Iql Electric Linear Actuator Installation and Maintenance Manual
Iql Electric Linear Actuator Installation and Maintenance Manual
Iql Electric Linear Actuator Installation and Maintenance Manual
ELECTRIC
Index
1. Precaution before installation
2. Long term Storage
3. Operating principle
4. Environmental condition
5. Manual operation
6. Parts for mounting actuator on valve
7. Mounting actuator on valve
8. Setting limit switch
9. Wiring and connection
10. Commissioning
11. Maintenance
12. Spare Part
13. Others
3. Operating principle
IQL actuators are engineering device to providing thrust force to move valves and the force
which comes out from the drive shaft is generated by the motor with multi stage of reducing
gearing.
Actuator is mounted on valve supported by the two pillars, and pillars can be different
depending on valve types.
Drive shaft transfer the pushing force through stem nut to valve shaft, and total stroke which
valve can move are limited by adjustable two limit switches which are on each end(Up : open,
down:close)
Manual operation can be ready by pulling the auto/manual lever toward handwheel and wiring
should be done as per the wiring diagram attached inside of actuator cover.
4. Environmental condition
Ambient temperature -20 ~ +70oC
Duty cycle (IEC34-1) S2 30 min Max
S4 1200/ch 50%ED
Enclosure protection (EN60529) IP67
Space heater(Heating resistor) 5W
5. Manual operation
When mounting actuator on valve or during setting limit switches, actuator should be operated
by manual handehweel.
A. By pulling auto/manual lever toward handwheel, manual operation can be possible, and
once power comes in, auto/manual lever will be automatically resorted to auto operation.
B. Mechanical setting should be properly done.
Caution : 1) Don’t operate handwheel with extremely excessive force
2) Total mechanical stroke should be limited between upper limit and lower limit,
and if setting is done over this range, it may cause serious problem in the
performance and operation of actuator.
.
6. Parts for mounting actuator on valve 50
A
A. Base(Actuator flange) 40
30
B
B. Folding stack 20
10
C
C. Pillar D. Socket 0
D
L
E. Coupler F. Stem nut E
M
G. Valve stem F
H. Lock-nut
N G
I. Mounting plate
J. Nut K. Valve body
L. Stroke scale H
M. Upper Stroke limit I
N. Lower Stroke limit J
K
ㅅ
7. Mounting actuator on valve
IQL actuator can be easily applicable to
various type of valves.
Warning! 1. Before completing setting limit switches(Open/Close), make sure not to supply
any electric power to actuator at any case, and setting limit switches should be done by
manual.
IQL Series electric linear actuator
Installation and maintenance manual(IQL-M0100/06/12)
IQL ELECTRIC LINEAR ACTUATOR
ELECTRIC
Caution! 1. Upper stroke limit and lower stroke limit are marked on pillar to indicate
mechanical maximum stroke, and when mounting actuator valve, total stroke of valve
should be set between these two limits.
2. So, the length of valve stem should be carefully decided after checking all
dimension of pillar, valve stem and other related parts, and make sure valve stroke
should be within this range after mounting.
Actuator should be properly mounted on valve supporting by pillar.
Referring to the dimension of pillar and other parts which are related with mounting, and
following procedure should be considered when mounting actuator on valve.
1) Separating Coupler(E), machine threads in coupler(Female) properly as per the threads of valve
stem(G. male).( Pay attention not to loose the screws when separating Coupler).
2) Prepare the flange(I) on valve to assemble with lower part of pillar which threads parts of pillar
can go through, and this flange can be different depending on valve type.
3) Mounting flange(I) on valve and tighten by locking device(H).
4) Making the lower part of pillar go through flange holes, and assembly it with spring washer and
nuts(J), but make sure not to tighten it up so much.
5) Two lines are marked at upper(M) and lower(N) of Pillar indicating upper and lower stroke limit,
and valve total stroke should be in this range. So, after checking the max stroke of valve, mount
actuator properly so that max stroke of valve may not set out of this range.
6) Assemble machined Coupler(E) with valve stem, and tighten it with nut(J) from the bottom.
Don’t forget to insert spring washer.
7) Using manual handwheel, make actuator move down and assemble coupler with actuator shaft
together. And between actuator shaft and coupler, must insert indicator plate without
fail(Attention to the direction of indicator).
8) Tighten the nuts(J) onto the threads of pillar which came out from the hole of flange(I).
Make sure end of pillar must be completely inserted into the hole of flange.
Caution! 1. Before tightening nut on valve flange, double check if ends of pillar are completely
inserted into the holes of mounting flange. If not, correct the position of pillar or flange.
Basic principles
2-way type valve(Through-valve) requires Force/limit at close first, and requires limit
independent at open position.
3-way valves requires force/limit set for both ends.
Force/limit setting
By using manual handwheel, set Close limit switch as below.
Checking the indicator, make sure close setting point is not over the lower limit on Pillar.
1) Using manual handwheel, close the valve until valve cone reach at the bottom of valve.
2) Make a small mark on pillar at this point looking the sharper point of indicator.
3) Below graphs are indication between compressed length of disc spring in mm, and force.
Depending on model, make actuator move by handwheel until disc springs are compressed as
per the graph shown. For example of IQL06, if compressed length from the marked point is
1.8mm, it equals to 6KN force, and set limit switch at this point as close.
F(KN)
25
F(KN)
F(KN) 10
6.0
IQL 25
IQL 12 6.7
IQL 06 2.0
1.2
S(mm) 0 S(mm) S(mm)
0 1.8 3.4 0
IQL12 IQL25 4.3
IQL06
4) Loosening screw of cam in close limit, move cam until cam activate the limit switch, fix the
screw.
5) By using manual handwheel, try actuator move open and
close for several times, check if close setting is correct or
not.
6) Check if the length of compressed disc spring is correct or
not, and if necessary, set limit switch again.
7) After close setting, put stroke scale on pillar based on close
point.
10. Commissioning
Open cover and place the actuator in the middle of total stroke of valve by using manual handwheel.
1) Supply main power.
2) Supply open signal for 5~10 seconds, check if operating direction is correct or not. Vise versa.
If direction is reverse, exchange the signal line each other.
3) If main power is 3 phase electricity, checking operating direction must be done before normal
operation. Otherwise, actuator or valve may get fatal damage!
4) Keep supplying signal until cam activate the limit switch, and if necessary, set the cam correctly
again!.
11. Maintenance
1) If actuator is under normal condition and maintained as per described in this manual, there is no
more special instruction for the maintenance and no need to refill the grease or lubricant into
actuator.
2) Actuators need to be clean and dry condition under operation and storage.
13. Others
1) Test and inspection report are to be provided together with actuator, and so pay attention not to
loose these documentation for maintenance and repair in future if necessary.
2) For more detail information, please contact local distributor or agent, so that more technical and
detail service will be provided.