This document provides design data for a skylight at the Tata Memorial Centre project in Visakhapatnam, India. It includes the dimensions and geometry of the atrium space, as well as load calculations for the roof structure. The dead and live loads were calculated according to industry standards. Wind load calculations were also provided following the specifications in IS 875-2015, with a basic wind speed of 50 m/sec and design wind speed of 74.15 m/sec. External pressure coefficients for the hipped roof were listed from the code based on the roof angle and wind direction.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
94 views

Loading Data For Atrium

This document provides design data for a skylight at the Tata Memorial Centre project in Visakhapatnam, India. It includes the dimensions and geometry of the atrium space, as well as load calculations for the roof structure. The dead and live loads were calculated according to industry standards. Wind load calculations were also provided following the specifications in IS 875-2015, with a basic wind speed of 50 m/sec and design wind speed of 74.15 m/sec. External pressure coefficients for the hipped roof were listed from the code based on the roof angle and wind direction.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 8

Project : TATA MEMORIAL CENTRE

Aganampudi, Visakhapatnam

Project Consultants : CRN Architects, Chennai


Client : HINDUSTAN CONSTRUCTION COMPANY
Structural Consultants : Narnindi Consulting Engineers
Title : Design data for Sky Light -1

I ATRIUM - 1 GEOMETRICAL DESIGN DATA


Column o/o distance = 35.5 M

Clear Projection of roof on all sides from column = 0.75 M

Length of the Atrium = 37.00 M

Column o/o distance (width wise) = 25.4 M


Clear Projection of roof on all sides from column = 0.75 M

Width of the Atrium = 26.90 M

F.D.L. To F.F.L. = 0.60 M


F.F.L. Level = 82.50 M
Terrace Level = 95.90 M
Terrace Level to Beam top = 0.45 M
Terrace Level Beam to Ring beam top = 2.10 M

Eaves Height from F.D.L. = 16.55 M

Roof Slope = 6 Deg


Maximum Spacing of Purlins (East & West) = 1.700 M
Maximum Spacing of Purlins (North & South) = 1.218 M
Eaves Purlin Spacing
FOR "E" & "W" = 0.734 M
FOR "N" & "S" = 0.752 M
II DESIGN LOADS
1 DEAD LOAD :

Roofing Sheet density as per Manufacturer's data


= 1200.00 Kg/Cu.M
sheet (Tuflite Top Seam)

Sheet thickness = 12.00 mm


Self weight of roofing sheet = 14.40 Kg/Sq.M

Design weight of roofing sheet including


= 20.00 Kg/Sq.M
accessories

= 0.20 Kn/Sq.M

Dead Load on East & West side purlins = 0.340 Kn/M


Dead Load on North & South side purlins = 0.244 Kn/M
Dead Load on Eaves purlins East & West = 0.147 Kn/M
D.Load on Eaves purlins North & South = 0.150 Kn/M

Design Data Ncoen Page 1


IS:875- 2003 (Part 2) Table - 2, S.No. 1-(i) b -
2 LIVE LOAD : = 0.75 Kn/Sq.M
Access not provided except for maintenance

Live Load on East & West side purlins = 1.275 Kn/M


Live Load on North & South side purlins = 0.914 Kn/M
Live Load on Eaves purlins East & West = 0.55 Kn/M
L.Load on Eaves purlins North & South = 0.564 Kn/M

3 WIND LOAD : as per IS 875 Part-3, 2015

a Basic Wind Speed (Vb) = 50 m/sec

As per IS:875 -2015 - Basic wind speed Map of


= 180 KMPH
India

b Design Wind Speed (Vz) = Vb x K1 x K2 x K3 x K4

K1 = 1.08 As per IS:875 -2015, part 3 , Table 1, Sl.No. (iv)

As per IS:875 -2015, part 3 , Table 2, Terrain Category - 2,


K2 = 1.0562
Height 16.55m

K3 = 1.0 As per IS:875 -2015, part 3 , Clause 6.3.3.1

As per IS:875 -2015, part 3 , Clause 6.3.4, for Hospital


K4 = 1.30
Building

Design Wind Speed (Vz) = 50 x 1.08 x 1.0562 x 1.00 x 1.30


= 74.15 m/Sec

c Wind Pressure Pz = 0.6 Vz2


= 3298.51 N/Sq.m
= 3.30 Kn/Sq.m

d Design Wind Pressure Pd = Kd Ka Kc Pz

As per IS:875 -2015, part 3 , 7.2.1 Wind directionality Factor


Kd = 1.0
for the Cyclone affected regions

As per IS:875 -2015, part 3 , Table 4, Sl.No.3, Clause 7.2.2.1


Ka = 0.8
(b)

Kc = 0.9 As per IS:875 -2015, part 3 , Clause 7.3.3.13

Design Wind Pressure Pd 1.00 0.8 0.9 3.30 2.375 Kn/Sq.m

EXTERNAL PRESSURE CO-EFFICIENTS FOR ROOFS As per IS:875 -2015, part 3 , Table 6

Building Height
h/w = 0.615 1/2 £ h/w £ 3/2 Ratio & Roof Angle
6 Deg
Wind flowing from West to East

East

E G 26.9M (Width)
37m

North South
F H
Design Data Ncoen Page 2
North South

37
F H

West
5 Deg 10 Deg for 6 Deg
EF -0.9 -1.1
FOR 1 DEG -0.04 -0.94
GH -0.6 -0.6 -0.60
EG -0.9 -0.8
FOR 1 DEG 0.02 -0.88
FH -0.6 -0.6 -0.60
Hipped Slope M, N for 0 deg Incidence -0.88 Wind Ward
-0.88 Lee Ward

Hipped Slope M, N for 90 deg Incidence -0.94 Wind Ward


-0.60 Lee Ward

Wind flowing from North to South


Building Height
h/w (h/l) = 0.447 h/w £ 1/2 Ratio & Roof Angle
6 Deg
EF (Wind ward) GH (Lee Ward)
-0.96 -0.4

East

E G 26.9M

37m (W)
North South
F H

5 Deg 10 Deg for 6 Deg West


EF -0.9 -1.2
-0.3 -0.96
GH -0.4 -0.4 -0.40
EG -0.8 -0.8 -0.80
FH -0.4 -0.6
FOR 1 DEG -0.04 -0.44
Hipped Slope M, N for 0 deg Incidence -0.80 Wind Ward
-0.80 Lee Ward

Hipped Slope M, N for 90 deg Incidence -0.96 Wind Ward


-0.40 Lee Ward

Internal pressure co-efficient as per Clause 7.3.2.2 ± 0.7

Design Data Ncoen Page 3


N E

W S

NET CO-EFFICIENTS FOR ROOF Wind flowing from North to South


Perpendicular to ridge with internal pressure
Wind Ward (North) = -0.94 - 0.7 = -1.64
Lee Ward (South) = -0.6 - 0.7 = -1.3

Perpendicular to ridge with internal suction


Wind Ward (North) = -0.94 - -0.7 = -0.24
Lee Ward (South) = -0.6 - -0.7 = 0.10

Parallel to ridge with internal pressure


Wind Ward (North) = -0.88 - 0.7 = -1.58
Lee Ward (South) = -0.6 - 0.7 = -1.30

Parallel to ridge with internal suction


Wind Ward (North) = -0.88 - -0.7 = -0.18
Lee Ward (South) = -0.6 - -0.7 = 0.1

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure
East = -0.88 - -0.7 = -0.18
West = -0.88 - -0.7 = -0.18

Perpendicular to ridge with internal Suction


East = -0.88 - 0.7 = -1.58
West = -0.88 - 0.7 = -1.58

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
East = -0.94 - -0.7 = -0.24
West = -0.6 - -0.7 = 0.10

Perpendicular to ridge with internal Suction


East = -0.94 - 0.7 = -1.64
West = -0.6 - 0.7 = -1.30

NET CO-EFFICIENTS FOR ROOF Wind flowing from East to West


Perpendicular to ridge with internal pressure
wind ward (East) = -0.96 - 0.7 = -1.66
Lee Ward (West) = -0.4 - 0.7 = -1.10

Perpendicular to ridge with internal suction

Design Data Ncoen Page 4


wind ward (East) = -0.96 - -0.7 = -0.26
Lee Ward (West) = -0.4 - -0.7 = 0.30

Parallel to ridge with internal pressure


wind ward (East) = -0.8 - 0.7 = -1.50
Lee Ward (West) = -0.44 - 0.7 = -1.14

Parallel to ridge with internal suction


wind ward (East) = -0.8 - -0.7 = -0.10
Lee Ward (West) = -0.44 - -0.7 = 0.26

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.8 - -0.7 = -0.10
South = -0.8 - -0.7 = -0.10

Perpendicular to ridge with internal Suction


North = -0.8 - 0.7 = -1.50
South = -0.8 - 0.7 = -1.50

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.96 - -0.7 = -0.26
South = -0.4 - -0.7 = 0.30

Perpendicular to ridge with internal Suction


North = -0.96 - 0.7 = -1.66
South = -0.4 - 0.7 = -1.10

MAXIMUM PURLIN SPACINGS


FOR "E" & "W" = 1.700 M
FOR "N" & "S" = 1.218 M

Eaves Purlin Spacing


FOR "E" & "W" = 0.734 M
FOR "N" & "S" = 0.752 M

Net Pressure Wind flowing from North to South Resolving forces

Perpendicular with Internal pressure Pd x Net co-efficient x spacing of purlin Gy Gx


wind ward (North) = -4.74 Kn/Rmt -4.718 -0.496
Lee Ward (South) = -3.76 Kn/Rmt -3.740 -0.393
Eaves Purlin on North side = -2.93 Kn/Rmt -2.913 -0.306
Eaves Purlin on South side = -2.32 Kn/Rmt -2.309 -0.243

Perpendicular with Internal Suction


wind ward (North) = -0.69 Kn/Rmt -0.690 -0.073
Lee Ward (South) = 0.29 Kn/Rmt 0.288 0.030

Design Data Ncoen Page 5


Eaves Purlin on North side = -0.43 Kn/Rmt -0.426 -0.045
Eaves Purlin on South side = 0.18 Kn/Rmt 0.178 0.019

Parallel with Internal pressure Pd x Net co-efficient x spacing of purlin


wind ward (North) = -4.57 Kn/Rmt -4.545 -0.478
Lee Ward (South) = -3.76 Kn/Rmt -3.740 -0.393
Eaves Purlin on North side = -2.82 Kn/Rmt -2.806 -0.295
Eaves Purlin on South side = -2.32 Kn/Rmt -2.309 -0.243

Parallel with Internal Suction


wind ward (North) = -0.52 Kn/Rmt -0.518 -0.054
Lee Ward (South) = 0.29 Kn/Rmt 0.288 0.030
Eaves Purlin on North side = -0.32 Kn/Rmt -0.320 -0.034
Eaves Purlin on South side = 0.18 Kn/Rmt 0.178 0.019

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure 20% LESS
East = -0.73 Kn/Rmt -0.58 Kn/Rmt -0.578 -0.061
West = -0.73 Kn/Rmt -0.58 Kn/Rmt -0.578 -0.061
Eaves Purlin on East = -0.31 Kn/Rmt -0.25 Kn/Rmt -0.250 -0.026
Eaves Purlin on West = -0.31 Kn/Rmt -0.25 Kn/Rmt -0.250 -0.026

Perpendicular to ridge with internal Suction


East = -6.38 Kn/Rmt -5.10 Kn/Rmt -5.075 -0.533
West = -6.38 Kn/Rmt -5.10 Kn/Rmt -5.075 -0.533
Eaves Purlin on East = -2.75 Kn/Rmt -2.20 Kn/Rmt -2.191 -0.230
Eaves Purlin on West = -2.75 Kn/Rmt -2.20 Kn/Rmt -2.191 -0.230

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
East = -0.97 Kn/Rmt -0.78 Kn/Rmt -0.771 -0.081
West = 0.40 Kn/Rmt 0.323 Kn/Rmt 0.321 0.034
Eaves Purlin on East = -0.42 Kn/Rmt -0.33 Kn/Rmt -0.333 -0.035
Eaves Purlin on West = 0.17 Kn/Rmt 0.139 Kn/Rmt 0.139 0.015

Perpendicular to ridge with internal Suction


East = -6.62 Kn/Rmt -5.30 Kn/Rmt -5.268 -0.554
West = -5.25 Kn/Rmt -4.20 Kn/Rmt -4.176 -0.439
Eaves Purlin on East = -2.86 Kn/Rmt -2.29 Kn/Rmt -2.275 -0.239
Eaves Purlin on West = -2.27 Kn/Rmt -1.81 Kn/Rmt -1.803 -0.190

Net Pressure Wind flowing from East to West

Perpendicular with Internal pressure


wind ward (East) = -6.70 Kn/Rmt -6.665 -0.701
Lee Ward (West) = -4.44 Kn/Rmt -4.417 -0.464
Eaves purlin on East Side = -2.89 Kn/Rmt -2.878 -0.302
Eaves purlin on West Side = -1.92 Kn/Rmt -1.907 -0.200

Perpendicular with Internal Suction

Design Data Ncoen Page 6


wind ward (East) = -1.05 Kn/Rmt -1.044 -0.110
Lee Ward (West) = 1.21 Kn/Rmt 1.205 0.127
Eaves purlin on East Side = -0.45 Kn/Rmt -0.451 -0.047
Eaves purlin on West Side = 0.52 Kn/Rmt 0.520 0.055

Paralle with Internal pressure


wind ward (East) = -6.06 Kn/Rmt -6.023 -0.633
Lee Ward (West) = -4.60 Kn/Rmt -4.577 -0.481
Eaves purlin on East Side = -2.61 Kn/Rmt -2.600 -0.273
Eaves purlin on West Side = -1.99 Kn/Rmt -1.976 -0.208

Parallel with Internal Suction


wind ward (East) = -0.40 Kn/Rmt -0.402 -0.042
Lee Ward (West) = 1.05 Kn/Rmt 1.044 0.110
Eaves purlin on East Side = -0.17 Kn/Rmt -0.173 -0.018
Eaves purlin on West Side = 0.45 Kn/Rmt 0.451 0.047

Hipped Slope M, N for 0 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.29 Kn/Rmt -0.23 Kn/Rmt -0.230 -0.024
South = -0.29 Kn/Rmt -0.23 Kn/Rmt -0.230 -0.024
Eaves purlin on North = -0.18 Kn/Rmt -0.14 Kn/Rmt -0.142 -0.015
Eaves purlin on South South = -0.18 Kn/Rmt -0.14 Kn/Rmt -0.142 -0.015

Perpendicular to ridge with internal Suction


North = -4.34 Kn/Rmt -3.47 Kn/Rmt -3.452 -0.363
South = -4.34 Kn/Rmt -3.47 Kn/Rmt -3.452 -0.363
Eaves purlin on North = -2.68 Kn/Rmt -2.14 Kn/Rmt -2.131 -0.224
Eaves purlin on South South = -2.68 Kn/Rmt -2.14 Kn/Rmt -2.131 -0.224

Hipped Slope M, N for 90 deg Incidence


Perpendicular to ridge with internal pressure
North = -0.75 Kn/Rmt -0.60 Kn/Rmt -0.598 -0.063
South = 0.87 Kn/Rmt 0.694 Kn/Rmt 0.690 0.073
Eaves purlin on North = -0.46 Kn/Rmt -0.37 Kn/Rmt -0.369 -0.039
Eaves purlin on South South = 0.54 Kn/Rmt 0.429 Kn/Rmt 0.426 0.045

Perpendicular to ridge with internal Suction


North = -4.80 Kn/Rmt -3.84 Kn/Rmt -3.820 -0.402
South = -3.18 Kn/Rmt -2.55 Kn/Rmt -2.532 -0.266
Eaves purlin on North = -2.96 Kn/Rmt -2.37 Kn/Rmt -2.359 -0.248
Eaves purlin on South South = -1.96 Kn/Rmt -1.57 Kn/Rmt -1.563 -0.164

Deflection limits as per IS:800-2007, Table - 6

Design Data Ncoen Page 7