t315xw06 v5
t315xw06 v5
Rev. 0.0
(*
*)Preliminary Specifications
( )Final Specifications
Approval By PM Director
Approved By
YenTing Chiu
_________________________________ ____________________________________
Eugene CC Chen
____________________________________
Reviewed By Project Leader
Sarah Ke
____________________________________
Prepared By PM
Janna Huang
____________________________________
Contents
No
CONTENTS
RECORD OF REVISIONS
1 GENERAL DESCRIPTION
3 ELECTRICAL SPECIFICATION
4 OPTICAL SPECIFICATION
5 MECHANICAL CHARACTERISTICS
7 INTERNATIONAL STANDARD
7-1 SAFETY
7-2 EMC
8 PACKING
9 PRECAUTIONS
9-5 STORAGE
Record of Revision
Version Date Page Description
0.0 2010/09/27 First release
1. General Description
This specification applies to the 31.5 inch Color TFT-LCD Module T315XW06 V5. This LCD module has a TFT
active matrix type liquid crystal panel 1,366 x 768 pixels, and diagonal size of 31.5 inch. This module supports
1,366 x 768 mode. Each pixel is divided into Red, Green and Blue sub-pixels or dots which are arranged in vertical
stripes. Gray scale or the brightness of the sub-pixel color is determined with a 8-bit gray scale signal for each dot.
The T315XW06 V5 has been designed to apply the 8-bit 1 channel LVDS interface method. It is intended to
support displays where high brightness, wide viewing angle, high color saturation, and high color depth are very
important.
General Information
3. Electrical Specification
The T315XW06 V5 requires two power inputs. One is employed to power the LCD electronics and to drive the TFT
array and liquid crystal. The second input for BLU is to power inverter.
LCD
Note :
1. The ripple voltage should be controlled under 10% of VCC
2. Test Condition:
(1) VDD = 12.0V
(2) Fv = 60Hz
(3) FCLK = 80 Mhz (typ.), 86Mhz (max)
(4) Temperature = 25 ℃
(5) Test Pattern : White Pattern
VDD
90%
10%
GND
400 µs
V TH
V ICM
VTL
0V
6. The relative humidity must not exceed 80% non-condensing at temperatures of 40 ℃ or less. At
temperatures greater than 40 ℃, the wet bulb temperature must not exceed 39℃. When operate at low
temperatures, the brightness of LED will drop and the life time of LED will be reduced.
7. The lifetime is defined as the time which luminance of LED is 50% compared to its original value.
℃
[Operating condition: Continuous operating at Ta = 25±2 ]
C lo ck
C H x_0+ R1 R0 G0 R5 R4 R3 R2 R1 R0 G0
C H x_0-
C H x_1+ G2 G1 B1 B0 G5 G4 G3 G2 G1 B1
C H x_1-
C H x_2+
C H x_2- B3 B2 DE NA NA B5 B4 B3 B2 DE
C H x_3+
C H x_3- R7 R6 NA B7 B6 G7 G6 R7 R6 NA
Note: x = 1, 2, 3, 4…
C lo ck
CH x_0+ R3 R2 G2 R7 R6 R5 R4 R3 R2 G2
CH x_0-
CH x_1+ G4 G3 B3 B2 G7 G6 G5 G4 G3 B3
CH x_1-
CH x_2+
CH x_2- B5 B4 DE NA NA B7 B6 B5 B4 DE
CH x_3+
CH x_3- R1 R0 NA B1 B0 G1 G0 R1 R0 NA
Note: x = 1, 2, 3, 4…
Notes:
(1) Display position is specific by the rise of DE signal only.
st st
Horizontal display position is specified by the rising edge of 1 DCLK after the rise of 1 DE, is displayed on the
left edge of the screen.
(2) Vertical display position is specified by the rise of DE after a “Low” level period equivalent to eight times of
st st
horizontal period. The 1 data corresponding to one horizontal line after the rise of 1 DE is displayed at the top
line of screen.
(3) If a period of DE “High” is less than 1,366 DCLK or less than 768 lines, the rest of the screen displays black.
(4) The display position does not fit to the screen if a period of DE “High” and the effective data period do not
synchronize with each other.
Page 11 / 29
Tv M pixel
Tblk(v) Tdisp(v)
N L in e
Th
DE
RGB Line Invalid Data Line Line Line Line Line Invalid Data
N 1 2 3 4 N
Data
90% 90%
Pow er Supply For LCD
VD D (+ 12 V ) 10% 10% 10%
G ND
t1 t2 t5 t6 t7
t3 t4
Backlight on / off
control signal
( VBLO N ) GND
t8 t9
CM O S Interface Signal
G ND
Values
Parameter Unit
Min. Type. Max.
t1 0.4 --- 30 ms
t2 0.1 --- 50 ms
t3 450 --- --- ms
*1
t4 0 --- --- ms
t5 0 --- --- ms
*2
t6 --- --- --- ms
t7 500 --- --- ms
t8 10 --- 50 ms
t9 0 --- --- ms
Note:
(1) t4=0 : concern for residual pattern before BLU turn off.
(2) t6 : voltage of VDD must decay smoothly after power-off. (customer system decide this value)
Spec
Item Symbol Condition Unit Note
Min Typ Max
ON 2 - 5.5 -
5 On/Off control voltage VBLON VDDB=24V VDC
OFF 0 - 0.8 3
13 NC NC
(Note*) IF External PWM function less than 5 % dimming ratio. Judge condition as below:
(1) Backlight module must be lighted ON normally.
(2) All protection function must work normally.
(3) Uniformity and flicker could NOT be guaranteed
24V(typ.)
90% 90%
10%
Power Input for BLU
(VDDB)
T1 T2 T5
Value
Parameter Units
Min Typ Max
T1 20 - - ms
T2 500 - - ms
T3 250 - - ms
T4 0 - - ms
T5 1 - - ms
T6 - - 10 ms
4. Optical Specification
Optical characteristics are determined after the unit has been ‘ON’ and stable for approximately 45 minutes in a
dark environment at 25°C. The values specified are at an approximate distance 50cm from the LCD surface at a
viewing angle of φ and θ equal to 0°.
Fig 1 presents additional information concerning the measurement equipment and method.
SR3 or equivalent
Values
Parameter Symbol Unit Notes
Min. Typ. Max
Contrast Ratio CR 2,400 3,000 -- -- 1
2
Surface Luminance (White) LWH 280 350 -- cd/m 2
Luminance Variation δWHITE(9P) -- -- 1.33 -- 3
Response Time (G to G) Tγ -- 6.5 -- Ms 4
Color Gamut NTSC -- 72 -- % --
Red RX 0.64 -- --
RY 0.33 -- --
Green GX 0.31 -- --
Color GY 0.62 -- --
Typ.-0.03 Typ.+0.03
Coordinates Blue BX 0.15 -- --
BY 0.06 -- --
White WX 0.280 -- --
WY 0.290 -- --
x axis, right(φ=0°) θr -- 89 -- degree 5
Viewing x axis, left(φ=180°) θl -- 89 -- degree 5
Angle y axis, up(φ=90°) θu -- 89 -- degree 5
y axis, down (φ=270°) θd -- 89 -- degree 5
2. Surface luminance is luminance value at point 5 across the LCD surface 50cm from the surface with all pixels
displaying white. From more information see FIG 2. When lamp current IH = 11mA. LWH=Lon5 where Lon5 is
the luminance with all pixels displaying white at center 5 location.
3. The variation in surface luminance, δWHITE is defined (center of Screen) as:
δWHITE(9P)= Maximum(Lon1, Lon2,…,Lon9)/ Minimum(Lon1, Lon2,…Lon9)
4. Response time T γ is the average time required for display transition by switching the input signal for five
luminance ratio (0%,25%,50%,75%,100% brightness matrix) and is based on Fv=60Hz to optimize.
Measured Target
Response Time 0% 25% 50% 75% 100%
0% 0% to 25% 0% to 50% 0% to 75% 0% to 100%
25% 25% to 0% 25% to 50% 25% to 75% 25% to 100%
Start 50% 50% to 0% 50% to 25% 50% to 75% 50% to 100%
75% 75% to 0% 75% to 25% 75% to 50% 75% to 100%
100% 100% to 0% 100% to 25% 100% to 50% 100% to 75%
5. Viewing angle is the angle at which the contrast ratio is greater than 10. The angles are determined for the
horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the LCD surface. For
more information see FIG4.
FIG. 2 Luminance
H/2 1 2 3
4 5 6 H
7 8
H/6
V/6 V/2
The response time is defined as the following figure and shall be measured by switching the input signal for “any
level of grey(bright) “ and “any level of gray(dark)”.
Any level of gray (Bright) Any level of gray (Dark) Any level of gray (Bright)
0%, 25%, 50%, 75%, 100% 0%, 25%, 50%, 75%, 100%
90%
Photodetector
Output
10%
0%, 25%, 50%, 75%, 100%
Time
T γ (F) T γ (R)
5. Mechanical Characteristics
The contents provide general mechanical characteristics for the model T315XW06 V5. In addition the figures in the
next page are detailed mechanical drawing of the LCD.
Horizontal 735.4mm
Vertical 433 mm
Outline Dimension
Depth 10.8 mm
Horizontal 705.4mm
Bezel Opening
Vertical 400mm
Horizontal 697.685mm
Active Display Area
Vertical 392.256mm
Height: 38.1 cm
8 Drop test (With carton) 5 1 corner, 3 edges, 6 surfaces
(ASTM-D5276)
7. International Standard
7-1 Safety
(1) UL 60950-1, UL 60065; Standard for Safety of Information Technology Equipment Including electrical
Business Equipment.
(2) IEC 60950-1 : 2001, IEC 60065:2001 ; Standard for Safety of International Electrotechnical Commission
(3) EN 60950 : 2001+A11, EN 60065:2002+A1:2006; European Committee for Electrotechnical Standardization
(CENELEC), EUROPEAN STANDARD for Safety of Information Technology Equipment Including Electrical
Business Equipment.
7-2 EMC
(4) ANSI C63.4 “Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electrical
Equipment in the Range of 9kHz to 40GHz. “American National standards Institute(ANSI), 1992
(5) C.I.S.P.R “Limits and Methods of Measurement of Radio Interface Characteristics of Information Technology
Equipment.” International Special committee on Radio Interference.
(6) EN 55022 “Limits and Methods of Measurement of Radio Interface Characteristics of Information
Technology Equipment.” European Committee for Electrotechnical Standardization. (CENELEC), 1998
8. Packing
8-1 Definition of Label
Panel Label
*xxxxxxxxxxxx-xxxxxx*
AU Optronics
*xxxxxxxxxxxx-xxxxxx*
(2) For RoHs compatible products, AUO will add RoHS for identification.
Note: The green Mark will be present only when the green documents have been ready by AUO internal green
team. (definition of green design follows the AUO green design checklist.)
Carton Label
QTY : 5
T315XW06 V.5
97.31T15.5XX
*XXXXXX-XXXXXXXXXX*
5pcs Modules
” H ” Tape
Cushion set
Specification Packing
Item
Quantity Dimension Weight (kg) Remark
1 Packing BOX 5pcs/box 828(L)mm*283W)mm*536(H)mm 36.5
2 Pallet 1 1150(L)mm*840(W)mm*132(H)mm 13
3 Boxes per Pallet 8 boxes/Pallet
4 Panels per Pallet 40 pcs/pallet
1150(L)mm*840(W)mm*1204(H)mm 305
Pallet after
5 N/A 1150(L)mm*840(W)mm*2408(H)mm
packing 610
Double Pallet
Stretch film
Corner angle
Pallet
8. Precautions
Please pay attention to the followings when you use this TFT LCD module.
(2) You should consider the mounting structure so that uneven force (ex. twisted stress) is not applied to module.
And the case on which a module is mounted should have sufficient strength so that external force is not
transmitted directly to the module.
(3) Please attach the surface transparent protective plate to the surface in order to protect the polarizer.
Transparent protective plate should have sufficient strength in order to the resist external force.
(4) You should adopt radiation structure to satisfy the temperature specification.
(5) Acetic acid type and chlorine type materials for the cover case are not desirable because the former
generates corrosive gas of attacking the polarizer at high temperature and the latter cause circuit broken by
electro-chemical reaction.
(6) Do not touch, push or rub the exposed polarizer with glass, tweezers or anything harder than HB pencil lead.
And please do not rub with dust clothes with chemical treatment. Do not touch the surface of polarizer for
bare hand or greasy cloth. (Some cosmetics are detrimental to the polarizer.)
(7) When the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials like
chamois soaks with petroleum benzene. Normal-hexane is recommended for cleaning the adhesives used to
attach front/ rear polarizer. Do not use acetone, toluene and alcohol because they cause chemical damage
to the polarizer.
(8) Wipe off saliva or water drops as soon as possible. Their long time contact with polarizer causes
deformations and color fading.
(9) Do not open the case because inside circuits do not have sufficient strength.
9-5 Storage
When storing modules as spares for a long time, the following precautions are necessary.
(1) Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep the temperature
between 5 ℃ and 35℃ at normal humidity.
(2) The polarizer surface should not come in contact with any other object. It is recommended that they be
stored in the container in which they were shipped.