connected to external clock
equipment and the connector needs to be made as required
For the 120 ohm clock cable, one end uses RJ-45 connector, connected to the
external clock interface of the AUX board. The other end is connected to external
clock equipment and the connector needs to be made as required. The 120 ohm
clock cable can input/output two clock signals.

Structure
The structure of the 75 ohm and 120 ohm clock cables is respectively shown in
Figure 10-31 and Figure 10-32.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-43


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1. Coaxial connector -SMB 2. Tag


Figure 10-31 Structure of the 75 ohm clock cable

1. Tag 1 (R) and Tag2 (T) 2. Communication cable 3. Main tag


4. Network port connector-RJ-45
Figure 10-32 Structure of the 120 ohm clock cable

Pin Assignment
The pin assignment of the 120 ohm clock cable is shown in Table 10-29.

Table 10-29 Pin assignment of the 120 ohm clock cable


X1 W Remark

X1.1 Blue W1
X1.2 White
X1.4 Orange W2
X1.5 White

10-44 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Technical Parameters
Item Description

75 Connector Coaxial connector-SMB-75 Ω-straight and female


ohm
clock Cable Model Coaxial cable-75 ohm-3.9 mm-2.1mm-0.34
cable mm-shielded
Diameter cover diameter 3.9 mm-insulation diameter 2.1
mm-conductor diameter 0.34 mm
Length 10 m, 15 m, 20 m, 30 m
120 Connector X1 Network interface
ohm cable-8PIN-8bit-shielded-crystal model connector
clock
cable Cable Model Twisted pair-120 ohm-SEYPVPV-0.4
mm-26AWG-2 pairs-Pantone 430U
Conductor 0.4 mm/26AWG
diameter
Length 5 m, 10 m, 20 m, 30 m, 40 m, 50 m, 70 m, 100 m

10.6.2 1/2-Channel Clock Transfer Cable


The clock transfer cable includes 1-channel and 2-channel 75 ohm/120 ohm clock
cables.

Structure
The structure of 1-channel and 2-channel 75 ohm/120 ohm clock transfer cables is
shown in Figure 10-33 and Figure 10-34 respectively.

1. Coaxial connector-SMB-75 ohm-straight/plug-female 2. Main tag


3. 75 ohm/120 ohm transfer PCB
Figure 10-33 Structure of the 1-channel 120 ohm/75 ohm clock transfer cable

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-45


OptiX OSN 3500/2500/1500
10 Cables Hardware Description Manual

1. Coaxial connector-SMB-75 2. Tag 1:"1#” 3. Tag 2:“2#" 4. Main tag


ohm-straight/plug-female
5. 75 ohm/120 ohm transfer PCB 6. Tag 3:"1#" 7. Tag 4:"2#"
Figure 10-34 Structure of the 2-channel 120 ohm/75 ohm clock transfer cable

Pin Assignment
The pin assignment of the 2-channel 120 ohm/75 ohm clock transfer cable is shown
in Table 10-30.

Table 10-30 Pin assignment of the 75 ohm/120 ohm clock transfer cable
Connector 75 ohm cable Color 120 ohm cable

X1 Core Blue W3
Shielding layer White
X2 Core Blue W4
Shielding layer White

Technical Parameters
Item Description

1-channel Connector Coaxial connector-SMB-75 Ω-straight and


female
75 Ω Model Coaxial cable-75 ohm-3.9 mm-2.1 mm-0.34
cable mm-shielded
Diameter Cover diameter 3.9 mm-insulation diameter 2.1
mm-conductor diameter 0.34 mm
120 Model Twisted pair-120 ohm-SEYPVPV-0.4
ohm mm-26AWG-2 pairs-Pantone 430U
cable
Conductor 0.4 mm/26AWG
diameter
Length 30 m

10-46 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 10 Cables

Item Description

2-channel X1/X2 connector Coaxial connector-SMB-75 Ω-straight and


female
75 Ω Model Coaxial cable-75 ohm-3.9 mm-2.1 mm-0.34
cable mm-shielded
Diameter Cover diameter 3.9 mm-insulation diameter 2.1
mm-conductor diameter 0.34 mm
120 Model Twisted pair-120 ohm-SEYPVPV-0.4
ohm mm-26AWG-2 pairs-Pantone 430U
cable
Conductor 0.4 mm/26AWG
diameter
Length 30 m

Issue 04 (2007-04-30) Huawei Technologies Proprietary 10-47