Relay/Meter Class Current Transformer 780

Current transformers are used for relaying and metering applications in power systems. The document provides specifications for a Model 780 relay/meter class current transformer, including frequency range, insulation class, secondary terminal details, weight, and compliance with ANSI/IEEE standards. It also includes application and ordering data like current ratios, continuous thermal ratings, and secondary winding resistances at different temperatures. Dimensions and an excitation curve are shown.

Uploaded by

alejandrozabala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views2 pages

Relay/Meter Class Current Transformer 780

Current transformers are used for relaying and metering applications in power systems. The document provides specifications for a Model 780 relay/meter class current transformer, including frequency range, insulation class, secondary terminal details, weight, and compliance with ANSI/IEEE standards. It also includes application and ordering data like current ratios, continuous thermal ratings, and secondary winding resistances at different temperatures. Dimensions and an excitation curve are shown.

Uploaded by

alejandrozabala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CURRENT TRANSFORMERS

CURRENT TRANSFORMERS

RELAY/METER CLASS CURRENT TRANSFORMER MODEL 780

FEATURES 600V CLASS


• Relaying and Metering Applications
• High Relay Class Models
• UL Recognized
• Window I.D. - 6.50"
E238872 245941
SPECIFICATIONS
Frequency........................................................................ 50-400Hz
Insulation class...................................... 0.6kV, 10kV BIL Full Wave
Secondary Terminals.......................... Brass Studs No. 18-32 UNC
with one flatwasher, lockwasher, and one nut each.
Weight..........................................................Approximately 30 Lbs.
Manufactured to meet the requirements of ANSI/IEEE C57.13

APPLICATION AND ORDERING DATA


CONTINUOUS THERMAL SECONDARY
ANSI METERING CLASS AT 60Hz
CATALOG CURRENT RELAY RATING FACTOR WINDING
NUMBER RATIO CLASS RESISTANCE
B0.1 B0.2 B0.5 B0.9 B1.8 @30°C @55°C
OHMS @75°C
780-500 50:5 - 4.8 -- -- -- -- 2.0 1.5 0.020
780-101 100:5 C10 2.4 2.4 4.8 -- -- 2.0 1.5 0.030
780-151 150:5 C20 1.2 1.2 2.4 4.8 -- 2.0 1.5 0.043
780-201 200:5 C20 0.6 0.6 1.2 2.4 4.8 2.0 1.5 0.055
780-251 250:5 C20 0.6 0.6 1.2 1.2 2.4 2.0 1.5 0.067
780-301 300:5 C20 0.3 0.6 0.6 1.2 2.4 2.0 1.5 0.079
780-401 400:5 C50 0.3 0.3 0.6 0.6 1.2 2.0 1.5 0.102
780-501 500:5 C50 0.15 0.15 0.3 0.6 0.6 2.0 1.5 0.126
780-601 600:5 C100 0.15 0.15 0.3 0.3 0.6 2.0 1.5 0.150
780-801 800:5 C100 0.15 0.3 0.3 0.3 0.6 2.0 1.5 0.234
780-102 1000:5 C100 0.15 0.15 0.15 0.3 0.3 2.0 1.5 0.291
780-122 1200:5 C200 0.15 0.15 0.15 0.3 0.3 2.0 1.5 0.348
780-152 1500:5 C200 0.15 0.15 0.15 0.15 0.15 1.5 1.33 0.433
780-162 1600:5 C200 0.15 0.15 0.15 0.15 0.15 1.5 1.33 0.461
780-202 2000:5 C200 0.15 0.15 0.15 0.15 0.15 2.0 1.5 0.491
780-252 2500:5 C200 0.15 0.15 0.15 0.3 0.3 1.5 1.33 0.615
780-302 3000:5 C200 0.15 0.15 0.15 0.15 0.3 1.5 1.33 0.738
780-352 3500:5 C200 0.15 0.15 0.15 0.15 0.15 1.5 1.33 0.721
780-402 4000:5 C200 0.15 0.15 0.15 0.15 0.15 1.0 -- 1.035
780-502 5000:5 C200 0.15 0.15 0.15 0.15 0.15 1.0 -- 2.040
780-602 6000:5 C200 0.15 0.15 0.15 0.15 0.15 0.8 -- 2.463

DIMENSIONS
1.38
(3) 0.56 DIA. 1.00
Mounting Holes
0.75 X1 X2

X3 X4

X5

9.88

8.38 6.50 DIA. H1

4.94

8.38 0.75
9.88 3.38
All Dimensions In Inches

WWW.FLEX-CORE.COM
PHONE (614) 889-6152
Div. Morlan & Associates, Inc. [email protected]
TECH. ASSISTANCE (614) 876-8308
4970 Scioto Darby Rd. Hilliard, Ohio 43026 FAX # (614) 876-8538

Revision: 06/22/18, 01:42:56 PM 46


CURRENT TRANSFORMERS
CURRENT TRANSFORMERS

RELAY/METER CLASS CURRENT TRANSFORMER MODEL 780

EXCITATION CURVE
1000

4000:5
3500:5
3200:5

100
0.001 0.01 0.1 1 10

1000

3000:5
2500:5
2000:5

100
0.001 0.01 0.1 1 10

1000

1600:5
1500:5
1200:5
1000:5
800:5
750:5
100 600:5
500:5
400:5
300:5
250:5
200:5
150:5

100:5
75:5
10
50:5

0.1
0.001 0.01 0.1 1 10

WWW.FLEX-CORE.COM
PHONE (614) 889-6152
Div. Morlan & Associates, Inc. [email protected]
TECH. ASSISTANCE (614) 876-8308
4970 Scioto Darby Rd. Hilliard, Ohio 43026 FAX # (614) 876-8538