Rfe-Hf: Flame-Retardant Halogen-Free Instru-Mentation and Communication Cable

This document summarizes the specifications of a halogen-free instrumentation and communication cable for fixed installation in ships. The cable consists of stranded copper conductors, cross-linked polyethylene insulation, a filler tape bedding, a copper wire braid screen, and a grey polyolefin plastic sheath. It meets various IEC flame retardant and smoke emission standards. Electrical properties including loop resistance, capacitance, and inductance are provided. Conductor sizes and dimensions range from 1x2x0.5mm2 to 37x2x0.5mm2.

Uploaded by

Daniel Garcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views1 page

Rfe-Hf: Flame-Retardant Halogen-Free Instru-Mentation and Communication Cable

This document summarizes the specifications of a halogen-free instrumentation and communication cable for fixed installation in ships. The cable consists of stranded copper conductors, cross-linked polyethylene insulation, a filler tape bedding, a copper wire braid screen, and a grey polyolefin plastic sheath. It meets various IEC flame retardant and smoke emission standards. Electrical properties including loop resistance, capacitance, and inductance are provided. Conductor sizes and dimensions range from 1x2x0.5mm2 to 37x2x0.5mm2.

Uploaded by

Daniel Garcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Flame-retardant halogen-free instru-

RFE-HF
Halogen-free
mentation and communication cable
instrumentation and
communication cable CONSTRUCTION:
Twisted pair cable
STANDARDS:
IEC 60092-375, ➊
60V +85°C construction
1. Conductor
Application: - stranded copper conductor IEC 60228,
For fixed installation in all areas class 2 ➋
and on open deck in ships 2. Insulation
- XLPE plastic ➌
Important data:
Rated voltage 60V 3. Bedding
Maximum conductor - filler tape
temperature +85°C ➍
Flame-retardant IEC 60332-1 & 4. Screen
IEC 60332-3A - drain wire (in all sizes)
Halogen-free IEC 60754 series - copper wire braid coverage > 94% IEC 60092-350
Smoke emission IEC 61034 series 5. Sheath ➎
Electrical data: - grey polyolefine plastic, SHF1 IEC 60092-359
Loop resistance
of pair / +20°C: 80ohm/km
Pair capacitance / 800Hz: 90nF/km
Loop inductance: 0,6mH/km Number of conductors & Nominal outer Tolerance Approximate
Insulation resist- cross-section n x mm2 diameter mm mm weight kg/km
ance / +20°C: ≥1500Mohm*km 1x2x0,5 7,5 ±1,0 80
Recommended minimum bending 1x4x0,5 8,5 ±1,0 100
radius: 2x2x0,5 10,0 ±1,0 120
During installation 9xD
4x2x0,5 11,5 ±1,0 170
Fixed final installation 6xD
D is overall diameter of cable 8x2x0,5 14,5 ±1,0 265
12x2x0,5 17,5 ±1,0 400
Minimum installation temperature:
- 15°C 24x2x0,5 23,0 ±1,5 685
37x2x0,5 29,0 ±1,5 945
Identification:
Lot number, cable type, cable size,
voltage, temperature, standards,
production month, manufacturer's
name and meter marking printed on
the sheath
Core identification:
Each pair white - blue.
Cores numbered 1, 2, 3, 4, 5....
The four core cable is built up as
a star quad with the following
identification
1 core white
2 core blue
3 core white
4 core blue
Approvals:
ABS, BV, DNV, GL, LRS, Class NK,
RINA, RMRS