EI Install Manual GEN II 111418
EI Install Manual GEN II 111418
EI Install Manual GEN II 111418
877-345-4387
530-295-4900
www.eilifts.com
Inteli-Lift
GEN II
DUMBWAITER
Installation Manual
“The Easiest Dumbwaiter system on the Market”
This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter is
easiest if the hoist-way is properly prepared. Pay close attention to hoist-way drawings and the
following notes.
1. Build hoist-way to exact dimensions as instructed in the provided drawings. The dimensions indicated
in drawings are FINISHED DIMENSIONS, after sheetrock has been installed
2. Insure that hoist-way walls are built plumb and square.
3. The reinforced rail wall must be built with 2 sets of 2x12 planks as shown in the drawings – the motor
assembly, rail, cab, and load are all supported by this reinforced wall.
4. The entire inside of the hoist-way must have sheetrock installed prior to starting the installation
5. It is recommended to leave the front wall off the outside of hoist-way wall until installation is
complete – this makes installation easier and is REQUIRED for commercial door installation after the
DW is installed.
6. Installation of the motor assembly is much easier if one wall on bottom level is left unfinished – once
the rail and motor assembly are mounted, DW is installed and doors positioned this wall can be
finished.
7. A machine access door should be installed on the lower level for access to the motor assembly and the
controller – THIS DOOR MUST HAVE A LOCK AND REMAIN LOCKED AT ALL TIMES.
8. For safety during installation, the installer should install a temporary floor across the hoist-way at each
of the upper levels. This will prevent people from falling down the dumbwaiter shaft during
installation.
Mark a center line down the load bearing wall. This can
be done with a chalk line, or a straight edge.
Start the 1st rail on the wall with the bottom edge at
least 6” below the bottom floor door opening. The
center line on the wall should be visible down the center
of each hole in the rail.
Mark the location of the bottom and top holes in the rail
and drill pilot holes using a ¼” drill bit.
Insert roll pins in the slots at the top of the 1st piece of
rail. Leave ¼” of roll pins protruding from the top of
the rail (see image on top of next page).
Centerline
1strail should be mounted such that the Roll Pin
centerline on the wall lines up with the
centerline of the rail.
Floor Mount
For the quietist motor operation mount
the unit on the floor using the
centerline of the wall.
Wall Mount
Position the motor assembly against
the wall below the rail. Place 2 small
2x4 blocks under the motor to lift it
from the floor. These will be used as
temporary spacers.
Connecting to controller
6’ leads coming off the motor are standard.
Custom length wires available.
Mark the locations of mounting holes on
the motor assembly. Drill ¼” pilot holes
and secure the motor assembly to the
wall using the lag bolts provided.
Set the pulley assembly at the top of the rail. This will stay in place at the top of the rail while you
mark for pilot holes.
Drill ¼” pilot holes and secure the pulley assembly in place with the lag bolts provided.
2-Level Unit
3-Level Unit
Cable Thimble
Attach the cable thimble to the trolley
quick link. Slip three cable clamps
onto the cable. Feed the cable end
through the cable thimble and
through the three cable clamps.
IN
Station Board Installation IN Upper Final Limit must be screwed in place 3-4”
above the top limit switch minimum
Install each provided station board gang box aprox. 8-10” below the correct door level
against the rail on the right side of the rail (IMPORTANT) They are marked for the correct
floor level. Install as shown with the key hole on the cover plate in the upper right position.
Secure to the load bearing wall reinforcement. Power down before connecting
Pull the first data line (BLACK) from the controller leaving about 6” of cat 5 cable hanging
out. Store the remaining cable in the main controller. Pull the next data line to level 2. Pull
all excess cable up and fold in half at the correct location and store excess cable back down the
conduit only leaving about 6” of cat 5 cable hanging out as seen above.
Door lock and keypad cable Leave only about 6” of both cables for connection to the station
board. Store all excess cable in the door wall or door cavity. Door lock cable – BLUE Keypad
cable – WHITE. All cables are wired the same. (interchangeable).
Limit switches are used to sense the location of the dumbwaiter cab and stop it at the appropriate
level. They come with 18” of two wire attached and have two sided tape for temporary
adjustment. Connect the two wire to the terminal strip marked limit on the lower left. (does not
matter how the wires are connected it is a simple open or closed circuit). Install conduit to
switches only after the final location is located and the switch is SCREWED to the rail with
one provided self tapper. The switch is held in place with the two sided tape and one self tapper
screw through the left hole and aligned with the screw groove on the rail. The ROLLER
WHEEL should be 4-3/4” from the wall to the tip of the wheel.
Level one safeties on the station board. Safe 1 is by default “Car Gate” if the unit has a travel
cable you will attach two wire to safe 1 and rout it to the travel cable junction box, then connect
the travel cable to the car and the gate switch. Safe 2 is by default “Access Door” route two wire
to the machine room door access switch and connect. These safeties can be moved to other
locations See the “Set up menu” section.
© 2005 - Current Elevation Innovation, Inc.
Installation Manual
10
Power In / Out
Connect the incoming power to the fuse kit and
grounding lug. Connect the power out to the color
coded and labeled terminal strip.
Programming
The main board has four programming buttons S1,
S2, S3 and S4 seen below in the center of the board
around the LCD screen. See the next page for the
“Set up menus” programming and functionality.
Pre-Programmed
All systems are pre-programmed at the factory for
your field conditions. However changes can be made
if needed. All safeties not being used will be jumped
out at the factory. All safeties to be used will be left USE EXTREME CAUTION “Safe Override”
open.
Main Controller set up menu: Press S1, then S2 to enter the menu selection. The first screen allows
you to reset a “Safe Hold” error (see page 14) or press S3 to scroll through the set up menu’s to reach
the desired menu.
Safety Error: View the “Safe Hold” error on the screen in the master controller and inspect the
dumbwaiter to solve the problem (see the error description page 14). Use “Manual Mode” if the car
must be moved to solve the issue.
Safe Hold Error Reset: Once the safety is resolved you should use manual mode to position the car on
a limit switch (level 1 is preferred but not needed). Then you must reset the safety. Scroll thru the
menu items until “Reset Safety” appears (this is the first screen when entering the set up menus) then
use S2, S2 and finally S2 to “Confirm” then S1 to exit set up mode. If your safety issue was resolved
the unit will go into “Ready Run – Now at 1”. If it was not resolved the screen will still show the “Safe
Hold Error”.
Menu #1 Manual Mode Operation: Allows you to move the dumbwaiter up and down from the main
board S3 DOWN, S4 UP - or from any active keypad “arrow up” / “arrow down”. -- USE EXTREME
CAUTION IN MANUAL MODE -- NEW INSTALLATION – Power up / press S1,S2,S3,S2,S2,S2
Manual Mode Operation:“SAFETY OVERRIDE”: To operate in manual mode with safeties open --
USE EXTREME CAUTION -- slide the “safe ovrd” switch to the right. (Next to the Cat 5 out plug) the
light will flash. The controller needs to be put in “Manual Mode” to operate in this mode. Enter the set
up mode: Press S1, then S2 then S3 to reach the correct menu screen. The “safe ovrd” switch must be
in the left position to operate in automatic mode. No automatic mode with the safe ovrd button on.
Manual operation can also run off a call / send board if a station board is plugged in to controller – use
as a temporary run button.
Menu #2 Set Address: (Set at the factory) used to set floor levels. To set, press S2 and on each key pad
select the proper level (up down arrows) and press the call / send button to set press S2 to save changes
then S1 to exit set up mode.
Menu #3 Number of Stops: Factory set. Programmable - Programs master board for correct number
of stops
Menu #5 Open door Lock: (EMI Interlock only): Press S2 then S3 or S4 to select the door level to
open, then S2 to unlock. Door will remain open until this screen is exited then S1 to exit set up mode..
GAL and CJ Anderson locks require emergency release key.
Menu #6 Drive Deceleration Time: Factory set at 0.8 seconds. (Do not adjust)
© 2005 - Current Elevation Innovation, Inc.
Installation Manual
12
Menu #8 Dumbwaiter / Elevator: Factory set to “Dumbwaiter” (Do not adjust) selects between
dumbwaiter controls and elevator controls.
Menu #9 Exercise Time: -- USE EXTREME CAUTION -- For automatically running the machine for
an endurance test. Factory set to 30= 30 seconds (Adjustable) between trips when used with Menu #8
Exercise Cycles.
Menu #10 Exercise Cycles: -- USE EXTREME CAUTION -- Setting this to any number of trips other
than 0 by selecting S2 and changing using S3 or S4 to make changes and saving changes with S2 and
(exiting with S1 will IMMEDIATELY start the machine into exercise mode traveling between level
1 and level 2 with 30 seconds between trips Unless time is changed). The screen will count down the
desired number of runs. -- USE EXTREME CAUTION -- This is good for fully loaded endurance test.
Or just call / send the unit with the key pad manually. Use any controller button to stop the unit
S1,S2,S3,S4
Menu #11 Maintenance Days: Set the number of days for service. Press S4 to view days remaining.
Menu #12 Shut Down Count: Count is in days if set the machine will shut down and require a
password to be reset. May help collect final payment from your customer. “Call for password”.
Menu #13 Access Location: Access door switch (Default Bottom station board “Safe #2”)
Programmable to bottom station board safe #1 or safe #2, (OVERHEAD MOTOR) top station board #1
or master board then S1 to exit set up mode.
Menu #14 Gate Location: Car gate switch (Default 250 lb, 125 lb units - bottom station board #1) 500
lb default location - master board, along with slack cable and car light also on master. (For the traveling
cable).
Menu #15 Lower Final Limit Switch: (Default master) only used on 500 lb units. This is
programmable to Bottom safe #1 or safe #2.
Menu #16 Upper final limit switch: (Default top station board #2) Programmable to top station board
safe #1 or safe #2 or master, (shown as safe #1 on the “traveling” section on the master board).
Menu #17 Slack Cable: Slack cable switch (Manually Reset) (Default 250 lb, 125 lb units - top station
board #1) 500 lb default location - master board as the slack cable is on the travel cable. Programmable
to top station board safe #1 or safe #2, bottom station board safe #1 or safe #2 or master board.
Menu #19 Homing Floor: Programmable - 1-6. (Default is “Disabled”) S2 change, S3 or S4 make
change, S2 save S1 exit and initiate -- USE EXTREME CAUTION -- when exiting the set up menu the
machine will automatically go into “Homing” and automatically proceed to the desired floor, in the
desired time after all safeties are met like closing hoist-way door.
Menu #20 Automatic Cancel Timer: (Default 15 seconds) If a floor was selected and the call/send
was not depressed it is cancelled in desired time. (Not recommended to change).
Menu #21 Non Interrupt Timer: (Default 10 seconds) When the car arrives at a floor it will remain
there un-interrupted for the desired time, 10 - 30 seconds before acting on another call.
Menu #22 Key Light Timer: (Default “Always On”) Keypad LED light shut off timer. This is
programmable from 0-120 seconds. S2 change, S3 or S4 make change, S2 save S1 exit and initiate
Menu #23 Solenoid Timer: Factory set and recommended to use default setting (Default is 10 seconds)
EMI Interlock only! Solenoid remains energized for opening door when it arrives. This is
programmable from 1- 360 seconds. (Not recommended to change) Machine will not act on another call
until time is up. Push call / send button to open door.
Menu #25 Chime Timer: Default .5 seconds. If set to 0 there will be no chime on arrival.
“Top Station Board” safe #1= Slack cable switch - safe #2 Upper final limit switch
Access door, car gate, slack cable and final limits are programmable to top station board safe #1 or
safe #2, bottom station board safe #1 or safe #2 or master board.
Ready Run – Unit is automatic mode and all safeties are met. (Run Counter is at the right – “63”)
Ready Run – Now at 0 (this is the first screen you will see) Means the unit is not on a switch - use
manual mode to position the car on limit switch 1 and return to automatic mode.
Hoist-way door, Access Door and Car Gate Errors are reset when the open door or car gate is
closed.
Safe Hold Errors: Upper and lower final limit, slack cable, VFD drive and missed limit switch errors
must be reset manually by a technician. First you must locate and solve the error (Safe Override
switch will need to be used if manual mode is required to move the car to resolve the safety).
Safe Hold Error Reset: Once the safety is resolved you should use manual mode to position the car
on a limit switch (level 1 is preferred but not needed). Then you must reset the safety. Scroll thru the
menu items until “Reset Safety” appears (this is the first screen when entering the set up menus) then
use S2, S2 and finally S2 to “Confirm”. If your safety issue was resolved the unit will go into “Ready
Run – Now at 1”. If it was not resolved the screen will still show the “Safe hole Error”.
ALL SAFETY SWITCHES – Slack cable, final upper and machine room door are N/C normally
closed.
Commercial
Most Commercial doors have pre-installed
call / send stations.
Keypad Connection
Use the supplied Cat 5 cable (white) to
connect the keypad to the station board.
The dumbwaiter is now ready for Automatic Operation. Close the doors at every level.
View the controller display to determine if all safeties are in place. If the display shows “Ready Run
Now at 1” then the safeties are set and you can start operating the dumbwaiter.
If there are any errors, then you must troubleshoot and resolve any open safety errors.
Normal Operation
- All keypads showing current location
- Controller display reads “Ready Run”
- Press the call button or up down arrows to select a floor then the call / send button to initiate
- Dumbwaiter cab moves to level ‘x’ and stops
- Keypad alternates between direction of travel and the last floor it has passed
- Keypad light for level ‘x’ blinks while interlock is unlocked
- Door interlock stayed unlocked for 10 seconds
- Once door is closed again, the cab can be called to another level
- If cab is already at level ‘x’, pressing the level ‘x’ call / send button unlocks the interlock (EMI only)
- Calls to other floors are recognized when dumbwaiter is moving and will travel to that floor after the
door is locked. Calls to other floors are recognized when door is unlocked and will travel to that floor
after door is locked
Troubleshooting Notes
Manual Mode Operation “SAFETY OVERRIDE”: To operate in manual mode with safeties open -- USE
EXTREME CAUTION -- slide the “safe ovrd” switch to the right. (Next to the Cat 5 out plug) the light
will flash. The controller needs to be put in “Manual Mode” to operate in this mode. Enter the set up
mode: Press S1, then S2 then S3 to reach the correct menu screen. The “safe ovrd” switch must be in the
left position to operate in automatic mode. No automatic mode with the safe ovrd button on.
APPENDIX A
Installation of Stabilizer / Safety Stop Brackets
Bottom Stabilizer Roller: Attach if provided
the opposite guide rail roller bracket with the
provided hardware. Let the cab hang naturally
when tightening the bolts. Run the unit in
manual mode to ensure proper alignment.
This will provide a very stable cab for loading
and unloading.
The opposite guide rail is a 2” x 1” x 1/8”
aluminum angle with mounting hardware.
Rail on the Left 3 stops or more: requires
that the cat 5’s for door lock and keypad are run
through conduit around the hoist-way and right
through the opposite guide rail angle. Drill a
¾” hole for the ½” conduit (a step drill bit may
be the best option) as close to wall as possible.
APPENDIX B
Installation of Gate Switch and Travel Cable
Cab
Cable Fastened
at halfway point
Left side of rail
Cab
Travel
Motor Cable Motor
APPENDIX B-1
Installation of Gate Switch and Travel Cable
Travel Cable
Tie the cable to the underside of the cab with the
provide strain relief for connection to the switch,
this could be a cable strain relief or pre-installed
gang box on the car.
APPENDIX B
Installation of Gate Switch and Travel Cable
APPENDIX C
Overhead motor and sheave