Mgate 5105-Mb-Eip Quick Installation Guide: Hardware Introduction

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Hardware Introduction Dimensions

Unit: mm (inch)
LED Indicators
MGate 5105-MB-EIP
LED Color Description
Quick Installation Guide
Ready Off Power is off or fault condition exists
First Edition, June 2013
Green Steady: Power is on and the MGate is
functioning normally
Blinking: The MGate has been located by
Overview the MGate Manager’s Location function
The MGate 5105-MB-EIP is an industrial Ethernet gateway for Red Steady: Power is on and the MGate is
Modbus RTU/ASCII/TCP and EtherNet/IP network communication. booting up
Blinking slowly: Indicates an IP conflict, or
Package Checklist DHCP or BOOTP server is not responding
properly
Before installing the MGate 5105-MB-EIP, verify that the package Flashing quickly: microSD card failed
contains the following items: Reset Button
EIP Off No I/O data is exchanged
• 1 MGate 5105-MB-EIP gateway Restore the MGate to factory default settings by using a pointed
(Scanner)
• RJ45 to DB9 cable (for console use) Green Steady: I/O data is exchanged with all object (such as a straightened paper clip) to hold the reset button
• Documentation and software CD devices down until the Ready LED stops blinking (approx. 5 seconds).
• Quick installation guide Blinking: I/O data is exchanged with at
• Warranty card least one device
(Not all configured devices can Pull-high, Pull-low, and Terminator for RS-485
Optional Accessories:
communicate with gateway)
Remove the MGate 5105-MB-EIP’s top cover and you will find DIP
• DR-45-24: 45W/2A DIN rail 24 VDC power supply with EIP Off No I/O data is exchanged switches to adjust each serial port’s pull-high resistor, pull-low
universal 85 to 264 VAC input (Adapter) resistor, and terminator.
Green I/O data is exchanged with all devices
• DR-75-24: 75W/3.2A DIN rail 24 VDC power supply with
universal 85 to 264 VAC input MB Off No communication with Modbus device SW 1 2 3
• DR-120-24: 120W/5A DIN rail 24 VDC power supply with 88 to Pull-high Pull-low Terminator
132 VAC/176 to 264 VAC input by switch Green Modbus communication progress
resistor resistor
• WK-36-01: Wall mounting kit Red Communication error ON 1 kΩ 1 kΩ 120 Ω
Please notify your sales representative if any of the above items When MGate 5105 acts as Master: OFF 150 kΩ* 150 kΩ* –*
are missing or damaged. 1. Slave device returned an error *Default
(exception)
2. Received frame error (parity error,
checksum error)
3. Timeout (slave device no
response)
When MGate 5105 acts as Slave:
1. Received invalid function code
2. Master accessed invalid register
address or coil addresses
3. Received frame error (parity error,
checksum error)

P/N: 1802051050010
–1– –2– –3–
Hardware Installation Procedure Pin Assignments Specifications
1. Connect the power adaptor. Connect the 12-48 VDC power line Modbus Serial Port (Male DB9) Power Requirements
or DIN rail power supply to the MGate 5105-MB-EIP device’s Power Input 12 to 48 VDC
terminal block. Power Consumption 455 mA @ 12 VDC, 125 mA @ 48 VDC
2. Use a Modbus serial cable to connect the MGate to a Modbus Operating Temperature Standard models: 0 to 60°C (32 to
slave device. 140°F)
3. Use an Ethernet cable to connect the MGate to the EtherNet/IP Wide temp. models: -40 to 75°C (-40
controller. to 167°F) for –T model
4. The MGate 5105-MB-EIP is designed to be attached to a Ambient Relative Humidity 5 to 95% RH
DIN rail or mounted on a wall. For DIN rail mounting, push Dimensions 36 x 105 x 140 mm
down the spring and properly attach it to the DIN rail until it (1.42 x 4.13 x 5.51 in)
“snaps” into place. For wall mounting, install the wall mount kit
Reliability
(optional) first, and then screw the device onto the wall. The
Alert Tools Built-in buzzer and RTC
following figure illustrates the two mounting options:
MTBF 513,139 hrs

Ethernet Port (RJ45)

Power Input and Relay Output Pinouts

Software Installation Information


To install MGate Manager, insert the MGate Documentation and
Software CD into your PC’s CD-ROM drive, and then run the
following setup program to begin the installation process from the
“Software” directory:
MGM_Setup_[Version]_Build_[DateTime].exe V2+ V2- V1+ V1-

The filename of the latest version may have the following format:
MGM_Setup_Verx.x.x_Build_xxxxxxxx.exe. DC DC DC DC
Shielded
Power Power N.O. Common N.C. Power Power
For detailed information about MGate Manager, refer to the MGate Ground
Input 2 Input 2 Input 1 Input 1
5105-MB-EIP User's Manual, which can be found in the “Document”
directory.
www.moxa.com/support

The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)


Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)

 2013 Moxa Inc. All rights reserved.