PWD Civil Work
PWD Civil Work
PWD Civil Work
1.1 Erection and maintenance of site office and removal the same after completion of work
in accordance with the conditions of contract.
In addition to the office required for his own use, the Contractor shall provide and maintain
furnished field office for the use of the Engineer and his staff. The field office is to have a
concrete floor, adequate foundation, brick walls, false ceiling of hard board with seasoned
Garjan wood frame and painted, and all windows are to be glazed and provided with steel
grill. Outside and inside wall surface are to be painted on plaster acceptable to the Engineer.
The field office shall be maintained in a secure and watertight condition by the Contractor
until the completion of the contract and shall be provided with electricity, running water and
sewerage. All doors shall be fitted with approved locks and windows shall be provided with
screen/blinds. Before construction the Contractor shall submit plans and drawings showing
proposed details and location for the field office, including foundations, access roads,
shades, layout of electrical and water supply and hard standings thereto for the approval of
the engineer. The Engineer may require revision of the plans prior to giving approval for
construction. The Contractor shall also submit details proposed furniture, fittings and other
items of equipment and plant to the engineer for approval. These items shall be of the
standard quality suitable for site. The office, complete with furnishings, fittings, access roads
and hard standings shall be ready for occupation by the Engineer within 28 days of the date
when the Contractor first occupies the site. The Contractor will provide day and night
guards and a tea boy for the field office. At the end of the project all materials, equipment
and plant, furniture, fittings recovered from dismantling the office and removing access road
will be the property of the Contractor. No interim payment shall be certified unless
1.1.1 Engineer’s site office of minimum 15 sqm plinth area with providing furniture, first aid-box, L.S. Tk. 144,894.00
safety helmet, level / theodolite, consumables, stationeries etc.
1.1.2 Engineer’s site office of minimum 38 sqm plinth area with providing security fencing, 5 Kva L.S. Tk. 440,718.00
stand-bye generator, furniture, first aid-box, safety helmet, level / theodolite, consumables,
stationeries etc.
1.1.3 Engineer’s site office of minimum 38 sqm plinth area with providing security fencing, 5 Kva L.S. Tk. 561,463.00
stand-bye generator, IBM compatible PC with monitor, uninterruptible power supply (UPS),
Laserjet printer (minimum 25 ppm), furniture, first aid-box, safety helmet,
level/theodolite/EDM, consumables, stationeries etc.
1.1.4 Engineer’s site office of minimum 38 sqm plinth area with providing security fencing, 5 Kva L.S. Tk. 602,999.00
stand-bye generator, IBM compatible PC with monitor, uninterruptible power supply (UPS),
Laserjet printer (minimum 25 ppm), photocopier, 6 cft. Freeze, furniture, first aid-box,
safety helmet, level/theodolite/EDM, consumables, stationeries etc.
1.1.5 Engineer’s site office of minimum 10 sqm plinth area with providing furniture, first aid-box, L.S. Tk. 27,168.00
safety helmet, consumables, stationeries etc for low value simple work of short duration (not
more than six months).
1.1.6 Providing and maintenance one project profile signboards of the size not exceeding 1 m x sqm. Tk. 2,670.00
2 m, to be placed at a suitable place of the site including submission of proposals for the
materials of the signboards and text layout to the Engineer for approval which will be
positioned as directed by the Engineer and removing the same on completion of the Works
or as instructed by the Engineer.
51
1.8 Supplying, fitting, fixing, operating and maintenance of the costruction supervision lift
(1000Kg capacity) for supervision of building construction work during the entire
construction period including all necessary components like, steel frame, car, guide rails.
push button, driving motor, gear box, car door, travelling cable, RCC base for steel frame,
necessary connections with the building, electric supply & electricity bill and dismantling
the same after completion of the building construction etc. all complete complying all
safety factors and accepted by the Engineer-in-charge. (The construction supervision lift
shall be the contractor property after completion of work). Number of month shall be
calculated as 1/2 (half) of the project period for new construction and full project period for
vertical extension work. The contractor must submit detail structural drawing of supporting
frame with foundation and lift specification prior to supply on site.
1.8.1 6th to 10th floor, hoisting speed 40 m/min per Tk. 28,287.00
month
1.8.2 11th to 15th floor, hoisting speed 40 m/min per Tk. 37,661.00
month
1.8.3 16th to 20th floor, hoisting speed 50 m/min per Tk. 44,911.00
month
1.8.4 21th to 25th floor, hoisting speed 60 m/min per Tk. 49,426.00
month
1.8.5 26th to 30th floor, hoisting speed 60 m/min per Tk. 55,589.00
month
2.1 Earth work in excavation in all kinds of soil for foundation trenches including. layout,
providing center lines, local bench-mark pillars, leveling, ramming and preparing the base,
fixing bamboo spikes and marking layout with chalk powder, providing necessary tools and
plants, protecting and maintaining the trench dry etc., stacking, cleaning the excavated earth
at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the
Engineer, subject to submit method statement of carrying out excavation work to the
Engineer for approval. However, Engineer’s approval shall not relieve the contractor of his
responsibilities and obligations under the contract.
2.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer. sqm. Tk. 15.00
[Plinth area of the structure shall be considered for measurement]
2.1.2 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m cum Tk. 88.00
lead: in soft clayey soil / loose sand / silt
2.1.3 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead: cum Tk. 126.00
in medium stiff clayey soil.
2.1.4 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m cum Tk. 189.00
lead: in very stiff (hard) clayey soil/ rubbish etc.
2.1.5 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m cum Tk. 217.00
lead: in very soft / saturated / organic clayey soil / soil of semi-liquid state.
2.1.6 Extra rate for each additional 0.5 meter depth exceeding 1.5 meter. cum Tk. 20.00
2.1.7 Extra rate for each 1 m additional lead beyond 10 m. cum Tk. 3.00
53
2.3 Supplying of straight and strong borrak bamboo posts of having minimum 75 mm rm. Tk. 80.00
diameter althrough and driving the same vertically in the ground up to required depth by any
means shaping the top of the post, all complete and accepted by the Engineer-in- charge..
2.4 Supplying wooden ballah having an average diameter not less than 150 mm (without barks) rm. Tk. 592.00
at one third distance from larger end with a minimum end diameter of 100 mm for retaining
purpose and driving to a depth as per design and drawing by any method including all
arrangement for staging, hoisting, carrying etc. complete and accepted by the Engineer-in-
charge..
2.5 Palisading work by supplying bitumen drum sheet walling tied with 20 BWG G.I. wire sqm. Tk. 520.00
fixing the same with already driven borrak bamboo posts with half split borrak bamboo
runners @ 450mm c/c horizontally with iron nails, G.I wire etc. all complete and accepted
by the Engineer-in- charge.. (Rate is excluding the cost of bamboo post).
2.6 Supplying and fitting-fixing horizontal bracing in Palisading with ½ split wooden ballah rm. Tk. 180.00
having an average diameter not less than 150 mm with a minimum end diameter of 100 mm
@ 450 mm including supply of iron nails, gazals etc. complete approved and accepted by
the Engineer-in- charge..
2.7.1 Shore protection work during excavation in foundation trenches up to 1.5 m depth, to sqm. Tk. 609.00
protect loss due to damage of property by Palisading accepted by the Engineer-in-
charge..[the rate is including cost of vertical post]
2.7.2 Shore protection work during excavation in foundation trenches to protect loss due to sqm. Tk. 877.00
damage of property by Palisading beyond 1.5 m depth accepted by theEngineer-in-
charge.. [the rate is including cost of vertical post]
2.8 Supply and laying 2 mm thick Geo-textile of approved quality and origin/manufacturer as sqm. Tk. 143.00
per manufacturer’s instructions approved and accepted by the Engineer.Before commencing
laying of Geo-textile, the Contractor must submit the method statement for carrying out this
work including sample with evidence of origin and compliance certificate from independent
testing laboratory for approval.
2.9 Removing sludge or semi-liquid clay/substances etc not suitable for pumping out or cum Tk. 879.00
carrying by head load from the bottom of any marshy land, lake, ditch, pond by mixing fine
local sand of F.M. 0.8 or less to a proportion such that it can be carried to an intermediate
point of disposal and cutting the same including stacking and spreading properly on a
suitable place to dry in the sun for a certain days and dispose the dried sludge or clay to a
safe distance etc. complete and accepted by the Engineer subject to submit method
statement to the Engineer for carrying out the works including ultimate disposal of the
sludge under this item for approval. However Engineer’s approval shall not relieve the
2.10.1 Sand filling in foundation trenches and plinth with sand having F.M. 0.5 to 0.8 in 150mm cum Tk. 635.00
layers including leveling, watering and compaction to achieve minimum dry density of 95%
with optimum moisture content (Modified proctor test) by ramming each layer up to
finished level as per design supplied by the design office only etc. all complete and accepted
by theEngineer-in- charge..
2.10.2 Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 1.2 in cum Tk. 913.00
150mm in layers including leveling, watering and compaction to achieve minimum dry
density of 95% with optimum moisture content (Modified proctor test) by ramming each
layer up to finished level as per design supplied by the design office only etc. all complete
and accepted by the Engineer-in- charge..
2.10.3 Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 2.2 in cum Tk. 1,760.00
150mm layers including leveling, watering and compaction to achieve minimum dry density
of 90% with optimum moisture content (Modified proctor test) by ramming each layer up to
finished level as per design supplied by the design office only etc. all complete and accepted
by the Engineer-in- charge..
54
2.14 Clearing and disposing of excavated earth from the construction site by truck or any cum Tk. 539.00
other means to a place within 30 km radius of the city or town area including loading,
unloading at both ends, leveling and dressing the carried earth etc. complete accepted by
theEngineer-in- charge..
2.15 Earth filling in foundation trenches and plinth in 150 mm layers with carted earth
carried by truck or any other means loading and unloading at both ends including leveling,
watering and compacting to achive minimum dry density of 90% with optimum moisture
content (modified proctor test) including local carriage each layer up to finished level
including cost of water and test (carried from beyond 300 m) etc. all complete and accepted
by the Engineer.
2.15.1 For Dhaka Metropolitan Area cum Tk. 622.00
2.15.2 For Chittagong / Sylhet Metropolitan Area and Narayanganj Area cum Tk. 497.00
2.15.3 For Rajshahi / Barishal / Khulna metropolitan area cum Tk. 432.00
2.15.4 For other than Dhaka, Ctg., Sylhet, Rajshahi, Barishal, Khulna metropolitan area and N'ganj cum Tk. 393.00
district
2.16 Site Development/Improvement by carted/dredged earth or sand (free from any
organic, foreign, environmental hazard substances) carried by head or truck or any other
meansl in/c cost of cutting/dredging of earth/sand, carrying, placing the earth/sand in the
designated area, maintaining slopes, breaking lumps, levelling and dressing in layers up to
finished level etc. all complete as per direction and accepted by the engineer in charge.
2.18.2 For each additional lift of 0.3 m beyond 1.5 m and up to 3 m cum Tk. 7.00
2.18.3 For each additional lift of 0.3 m beyond 3 m and up to 4.5 m cum Tk. 10.00
2.18.4 For each additional lift of 0.3 m beyond 4.5 m and up to 6 m cum Tk. 14.00
2.18.5 Extra each additional lead of 0.3 m or part thereof beyond initial lead 30 meter cum Tk. 27.00
2.19.1 Bailing out water by 1 cusec diesel operated pump including hire charge of pump, fuel, per hour Tk. 538.00
operator, spares and maintenance etc. all complete and accepted by by the Engineer-
incharge.
2.19.2 Bailing out water by 1 cusec electricity operated pump including hire charge of pump, fuel, per hour Tk. 433.00
operator, spares and maintenance etc. all complete and accepted by the Engineer-incharge.
3.1 One layer of brick flat soling in foundation or in floor with first class or picked sqm. Tk. 420.00
jhama bricks including preparation of bed and filling the interstices with local sand,
leveling etc. complete and accepted by the Engineer -in-
3.2 One layer of Herring bone bond (HBB) brick soling in foundation or in floor with first sqm. Tk. 662.00
class or picked jhama bricks including preparation of bed and filling the interstices with
local sand, leveling including the supply of water, electricity and other charges and costs of
tools and plants etc. all complete and accepted by the Engineer -in-
3.3 Brick on end edging including preparation of bed and filling the interstices with local sand, rm. Tk. 104.00
leveling, maintaining alignment grid etc. all complete and accepted by the Engineer -in-
charge.
3.4 Mass concrete (1:3:6) in foundation or floor with cement, sand (F.M. 1.2) and picked
jhama chips including breaking chips, screening, mixing, laying, compacting to levels and
curing for at least 7 days including the supply of water, electricity and other charges and
costs of tools and plants etc. all complete and accepted by the Engineer -in-
3.4.1 Mass concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 cum Tk. 6,647.00
3.4.2 Mass concrete in floor (1:3:6) with cement brick chips and sand of F.M. 1.2 cum Tk. 6,579.00
3.5 Mass concrete (1:2:4) in foundation or floor with cement, sand (F.M. 1.2) and picked
jhama chips including breaking chips, screening, mixing, laying, compacting to levels and
curing for at least 7 days including the supply of water, electricity and other charges and
costs of tools and plants etc. all complete and accepted by the Engineer -in-
charge.
(Cement: CEM-II/A-M)
3.5.1 Mass concrete in foundation (1:2:4) with brick chips and local sand of F.M. 1.2 cum Tk. 7,643.00
3.5.2 Mass concrete in floor (1:2:4) with brick chips and local sand of F.M. 1.2 cum Tk. 7,575.00
56
3.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square sqm. Tk. 42.00
meter in floor or any where below cement concrete complete in all respect and accepted by
the Engineer -in-
charge.
3.8 Extra rate for mass concrete work in additional floor:
3.8.1 Add for each additional floor up to 5th floor cum Tk. 102.00
3.8.2 Add for each additional floor for 6th floor to 9th floor cum Tk. 136.00
3.8.3 Add for each additional floor for 10th floor & above cum Tk. 171.00
DIVISION 04 : BRICK WORKS, PATENT STONE IN FLOOR AND FANCY
SCREEN BLOCK WORK
4.1 Brick works with first class bricks in cement sand (F.M. of sand 1.2) mortar (1:6) in cum Tk. 6,040.00
foundation and plinth, filling the joints/interstices fully with mortar, racking out the joints,
cleaning and soaking the bricks at least for 24 hours before use and curing at least for 7 days
etc. all complete including cost of water, electricity and other charges and accepted by the
Engineer -in-
charge.
(Cement: CEM-II/A-M)
4.2 Brick works of width one brick or one and a half brick length with first class bricks in cum Tk. 6,443.00
cement sand (F.M. 1.2) mortar (1:6) in superstructure including raking out joints, filling
the interstices with mortar, cleaning and soaking the bricks at least for 24 hours before use
and washing of sand, necessary scaffolding, curing at least for 7 days etc. all complete
(measurement to given as 250 mm width for one brick length and 375 mm for one brick and
a half brick length) and accepted by the Engineer -in-
charge.
4.3 Brick works with first class bricks in cement sand (F.M. 1.2) mortar (1:4) in exterior cum Tk. 6,769.00
walls including filling the interstices with mortar, raking out joints, cleaning and socking the
bricks at least for 24 hours before use and washing of sand, necessary scaffolding, curing at
least for 7 days etc. all complete including cost of water, electricity and other charges
(measurement to given as 250 mm width for one brick length and 375 mm for one brick and
a half brick length) accepted by the Engineer -in-
charge.
(Cement: CEM-II/A-M)
In ground floor
4.4 Exposed brick works (for exterior wall without outside plaster) with special quality cum Tk. 7,894.00
sorted out first class bricks, very carefully laid in cement sand (F.M. 1.2) mortar (1:4)) in
superstructure with uniform width and depth joints, true to vertical and horizontal lines
including raking out joints scaffolding, soaking the bricks at least for 24 hours before use,
washing and screening of sand. Curing at least for 7 days and high class flush pointing with
cement sand (F.M. 1.2) mortar (1:1) including cost of water, electricity and other charges
etc all complete and accepted by the Engineer -in-
charge.(Cement: CEM-II/A-M) In ground floor
57
4.7 Brick work with 241 mm x 114 mm x 70 mm size machine made solid klinker facing cum Tk. 9,286.00
bricks having uniform colour carefully laid in cement sand (F.M. 1.2) mortar (1:4) in
superstructure with uniform width and depth joints, true to vertical and horizontal lines
including raking out joints, filling the interstices with mortar, cleaning and soaking bricks at
least for 24 hours before use and washing and screening of sand, necessary scaffolding,
curing at least for 7 days and pointing with cement sand (F.M. 1.2) mortar (1:2) including
cost of water, electricity and other charges etc. complete and accepted by the Engineer -in-
charge.(Cement: CEM-II/A-M) In ground floor
4.8 Brick works with 241 mm x 114 mm x 70 mm size 10 hole machine made Rock-face or cum Tk. 9,167.00
textured klinker facing bricks having uniform colour carefully laid in cement sand (F.M.
1.2) mortar (1:4) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints, filling the interstices with mortar, cleaning
and soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curing at least for 7 days and pointing with cement sand (F.M. 1.2)
mortar (1:2) including cost of water, electricity and other charges etc. all complete and
accepted by the Engineer -in-
charge. (Cement: CEM-II/A-M)
In ground floor
4.9 Brick works with 241 mm x 114 mm x 70 mm size 3 hole machine made reinforced cum Tk. 13,380.00
klinker facing bricks having uniform colour carefully laid in cement sand (F.M.1.2) mortar
(1:4) in superstructure with uniform width and depth joints, true to vertical and horizontal
lines including raking out joints, filling the interstices with mortar, cleaning and soaking
bricks at least for 24 hours before use and washing and screening of sand, necessary
scaffolding, curing at least for 7 days and pointing with cement sand (F.M. 1.2) mortar (1:2)
including cost of water, electricity and other charges etc. all complete and accepted by the
Engineer -in-
charge.
(Cement: CEM-II/A-M)
In ground floor
4.1 Extra cost shall be incorporated in the estimate for each additional floor for brick works
(item No.- 4.2 to 4.9)
4.10.1 Add for each additional floor up to 5th floor cum Tk. 171.00
4.10.2 Add for each additional floor from 6th floor to 9th floor cum Tk. 239.00
4.10.3 Add for each additional floor for 10th floor and above cum Tk. 273.00
4.11 Extra cost for brick-work for each additional meter (or part of meter) free height of cum Tk. 174.00
brick wall beyond 4 m from the respective floor in auditorium, go-down, overhead water
tank etc. as description of the item No. 4.2 to 4.9 including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer-in-charge. (Extra cost shall
be incorporated in the estimate only when both sides of wall is uninterruptedly free beyond
58
4.14.5 With 241 mm x 70 mm x 12.7 mm matt glazed textured strip sqm. Tk. 3,006.00
4.15 125 mm brick work with first class bricks in cement sand (F.M. 1.2) mortar (1:6) and sqm. Tk. 917.00
making bond with connected walls including necessary scaffolding, raking out joints,
cleaning and soaking the bricks for at least 24 hours before use and washing of sand curing
at least for 7 days in all floors including cost of water, electricity and other charges etc. all
complete and accepted by the Engineer -in-
4.16 125 mm brick works with first class bricks in cement sand (F.M. 1.2) mortar (1:4) and sqm. Tk. 948.00
making bond with connected walls including necessary scaffolding, raking out joints,
cleaning and soaking the bricks for at least 24 hours before use and washing of sand curing
at least for 7 days in all floors including cost of water, electricity and other charges etc. all
4.17 Exposed 125 mm thick pointing ornamental brick work with sorted out first class sqm. Tk. 1,155.00
bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond with connected walls
including necessary scaffolding, raking out joints, cleaning and soaking the bricks for at
least 24 hours before use and washing of sand, curing at least for 7 days in all floors
including cost of water, electricity and other charges etc. all complete and accepted by the
Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
4.18 Exposed 125 mm thick pointing ornamental brick work with automatic machine sqm. Tk. 1,082.00
made first class bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond with
connected walls including necessary scaffolding, raking out joints, cleaning and soaking
the bricks for at least 24 hours before use and washing of sand, curing at least for 7 days
in all floors including cost of water, electricity and other charges etc. all complete and
accepted by the Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
59
4.20.2 With design block size: 140 mm x 140 mm x 102 mm or equivalent volume & design. sqm. Tk. 2,873.00
In ground floor
4.20.3 With design block size: 152 mm x 152 mm x 102 mm or 152 mm x 152 mm x 114 mm or sqm. Tk. 2,639.00
equivalent volume and design.
4.20.4 With design block size: 203 mm x 203 mm x 108 mm or equivalent volume and design. sqm. Tk. 1,953.00
In ground floor
4.20.5 With design block size: 203 mm x 121 mm x 102 mm or equivalent volume and design. sqm. Tk. 2,167.00
In ground floor
4.20.6 With design block size: 152 mm x 152 mm x 152 mm or equivalent volume and design. sqm. Tk. 2,639.00
In ground floor
4.20.7 With design block size: 241 mm x 114 mm x 70 mm or equivalent volume and design. sqm. Tk. 2,062.00
In ground floor
4.21 Extra cost shall be incorporated in the estimate for each additional floor for brick and
screen block works (item No.- 4.12 to 4.20)
4.21.1 Add for each additional floor up to 5th floor sqm. Tk. 31.00
4.21.2 Add for each additional floor from 6th floor to 9th floor sqm. Tk. 42.00
4.21.3 Add for each additional floor for 10th floor and above sqm. Tk. 52.00
4.22 Klinker paving brick works in floor or pavement with machine made pressed bricks of
approved quality in cement sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick cement
sand (F.M. 1.2) mortar (1:4) including raking out joints, cutting the bricks to required size
soaking the same 24 hours before use wherever necessary including high class flush pointing
in cement mortar (1:2), cleaning, curing at least for 7 days etc. including washing and
screening of sand, cost of water, electricity and other charges complete and standard
practice accepted by the Engineer- in- charge. (Cement: CEM-II/A-M)
4.22.1 100 mm thick brick on edge pavement with 200 x 100 x 50 mm size klinker facing bricks. sqm. Tk. 2,740.00
4.22.2 50 mm thick flat brick pavement with 200 x 100 x 50 mm klinker paving bricks in 1:4 sqm. Tk. 1,620.00
cement sand mortar having 200 x 100 mm face at top.
4.22.3 50 mm thick brick pavement with 200 x 50 x 50 mm klinker facing bricks. sqm. Tk. 2,315.00
4.23 125 mm thick brick pavement or flooring with first class brick on edge in cement sand sqm. Tk. 1,079.00
(F.M. 1.2) mortar (1:4) on minimum 12 mm thick cement sand (F.M. 1.2) mortar (1:4)
including cutting the bricks as per requirement, cleaning and racking out joints, finishing
with flush pointing with cement sand (F.M. 1.2) mortar (1:2) and curing for at least 7 days
etc. including cost of water, washing and screening of sand (F.M. 1.2), electricity and other
charges complete and standard practice accepted by the Engineer- in- charge. (Cement:
CEM-II/A-M)
60
5.2.2 With Pakistani chips and glass strip. sqm. Tk. 1,892.00
In ground floor
5.2.3 With Indian chips without glass strip. sqm. Tk. 1,620.00
In ground floor
5.2.4 With Pakistani chips without glass strip. sqm. Tk. 1,656.00
In ground floor
5.3 10 mm thick finished and laying thickness 12.5 mm silver grey situ mosaic work on floor
with one part of 10 mm machine crushed well graded, dust free and properly washed marble
chips and one part of mixture containing white cement and grey cement in proportion (1:1)
including preparation of mix and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick-chips (1:2:4) including making suitable panel, compacting,
curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No. 120) and finishing
with Minar stone including breaking brick chips, screening, washing mosaic chips and
supply of all necessary materials including and water, electricity and other charges in all
respect accepted by the Engineer -in-charge.
5.3.1 With Indian chips and with glass strip. sqm. Tk. 1,623.00
In ground floor
5.3.2 With Pakistani chips and with glass strip. sqm. Tk. 1,655.00
In ground floor
62
5.3.4 With Pakistani chips without glass strip. sqm. Tk. 1,419.00
In ground floor
5.4 12 mm thick finished and laying thickness 14.5 mm silver grey cast in situ mosaic work on
floor with one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture containing white cement dust free and properly
washed marble chips and one part of mixture containing white cement and grey with cement
in proportion (1:1) including. preparation of mix and laying the same over minimum 25 mm
thick artificial patent stone flooring with brick-chips (1:2:4) including making suitable
panels, compacting, curing at least for 7 days, cutting with pumic stone (No. 40. No. 80,
No. 120) and finishing with Minar stone including breaking brick chips, screening, washing
mosaic chips and supply of all necessary materials and water, electricity and other charges in
all respect accepted by the Engineer -in-charge.
5.4.1 With Indian chips and with glass strip. sqm. Tk. 1,691.00
In ground floor
5.4.2 With Pakistani chips and with glass strip. sqm. Tk. 1,727.00
In ground floor
5.4.3 With Indian chips without glass strip. sqm. Tk. 1,455.00
In ground floor
5.4.4 With Pakistani chips without glass strip. sqm. Tk. 1,491.00
In ground floor
5.5 10 mm thick finished and laying thickness 12.5 mm situ mosaic work on wall with one
part of 10 mm machine crushed well graded dust free and properly washed marble chips
and one part of mixture containing 100% white cement including preparation of mix and
laying the same on 12 mm thick cement plaster (1:4) to wall, compacting, curing at least for
7 days, cutting with pumic stone (No. 40, No. 80, No. 120) including finishing the corners
and edges and also finishing with Minar stone and supplying all necessary materials in and
water, electricity and other charges in all respect accepted by the Engineer -in-charge.
5.5.1 With Indian chips. sqm. Tk. 1,724.00
In ground floor
5.5.2 With Pakistani chips. sqm. Tk. 1,757.00
In ground floor
5.6 10 mm thick finished and laying thickness silver grey situ mosaic work on wall with one
part of 10 mm machine crushed well graded, dust free and properly washed marble chips
and one part of mixture containing white cement and grey cement in proportion (1:1)
including preparation of mix. and laying the same on 12 mm thick cement plaster (1:4) to
wall, compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No
120) including finishing the corners and edges and also finishing with Minar stone and
supplying all necessary materials in and water, electricity and other charges in all respect
5.6.1 With Indian chips. sqm. Tk. 1,577.00
In ground floor
5.6.2 With Pakistani chips. sqm. Tk. 1,610.00
In ground floor
5.6.3 With Indian chips using 100% grey cement. sqm. Tk. 1,430.00
In ground floor
63
5.7.2 With Pakistani chips and with glass strip. sqm. Tk. 1,875.00
In ground floor
5.7.3 With Indian chips without glass strip. sqm. Tk. 1,387.00
In ground floor
5.7.4 With Pakistani chips without glass strip. sqm. Tk. 1,492.00
In ground floor
5.8 12 mm thick finished and laying thickness 14 mm coloured situ mosaic on floor with one
part of 10 mm machine crushed well graded, dust free and properly washed marble chips
and one part of mixture containing white cement and grey cement in proportion (9:1) and
necessary quantity of approved colourings materials including preparation of mix and laying
the same over minimum 25 mm thick artificial patent stone flooring with brick-chips (1:2:4)
including making suitable panel, compacting, curing at least for 7 days, cutting with pumic
stone (No. 40, No. 80, No. 120) and finishing with Minar stone including breaking brick
chips, screening, washing mosaic chips and supply of all necessary materials in all respects
and water, electricity and other charges in all respect accepted by the Engineer -in-charge.
(Cement: CEM-II/A-M)
5.8.1 With Indian chips and with glass strip. sqm. Tk. 1,928.00
In ground floor
5.8.2 With Pakistani chips and with glass strip. sqm. Tk. 1,965.00
In ground floor
5.8.3 With Indian chips and without glass strip. sqm. Tk. 1,692.00
In ground floor
5.8.4 With Pakistani chips and without glass strip. sqm. Tk. 1,729.00
In ground floor
5.9 10 mm thick finished and laying thickness 12.5 mm coloured situ mosaic on walls with
one part of 10 mm machine crushed well graded, dust free and properly washed marble
chips and one part of mixture containing white cement and grey cement in proportion (9:1)
and necessary quantity of approved colouring materials including preparation of mix and
laying the same on 12 mm thick cement sand (F.M. 1.2) plaster (1:4) to walks including
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No. 120)
including finishing the corners and edges and also finishing with Minar stone and supply of
all necessary materials etc. and water, electricity and other charges complete in all respect
5.9.1 With Indian chips. sqm. Tk. 1,797.00
In ground floor
5.9.2 With Pakistani chips. sqm. Tk. 1,829.00
In ground floor
64
6.1 Supplying, fitting and fixing country made GP(Gress Porcellanto) - glazed or unglazed
homogeneous floor tiles complying BDS ISO 13006: 2015, water absorbtion ≤ 0.5%,
modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, with cement
sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care etc. all complete and
accepted by the Engineer-in-charge. (Cement: CEM-II/A-M). In ground floor
6.2.1 GP (mirror polished) 400 mm x 400 mm floor tiles sqm. Tk. 1,799.00
6.2.2 GP (mirror polished) 500 mm x 500 mm floor tiles sqm. Tk. 1,935.00
6.2.3 GP (mirror polished) 600 mm x 600 mm floor tiles sqm. Tk. 2,072.00
6.2.4 GP (mirror polished) 800 mm x 800 mm floor tiles sqm. Tk. 2,208.00
6.2.5 GP (mirror polished) 600 mm x 900 mm floor tiles sqm. Tk. 2,509.00
6.2.6 GP (mirror polished) 600 mm x 1200 mm floor tiles sqm. Tk. 2,959.00
6.3 Supplying, fitting and fixing country made homogeneous matt finished/ rustic floor
tiles complying BDS ISO 13006: 2015, water absorbtion ≤ 0.5%, modulus of rupture
(MOR) ≥ 27 N/mm2, irrespective of color &/or design, with cement sand (F.M. 1.2)
mortar (1:4) base and raking out the joints with white cement including cutting and laying
the tiles in proper way and finishing with care etc. all complete and accepted by the
Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
6.3.1 Matt or rustic floor tiles of size 400 mm x 400 mm and below sqm. Tk. 1,894.00
6.3.2 Matt or rustic floor tiles of size 600 mm x 600 mm and below sqm. Tk. 2,113.00
65
6.4.1 Polish pocelain/ mirror polished 600 mm x 600 mm floor tiles sqm. Tk. 2,413.00
6.4.2 Polished pocelain/ mirror polished 800 mm x 800 mm floor tiles sqm. Tk. 2,754.00
6.4.3 Polished pocelain/ mirror polished 600 mm x 1200 mm floor tiles sqm. Tk. 4,801.00
6.4.4 Polished pocelain/ mirror polished 1000 mm x 1000 mm floor tiles sqm. Tk. 6,166.00
6.4.5 Polished pocelain/ mirror polished 1200 mm x 1200 mm floor tiles sqm. Tk. 7,531.00
6.5 Supplying, fitting and fixing foreign (China or equivalent) made homogeneous matt
finished/ rustic floor tiles complying BDS ISO 13006: 2015, water absorbtion ≤ 0.5%,
modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, with cement
sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care etc. all complete and
accepted by the Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
6.5.1 Matt or rustic floor tiles of size 600 mm x 600 mm sqm. Tk. 3,027.00
6.6 Supplying, fitting and fixing country made glazed wall tiles complying BDS ISO 13006:
2015, irrespective of color &/or design, with 20 mm thick cement sand (F.M. 1.2) mortar
(1:3) base and raking out the joints with white cement including cutting, laying and hire
charge of machine and finishing with care etc. including cost of water, electricity and other
charges complete in all respect and accepted by the Engineer-in-charge. (Cement: CEMII/
6.6.1 Wall tiles less than, equal or equivalent to 250 mm x 330 mm in sizes sqm. Tk. 1,271.00
6.6.2 Wall tiles more than 250 mm x 330 mm & less than or equal to 250 mm x 400 mm in sizes sqm. Tk. 1,571.00
6.6.3 Wall tiles more than 250 mm x 400 mm & less than or equal to 300 mm x 600 mm in sizes sqm. Tk. 1,817.00
6.6.4 Decor wall tiles of any size sqm. Tk. 2,090.00
6.6.5 Border wall tiles of any size sqm. Tk. 4,410.00
6.7 Supplying, fitting and fixing country made rustic or matt finished wall tiles complying
BDS ISO 13006: 2015, irrespective of color &/or design, with 20 mm thick cement sand
(F.M. 1.2) mortar (1:3) base and raking out the joints with white cement including cutting,
laying and hire charge of machine and finishing with care etc. including water, electricity
and other charges complete in all respect and accepted by the Engineer-in-charge.
(Cement: CEM-II/A-M). In ground floor
6.7.1 Matt or rustic wall tiles less than or equal to 300 mm x 600 mm size sqm. Tk. 1,954.00
6.8 Supplying, fitting and fixing foreign (China or equivalent) made glazed wall tiles
complying BDS ISO 13006: 2015, irrespective of color &/or design, with 20 mm thick
cement sand (F.M. 1.2) mortar (1:3) base and raking out the joints with white cement
including cutting, laying and hire charge of machine and finishing with care etc. including
water, electricity and other charges complete in all respect and accepted by the Engineerin-
charge. (Cement: CEM-II/A-M). In ground floor
6.8.1 Glazed wall tiles 300 mm x 600 mm in sizes along with maching floor tiles, decor and sqm. Tk. 2,772.00
6.9 Supplying, fitting and fixing foreign (China or equivalent) made rustic or matt finished
wall tiles complying BDS ISO 13006: 2015, irrespective of color &/or design, with 20
mm thick cement sand (F.M. 1.2) mortar (1:3) base and raking out the joints with white
cement including cutting, laying and hire charge of machine and finishing with care etc.
including water, electricity and other charges complete in all respect and accepted by the
Engineer-in-charge. (Cement: CEM-II/A-M). In ground floor
6.9.1 Matt or rustic wall tiles 300 mm x 600 mm in sizes along with matching floor tiles, decor sqm. Tk. 2,772.00
and border titles (if any)
66
6.10.1 Glazed stair tiles having size of width 250 mm to 300 mm and length 300 mm sqm Tk. sqm. Tk. 1,553.00
6.10.2 Glazed stair tiles having size of width 250 mm to 300 mm and length 325 mm to 600 mm sqm. Tk. 2,004.00
6.11 Supplying, fitting and fixing country made rustic or matt finished stair tiles complying
BDS ISO 13006: 2015, water absorbtion ≤ 0.5%, modulus of rupture (MOR) ≥ 27
N/mm2, irrespective of color &/or design, with 20 mm thick cement sand (F.M. 1.2)
mortar (1:3) base and raking out the joints with white cement including cutting, laying and
hire charge of machine and finishing with care etc. including water, electricity and other
charges complete in all respect and accepted by the Engineer-in-charge. (Cement: CEMII/
A-M). In ground floor
6.11.1 Rustic stair tiles of size 300 mm x 600 mm sqm. Tk. 1,935.00
6.12 Supplying, fitting and fixing foreign (China or equivalent) made GP homogeneous stair
tiles having non skidding offsets, complying BDS ISO 13006: 2015, water absorbtion
≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design,
with cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement
including cutting and laying the tiles in proper way and finishing with care etc. all complete
and accepted by the Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
6.12.1 Glazed stair tiles of size 300 mm x 600 mm sqm. Tk. 2,072.00
6.13 Supplying, fitting and fixing foreign (China or equivalent) made rustic or matt finished
stair tiles complying BDS ISO 13006: 2015, water absorbtion ≤ 0.5%, modulus of
rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, with 20 mm thick cement
sand (F.M. 1.2) mortar (1:3) base and raking out the joints with white cement including
cutting, laying and hire charge of machine and finishing with care etc. including water,
electricity and other charges complete in all respect and accepted by the Engineer-incharge.
(Cement: CEM-II/A-M). In ground floor
6.13.1 Rustic stair tiles of size 300 mm x 600 mm sqm. Tk. 2,004.00
6.14 Supplying, fitting and fixing country made floor tiles complying BDS ISO 13006: 2015,
water absorbtion ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color
&/or design, with adhesives in full thickness of tiles, filler/tiles grout including cutting,
shaping, placing in proper level etc. all complete and accepted by the Engineer-in-charge.
In ground floor
6.14.1 GP glazed / unglazed homogenous floor tiles (400 mm x 400 mm) sqm. Tk. 1,864.00
6.14.2 GP glazed / unglazed homogenous floor tiles (300 mm x 300 mm) sqm. Tk. 1,273.00
6.14.3 GP mirror polished floor tiles (300 mm x 300 mm) sqm. Tk. 1,341.00
6.14.4 GP mirror polished floor tiles (400 mm x 400 mm) sqm. Tk. 1,546.00
6.14.5 GP mirror polished floor tiles (600 mm x 600 mm) sqm. Tk. 1,891.00
6.14.6 mirror polished floor tiles (800 mm x 800 mm) sqm. Tk. 1,956.00
6.14.7 GP mirror polished floor tiles (600 mm x 900 mm) sqm. Tk. 2,256.00
6.15 Supplying, fitting and fixing foreign made (China or equivalent) floor tiles complying
BDS ISO 13006: 2015, water absorbtion ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2,
irrespective of color &/or design, with adhesives in full thickness of tiles, filler/tiles grout
including cutting, shaping, placing in proper level etc. all complete as direction of the
Engineer-in-charge. In ground floor
6.15.1 GP mirror polished floor tiles (600 mm x 600 mm) sqm. Tk. 2,160.00
6.15.2 GP mirror polished floor tiles (800 mm x 800 mm) sqm. Tk. 2,501.00
6.15.3 GP mirror polished floor tiles (600 mm x 1200 mm) sqm. Tk. 4,548.00
67
6.17.2 Roof tiles of size 125 mm x 170 mm to 200 mm x 200 mm or equivalent (red colour) sqm. Tk. 3,171.00
6.17.3 Roof tiles of size 160 mm x 268 mm or equivalent (red colour) sqm. Tk. 2,901.00
6.17.4 Roof tiles of size 225 mm x 300 mm or larger (red colour) sqm. Tk. 2,983.00
6.17.5 Flower shaped roof tiles of size 175 mm x 175 mm or equivalent (red colour) sqm. Tk. 3,832.00
6.17.6 Roof tiles of size 100 mm x 200 mm or equivalent (beige colour) sqm. Tk. 2,751.00
6.17.7 Roof tiles of size 125 mm x170 mm to 200 mm x 200 mm or equivalent (beige colour) sqm. Tk. 3,297.00
6.17.8 Roof tiles of size 225 mm x 300 mm or larger (beige colour) sqm. Tk. 3,229.00
6.17.9 Flower shaped roof tiles of size 175 mm x 175 mm or equivalent (beige colour) sqm. Tk. 3,993.00
6.17.10 Roof tiles of size 125 mm x 170 mm to 200 mm x 200 mm or equivalent (grey or black sqm. Tk. 3,297.00
6.17.11 Flower shaped roof tiles of size 175 mm x 175 mm or equivalent (grey or black colour) sqm. Tk. 4,348.00
6.18 Marble stone flooring with Indian standard quality (Bansowara/ Indian grey/ Indian pink
or equivalent) marble stone of approved quality, texture and size with 25 mm thick cement
sand (F.M. 1.2) mortar (1:2) including placing cement slurry below the stone, cutting the
marble stone to desired size, grinding and finishing the edges, setting in position in proper
level, filling the gaps with white cement and colouring pigments including supplying all
necessary equipments/materials and finishing the top by pumice stone and necessary
auxiliary materials and water, electricity and other charges complete in all respect and
accepted by the Engineer in charge. (Cement: CEM-II/A-M).
6.19 Marble stone flooring with Indian superior quality marble stone of approved quality,
texture and size with 25 mm thick cement sand (F.M. 1.2) mortar (1:2) including placing
cement slurry below the stone, cutting the marble stone to desired size, grinding and
finishing the edges, setting in position in proper level, filling the gaps with white cement
and colouring pigments including supplying all necessary equipments/materials and
finishing the top by pumice stone and necessary auxiliary materials and water, electricity
and other charges complete in all respect and accepted by the Engineer in charge.
(Cement: CEM-II/A-M)
6.19.1 18 mm thick marble stone flooring sqm. Tk. 7,975.00
In ground floor
6.19.2 16 mm thick marble stone flooring sqm. Tk. 6,935.00
In ground floor
68
6.20.2 Supplying and setting 12 mm thick Indian superior quality marble stone of approved sqm. Tk. 6,676.00
quality, texture and size on wall with 12 mm thick cement sand (F.M. 1.2) mortar (1:2)
including cutting and grinding the marble stone slab/tile, setting in position keeping
horizontal and vertical alignment correct, filling the joints with white cement, cutting and
grinding the top surface, finishing etc including water, electricity and other charges
complete in all respect and accepted by the Engineer-in-charge. (Cement: CEM-II/A-M) In
ground floor
6.21.1 Marble stone flooring with 18mm thick Italian or equivalent marble stone of approved sqm. Tk. 9,924.00
quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2) including.
placing cement slurry below the stone, cutting the marble stone to desired size, grinding
and finishing the edges, setting in position in proper level, filling the gaps with white
cement and colouring pigments including supplying all necessary equipments/materials
and finishing the top by pumice stone and necessary auxiliary materials and water,
electricity and other charges complete in all respect and accepted by the Engineer-incharge.
(Cement: CEM-II/A-M). In ground floor.
6.21.2 Supplying and setting 12 mm thick Italian or equivalent quality marble stone on wall of sqm. Tk. 9,276.00
approved quality, texture and size on wall with 12 mm thick cement sand (F.M. 1.2) mortar
(1:2) including cutting and grinding the marble stone slab/tile, setting in position keeping
horizontal and vertical alignment correct, filling the joints with white cement, cutting and
grinding the top surface, finishing etc including water, electricity and other charges
complete in all respect and accepted by the Engineer-in-charge. (Cement: CEM-II/A-M) In
ground floor
6.22 Labour cost for making moulding in marble stone as per architectural drawing
including cutting, grinding, finishing, supplying necessary equipment etc. complete in all
respect and accepted by the Engineer in Charge. (Cement: CEM-II/A-M).
6.24 Granite stone flooring with 18 mm thick Italian or equivalent origin granite stone of sqm. Tk. 9,924.00
approved quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the granite stone to desired size,
grinding and finishing the edges, setting in position in proper level, filling the gaps with
white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumice stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect and accepted by
the Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
69
6.26 Supplying and setting 12 mm thick Italian or equivalent granite stone of approved sqm. Tk. 7,976.00
quality, texture and size on wall with 12 mm thick cement sand (F.M. 1.2) mortar (1:2)
including cutting and grinding the granite stone slab, setting in position keeping horizontal
and vertical alignment correct, filling the joints with white cement, cutting and grinding the
top surface, finishing etc including water, electricity and other charges complete in all
respect and accepted by the Engineer-in-charge. (Cement: CEM-II/A-M) In ground floor
6.27 Extra rate for each additional floor for tiles works
6.27.1 Add for each additional floor up to 5th floor sqm. Tk. 10.00
6.27.2 Add for each additional floor for 6th floor to 9th floor sqm. Tk. 21.00
6.27.3 Add for each additional floor for 10th floor and above sqm. Tk. 31.00
6.28 Extra rate for each additional floor for marble and granite stone works
6.28.1 Add for each additional floor up to 5th floor sqm. Tk. 15.00
6.28.2 Add for each additional floor for 6th floor to 9th floor sqm. Tk. 27.00
6.28.3 Add for each additional floor for 10th floor and above sqm. Tk. 35.00
7.1.3 Floor / roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair cum Tk. 7,602.00
case slab
7.1.4 Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and cum Tk. 7,944.00
ribbed floor slab
RCC WORKS: 1:2:4 (measured on gross concrete section)
(f 'c = 22 MPa, minimum f 'cr = 27 MPa in nominal mix 1:2:4), with stone chips
(100% sand of F.M. 2.2 )
70
7.2 Reinforced cement concrete works with minimum cement content relates to mix
ratio 1:2:4
having minimum f'cr = 27 MPa, satisfying a specified compressive strength f'c = 22
MPa at
28 days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM,
cement
conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type – I,
best
quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well
graded
stone chips conforming to ASTM C-33, making and placing shutter in position
maintaining
true to plumb, making shutter water-tight properly, placing reinforcement in
position;
7.2.1 Individual and Combined footings Individual & combined footing, pile cap, cum Tk. 11,817.00
raft/mat, floor slab and foundation beam up to
plinth level
7.2.2 Pedestals, column, column capital, lift wall and RCC wall up to ground floor cum Tk. 12,031.00
7.2.3 Floor / roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair cum Tk. 11,903.00
case slab
7.2.4 Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and cum Tk. 12,243.00
ribbed floor slab
RCC WORKS: 1:1.5:3 (measured on gross concrete section)
(f'c = 25MPa, minimum f'cr = 30 MPa in nominal mix 1 : 1.5 : 3), with stone
chips
(100% sand of F.M. 2.2)
7.3 Reinforced cement concrete works with minimum cement content relates to mix
ratio
1:1.5:3 having minimum f'cr = 30 MPa, satisfying a specified compressive strength
f‟c = 25
MPa at 28 days on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM,
Cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150
Type – I,
best quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down
well
graded stone chips conforming to ASTM C-33, making and placing shutter in
position and
maintaining true to plumb, making shutter water-tight properly, placing
reinforcement in
7.3.1 Individual & combined footing, pile cap, raft/mat, floor slab and foundation cum Tk. 12,154.00
beam up to
7.3.2 Pedestals, column, column capital, lift wall and RCC wall up to ground floor cum Tk. 12,367.00
7.3.3 Floor / roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair cum Tk. 12,240.00
case slab
and steps etc. upto ground floor
7.3.4 Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and cum Tk. 12,580.00
ribbed floor slab
7.4 RCC WORKS : 1:1.25:2.5 (measured on gross concrete section)
(f'c = 32 MPa, minimum f'cr = 40 MPa in nominal mix 1 : 1.25 : 2.5) with stone
chips
71
Reinforced cement concrete works with minimum cement content relates to mix
ratio
1:1.25:2.5 having minimum f'cr = 40 MPa, satisfying a specified compressive
strength f‟c =
32 MPa at 28 days on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM, Cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5
MPa)/
ASTM-C 150 Type – I, and adding approved high range water reducing
admixture of
complying specific type (generally be Type-G) under ASTM-C 494, best quality
coarse
sand [Sylhet sand or coarse sand of equivalent F.M. 2.2], 20 mm down well
graded
crushed stone chips conforming to ASTM C-33, including screening sand
through proper
sieves, making and placing shutter in position and maintaining true to plumb,
7.4.1 Individual & combined footing, pile cap, raft/mat, floor slab and foundation cum Tk. 12,154.00
beam up to
plinth level
7.4.2 Padestal, column, column capital, lift wall and RCC wall up to ground floor cum Tk. 12,367.00
7.4.3 Floor / roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair cum Tk. 12,240.00
case slab
and steps etc. up to ground floor
7.4.4 Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and cum Tk. 12,580.00
ribbed floor slab
etc. up to ground floor
7.5 RCC WORKS: 1:1:2 (measured on gross concrete section)
(f'c = 40 MPa, minimum f'cr = 49 MPa in nominal mix 1 : 1 : 2) with stone chips
and
admixture (high strength concrete) (100% sand of F.M. 2.2)
Reinforced cement concrete works with minimum cement content relates to mix
ratio 1:1:2
having minimum f'cr = 49 Mpa, satisfying a specified compressive strength f‟c
= 40 MPa at
28 days on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM,
Cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C
150 Type – I,
and adding approved high range water reducing admixture of complying
specific type
(generally be Type-G) under ASTM-C 494, best quality coarse sand [Sylhet
sand or
coarse sand of equivalent F.M. 2.2], 20 mm down well graded crushed stone
chips
7.5.1 conforming&tocombined
Individual ASTM C-33, making
footing, and placing
pile cap, shutter
raft/mat, in position
floor slab and
and foundation cum Tk. 12,920.00
beam up to
plinth level
7.5.2 Pedestal, column, column capital, lift wall and RCC wall upto ground floor cum Tk. 13,134.00
7.6 Fair-faced RCC WORKS: 1:1.5:3 (measured on gross concrete section)
(f'c = 25 MPa, minimum f'cr = 30 MPa in nominal mix 1:1.5:3)
(100% sand of F.M. 2.2)
72
Cast-in-place fair-faced concrete works with f'cr=30 Mpa and f'c=25 Mpa at 28
days on
standard cylinders by using 75% of OPC and 25% of white cement conforming
to BDS
EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type – I, best quality
Sylhet sand or
coarse sand of equivalent F.M. 2.2, 20 mm down and well graded stone chips
conforming
to ASTM C-33 at mix ratio of 1:1.5:3, adding coloring pigment as per
architectural design,
conforming to the standard practice of code ACI/BNBC/ASTM including
screening sand
and chips through proper sieves, washing, making and placing shutter in
position
maintaining true to plumb, making shutter water tight properly, placing
reinforcement in
position, including pouring of concrete in form, compacting by vibrator
machine and curing
at least for 28 days, removing centering-shuttering after specified time
approved; including
cost of water, electricity, testing charges of materials and cylinders as required,
other
charges etc. all complete, approved and accepted by the Engineer-in-charge.
(Rate is
7.6.1 excluding
For thewall,
column, costbeam,
of reinforcement andcornice
slab, drop wall, its fabrication,
etc. up toplacing, binding etc, and
ground floor cum Tk. 15,185.00
7.7 Extra rate for RCC works/fair-faced concrete works (materials, consumables and cum Tk. 251.00
laying/placing concrete) in column, column capital, lift wall & wall, T- beam, L-
beam,
rectangular beams, floor / roof slab, cantilever slab, waffle slab and drop panels
where the
7.8 Extra rate for RCC work/fair-faced work in additional floor: concrete
7.8.1 Add for each additional floor up to 5th floor cum Tk. 108.00
7.8.2 Add for each additional floor for 6th floor to 9th floor cum Tk. 145.00
7.8.3 Add for each additional floor for 10th floor & above cum Tk. 181.00
FORM WORK (Steel)
7.9 Centering and shuttering, including strutting, propping etc. (The formwork must be
rigid enough both in and out of plane, to make the concrete surface true to the
designed
shape and size by using necessary MS sheets of minimum 16 BWG, angles of
minimum
7.9.1 Individual and combined footing sqm Tk. 438.00
7.9.2 In raft/mat/floor slab up to plinth level sqm Tk. 434.00
7.9.3 Foundation beam sqm Tk. 380.00
7.9.4 Pedestal, column, column capital, lift wall and wall up to ground floor sqm Tk. 408.00
7.9.5 Tie beam and lintel: ground floor sqm Tk. 419.00
7.9.6 T-beam, L-beam and rectangular beam etc up to ground floor sqm Tk. 455.00
7.9.7 Floor and roof slab up to ground floor sqm Tk. 532.00
7.9.8 Cornice, railing, drop walls, louver, fins etc.: ground floor sqm Tk. 387.00
7.9.9 Sunshade, false ceiling: ground floor sqm Tk. 438.00
7.9.10 Stair case slab and steps up to ground floor sqm Tk. 437.00
7.9.11 Waffle or ribbed floor upto ground floor sqm Tk. 578.00
7.9.12.1 Arches, domes, vaults up to 8m span (for single use) sqm Tk. 1,830.00
7.9.12.2 Arches, domes, vaults up to 8 m span (for 2-times use) sqm Tk. 1,281.00
7.9.12.3 Arches, domes, vaults up to 8 m span (for 3-times use) sqm Tk. 915.00
73
7.9.12.4 Arches, domes, vaults up to 8 m span (for more than 3-times use) sqm Tk. 641.00
7.10.0 Extra rate for arches, domes, vaults exceeding 8 m span sqm Tk. 458.00
7.11 Extra rate for shuttering in circular work sqm Tk. 91.00
7.12 Extra rate for additional height in centering, shuttering where ever required with sqm Tk. 45.00
adequate
bracing, propping etc. over a height of 4.0 m, for every additional height of 1 metre
or part
thereof.
7.13 Extra rate for formwork/shuttering in additional floor
7.13.1 Add for each addl. floor up to 5th floor sqm Tk. 41.00
7.13.2 Add for each addl. floor for 6th floor to 9th floor sqm Tk. 61.00
7.13.3 Add for each addl. floor for 10th floor & above sqm Tk. 82.00
7.14 Extra rate of formwork for making ‘fair-faced’ surface of the concrete as per design, sqm Tk. 382.00
drawing and direction of Engineer-in-charge. (The formwork must be rigid enough
both in
and out of plane, to make the concrete surface true to the designed shape and size
by
using necessary MS
FORMWORK sheets of
(Wooden) forminimum
boundary 10wall,
BWG, angles
gate, of minimum
centry post etc. size 50 mm x
7.15 Centering and shuttering, including strutting, propping etc. and removal of form for:
7.15.1 Individual and combined footings sqm Tk. 399.00
7.15.2 Foundation beam sqm Tk. 381.00
7.15.3 Padestals, column, wall sqm Tk. 429.00
7.15.4 Tie beam & lintels sqm Tk. 417.00
7.15.5 T-beam, L-beam and rectangular beam sqm Tk. 414.00
7.15.6 Floor & roof slab sqm Tk. 456.00
7.15.7 Cornice, railing, drop wall, louver, fins etc. sqm Tk. 370.00
7.15.8 Sunshade, false ceiling sqm Tk. 399.00
7.15.9 Stair case slab and steps upto ground floor sqm Tk. 387.00
7.16 Supply and use of specified type chemical admixture delivered from an authorized
local
agent or manufacturer, complying with the ASTM C-494 requirements; conforming
the
current compliance of the admixture to specification requirements like physical
properties,
uniformity and equivalence in composition etc.; performance (water content, fresh
concrete setting time and compressive strength) requirements, delivered in sealed
watertight
containers confirming plainly marked product name & type under this specification,
net weight and /or volume, manufacturing and expiry date, non aggressiveness to
environment, aggregates and metals in concrete etc. and mixing the admixture in
non prestressed
cement concrete mixture in the field in accordance with manufacturers
recommendation and instruction; providing safety provisions in all respects etc. all
complete as per instruction and approved by the Engineer-in-charge. Dose (quantity
in
mililitres per 50 kg bag cement) and brand/origin/ manufacturer with respect to
7.16.1 Supply and use of water reducing chemical admixture in concrete, complying Liter Tk. 193.00
ASTM C-
494 Type - A of approved brand / origin / manufacturer and supplied by only
manufacturer's authorised dealer with certificate of origin. The admixture is to
reduce
quantity of mixing water required for normal workability and to maintain low water-
74
7.16.2 Supply and use of retarding chemical admixture in concrete, complying ASTM C- Liter Tk. 169.00
494
Type - B of approved brand/origin/manufacturer and supplied by only
manufacturer‟s
authorised dealer with certificate of origin. The admixture for retarding setting time
of
7.16.3 Supply and use of accelerating chemical admixture in concrete, complying ASTM C- Liter Tk. 151.00
494
Type - C of approved brand/origin/manufacturer and supplied by only
manufacturer's
authorised dealer with certificate of origin. An admixture that is to accelerate the
7.16.4 Supply and use of water-reducing and retarding chemical admixture in concrete, Liter Tk. 278.00
complying ASTM C-494 Type - D of approved brand/origin/manufacturer and
supplied by
only manufacturer's authorised dealer with certificate of origin. The admixture to
reduce
the quantity of mixing water required to produce concrete of given consistency, i.e.
low
7.16.5 Supply and use of water-reducing and accelerating chemical admixture in concrete, Liter Tk. 217.00
complying ASTM C-494 Type - E of approved brand/origin/manufacturer and
supplied by
only manufacturer's authorised dealer with certificate of origin. The admixture to
reduce
the quantity of mixing water required to produce concrete of given consistency, i.e.
low
7.16.6 Supply and use of water-reducing high range chemical admixture in concrete, Liter Tk. 290.00
complying ASTM C-494 Type - F of approved brand/origin/manufacturer and
supplied by
only manufacturer's authorised dealer with certificate of origin. The admixture
required to
produce concrete of consistency by 12% or greater (flowing concrete) and for higher
strength of concrete.
7.16.7 Supply and use of water-reducing high range and retarding chemical admixture in Liter Tk. 205.00
concrete, complying ASTM C-494 Type - G of approved brand/origin/manufacturer
and
supplied by only manufacturer's authorised dealer with certificate of origin. The
admixture
required to produce concrete of consistency by 12% or greater (flowing concrete)
and for
higher strength of concrete and intend to retard setting time of concrete.
75
7.17 Supply and use of best quality pliable, cold applied pre-formed self adhesive
rubberized/ bituminous water proofing membrane of approved brand / origin /
manufacturer from an authorized local agent or manufacturer having minimum
thickness
1.5 mm, lined with 2 ply cross laminated high density polyethylene film
performances and
properties all conforming to ASTM standards and laying, placing, fixing on made
up firm
and dry surfaces free from hollows, sharp protrusions, contaminates etc. laid over-
lap by
at least 75 mm along the edges and 125 mm at ends ensuring good initial bond with
the
surfaces all complete under the strict accordance with the manufacturer
recommendations
and instructions providing all safety provisions in all respects and accepted by the
Engineer. (supplied by only manufacturer's authorised dealer with certificate of
origin)
under following specification: Backing(HDPE) thickness minimum 0.10mm
Membrane thickness minimum 1.40mm
Total thickness minimum 1.50mm
Cold flexibility greater than (-)200C: ASTM D146
Pliability: "No crack" tested in ASTM D146
Tensile strength (film only) min 3.50 MPa( 35000 kN/m2) testing in ASTM D882
Tensile strength (composite) at least 2.40 MPa or N/mm2
7.17.1 Elongation (composite)
Water-proofing membrane minon300%
external surface of primed vertical or inclined wall sqm Tk. 999.00
/on
plastered and primed back-wall and concrete cast against membrane. (Excluding
cost of
back fill/brick wall on back/plaster when membrane laid on back-wall and concrete
cast
7.17.2 Water-proofing membrane on made up surface below the floor or below the sqm Tk. 871.00
horizontal
surfaces with temporary protective cover using polysterene/38 mm thick sand-
cement
mortar in 4:1 /or by equally effective alternative. (Rate is excluding the cost of
7.17.3 Water-proofing membrane on the floor or on the horizontal surfaces with permanent Tk. 908.00
protective cover & wearing coarse. (Rate is excluding the cost of protective cover
and
7.18 Supply of polymer based curing compound as per ASTM C 309 or BS 7542-1992 sqm Tk. 156.00
standard and apply by stirring & spraying with motorized sprayers over the surface
of fresh
concrete free from surface water and avoiding bleeding of concrete maintaining the
spray
nozzle approximately 450 mm away from the concrete surface with passed back and
forth
to ensure complete coverage confirming the pump pressure for fine spray and
keeping the
concrete surface undisturbed until it has sufficient strength to bear surface loads
[The
suitability of motorized sprayer should be ensured by an application trial] ensuring
76
7.19 Supply of epoxy bonding agent following ASTM C881 / C881M - 14 or any sqm Tk. 978.00
international
acceptable standard and apply over the old concrete surface after making free of
standing
water, removal of dust, laitance, grease, curing compounds, impregnations, waxes
and
any other contaminants to achieve optimum bonding in between fresh and old
7.20.0 Supply of best quality salt guard coating on concrete surface following ASTM B117 sqm Tk. 36.00
delivered from authorized local agent of the manufacturer in a sealed container and
apply
by a firm experienced in applying salt guard coating or workers trained and
approved by
manufacturer to wall and ceiling in 2 coats elapsing specified time for drying/
recoating
including cleaning and sand papering making the surface free from loose and
efflorescence, flaky materials, dirt, grease, wax, polish, scraping all chalked and
scaled
DIVISION 08 : M.S. FABRICATION ANDCONSTRUCTION JOINT IN RCC
WORKS
8.1 Supplying, fabrication and fixing to detail as per design : ribbed or deformed bar
reinforcement for Reinforced cement concrete, produced and marked in accordance
with
BDS ISO 6935 - 2: 2006 (or standard subsequentley released from BSTI) including
straightening and cleaning rust, if any, bending and binding in position with supply
of G.I.
8.1.1 wires, necessary
Grade laboratory
300 (RB 300 tests complying
/RB 300W: (excluding BDS
splices
ISOor 6935-2:2006)
laps) etc. complete
ribbedinorall Per kg Tk. 79.00
deformed
bar produced and marked according to Bangladesh sandard, with minimum yield
strength,
fy (ReH)= 300 MPa but fy not exceeding 330 MPa and whatever is the yield
8.1.2 strength
Grade 400 (RB 400 /RB 400W: complying BDS ISO 6935-2:2006) ribbed or Per kg Tk. 82.00
deformed
bar produced and marked according to Bangladesh standard, with minimum yield
strength,
fy (ReH)= 400 MPa but fy not exceeding 450 MPa and whatever is the yield
strength
within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength
8.2 Extra rate for M.S. Fabrication work in additional floor shall be incorporated in the
estimate
8.2.1 Add for each addl. floor up to 5th floor Per kg Tk. 0.48
8.2.2 Add for each addl. floor from 6th floor to 9th floor Per kg Tk. 0.97
8.2.3 Add for each addl. floor for 10th floor and above Per kg Tk. 1.45
8.3 Mild steel, grade 250 with minimum fy = 250 MPa, work in roof truss: supplying Per kg Tk. 138.00
and
fabrication of mild steel sections as per design, hoisting, fitting and fixing in
position with
bolt and nuts or rivets or welds and providing two coats of anti-corrosive paint over
a prime
coat of red oxide paint etc. complete and accepted by the Engineer-incharge.(
77
8.4 Supplying fan hook 300-grade (RB 300) of 16 mm diameter M.S. rod (one meter each Tk. 113.00
straight
length) having rounded hook at the middle of bar in proper size so as to be
concealed
within fan cup including fabrication, fitting and fixing in all floor accepted by the
8.5 Engineerin-
Installtation of water stopper at movable and immovable RCC green joints as per
following specification
8.5.1 Supplying, fitting and fixing ribbed PVC water stopper with non centre bulb of meter Tk. 1,017.00
width
approx. 250 mm and approx 9 mm thick for immovable (non working) RCC joints,
having
minimum tensile strength of 8.27 MPa (approx. 1200 psi) min ultimate elongation
350%,
8.5.2 Supplying, fitting and fixing ribbed PVC water stopper with centre bulb of width meter Tk. 1,017.00
approx.
250 mm and approx 9 mm thick for immovable (non working) RCC joints, having
minimum
tensile of strength 8.27 MPa (approx. 1200 psi) minimum ultimate elongation
350%,
approximate hardness 50, minimum tear resistance 0.0175 kN/mm (100 lbs/inch) at
RCC
construction green joints in basements, approved and in consultation with design
8.6 Supplying, fitting and fixing 250 mm wide 16 SWG aluminium sheet water stopper meter Tk. 331.00
in
RCC construction joint holding in position and keeping the water stopper in true
horizontal
8.7 Providing bearing joints fixed or free with 250 mm x 375 mm x 10 mm M.S. (Grade meter Tk. 2,298.00
- A36)
shoe plate fitted in the truss angles with 16 mm diameter M.S. rod counter sunk
rivets,
welded and anchored to 250 x 375 x 10 mm. M.S shoe plate by two Nos. 19 mm dia
9.1 Boring/drilling by wash or percussion method for cast in situ pile up to the required
depth and diameter with minimum 6 m long temporary steel casing, true to vertical,
providing bentonite slurry and maintaining water level in the hole, washing the hole for at
least 30 minutes, cleaning the bore hole and making the bore hole ready for placing steel
cage and concreting including hire charge of rig set with winch machine, tripod stand,
tremie pipe, cost of fuel, lubricant, mobilization, demobilization, maintenance, spares,
stand-byes, insurance coverage, water, electricity and other charges all compete,
approved and accepted by the Engineer-in-charge. Before commencing boring operation,
contractor shall submit the method statement of cast-in-situ pile work including sequence
of boring and casting, disposal of spoils, test result of materials to the Engineer-in-charge
for approval. However, Engineer‟s approval shall not relieve the contractor of his
responsibilities and obligations under contract
9.1.1 400 mm dia meter Tk. 502.00
78
9.2 Auger Boring/ Rotary Drilling for cast in situ pile up to the required depth and diameter
with minimum 6 m long temporary steel casing, true to vertical, providing bentonite slurry
and maintaining water level in the hole, washing the hole for at least 30 minutes, cleaning
the bore-hole and making the bore- hole ready for placing steel cage and concreting
including hire charge of rig set, trimie pipe, cost of fuel, lubricant, mobilization,
demobilization, maintenance, spares, stand-byes, insurance coverage, bentonite, water,
electricity and other charges all compete approved and accepted by the Engineer-incharge.
Before commencing boring operation, contractor shall submit the method
statement of cast-in-situ pile work including sequence of boring and casting, disposal of
spoils, test result of materials to the Engineer-in-charge for approval. However, Engineer‟s
9.2.1 600 mm dia meter Tk. 3,388.00
9.3 Removing of spoils / mud accumulated during boring for cast in situ pile by wash boring cum Tk. 557.00
from working site to a safe distance by contractor‟s own arrangement i.e. with container
set in truck or on cart including loading, unloading everything complete as per standard
practice and accepted by the Engineer-in-charge. (Quantity should be given three times of
solid volume of boring)
9.4 Cast in situ pile with reinforced cement concrete works of high slump by adding high cum Tk. 13,463.00
range water reducing admixture (ASTM C494 Type A or F) with minimum cement content
relates to mix ratio 1 : 1.5 : 3 having minimum f'cr = 26 Mpa, and satisfying a specified
compressive strength f‟c = 21 Mpa at 28 days on standard cylinders as per standard
practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM -
1,52.5
N / ASTM-C 150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips conforming to ASTM
C-33, including breaking chips, screening through proper sieves, making, placing re-bar
cage in position, placing and removing tri-pod as per requirement, pouring the concrete in
bore-hole with the help of a tremie pipe, maintaining the tremie pipe immersed in concrete
by at least 1 meter throughout the period of concreting, maintaining required slump, etc.
mixing the aggregates with standard mixer machine with hopper, casting in forms, all
complete including water, electricity, testing of materials and concrete etc and other
charges as per design, drawing etc all complete approved and accepted by the Engineerin-
charge. (Rate is excluding the cost of reinforcement and its fabrication, binding, welding,
placing and admixture (approx doses 150 to 250 ml per bag of cement which is to be fixed
9.5 upon consultation
Providing withpoint
and making design office))at contact point of the spiral binders at reasonable
welding point Tk. 3.00
intervals with the main reinforcements by electric arc welding for construction of cast in
situ bored pile carefully with highly oxidized electrodes, making the points prominent and
accepted by the Engineer-in-charge (Rate is inclusive of all materials labour, tools and
plants, electricity and all equipment).
79
9.7 Labour for breaking head of hardened cast in situ bored pile/pre-cast pile up to a cum Tk. 4,673.00
required length by any means but without damaging the rest and removing the dismantled
materials such as concrete to a safe distance including scraps and cleaning concrete from
steel/M.S. rods, straightening and bending of pile bars, preparation and making platform
where necessary, carrying, all sorts of handling, stacking the same properly after clearing,
leveling and dressing the situ and clearing the bed etc. complete in all respect and
accepted by the Engineer-in-charge. (Measurement will be given for the actual pile head
volume to be broken)
9.8 Conducting static load test as per ASTM D1143 or equivalent standard for the cast-insitu/
pre-cast pile providing required scaffolding, bracing, jacks, pressure test gauge,
loading unloading, Kentledge and other plants and equipment including staging,
mobilization, demobilization, hire charge, gunny bags, sand and filling sacs/gunny bags for
loading, record readings and preparation of results in standard forms and other incidental
charges as per standard practice and procedures including submission of load test report,
furnishing all graph and chart etc. complete in all respect approved and accepted by the
Engineer-in-charge (Minimum two cyclic loading; one at service load and another cycle at
double the service load then to continue loading till failure of the pile). Before commencing
load test, contractor shall submit method statement for conducting load test to the
Engineer-in-charge for approval. However, Engineer‟s approval shall not relieve the
Contractor of his responsibilities and obligations under Contract. Load test and report shall
be conducted under the supervision of a professional Geotechnical Engineer registered in
BPERB or Geotechnical firm registerd in PWD. Boring and pouring logs / driving logs of
piles and method statement shall be the part of load test report.
9.8.1 Mobilization & de-mobilization of testing equipment Per set Tk. 4,105.00
per site
9.8.3 For 50 tonne load 1 No. of test Per test Tk. 73,338.00
9.8.4 For 100 tonne load for 1 No. of test Per test Tk. 123,177.00
9.8.5 For 150 tonne load for 1 No. of test Per test Tk. 173,017.00
9.8.6 For 200 tonne load for 1 No. test Per test Tk. 224,571.00
9.8.7 For 250 tonne load for 1 No. test Per test Tk. 276,053.00
9.8.8 For 300 tonne load for 1 No. of test Per test Tk. 325,121.00
9.8.9 For 350 tonne load for 1 No. of test Per test Tk. 374,188.00
9.8.10 For 400 tonne load for 1 No. of test Per test Tk. 423,255.00
80
9.9.1 For intermediate loading from 50 tonne to 100 tonne for each additional tonne Per tonne Tk. 1,349.00
9.9.2 For intermediate loading from 100 tonne to 150 tonne for each additional tonne. Per tonne Tk. 1,193.00
9.9.3 For intermediate loading from 150 tonne to 200 tonne for each additional tonne. Per tonne Tk. 1,138.00
9.9.4 For intermediate loading from 200 tonne to 250 tonne for each additional tonne. Per tonne Tk. 1,114.00
9.9.5 For intermediate loading from 250 tonne to 300 tonne for each additional tonne. Per tonne Tk. 1,094.00
9.9.6 For intermediate loading from 300 tonne to 350 tonne for each additional tonne. Per tonne Tk. 1,077.00
9.9.7 For intermediate loading from 350 tonne to 400 tonne for each additional tonne. Per tonne Tk. 1,064.00
9.1 Pre-cast pile made in reinforced cement concrete with minimum cement content
relates to mix ratio 1:1.25:2.5 having minimum f'cr = 35 Mpa, and satisfying specified
compressive strength f‟c = 30 Mpa at 28 days on standard cylinders as per standard
practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM-I
(52.5
N) / ASTM-C 150 Type – I, best quality coarse sand (F.M.2.2), 20 mm down well graded
crushed stone chips conforming to ASTM C-33, mixing in standard mixture machine and
fed by standard measuring boxes, including all related works like screening through proper
sieves, cleaning and washing, centering and shuttering with M.S sheet, M.S angle, F.I bar,
nuts and bolts, champering edges if so, preparation of casting beds, laying polythene
there in, placing reinforcement cages in position, casting, compacting by vibrators and
tapered rods as where necessary, curing for 28 days etc. cost of water, electricity and
other charges, providing fitting and fixing pile shoe in position, tools, plants & equipments,
mobilization, demobilization, labour, test of materials and concrete etc. all complete as per
design, drawing and accepted by the Engineer-in-charge. (Rate is excluding the cost of
reinforcement and its fabrication, binding, welding and placing)
9.10.1 250 mm x 250 mm size pre-cast pile (1:1.25:2.5) with stone chips meter Tk. 965.00
9.10.2 300 mm x 300 mm size pre-cast pile (1:1.25:2.5) with stone chips meter Tk. 1,347.00
9.10.3 350 mm x 350 mm size pre-cast pile (1:1.25:2.5) with stone chips meter Tk. 1,777.00
9.10.4 400 mm x 400 mm size pre-cast pile (1:1.25:2.5) with stone chips meter Tk. 2,294.00
9.10.5 450 mm x 450 mm size pre-cast pile (1:1.25:2.5) with stone chips meter Tk. 2,866.00
9.11 Pre-cast pile shoe making & supplying pre-fabricated frustum of square cone having four each Tk. 2,725.00
sides and a toe made of 6 mm thick ASTM A36 complied MS steel plate jointed by line
welding, 4 nos 12 mm dia deformed MS bar jointed by line welding with MS plate along the
four edges of shoe aligning the corner main bar of the pile and 1 no 12 mm dia bar to fix
with and perpendicular to shoe toe plate aligning centre of pile, including cutting, shaping,
sizing of MS plate and bar, all complete as per design & drawing and accepted by the
Engineer-in-charge
9.12 Mobilization and demobilization of drop hammer type pre-cast pile driving rig. Per set Tk. 8,597.00
per site
81
9.14 Driving 300 mm x 300 mm size pre-cast pile with drop hammer type rig, and meter Tk. 531.00
maintaining driving log in prescibed format Before commencing driving operation,
contractor shall submit method statement for carrying out the driving operation including
sequence of driving to the Engineer-in-charge for approval. However, Engineer‟s approval
shall not relieve the contractor of his responsibilities and obligations under contract.
9.15 Driving 350 mm x 350 mm size pre-cast pile with drop hammer type rig, and meter Tk. 708.00
maintaining driving log in prescibed format. Before commencing driving operation,
contractor shall submit method statement for carrying out the driving operation including
sequence of driving to the Engineer-in-charge for approval. However, engineer‟s approval
shall not relieve the contractor of his responsibilities and obligations under contract.
9.16 Mobilization and demobilzation of automatic diesel hammer mounted complete rig set. Per set Tk. 181,117.00
per site
9.17 Driving 250 mm x 250 mm size pre-cast pile by rig fitted with automatic diesel operated meter Tk. 628.00
hammer. Before commencing driving operation by rig fitted with automatic diesel operated
hammer, Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer’s approval shall not
relieve the Contractor of his responsibilities and obligations under contract.
9.18 Driving 300 mm x 300 mm size pre-cast pile by rig fitted with automatic diesel operated meter Tk. 812.00
hammer. Before commencing driving operation by rig fitted with automatic diesel operated
hammer, Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer’s approval shall not
relieve the Contractor of his responsibilities and obligations under contract.
9.19 Driving 350 mm x 350 mm size pre-cast pile by rig fitted with automatic diesel operated meter Tk. 863.00
hammer. Before commencing driving operation by rig fitted with automatic diesel operated
hammer, Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer’s approval shall not
relieve the Contractor of his responsibilities and obligations under contract.
9.20.0 Driving 400 mm x 400 mm size pre-cast pile by rig fitted with automatic diesel operated meter Tk. 920.00
hammer. Before commencing driving operation by rig fitted with automatic diesel operated
hammer, Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer’s approval shall not
relieve the Contractor of his responsibilities and obligations under contract.
9.21 Driving 450 mm x 450 mm size pre-cast pile by rig fitted with automatic diesel operated meter Tk. 986.00
hammer. Before commencing driving operation by rig fitted with automatic diesel operated
hammer, Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer’s approval shall not
82
9.22.1 Casting of 180 mm x 180 mm x 7.6 m Pile with reinforced cement concrete (1:1.25:2.5) meter Tk. 506.00
with stone chips
9.22.2 Casting of 205 mm x 205 mm x 7.6 m Pile with reinforced cement concrete (1:1.25:2.5) meter Tk. 634.00
with stone chips
9.22.3 Driving of 180 mm x 180 mm x 7.6 m pre-cast pile meter Tk. 159.00
9.22.4 Driving of 205 mm x 205 mm x 7.6 m pre-cast pile meter Tk. 189.00
9.22.5 Supply of Cold-Drawn Wire Pre-stressed Concrete (CWPC) micro-pile which is made meter Tk. 1,003.00
by using cold drawn wire minimum cement content relates to mix ratio 1:1.5:3 cement
conforming to BDS EN-197-1-CEM-1, 52.5N (52.5MPa) / ASTM-C 150 type - 1, having
minimum f'cr = 35 MPa and satisfying specified compressive strength f'c= 30 MPa at 28
days best quality coarse sand (F.M. 2.2), 20 mm down well graded stone chips conforming
to ASTM C-33, mixing in standard mixture machine and fed by standard measuring boxes,
including cost of all kind of reinforcement BDS ISO 6935-2:2006 including strengthening
and cleaning rust if any bending and binding in position with supply of GI wires (24 BWG),
centering and shuttering with M.S. sheet, M.S. angle, F.I. bar, nuts and bolts, preparation
of bed, supplying & tensioning of cold drawn wire, laying polythene, placing of
reinforcement cage in position, casting, compacting by vibrator and tapered rods, curing at
least 28 days etc. including cost of water, electricity and other charges, proving pile shoe
making with 20 BWG plane sheet, as per design and drawing including an equipments
mobilization, demobilization champering edges if so including the cost of water electricity
and other charges all complete as per design, drawing and accepted by the Engineer-
incharge.
(Excluding the cost of carrying and driving of pile). Maximum length: Up to
7620mm (fixed size x-section: 180 mm x 180 mm)
83
9.23.1 Mobilization and demobilization to site and PIT on12 (twelve) piles or less upto 1st Tk. 24,149.00
12 pile
9.23.2 For PIT test of each additional pile after 12 (Twelve) pile tested at same site per pile Tk. 1,207.00
9.24 Pre-cast spliced pile jointing by supplying, fitting, fixing prefabricated square shaped two
steel caps made up by 6 mm thick ASTM A36 complied M.S plate, sides formed by bent in
channel shape to have only two line of joinery on faces, having min 50 mm dia hole on its
web; capping by min 12 mm thick ASTM A36 complied M.S plate shaping the edges in
45°, having min 40 mm dia hole at centre to pass 25 mm M.S bar 433 mm in length;
jointed at channels root by welding; caps fitted with 2 nos BDS ISO 6935-2009: B400
DWR complied d20 U-bar 1244mm in length by welding, equidistant from centre holes of
cap and shall have min 75 mm clear from pile faces; and finally, the system to be fitted in
correct alignments on pile head positions waiting for concreting; both the pile heads fitted
with the steel caps to be welded together through v-notches in field, while one of the
companion segment of piles drived in ground and other one placed over it maintaining true
verticality; all complete as per direction and stepwise approval leading to final approval of
Engineer-in- charge.
9.24.1 X-sec of pre cast pile segments :300 mm x 300 mm each Tk. 9,286.00
9.24.2 X-sec of pre cast pile segments :350 mm x 350 mm each Tk. 10,610.00
9.24.3 X-sec of pre cast pile segments :400 mm x 400 mm each Tk. 12,076.00
9.24.4 X-sec of pre cast pile segments :450 mm x 450 mm each Tk. 12,611.00
9.25.1 Mobilization and demobilzation of hydraulic static pile driver(Upto 500 metric ton
capacity)
9.25.2.1 Driving pre-cast pile of 300 mm x 300 mm X-section made with shoe/ without shoe by meter Tk. 808.00
Hydraulic static pile driver of approx. 500 tonne (metric ton) capacity; arranged with
necessary cranes, power source, maintaining driving log and record of pressure exerted
on piles driven in to desired RL or capacity level ; complete in all respect including
handling of piles, dressing & leveling of site, way making, surveying, layout setting etc
ended with the submission of pile driving report in three copies duly signed by
professional engineer and approved by the Engineer-in-charge.
84
9.25.2.3 Driving pre-cast pile of 400 mm x 400 mm X-section made with shoe/ without shoe by meter Tk. 943.00
hydraulic static pile driver of approx. 500 tonne (metric ton) capacity; arranged with
necessary cranes, power source, maintaining driving log and record of pressure exerted
on piles driven in to desired RL or capacity level ; complete in all respect including
handling of piles, dressing & leveling of site, way making, surveying, layout setting etc
ended with the submission of pile driving report in three copies duly signed by
professional engineer and approved by the Engineer-in-charge.
9.25.2.4 Driving pre-cast pile of 450 mm x 450 mm X-section made with shoe/ without shoe by meter Tk. 984.00
hydraulic static pile driver of approx. 500 tonne (metric ton) capacity; arranged with
necessary cranes, power source, maintaining driving log and record of pressure exerted
on piles driven in to desired RL or capacity level ; complete in all respect including
handling of piles, dressing & leveling of site, way making, surveying, layout setting etc
ended with the submission of pile driving report in three copies duly signed by
professional engineer and approved by the Engineer-in-charge.
DIVISION 10 : STRUCTURAL STEEL WORKS, SHEET ROOFING AND
SAFETY CANOPY
10.1 Supply and fixing of galvanized anchor bolts of variable dia for rigid frame conforming to kg Tk. 180.00
ASTM F1554 Grade 55, Galvanized to A153, Class C or equivalent with minimum yield
strength of 380 MPa, manual of steel construction by American Institute of Steel
Construction (AISC) etc. including the cost of washer & bolts, material testing etc. all
complete as per drawing, specification and direction of the Engineer-in-charge.
10.2 Supply, fabrication and installation of built-up sections i.e. columns, beams, rafters, kg Tk. 135.00
bracings etc. from steel plates conforming to ASTM A572, with a minimum yield strength
of 345 MPa, including the cost of testing of plates, applicaton of red/grey-oxide primer etc.
all complete as per drawing, specification and direction of Engineer-in-charge.
10.3 Supply, fabrication and installation of built-up sections i.e. columns, beams, rafters, kg Tk. 129.00
bracings etc from steel plates conforming to ASTM A36, with a minimum yield strength of
250 MPa, including the cost of testing of plates, application of red/grey-oxide primer etc. all
complete as per drawing, specification and direction of Engineer-in-charge.
10.4 Supply, fabrication and installation of hot-rolled sections (W, H, I-shape, Channel, angle, kg Tk. 132.00
tube etc.) for columns, beams, rafters, bracings etc. conforming to ASTM A36, with a
minimum yield strength of 250 MPa, including the cost of testing of plates, application of
red/grey-oxide primer etc. all complete as per drawing, specification and direction of
Engineer-in-charge.
10.5 Supply and fixing of connection bolts of variable diameter with nut and washer according kg Tk. 314.00
to "ASTM A325 Type 1 or equivalent” with Fu =720 Mpa, including the cost of testing of
bolts, all complete as per drawing, specification and direction of Engineer-In-Charge.
10.6 Supply and fixing of connection bolts of variable diameter with nut and washer according kg Tk. 259.00
to "ASTM A307 Type A or equivalent” with Fu =414 Mpa, including the cost of testing of
bolts, all complete as per drawing, specification and direction of Engineer-In-Charge.
10.7 Supply and installation of GI purlin & girt of any size conforming to "ASTM A653" grade kg Tk. 137.00
45, with a minimum yield strength of 310 MPa, including the cost of testing of materials, all
complete as per drawing, specification and direction of Engineer-in-charge.
85
10.11 Supply and installation of 0.70 mm thick galvanized decking panel according to ASTM kg Tk. 181.00
A653, with minimum yield strength of 345 MPa, including all necessry accessories
(sheeting screws with washers, sealants etc.), testing of materials etc. all complete as per
10.12 drawing,and
Supply specification
installationand direction
of 0.47 of Engineer-in-charge.
mm thick zinc alum color coated profile sheet for roof, kg Tk. 211.00
wall, caping, flashing, trimming, gutter etc. conforming to ASTM A792, Grade: 80, AZ150
10.13 gm/m2, including the cost of necessary accessories
Supply and installation of 0.457 mm thick corrugated (sheeting screws
galvanized ironwith washers, silicon
sheet sqm Tk. 555.00
(Bangladesh made) having min weight 63-65 kg per bundle (2'-6" width, 70 – 72 rft long)
10.14 fitted
Supply and
andfixed on M.S.ofsections
installation 2.0 mmwith 'J'fiber
thick hookglass
or wooden purlin with screws,
sheet (transparent limpet
sheet) for roof, wall sqm Tk. 1,315.00
etc. on M.S. purlin, angle etc. with 'J' hook or screws with washer and putty, all complete
10.15 as per drawing,
Supply specification
and installation and direction
of double ofinsulation
bubble foil Engineer-in-charge.
at wall and roof of nominal sqm Tk. 283.00
thickness of 8 mm conforming to Class A in accordance with the ASTM-E84-09 fire test
10.16 standard,
Premium including the cost paint
Synthetic Enamel of lapping, costape,
of approved adhesive
best qualityand
andnecessary accessories,
colour delivered fromall kg Tk. 9.00
authorized local agent of the manufacturer(Berger robbialac supergloss synthetic
10.17 enamel/Elite lucky seven/
Supply and application of Asian apcolipe
corrosion premium
protection paintpaint orsurface
to the equivalent brand)
of the in a sealed
structural steel kg Tk. 26.00
members conforming to SA 2.5; Steel members to be shot blasted inside the enclosed
10.18 shot blasting
Supply chamber,
and pouring final coat paint
of non-shrink groutmust be applied
to steel columnon site conforming
bases after installation, including
to ASTM C cum Tk. 145,213.00
109 having compressive strength not less than 45 MPa, including the cost of shutter and
10.19 necessary accessories,
0.27 mm thick all complete
galvanized iron plainassheet
per drawing, specification
ridging with 300 mm lapandon
direction of fitted
either side
and fixed with galvanized bolts and nuts etc. all complete and accepted by the Engineerin-
10.19.1 charge.
Galvanized meter Tk. 422.00
10.20.0 1.5 mm thick plain fiber glass sheet ridging with 300 mm lap on either side fitted and meter Tk. 769.00
fixed with galvanized bolts and nuts etc. all complete and accepted by the Engineer-
10.21 incharge.
Saftey Canopy: Supplying temporary safety canopy around construction work place sqm Tk. 1,923.00
where public safety is likely to be endangered due to construction activities; which shall be
10.22 made
Safteyof truss
net: system of
Supplying steel sections
temporary safety(main frame) cloth)
net (hessian at 1800 mm c/c
around with purlins
construction @ 750
work place sqm Tk. 42.00
(along the height of the building) where public safety is likely to be endangered due to
construction
DIVISIONactivities;
11 : which
WOOD shall be supported
WORKS using scaffolding
IN DOOR AND WINDOWaround theFRAME,
building for
ROOF TRUSS AND RAILINGS
11.1 Supplying and making door and window frames (Chowkat) for all floors with matured
natural seasoned wood of required size including painting two coats of coal tar to the
surface in contact with wall, fitting and fixing in position etc. complete and accepted by the
Engineer in- charge.
(All sizes of wood are finished).
11.2 Supplying, fitting and fixing M.S. flat bar clamp of 225 mm x 38 mm x 6 mm size having each Tk. 97.00
bifurcated ends to door and window frames with necessary screws including cutting
grooves in chowkat if necessary and encasing inside the wall with cement concrete (1:2:4)
etc, all complete and accepted by the Engineer-in-charge.
11.3 Supplying, fitting and fixing M.S. flat bar clamp 150 x 38 x 6 mm size having bifurcated each Tk. 97.00
ends to door and window frames with rowel plug, necessary screws etc. including cutting
groove in Chowkat if necessary etc. complete in all respect accepted by the Engineer-in-
charge.
11.4 Supplying, fitting and fixing double leaf door frame for all floors with 38 x 38 x 6 mm meter Tk. 611.00
M.S. angle fitted with 250 mm long 6 Nos. of iron clamps of same size (with one end
bifurcated) with the vertical members of the frame, fixing the frame in wall with cement
concrete (1:2:4), mending good the damages, fixing 6 Nos. of 100 mm size iron hinges with
the vertical members of the frame all complete including cutting, sizing, welding,
fabricating, carrying from work-shop to site and local carriage, curing etc. complete as per
11.5 Supplying, fitting and fixing single leaf door frame for all floors with 38 x 38 x 6 mm M.S. meter Tk. 597.00
angle, fixing 125 mm long 6 Nos. of iron clamps of same size (with one end bifurcated)
with the vertical members of the frame, fixing the frame in wall with cement concrete
(1:2:4), mending good the damages, fixing 4 Nos. of 100 mm size iron hinges with the
vertical members of the frame all complete including cutting, sizing, welding, fabricating,
carriage from workshop to site including local carriage, curing etc. as per plan and drawing
11.6 Supplying matured seasoned wood and making roof truss of any size with wall plates
as per design including supplying, fabricating and hoisting, scaffolding, fitting and fixing in
position with bolts, nuts, painting two coats of coal tar etc. all complete and accepted by
the Engineer-in–charge. (All sizes of wood are finished).
11.7 Supplying and making hand rail for stair case with matured seasoned wood including
necessary moulding with proper corner, finishing as per design, fitting and fixing in position
in all floors etc. all complete and accepted by the Engineer-in-charge.
12.3 Supplying, fitting and fixing 38 mm thick finished well matured seasoned (minimum 250 sqm Tk. 15,393.00
mm wide plank) wooden ornamental special design (equivalent hatil) (both sides) single
panel flush door shutter with top and middle rail 150 mm x 38 mm bottom rail 225 mm x
38
mm and style 125 mm x 38 mm, having vertical panels 175 mm x 38 mm including
minimum 12 mm lap to each panel providing 4 nos, best quality 100 mm long brass
hinges, 12 mm dia best quality 200 mm & 250 mm long brass socket and tower bolts, 1
(one) no best quality hasp bolt, 2 (two) nos heavy type best quality brass handle, hinges
cleats, buffer blocks including supply of necessary nails and screws, making design by
machine, finished etc. all complete in all floors and accepted by the Engineer-in-charge
(Chittagong teak wood). (All sizes of wood are finished)
12.4 Supplying, fitting and fixing 38 mm thick well matured seasoned (minimum 250 mm wide
plank) wooden double leaf panel door shutters. Top rail and styles of sections 100 mm
x 38 mm, lock rail 125 mm x 38 mm and bottom rail 225 mm x 38 mm, paneling 38 mm
thick both sides raised, provided with best quality 8 nos 100 mm long iron hinges, 2 (two)
nos best quality 12 mm dia 250 mm and 200 mm long iron tower and socket bolts, 2 (two)
nos heavy type nickel plated handle, 1 no hasp-bolt, hinged cleats, buffer blocks and
finished by sand papering, necessary screws etc. all complete in all floors and accepted
by the Engineer-in-charge. (All sizes of wood are finished)
88
12.5 Supplying, fitting and fixing 38 mm thick well matured seasoned (minimum 250 mm wide
plank) wooden double leaf panel door shutters. Top rail and styles of sections 100 mm
x 38 mm. lock rail 125 mm x 38 mm and bottom rail 225 mm x 38 mm. paneling 25 mm
thick one side raised, provided with best quality 6 nos. 100 mm long iron hinges, 2 (two)
nos best quality 12 mm dia 250 mm and 200 mm long iron tower and socket bolts, 1 (one)
no best quality hasp bolt, 2 (two) nos heavy type nickel plated handles, 1 (one) no best
quality hasp bolt, hinged cleats, buffer blocks and finished by sand papering, necessary
screws etc. all complete in all floors and accepted by the Engineer-in-charge.(All sizes of
wood are finished)
12.13 Supplying, fitting and fixing 38 mm thick well matured seasoned (minimum 250 mm wide
plank) wooden window shutter one third glazed and two third raised paneling on
both sides for all floors having horizontal and vertical sections of 87 mm x 38 mm and sash
bars 38 mm x 38 mm fitted with 3 mm glass panes with putty and nails and provided with
best quality 4 nos 75 mm long iron hinges. 2 (two) nos. best quality 12 mm dia 250 mm
and 150 mm long iron tower and socket bolts, nickel plated handles, 3 mm glass, 02 nos
12.13.1 Kathal sqm Tk. 8,582.00
12.14 Seasoning of timber in a recognized mechanical timber seasoning plant up to a moisture cum Tk. 9,125.00
content of 12% - 16% by weight as measured by a electric moisture meter or any other
moisture measuring device etc. complete in all respect including loading, unloading,
carriage at both ends accepted by the Engineer -in- charge.
12.15.1 Supplying, fitting and fixing steel glazed window shutter for all floors with frames as per sqm Tk. 5,397.00
design having 25 mm x 25 mm x 5 mm angle section for Chowkat and shutters and 50 mm
x 25 mm x 5 mm T- section used for vertical member and 25 mm x 5 mm F.I. bar for
making box (combining with angle) and 25 mm x 19 mm x 5 mm T-section used for glass
divider etc. including all charges for welding, riveting etc. including cost of supplying all
essential fittings like iron hinges, plate handle, pin-stopper, adjustable cleat and clamps
including supplying, fitting, fixing 3 mm glass panes by pucca putty, for fittig and fixing the
frame, making necessary holes in brick walls and R.C.C works and fitting with C.C. (1:2:4)
12.15.2 Supplying, fitting and fixing M.S. door shutter made with 38 mm x 38 mm x 6 mm angle sqm Tk. 5,870.00
outer frame, inner member 25 mm x 6 mm F.I. bar, cladding with 16 BWG M.S. sheet, 04
nos. 75 mm long hinge, 02 nos locking arrangement with 50 mm x 50 mm x 6 mm M.S.
angle chowkat including all charges for welding, riveting etc. including cost of supplying all
essential fittings like iron hinges, socket bolts, clamps, for fittig and fixing the frame,
making necessary holes in brick walls and R.C.C works and fitting with C.C. (1:2:4) and
mending good the damages including all cost of carriage, workshop charges, electricity,
and labour for fittings, fixing, curing etc. all complete and accepted by the Engineer-
incharge.
12.16 (Rate is excluding
Supplying, the fixing
fitting and costs of painting).
steel glazed window shutter for all floors with frames as per
design having 19 mm x 19 mm x 19 mm x 3 mm Z-section in frame and 19 mm x 3 mm
12.16.1 F.I.
With barprovision
for making
forT-section
fan-lightfor
byhorizontal
providingdividers of shutters
necessary and materials,
additional 25 mm x 303mm F.I. bar
nos sqm Tk. 3,557.00
adjustable 300 mm long iron cleats and 6 nos 50 mm long iron pin hinges (total wt of
grill
without glass panes is min 28.13 kg for 15 sft)
91
12.21 Extra cost for using brass/ SS fittings in place of iron fittings in doors & windows for all
floors (super quality local).
12.21.1 Brass fittings of door sqm Tk. 638.00
12.21.2 SS fittings of door sqm Tk. 329.00
12.21.3 Brass fittings of windows sqm Tk. 842.00
12.21.4 SS fittings of windows sqm Tk. 459.00
12.22 Supplying, fitting and fixing hydraulic door closer (big size) of approved quality each Tk. 1,808.00
including all necessary tools and accessories etc. all complete and accepted by the
Engineer-in-charge
12.23.1 Supplying, fitting and fixing mortice door lock of approved quality including all each Tk. 1,023.00
necessary tools and accessories etc. all complete approved and accepted by the
12.23.2 Engineer-in-charge.
Supplying, fitting and fixing rim/round door lock of approved quality including all each Tk. 963.00
necessary tools and accessories etc. all complete and accepted by the Engineer-incharge.
12.24 Supplying, fitting and fixing of best quality magnetic door shock absorber of approved each Tk. 420.00
quality including all necessary tools and accessories etc. all complete and accepted by the
Engineer-in-charge.
12.25 Supplying, fitting and fixing best quality heavy type 19 mm dia and 300 mm long brass each Tk. 525.00
hasp bolt including cutting grooves in door shutter and frames, screws etc. all complete
approved and accepted by the Engineer-in-charge.
12.26 Supplying, fitting and fixing approved best quality foreign made stainless steel/brass each Tk. 595.00
door viewer/eye viewer from 12 mm to 20 mm diameter with adjustable thickness
suitable for fitting from 37 mm to 50 mm thick door shutter including all necessary work as
per direction and accepted by the Engineer-in-charge.
13.7 Supplying, fitting and fixing veranda grill made of 10 mm dia M.S. rods provided @ 100 sqm Tk. 2,087.00
mm c/c in any position both ways as per design with outside frame 25 mm x 25 mm x 6
13.8 mm M.S. angle
Supplying, fittingincluding fabricating,
and fixing verandah welding in each
grill made of 10point,
mm diapainting 2 coats
M.S. rod of synthetic
provided @ 75 sqm Tk. 2,357.00
mm c/c in any position both ways as per design with outside frame of 25 mm x 25 mm x 6
mm M.S. angle including fabricating, welding in each point , painting 2 coats of synthetic
enamel paint over a coat of anti-corrosive priming including cost of electricity, tools and
14.14 Supplying, fitting and fixing in Aluminium door frames, windows, partitions and curtain
wall
distortion free glass of approved quality and shade including cost of fitting fixing all
necessary accessories etc. complete in all respect as per drawing and accepted by the
14.14.1.1 5 mm thick clear glass sqm Tk. 1,133.00
14.16 Supplying, fitting and fixing of aluminium curtain wall with aluminium top hung/casement sqm Tk. 9,240.00
windows as per the US Architectural Aluminium Manufacturer's Association (AAMA)
standard specification and BDS 1879:2014 having 100 mm , 50mm, 2mm curtain wall
submullim
outer and inner frame, 15 mm thick casement outer frame (size 38.86 mm 36.6
mm), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm,) 1.2 mm thick shutter
glass strips, all aluminium member will be powder coated with coat not less than 1.5
micron in thickness including all accessories 4 bar hinge casement handle, 50 mm x 50
mm x 6 mm aluminium angle, steel rowel bolt, screws , rivets norton tape masking tape,
structural sealant, gum bracket rod etc. all complete in all respect as per drawing and
direction of the Engineer-in-charge.
14.17 Supplying, fitting and fixing of aluminium curtain wall and aluminium top hung/casement sqm Tk. 7,832.00
windows ad per the US Architectural Aluminium Manufacturer's Association (AAMA)
standard specification and BDS 1879:2014 having 50 mm , 50 mm, 2 mm curtain wall
submullim
outer and inner frame, 15 mm thick casement outer frame (size 38.86 mm 36.6
mm), 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2 mm thick shutter
glass strips, all aluminium member will be powder coated with coat not less than 1.5
micron in thickness including all accessories 4 bar hinge casement handle, 50 mm x 50
mm x 6 mm aluminium angle, steel rowel bolt, screws , rivets norton tape masking tape,
structural sealant, gum bracket rod etc. all complete in all respect as per drawing and
direction of the Engineer-in-charge.
14.18 Supplying, fitting and fixing of aluminium curtain wall along with 10 mm thick clear sqm Tk. 10,303.00
tempered glass as per the US Architectural aluminium Manufacturer's Association
(AAMA) Standard Specification and BDS 1879:2014 having 115 mm , 64 mm, 3 mm
curtain wall sub-mullim outer and inner frame, 15 mm thick casement outer frame (size
38.86 mm 36.6mm), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm,) 1.2 mm
thick shutter glass strips, all aluminium member will be powder coated with coat not less
than 1.5 micron in thickness including all accessories 4 bar hinge casement handle, 50 m
x 50mm x 6m aluminium angle, steel rowel bolt, screws , rivets norton tape masking tape,
structural sealant, gum bracket rod etc. all complete in all respect as per drawing and
direction of the Engineer-in-charge.
14.19 Supplying, fitting and fixing of 12 mm thick clear tempered glass wall upto 3.0 m height sqm Tk. 19,790.00
with vertical fin glass support of same thickness and support shall be at least 1.2 m c/c
fixed properly with glass by silicon glue with supply and fittings of all required accessories
such as SS u channel, nut bolts, aluminium angle, steel rowel bolt, screws , rivets norton
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect as
per drawing and direction of the Engineer-in- charge
14.2 Supplying, fitting and fixing of 12 mm thick tempered glass wall from 3.0 m to 6.0 m sqm Tk. 19,782.00
height with spider point fixing joint and vertical fin glass support of same thickness,
support shall be at least 1.2 m c/c fixed properly with main glass by silicon glue with supply
and fittings of all required accessories such as SS u chennel, nut bolts, aluminium angle,
steel rowel bolt, screws , rivets norton tape masking tape, structural sealant, gum bracket
rod etc. all complete in all respect as per drawing and direction of the Engineer-in-charge.
98
15.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to wall sqm Tk. 243.00
both inner-and outer surface, finishing the corner and edges including washing of sand
cleaning the surface, scaffolding and curing at least for 7 days, cost of water, electricity and
other charges etc. all complete in all respect as per drawing and accepted by the Engineer-in-
charge. (Cement: CEM-II/A-M). Ground floor.
15.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to sqm Tk. 280.00
plinth wall (1:4) with cement up to 150 mm below ground level with neat cement finishing
including washing of sand, finishing the edges and corners and curing at least for 7 days,
cost of water, electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer-in-charge. (Cement: CEM-II/A-M). Ground floor.
15.3 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to sqm Tk. 295.00
dado (1:4) with cement up to 150 mm below ground level with neat cement finishing
including washing of sand, finishing the edges and corners and curing at least for 7 days,
cost of water, electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer-in-charge. (Cement: CEM-II/A-M). Ground floor.
15.4 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:6) having with fresh cement to sqm Tk. 228.00
wall both inner-and outer surface, finishing the corner and edges including washing of sand
cleaning the surface, scaffolding and curing at least for 7 days, cost of water, electricity and
other charges etc. all complete in all respect as per drawing and accepted by the Engineer-in-
charge.
15.5 Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to ceiling sqm Tk. 225.00
R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings, drop wall,
louvers, fins and finishing the corners and edges including washing of sand cleaning the
surface, scaffolding and curing at least for 7 days, cost of water, electricity and other charges
15.6 etc. all complete
Minimum 6 mm in all respect
thick cementassand
per drawing andplaster
(F.M. 1.2) accepted by with
(1:3) the Engineer-in-charge.
fresh cement to ceiling sqm Tk. 222.00
R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings, drop wall,
louvers, fins and finishing the corners and edges including washing of sand cleaning the
surface, scaffolding and curing at least for 7 days, cost of water, electricity and other charges
etc. all complete in all respect as per drawing and accepted by the Engineer-in-charge.
(Cement: CEM-II/A-M) Ground floor.
15.7 Flush pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with cement sqm Tk. 141.00
including raking out the joints, and necessary scaffolding curing at least for 7 days, cost of
water, electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer-in-charge.
(Cement: CEM-II/A-M). Ground floor.
15.8 Rule pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with fresh cement sqm Tk. 179.00
and raking out the joints, scaffolding, curing at least for 7 days, cost of water, electricity and
other charges etc. all complete in all respect as per drawing and accepted by the Engineer-in-
charge.
15.9 (Cement:
Raised orCEM-II/A-M).
tack pointing Ground
work tofloor.
brick wall with cement sand (F.M. 1.2) mortar (1:2) sqm Tk. 441.00
with fresh cement minimum 12 x 20 mm in size including raking out the joints and
necessary scaffolding, curing at least for 7 days, cleaning each and every brick, cutting the
bricks with pumic stone where necessary etc. all complete in all floors, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and accepted by
the Engineer-in-charge. (Cement: CEM-II/A-M) Ground floor.
99
15.16.1 Add for each additional floor up to 5th floor. sqm Tk. 14.00
15.16.2 Add for each additional floor from 6th floor to 9th floor sqm Tk. 21.00
15.16.3 Add for each additional floor 10th floor and above sqm Tk. 28.00
15.17 Pre-cast ventilators of minimum 25 mm thick of any design with cement sand (F.M.1.2) sqm Tk. 2,103.00
mortar (1:4) fitted and fixed in position, finished with cement sand (F.M. 1.2) plaster (1:6)
including necessary scaffolding and curing, in all floors accepted by the Engineer-in-charge.
(Cement: CEM-II/A-M)
15.18 75 x 75 mm cornice of brick masonry in cement sand (F.M. 1.2) mortar (1:6) having rm Tk. 216.00
minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:6) including scaffolding and
curing at least for 7 days in all floors accepted by the Engineer-in-charge.
(Cement: CEM-II/A-M)
15.16 Supplying, fitting, fixing of broken and sharp glass 19 mm to 32 mm height, av. 19 mm sqm Tk. 223.00
width placed at a distance approximately 25 mm center to center spacing, embedding the
same to 12 mm to 19 mm thick cement plaster with neat cement finishing including
necessary scaffolding approved and accepted by the Engineer-in-charge.
(Cement: CEM-II/A-M)
16.2.1 Interior standard acrylic emulsion paint (plastic or matt finish) of approved best sqm Tk. 234.00
quality and colour delivered from authorized local agent of the manufacturer (Berger
robbialac plastic emulsion/Asian apcolite plastic emulsion or equivalent brand) in a sealed
container; applying to interior wall and ceiling with surface preparation including cleaning
drying, making free from dirt, grease, wax, removing all chalked and scaled materials,
fungus, mending good the surface defects using sand paper and necessary scaffolding;
applying 1 coat of interior sealer of specified brand on prepared surface; then applying 1
coat of interior putty of specified brand for levelling, spot filling, crack filling and cutting by
sand paper/zero water paper; finally applying 2 coats of interior emulsion paint spreading
by brush/roller/spray & necessary scaffolding etc. upto desired finishing, elapsing specified
time for drying or recoating; all complete in all floors and accepted by the Engineer-
incharge.
16.2.2 Interior premium acrylic emulsion painting (silky finish) of approved best quality and sqm Tk. 259.00
colour delivered from authorized local agent of the manufacturer(Berger luxury silk
emulsion/Elite super aclose silky finish/Asian royal luxury silk emulsion or equivalent
brand) in a sealed container; applying to interior wall and ceiling with surface preparation
including cleaning drying, making free from dirt, grease, wax, removing all chalked and
scaled materials, fungus, mending good the surface defects using sand paper and
necessary scaffolding; applying 1 coat of interior sealer of specified brand on prepared
surface; then applying 1 coat of interior putty of specified brand for levelling, spot filling,
crack filling and cutting by sand paper/zero water paper; finally applying 2 coats of interior
emulsion paint spreading by brush/roller/spray & necessary scaffolding etc. upto desired
finishing, elapsing specified time for drying or recoating; all complete in all floors and
accepted by the Engineer-in-charge
101
16.7 Epoxy enamel paint of approved quality and colour delivered from authorized local agent sqm Tk. 418.00
of the manufacturer in a sealed container; surface preparation including cleaning, drying,
making free from dirt, grease, wax, removing all chalked and scaled materials, fungus (if
required must be treated with fungicidal solution) flaking paints, washing the surface with
soap water/caustic soda, mending good the surface defects, smoothening the surface by
putty, sand papering the surface; applying to concrete surfaces and walls in three coats
by brush/roller/spray etc. upto desired finishing;elapsing specified time for drying and
recoating;
with necessary scaffolding all complete in all floors and accepted by the Engineerin-
charge.
16.8 Silicon based water repellent of approved quality delivered from authorized local agent sqm Tk. 226.00
of the manufacturer in a sealed container; surface preparation including cleaning, drying,
making free from dirt, grease, wax, removing all chalked and scaled materials, fungus,
mending good the surface defects using sand paper and necessary scaffolding; applying 3
coats of silicon based water repellent on exposed brick surface/fair face surface
spreading by brush/roller/spray & necessary scaffolding etc. upto desired finishing,
elapsing specified time for drying or recoating; all complete in all floors and accepted by
the Engineer-in-charge
16.9 French polishing to door and window frames and shutter by three coats over a coat of sqm Tk. 372.00
priming including putty, cleaning, finishing and polishing with sand paper etc. all complete
in all floors and accepted by the Engineer-in-charge.
16.10.0 Wood varnishing of approved quality and colour delivered from authorized local agent of
the manufacturer in a sealed container using brand specified thinner to door and window
frame and shutter in three coats, applied with brush including cleaning oil, grease, dirt,
making dry, sand papering, if required washing with weak detergent solution, stripping out
the colour straps, finishing the surface, etc. all complete in all floors and accepted by the
Engineer-in-charge.
16.11 Approved best quality and colour synthetic polyvinyl distemper delivered from sqm. Tk. 196.00
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling with surface preparation including cleaning drying, making free from dirt, grease,
wax, removing all chalked and scaled materials, fungus, mending good the surface defects
using sand paper and necessary scaffolding; applying 1 coat of interior sealer of specified
brand on prepared surface; then applying 1 coat of interior putty of specified brand for
levelling, spot filling, crack filling and cutting by sand paper/zero water paper; finally
16.12 applying
White 2 coatsbyofthree
washing synthetic
coats,polyvinyl distemper
lime mixture spreading
prepared at leastby12brush/roller/spray
hours before use,& sqm. Tk. 22.00
slacking stone lime, supplying of gums, blue, stirring thoroughly, removing the floating
16.13 materials
Colour fromwith
wash theyellow
mixer, orchard/any
surface cleaning
othertocolour
free from all foreign
pigment by twomaterials before
coats over a prime coat sqm. Tk. 25.00
of white wash, lime mixture prepared at least 12 hours before use, slacking stone lime,
supplying of gums, blue, stirring thoroughly, removing the floating materials from the
mixer, surface cleaning to free from all foreign materials before application of each coat,
applying one vertical and one horizontal wash for each coat and successive coat is to be
103
17.4 Average 100 mm thick finished lime terracing with 20 mm down graded first class brick cum Tk. 13,165.00
chips (khoa), surki from 1st class bricks and minimum lime content 500 kg per 2.83 cubic
meter (stone lime brought at site, not being powdered in open air and to be slaked in
presence of engineer-in-charge and to be measured in volume three days after slaking for
using in the mix) in the proportion 7:2:2 (brick chips : surki : lime) including preparation of
the mix on the ground by making a suitable platform under proper polythene cover. Cutting
the mix twice daily with limewater (1:10) at least for 7 days until the mix attain desirable
consistency. Laying the mix in proper slope, beating the same with standard „koppa‟ for
minimum 7 days to gain maximum consolidation, making ghoondy and neat finishing with
lime Surki mortar (1:2) and curing for 21 days providing polythene cover after each day
work and cleaning etc. complete in all respect accepted by the Engineer-in-charge.
17.5.2 25 mm thick ferrocement treatment work for heat and water proofing on roof having sqm. Tk. 1,603.00
minimum cement content relates to mix ratio 1:2 cement conforming to BDS EN-197-1-
CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type–1, and best quality coarse sand (F.M. 2.2)
including, the supply of all materials, cutting, binding of one layer of 20 BWG galvanized
wire mesh having minimum yield strength fy = 450 Mpa & having 2 mesh per 25mm in
both ways, clear cover 12mm at the middle of the ferrocement lining, applying 62 mm thick
EPS sheet having density 15 kg per cum, with washing of sand, chipping, cleaning the
surface, watering, grouting, casting, laying on proper level of roof top or floor in panels
(1.25 m x 1.25 m). Compaction including leveling, curing at least for 21 days including cost
of water, electricity, in all respect as per drawing, design and accepted by the Engineer-
incharge.
18.2.5 Supplying, fitting and fixing of 0.6 mm thick best quality solid aluminium metal board sqm. Tk. 2,676.00
false ceiling of size 600 mm x 600 mm, powder coated of approved design, framing by
aluminium T-bar of natural anodized finish suspended in 600 mm x 600 mm grid from
ceiling by 12 SWG double ply wire, fixed to the ceiling by rowel plug, screws, hooks, nails
etc., maintaining straight lines and desired finished level at bottom face including vertical
wooden strut as required, making holes in slabs or beams by electric drill machine and
mending good the damages, if any during execution of the work, also including cost of all
materials, electricity, accessories, scaffoldings, labour for installation, screws, nails, etc. all
complete as per drawing, design and accepted by the Engineer-in-charge.
18.2.6 Supplying, fitting and fixing of 0.6 mm thick best quality perforated aluminium metal sqm. Tk. 2,980.00
board false ceiling of size 600 mm x 600 mm, powder coated of approved design, inner
side is coverd by black tissue/ fabric to protect the hole from air circulation, framing by
aluminium T-bar of natural anodized finish suspended in 600 mm x 600 mm grid from
ceiling by 12 SWG double ply wire, fixed to the ceiling by rowel plug, screws, hooks, nails
etc., maintaining straight lines and desired finished level at bottom face including vertical
wooden strut as required, making holes in slabs or beams by electric drill machine and
mending good the damages, if any during execution of the work, also including cost of all
materials, electricity, accessories, scaffoldings, labour for installation, screws, nails, etc. all
complete as per drawing, design and accepted by the Engineer-in-charge.
106
18.3.2 Supplying, fitting and fixing 12 mm thick particle board in walling with best quality and sqm. Tk. 3,706.00
well seasoned Garjan wood frame of section 75 mm x 38 mm at 600 mm x 600 mm in grid,
fitted and fixed to wall by plugs, nails, screws etc. including treatment of inner surface with
termite and damp proofing agent maintaining leveled and finished exposed faces
including. making holes in wall and mending good the damages, if any during execution of
the work, also including cost and carriage of all materials, electricity, accessories, labour
for installation, scaffolding, screws, nails etc. including french polishing by 3 coats over a
coat of priming etc. all complete as per design, approved sample and accepted by the
Engineer-in-charge.
18.3.3 Supplying, fitting and fixing best quality wall paper along with 12 mm thick PVC solid sqm. Tk. 1,048.00
board in walling with furring chanel frame of section 75 mm x 38 mm at 600 mm x 600 mm
in grid, fitted and fixed to wall by plugs, nails, screws etc. including treatment of inner
surface with termite and damp proofing agent maintaining leveled and finished exposed
faces including making holes in wall and mending good the damages, if any during
execution of the work, also including cost and carriage of wall paper and other materials,
electricity, accessories, labour for installation, scaffolding, screws, nails etc. all complete
as per design, approved and accepted by the Engineer-in-charge.
18.3.4 Supplying, fitting and fixing best quality wall paper on finished plaster surface including
cost and carriage of wall paper and other materials, electricity, accessories, labour for
installation, scaffolding, screws, nails etc. all complete as per design, approved and
accepted by the Engineer-in-charge.
19.1.2 Manufacturing, supplying, fitting and fixing collapsible gate of any design and shape sqm. Tk. 14,217.00
made of 20 mm x 20 mm x 3 mm S.S. angle placed @ 112 mm c/c vertically and
connecting the same with each other by 20 mm x 3 mm S.S flat bar scissors 525 mm/ 600
mm long provided in 3 rows including cutting the different S.S. members to required sizes,
fabricating, welding, riveting with required size rivets, providing required size wheels,
pulling handles on both sides, suitable locking arrangement, electrodes, grease and finally
placing the same in position in between 2 (two) nos. 50 mm x 50 mm x 6 mm S.S. tee rail
made by welding 2 nos. 50 mm x 6 mm S.S. flat bar fitted and fixed at top and bottom with
R.C.C. lintel/roof slab, floors and side wall with required Nos. 150 mm to 225 mm long 38
mm x 6 mm S.S. flat bar clamps one end welded with the gate member and the other end
bifurcated and embedded in C.C. at the respective point including cutting holes and
mending good the damages by pouring concrete (1:2:4) into the holes and finishing, both
end carriage, including greasing, electrodes, curing etc. complete as per drawing and
design and accepted by the Engineer-in-charge.
19.1.3 Manufacturing, supplying, fitting and fixing collapsible gate of any design and shape sqm. Tk. 5,299.00
made of 25 mm x 25 mm x 3 mm M.S. angle placed @ 112 mm c/c vertically and
connecting the same with each other by 25 mm x 3 mm M.S flat bar scissors 525 mm/ 600
mm long provided in 3 rows including cutting the different M.S. members to required sizes,
fabricating, welding, riveting with required size rivets, providing required size wheels,
pulling handles on both sides, suitable locking arrangement, electrodes, grease and finally
placing the same in position in between 2 (two) Nos. 50 mm x 50 mm x 6 mm M.S. tee rail
made by welding 2 nos. 50 mm x 6 mm M.S. flat bar fitted and fixed at top and bottom
with R.C.C. lintel/roof slab, floors and side wall with required nos. 150 mm to 225 mm long
38 mm x 6 mm M.S. flat bar clamps one end welded with the gate member and the other
end bifurcated and embedded in C.C. at the respective point including cutting holes and
mending good the damages by pouring concrete (1:2:4) into the holes and finishing, etc
complete, painting 2 (two) coats with approved best quality synthetic enamel paint over a
coat of anticorrosive painting, both end carriage, including greasing, electrodes, curing
etc. complete as per drawing and design and accepted by the Engineer-in-charge.
(Rate is excluding the cost of painting)
108
19.2.1 Supplying, fitting, fixing, and installation of ordinary type M.S. gate (double leaf) of any sqm. Tk. 6,036.00
design and shape with 38 x 38 x 6 mm M.S. Angle outer frame having 16 mm dia M.S. rod
placed vertically @ 75 mm c/c. at bottom part and top part (200 mm long arrows) and also
placed horizontally at bottom for interconnection of 16 mm dia M.S. rod placed vertically as
19.2.2 Manufacturing, supplying and fitting-fixing security door with 25 mm dia M.S. rod and sqm. Tk. 10,767.00
outer frame with 50 mm x 50 mm x 6 mm M.S. angle including locking arrangement as per
approved design and drawing providing 38 mm x 38 mm x 6 mm M.S. angle clamps fitted
19.3 Supplying, fitting, fixing, and installation of ordinary type M.S. security gate of any sqm. Tk. 5,283.00
design and shape with 50 mm x 50 mm x 6 mm M.S. angle outer frame and 02 (two) 50
mm x 50 mm x 6 mm angle placed diagonally having 22 mm dia M.S. rod placed vertically
@ 115 mm c/c. and also 38 mm x 6 mm F.I placed horizontally, the bottom part covered
with 3 mm thick M.S. sheet providing locking arrangements on 3 mm thick M.S. plate
providing heavy type clamps fitted and fixed with the outer frame of the main gate, the
clamp being embedded in R.C.C. or R.C. core pillar with cement concrete (1:2:4) in
masonry including cutting holes and mending good the damages, finishing, curing etc.
including fabrication, riveting, welding as and where necessary, etc. all complete as per
drawing, design and accepted by the Engineer-in-charge.
19.4 Supplying, fitting, fixing and installation of ordinary type M.S. gate (double leaf) of any sqm. Tk. 7,843.00
design and shape with 38 mm x 38 mm x 6 mm M.S. angle box (made by welding 2 nos.
38 mm x 38 mm x 6 mm angle) outer frame having 25 mm x 50 mm x 25 mm x 5 mm M.S.
channel (made by welding 2 nos. of channel) placed part diagonally after cutting and
shaping as per requirement, part horizontally @ 75 mm c/c, the two part of each leaf being
separated by a vertical member of 38 mm x 38 mm x 6 mm M.S. box and welded the each
ends of diagonal and horizontal members properly with the box frame as per architectural
drawing providing full locking arrangement on 3 mm thick M.S. plates providing 38 mm x
38 mm x 6 mm M.S. angle clamps, fitting fixing with the outer frame of the gate, the clamp
19.5 Manufacturing, supplying, fitting and fixing G.I. pipe gate of any design and shape having sqm. Tk. 9,011.00
38 mm dia G.I. pipe outer frame and 19 mm dia. G.I. pipe vertical member placed @ 75
mm c/c by welding at top and bottom of G.I. pipe frame, cutting the pipes in proper shape
and size including making semicircular band at the corners of the outer frame without
damaging the pipe, covering 50% of the gate area with 18 BWG M.S. sheet, providing also
two extra horizontal 38 mm dia G.I. pipes welded with vertical post, providing 6 nos. huskle
domney with R.C.C. or R.C.C core pillar with cement concrete (1:2:4) in masonry including
cutting holes, mending good the damages, making provision for minimum 0.61 m x 1.4 m
pocket gate having its outer frame and inner vertical members made with 19 mm dia G.I.
pipe including necessary locking arrangements. Painting the gate with 2 (two) coats of
synthetic enamel paint over a coat of anti-corrosive priming, welding as and where
109
20.1 Manufacturing, supplying, fitting and fixing of stair railing of any standard height of any sqm Tk. 3,441.00
design and shape with square box (2 nos.in each tread) made by thorough welding of 2
nos. 19 mm x 19 mm x 3 mm M.S. angle to provide hand-rail, engraving each box 150
mm in the concrete by 50 mm x 50 mm x 6 mm anchor plate at base, welding 38 mm x 6
mm F.I. bar inclined plain with the top of the box to fit in the grooved wooden rail by
necessary screws including cutting grooves in concrete, mending good the damages with
cement concrete (1:2:4), applying first class polish to hand rail, 2 (two) coats of synthetic
enamel paint of approved quality over a prime coat etc. finished in all respect for all floors
and accepted by the Engineer-in-charge.(Exposed area of railing will be considered for
measurement, rate is excluding the cost of hand-rail and cost of painting).
20.2 Manufacturing, supplying, fitting and fixing of stair railing of standard height of any design sqm Tk. 6,614.00
and shape with square box (2 nos. box in each tread) made by thorough welding of 2
nos. 25 mm x 25 mm x 5 mm M.S. angle, engraving each box 150 mm in the concrete by
50 mm x 50 mm x 6 mm anchor plate at base, welding 50 mm x 50 mm x 6 mm F.I. bar in
inclined plain with the top of the box fitted in the grooved wooden rail and 2 Nos. 225 mm x
25 mm finished section of wooden strip fitted and fixed at mid height of railing at both side
of M.S. angle box in inclined plain parallel to the hand rail etc. fitted and fixed by
necessary screws, nails including cutting grooves in concrete, mending good the damages
with cement concrete (1:2:4) applying 1st class french polish to wooden hand rail and
inclined wooden strip and painting to F.I bar and square box with 2 (two) coats of synthetic
enamel paint of approved quality and colour over a prime coat etc. complete in all respect
20.3 Supplying, fitting and fixing 12 mm dia G.I pipe stair railing of any standard height of any
design and shape with 50 mm x 50 mm x 6 mm M.S. plate at the base of 12 mm dia G.I.
Pipe and fitted and fixed by welding. Placing the pipes vertically @ 250 mm c/c (1 nos. in
each steps) 150 mm embedded into the R.C.C tread of stair case after cutting grooves
and mending good the damages with C.C. and providing 38 mm x 6 mm F.I. bar on the top
of G.I. pipe to provide wooden hand rail of any design including polishing, painting etc. all
complete and accepted by the Engineer-in-charge. (Exposed area of railing will be
considered for measurement, rate is excluding the cost of paint, wood for railing)
20.3.1 With the provision of hand rail of size: 150 mm x 62 mm (finished) sqm Tk. 2,193.00
20.3.2 With the provision of hand rail of size: 112 mm x 62 mm (finished) sqm Tk. 2,895.00
20.4 Supplying, fitting and fixing stainless steel (SS) stair railing of standard height with 2 mm sqm Tk. 5,361.00
thick 62 mm dia pipe for hand-rail, 2 mm thick 40 mm dia 5 nos vertical pipes in each
flight, 2 mm thick 20 mm dia 5 nos horizontal pipes as per drawing, design including
carrying, polishing fabricating, welding and fixing with tread by 25 mm long royal bolt etc.
all complete and accepted by the Engineer-in-charge.
110
20.7 Supplying, fitting and fixing 10 mm thick tempered glass railing in stair with 62 mm dia sqm Tk. 9,787.00
2 mm thick SS pipe for hand rail, 5 nos 62 mm x 50 mm x 2 mm vertical pipe in each flight
fitted and fixed with 65 mm x 55 mm x 6 mm SS base plate including welding, bending,
fabricating, polishing all complete as per drawing, desing and specification etc all complete
in all respect and accepted by Engineer-in-charge.
20.8 Supplying, fitting and fixing 10 mm thick tempered glass railing in verandah with 62 sqm Tk. 11,717.00
mm dia 2 mm thick SS pipe for hand rail, 5 nos 62 mm x 50 mm x 2 mm vertical box fitted
with concrete slab by 65 mm x 55 mm x 6 mm SS plate @ 600 mm c/c including all fittings,
fixtures as per drawing, desing and specification etc all complete in all respect and
accepted by Engineer-in-charge.
20.9 Providing nosing to the nose of tread of stair including supplying 3 nos. of 75 mm long
12 mm x 3 mm F.I./SS bar clamps with bifurcated ends in each treads including fitting and
fixing with the angle by welding and fitting and fixing the angle by cutting grooves in R.C.C,
fixing and finishing and the same with C.C. (1:2:4) etc. cost of electricity and other charges
all complete and accepted by the Engineer-in-charge.
20.9.1 Providing 38 mm x 38 mm x 6 mm M.S. angle to the nosing of steps of staircase meter Tk. 372.00
20.9.2 Providing nosing 32 mm x 32 mm x 6 mm M.S. angle to the nosing of steps of stair case. meter Tk. 327.00
20.9.3 Providing 25 mm x 25 mm x 6 mm size M.S. angle to the nosing of stair case. meter Tk. 283.00
20.9.4 Providing 38 mm x 38 mm x 6 mm brass angle to the nosing of steps of stair case meter Tk. 1,439.00
20.9.5 Providing 38 mm x 38 mm x 6 mm S.S. angle to the nosing of steps of staircase meter Tk. 1,252.00
20.9.6 Providing 32 mm x 32 mm x 6 mm S.S. angle to the nosing of steps of stair case meter Tk. 1,002.00
20.9.7 Providing 25 mmx 25 m x 6 mm size S.S. angle to the nosing of stair case. meter Tk. 919.00
20.10.0 Supplying, fitting & fixing of column guard made of 50 mm x 50 mm x 6 mm M.S. angle sqm Tk. 504.00
around column & 50 mm x 6 mm F.I. bar for Tie at the top including fitting and fixing with
the angle by welding, fitting and fixing the angle by cutting grooves in R.C.C, fixing and
finishing the same with C.C. (1:2:4) etc. cost of electricity and other charges all complete
and accepted by the Engineer-in-charge
111
21.8 Supplying, fitting and fixing 12 BWG barbed wire (2 ply, 4 points) in fencing work @ sqm Tk. 887.00
150 mm c/c both horizontally and vertically, supported by 38 mm x 38 mm x 6 mm
M.S. Y-shape angle post (300 mm embedded in R.C.C. or in brick work with a cement
concrete base of 75 mm x 75 mm x 300 mm) 600 mm vertical and 450 mm inclined or as
per requirement @ 2.4 m c/c including straightening, binding the joints with 18 BWG wire,
making holes in the angle etc. including supplying all necessary materials complete in all
respect and accepted by the Engineer-in-charge. (Rate is excluding the cost of R.C.C or
brick work or C.C. which is to be paid as per corresponding items in the schedule)
21.9 Supplying, fitting and fixing 12 BWG barbed wire fencing in a circular shape of 600 mm sqm Tk. 2,427.00
dia and 76 mm pitch fitted with MS rod casing (made by 8 nos. 10 mm dia plain bar in a
circular pattern and placed at equal interval ), 38 x 38 x 6 mm M.S. angle post (300 mm
embedded in R.C.C. or in brick work with a cement concrete base of 75 mm x 75 mm x
300 mm) and 600 mm vertical and 450 mm inclined placed @ 3.0 m c/c including
straightening, binding the joints with 18 BWG wire, making holes in the angle etc. including
supply of all necessary materials complete in all respect and accepted by the Engineer-
incharge.
(Rate is excluding the cost of R.C.C or brick work or C.C. which is to be paid as
per corresponding items in the schedule)
DIVISION 22 : MISCELLANEOUS ITEMS
22.1 Supplying, fitting and fixing of wooden wedge (12 mm base x 12 mm height) instead of meter Tk. 68.00
putty for fixing glass panes with wooden frame by nails or by any other approved method
including the cost of necessary wood, painting/polishing, nails etc. and excluding the cost
of wooden frame, and painting and 5 mm thick glass panes all complete and accepted by
the Engineer-in-charge
22.2 Supplying, fitting and fixing of 20 mm dia foreign made aluminium pipe curtain rail for meter Tk. 655.00
door and window including cutting and fitting fixing as per required measurement and
supplying necessary screws, electric drill and rowel plug including charge of electricity etc.
complete and accepted by the Engineer-in-charge.
22.3 Supplying, fitting and fixing 10 mm thick clear tempered glass door including all sqm Tk. 15,604.00
accessories, 1 set floor mounted auto door closure, special quality 2 nos clamping
devices, 1 set locking device, top hinge and handle etc. complete in all respect as per
drawing and direction of the Engineer-in-charge
22.4 Supplying, fitting and fixing 10 mm thick clear glass partition with 44 mm, 44 mm, 1.5 sqm Tk. 2,861.00
mm aluminium box, protector bit (single), protector bit (double) including all accessories
etc. all complete and as per drawing and direction of the Engineer-in-charge
113
22.6 Supplying, fitting and fixing vertical venetian blinds made with glass fiber fabrics (foreign sqm Tk. 1,896.00
made) with supply of all materials (foreign made) such as head rail (aluminium), end capset,
rod tilt, sigger (stopper), runner, spacer (link), handling cord, ball chain, link chain,
cord-weight weight-plate plastic washer, glass fiber fabrics, and head cap-set etc. all
complete and accepted by the Engineer-in-charge
22.7 Supplying, fitting and fixing horizontal venetian blinds of 25 mm width made with sqm Tk. 1,440.00
aluminium foils/ strips (foreign made) with supply of all materials (foreign made) such as
head rail, bottom rail, rod tilt, head cap, bottom cap, gear box, stick, support and cap, cord
drum and support, bracket, cord lock, cord equalizer, top holder, ladder, cord, handling
cord and aluminium foils etc. all complete and accepted by the Engineer-in-charge.
22.8 Supplying, fitting and fixing of horizontal zebra blind made with polyester fabrics, sqm Tk. 3,260.00
synthetic net with 3 inch vinyl/upvc coated strips (foreign made) with supply of all materials
(foreign made) such as head rail, bottom rail, rod tilt, head cap, bottom cap, gear box,
stick, support and cap, cord drum and support, bracket, cord lock, cord equalizer, top
holder, ladder, cord, handling cord and aluminium foils etc. all complete and accepted by
the Engineer-in-charge.
22.9 Supplying, fitting and fixing of blackout/ translucent roller blind of PVC/ vinyl laminated sqm Tk. 2,594.00
fiberglass fabrics (foreign made) with supply of all materials (foreign made) such as head
rail (aluminium), end cap-set, rod tilt, sigger (stopper), runner, spacer (link), handling cord,
ball chain, link chain, cord-weight weight-plate plastic washer, glass fiber fabrics, and head
cap-set etc. all complete and accepted by the Engineer-in-charge.
22.10 Supplying, fitting & fixing of steel iron rack made of 50 mm x 50 mm x 6.35 mm vertical sqm Tk. 9,578.00
and horizontal angle post, welding 63.5 mm x 6.35 mm F.I. bar placed horizontally as
bracing for the posts, 38 mm x 6.35 mm cross F.I. bars welded with vertical post, 12.7 mm
thick M.S plate welded as cup shape at the bottom of post, supplying and fitting rivets,
charge for welding, drilling, carrying, cutting, straightening in required sizes etc in all
respect as per drawing, design and accepted by the Engineer-in-charge
22.11 Supplying fitting & fixing of uPVC plastic door or window frame having specific gravity meter Tk. 278.00
1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties etc. as per
BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards fitted and fixed in
brick wall/ R.C.C wall with 6 Nos. GI clamp, 4 nos inner joint GI clamp, 2 nos. outer GI
joint
clamp, 16 nos. rivet making necessary grooves and mending good the damages, finishing,
curing, carriage etc complete in all respect accepted by the Engineer-in-charge.
22.12 Supplying, fitting, fixing of uPVC hollow or solid plastic door shutter having specific
gravity of 1.35 - 1.45, thickness 1.7 mm-2.2 mm, and other physical, chemical, thermal,
fire resistivity properties etc. as per BSTI approved manufacturer standards or ASTM,
BS/ISO/IS standards of different sizes, fitted fixed with uPVC plastic door frame weighing
5.82 kg/m2 with at least 3 Nos. SS hinges by min 64 Nos. Ø 3.17 mm and 3.97 mm 12.7
mm long rivets, 12 nos. 25.4 mm SS screws, Ø 9.38 mm, 150 mm long SS tower bolts 2
nos., 146 mm SS handle by rivet 2 Nos., G.I inner joint, 234.95 mm x 127 mm clamp, 76.2
mm x 57.15 mm, 25 mm dia 1 no ss haspbolt, special type round lock, carrying the same
to the site and local carriage etc. complete in all respect and accepted by the Engineer-
incharge.
22.12.1 760 mm x 1980 mm uPVC plastic shutter (hollow). each Tk. 3,650.00
22.12.2 760 mm x 2130 mm uPVC plastic shutter (solid). each Tk. 3,762.00
114
22.12.4 990 mm x 2130 mm uPVC plastic shutter (solid). each Tk. 4,130.00
22.13 Supplying, fitting & fixing of uPVC plastic or glass partition in plastic frame fabricated
by 70 mm x 50 mm x 2 mm T and 50 mm x 40 mm x 2 mm / 50 mm x 30 mm x 2 mm
Lsections,
providing partition with 156 mm x 25 mm uPVC hollow section having wall
thickness of 2.5 mm / partition with 5 mm thick glass. physical, chemical, thermal, fire
resistivity properties etc of the materials as per BSTI approved manufacturer standards or
ASTM, BS/ISO/IS standards, fitted and fixed in brick wall or R.C.C wall with 6 nos. GI
clamps, 4 nos. inner joint GI clamps, 2 nos. outer GI joint clamps, 16 nos. rivets, making
necessary grooves and mending good the damages, finishing, curing, carriage etc
complete in all respect and accepted by the Engineer-in-charge
22.13.1 With partition of uPVC hollow section sqm Tk. 2,666.00
22.14 Supplying, fitting & fixing of uPVC Profile for door, window and fixed partition frames each Tk. 527.00
applications having specific gravity of 1.36-1.43, and other physical, chemical, thermal, fire
resistivity properties etc. as per BSTI approved manufacturer standards or ASTM,
BS/ISO/IS standards including all accessories, fittings with 6 nos. steel clamps complete in
all respect as per drawing and accepted by the Engineer-in-charge
22.15 Supplying, fitting & fixing of swing door shutter made of low density free foam (LDFF)
sheet having standard size 1200 mm x 3200 mm. Physical properties: density: 0.55-0.68
g/cm3, weighing 1.3 kg/sft, providing new sash (100 mm), sliding glass bead, rubber,
screws, 75 mm hinges 4 Nos., 100 mm tower bolt 2 Nos., 150 mm handle 2 nos. etc.
including all accessories complete in all respect as per drawing and accepted by the
Engineer-in-charge.
22.15.1 1950 mm x 750 mm size 8 mm thick uPVC swing door shutter each Tk. 9,832.00
22.15.2 2100 mm x 750 mm size 8 mm thick uPVC swing door shutter each Tk. 10,109.00
22.15.3 2100 mm x 900 mm size 8 mm thick uPVC swing door shutter each Tk. 10,387.00
22.16 Supplying, fitting & fixing of plastic wall paneling with 3 mm sheet, weighing 0.188 kg/sft, sqm Tk. 1,268.00
fitting and mending good the damages, carriage to the site including glass bead, partition
frame, rubber, 5 mm clear glass fitted and fixed with screws, steel clamp etc all complete
and accepted by the Engineer-in-charge.
22.17 Supplying, fitting & fixing of uPVC profile fixed partition with 5 mm clear glass, weighing sqm Tk. 3,385.00
1.032 kg/sft, fitting and mending good the damages, carriage etc. complete in all respect
and accepted by the Engineer-in-charge.
22.18 Supplying, fitting & fixing of uPVC profile sliding window having gross weight of 14.00 sqm Tk. 13,740.00
kg/sqm (including 5 mm glass) fitting and mending good the damages, carries etc
complete in all respect accepted by the Engineer-in-charge.
22.18.1 uPVC sliding window with 5 mm glass (1200 mm x 1200 mm size) sqm Tk. 4,667.00
22.18.2 uPVC sliding window without glass (1200 mm x 1200 mm size) sqm Tk. 3,815.00
115
22.20.0 Supplying, fitting and fixing of approved quality 190 mm x 190 mm size glass bricks in sqm Tk. 14,910.00
round stair wall including all accessories & charges, complete in all respect and accepted
by the Engineer-in-charge.
22.21 Supplying, fitting & fixing 50 mm thick rock or glass wool padding of approved quality sqm Tk. 3,843.00
and accepted by the Engineer-in-charge.
22.22 Manufacturing supplying, fitting and fixing of single leaf louver door shutter made with sqm Tk. 22,545.00
16 gauge thick 50 mm x 50 mm SS hollow box as outer frame, 16 gauge thick 50 mm x 38
mm SS hollow box as pannel frame and 18 gauge thick 50 mm x 12 mm SS hollow box as
louver with 150 mm long 12 mm dia SS handle, 300 mm long 20 mm dia ss hasp bolt, 100
mm hings etc, comple in all respect and accepted by the Engineering-in charge.
22.23.1 Supplying, laying, fitting & fixing best quality 225 mm dia (internal) machine made meter Tk. 1,359.00
R.C.C. pipe over 100 mm thick cement concrete (1:3:6) at base and sides including single
brick flat soling and gasket with cement mortar (1:4) joints, cutting and filling trenches up
to required depth including excavation of soil etc. all complete in all respect as per type
plan and accepted by the Engineer-in-charge (average depth of trench is 1050 mm).
(Cement: CEM-II/A-M)
22.23.2 Supplying, laying, fitting & fixing best quality 300 mm dia (internal) machine made meter Tk. 2,214.00
R.C.C. pipe over 100 mm thick cement concrete (1:3:6) at base and sides including single
brick flat soling and gasket with cement mortar (1:4) joints, cutting and filling trenches up
to required depth including excavation of soil etc. all complete in all respect as per type
plan and accepted by the Engineer-in-charge (average depth of trench is 1050
mm).(Cement: CEM-II/A-M)
116
22.24 Supplying, making, fitting & fixing of R.C.C. door/window frame of 155 mm x 65 mm meter Tk. 136.00
which is made by using M.S. rod (fy = 400 MPa) fabrication work with 24 BWG G.I. wire,
22.25 steel formworks
Supply with of
& installation minimum cement
fire rated concrete relates
door complete mix ratio
& accepted (1:2:4)
by the having minimum
Engineer-in-charge sqm Tk. 48,217.00
with the following specification:Standard(s) for safety : UL Certified, NFPA 80 standard
ANSI / UL 10C: Positive pressure of fire tests of door assemblies.
ANSI / UL 10B: Fire tests of door assemblies.
UL Subject 63: Outline of investigation for fire frames.
Shutter materials: Mild steel.
Fire resistivity (Door & frame): Two hours.
Fire resistivity (accessories): Three hours (panic bar, pul handle, ceramic fibre tape for
sealing smoke, hinge, bolt and screw, mortice lock, door closer
Door frame: 2 vertical fire resisting jamb and 1 fire resisting horizontal jamb made with
single rabbet hollow steel chanel frame made of 2.3 mm imported cold rolled mild steel
sheet. Four SS hinges (size: 112 mm x 100 mm x 3.4mm) are used on each leaf screwd
with frame
Door leaf: Door leaf faces consists of 1.6 mm thick imported cold rolled MS sheet attached
together using interlocking mechanism and tack welding which is filled with imported
100kg/m3 rock wool cake. Stiffeners should be used inside to strengthen structure.
Vision Panel: Made of UL certified 5 mm glass. It has clear vision area of 150 mm x 100
mm. Its frame is mae of 1.6 mm imported cold rolled MS sheet and SS pop rivet used for
fixing. Ceramic fibre tape is used for sealing smoke.Internal insulation: Rock wool.
Surface treatment: All MS sheets are chemically treated coated with zinc phosphate
before assembly in highly equipped chemical treatment plant. All chemicals are imported.
Paint Finish: Epoxy powder coated paint finish and curing in temperature controlled gas
oven.
23.1 Supplying, fitting & fixing of pre-cast ferrocement roof panel which is made by using
vibration table & steel shutter with minimum cement content relates to mix ratio 1:2 for
flange having minimum compressive strength 30 MPa (28 days standard cube strength)
and cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C150 type- 1,
best quality coarse sand of equivalent F.M. 2.2, 2 layers of 18 BWG galvanized/epoxy
coated wire mesh having minimum yield strength fy= 450 MPa & having 2 meshes per 25
mm and reinforced cement concrete works for rib with minimum cement content relates to
mix ratio 1:1.5:3 having minimum f‟cr = 30 MPa and satisfying a specified compressive
strength f'c = 25 MPa, best quality coarse sand of equivalent F.M. 2.2 and 12 mm down
well graded stone chips conforming to ASTM C-33, supplying, fabrication and fixing to
details as per design, deformed bar reinforcement BDS ISO 6935-2:2006, including
straightening and cleaning rust, if any, bending and binding in position with supply of 24
nos GI wires, remove the shuttering, lifting the panel to floor/roof level, keeping on proper
position, filling the interstices with cement concrete (1:1.5:3), satisfying a specified
compressive strength f'c = 25 MPa, stitching overlapped wire meshes with 18 BWG GI
wire, filling with mortar (1:2), casting of 25 mm thick as screeding (1:1.5:3) using 6 mm
down stone chips and M.S. rod (fy=400 MPa) with fabrication over F.C. panel including the
cost of reinforcement & wire mesh, curing at least for 7 days including the cost of water,
electricity and other charges all complete as per design, drawing and accepted by the
Engineer-in-charge
117
23.1.2 Extra cost shall be incorporated in the estimate for each additional floor
23.1.2.1 Add for each additional span length of 150 mm long direction (3810 mm<span ≤ 4800 sqm Tk. 9.00
mm)
23.1.2.2 Add for each additional floor up to 5th floor sqm Tk. 35.00
23.1.2.3 Add for each additional floor from 6th floor sqm Tk. 40.00
23.2 Supplying, fitting & fixing of 20 mm thick ferrocement folded plate roof which is made by
using vibration table & steel shutter with minimum cement content relates to mix ratio 1:2,
having minimum compressive strength of 30 MPa (28 days standard cube strength) and
cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type- 1,
best
quality coarse sand of equivalent F.M. 2.2, 1 layer of 20 BWG galvanized/epoxy coated
wire mesh having minimum yield strength fy=450 MPa & having 2 meshes per 25 mm,
fabrication and fixing to details as per design, deformed bar reinforcement BDS ISO 6935-
2:2006, including straightening and cleaning the rust, if any, bending and binding in
position with supply of 24 BWG GI wires, removing the shutter, lifting, keeping on proper
position, curing at least for 7 days including the cost of water, electricity and other charges
all complete as per design, drawing and accepted by the Engineer-in-charge.
23.2.1.1 Add for each additional span length of 150 mm long direction (3810 mm < span ≤ 4800 sqm Tk. 9.00
mm)
23.2.2.1 Add for each additional floor up to 5th floor sqm Tk. 35.00
23.2.2.2 Add for each additional floor from 6th floor sqm Tk. 40.00
23.3 Supplying, fitting & fixing of 20 mm thick ferrocement corrugated sheet roof which is
made by using vibration table & steel shutter with minimum cement content relates to mix
ratio 1:2, having minimum compressive strength of 30 MPa (28 days standard cube
strength) and cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C
150
type-1, best quality coarse sand of equivalent F.M. 2.2, 1 layer of 20 BWG
galvanized/epoxy coated wire mesh having minimum yield strength fy=450 Mpa & having
2 meshes per 25 mm and supplying, fabrication and fixing to details as per design,
deformed bar reinforcement BDS ISO 6935-2:2006 including straightening and cleaning
rust, if any, bending and binding in position with supply of 24 nos GI wires, removing the
shutter, lifting on ground floor roof, keeping on proper position, curing at least for 28 days
including the cost of water, electricity and other charges all complete as per design,
drawing and accepted by the Engineer-in-charge.
23.3.1 For ground floor, span up to 3810 mm for floor/roof slab. sqm Tk. 1,626.00
23.3.2 Extra cost shall be incorporated in the estimate for each additional floor
23.3.2.1 Add for each additional floor up to 5th floor sqm Tk. 35.00
23.3.2.2 Add for each additional floor from 6th floor sqm Tk. 40.00
118
23.4.1 For ground floor, span up to 3810 mm for floor/roof slab. sqm Tk. 1,375.00
23.4.2 Extra cost shall be incorporated in the estimate for each additional floor
23.4.2.1 Add for each additional floor up to 5th floor sqm Tk. 35.00
23.4.2.2 Add for each additional floor from 6th floor sqm Tk. 40.00
23.5 Supplying, making and fitting fixing of ferrocement door/window frame 155 mm x 65 mm meter Tk. 567.00
which is made by using M.S. rod (fy = 400 MPa) fabrication work minimum cement content
relates to mix ratio 1:2 cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/
ASTM-C 150 type–1, coarse sand (F.M. 2.2), cutting, bending, binding of one layer 20
BWG galvanized / epoxy coated wire mesh having minimum yield strength fy=450 MPa &
12 mm c/c gap in both directions with 24 BWG. G.I. wire, jute hassain, polythene sheet,
placing of 100 mm long welded iron hinges including 6 mm dia M.S. rod clamp fittings,
fixing in position, casting with neat cement finishing demoulding and lean cement sand
(1:8) cement, sand (F.M. 1:2) and curing at least for 28 days etc. all complete including the
cost of water, electricity, testing and other charge as per design, drawing and accepted by
the Engineer-in-charge. (Considering x- section of the frame is 153 mm x 64 mm).
23.6 25 mm thick cast-in-situ ferrocement wall with minimum cement content relates to mix sqm Tk. 1,719.00
ratio 1:2, cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150
type–1, and best quality coarse sand (F.M. 2.2) M.S. rod fabrication in accordance with
BDS, ISO 6935-2:2006 straighting and cleaning rust if any, bending and binding in position
with supply of 8 mm dia M.S. rod 250 mm c/c vertically, 6 mm dia 250 mm c/c
horizontally,
24 nos G.I. wire splices laps etc. 2 layers of 20 BWG galvanized wire mesh having
minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, casting and finishing the both
surfaces with cement sand (F.M.-1.2) mortar (1:3) and curing at least for 21 days,
including the cost of water, electricity and other charges in all complete as per drawing,
design and accepted by the Engineer-in-charge.
119
23.7.2 Add for each additional floor up to 5th floor sqm Tk. 18.00
23.7.3 Add for each additional floor for 6th floor to 9th floor sqm Tk. 28.00
23.7.4 Add for each additional floor for 10th floor and above sqm Tk. 32.00
23.8 90 mm thick partition wall with ferrocement sandwich panel wall (cast in situ) using
mortar having compressive strength not less than 15.0 N/mm2 and fitting-fixing of EPS
sheet size (3000 mm x 1200 mm x 63 mm),8 mm M.S. bar and its fabrication in both side
with 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh
per 25 mm, in compliance with ASTM C129 fairly uniform thickness and water absorption
not more than 7% including necessary scaffolding, cleaning and curing at least for 7 days
including cost of water, electricity and other charges etc. in all complete accepted by the
Engineer-in-charge
23.8.2 Add for each additional floor up to 5th floor sqm Tk. 13.00
23.8.3 Add for each additional floor for 6th floor to 9th floor sqm Tk. 18.00
23.8.4 Add for each additional floor for 10th floor and above sqm Tk. 21.00
23.9 40 mm ferro-cement slab on soil-cement stabilized sub-grade in ground floor etc. with sqm Tk. 1,247.00
minimum cement content relates to mix ratio 1:2 having minimum compressive strength of
30 MPa (28 days standard cube strength) and cement conforming to BDS EN-197-1-CEM-
1, best quality coarse (F.M. 2.2) sand, 2 layer of 20 BWG galvanized/epoxy coated wire
mesh having minimum yield strength fy=450 Mpa & having 2 mesh per 25 mm with
minimum clear cover 12 mm both top & bottom, true to desired level, placing, compacting,
curing at least for 7 days in all floors including cost of water, electricity and other charges
etc. all complete and accepted by the Engineer-in-charge
24.1.2 For additional lift of 1 m beyond 1.5 m up to 2.5 m cum Tk. 165.00
24.1.3 For additional lift of 1 m beyond 2.5 m up to 3.5 m cum Tk. 186.00
24.1.4 For additional lift of 1 m beyond 3.5 m up to 4.5 m cum Tk. 206.00
24.1.5 For additional lift of 1 m beyond 4.5 m up to 5.5 m cum Tk. 227.00
24.1.6 For additional lift of 1 m beyond 5.5 m up to 6.5 m cum Tk. 247.00
24.2 Earthwork in box cutting in all types of soil. Removing soil to a safe distance, maintaining
proper alignment, camber and grade including leveling, dressing and compacting the sub
grade as per drawing and accepted by the Engineer-in-charge.
24.3 Creating turf on the side slopes and top of embankment with good quality turf not less than sqm Tk. 17.00
225 mm square chunk, watering till the grass grown including all leads and lifts etc.
complete and accepted by the Engineer-in-charge.
24.4 Single layer brick flat soling in road work with first class or picked jhama bricks as per sqm Tk. 438.00
alignment, camber and grade including filling joints with sand (F.M. 0.80) etc. complete
including cost of all materials and accepted by the Engineer-in-charge.
24.5 Brick on edges pavement in herring bone bond (HBB) with first class or picked jhama sqm Tk. 713.00
bricks as per alignment, camber and grade over 12 mm thick sand cushion (F.M. 0.80)
including filling the joints with the same sand including cost of all materials and accepted by
the Engineer-in-charge.
24.6 Double brick flat soling in roadwork with first class or picked jhama bricks as per camber sqm Tk. 884.00
and grade and filling the joints with fine sand (F.M. 0.80) and also providing 12 mm thick
sand cushion in between the two layers of brick flat soling with the same quality of sand
including cost of all materials and accepted by the Engineer-in-charge.
24.7 Brick on end edging (75 mm across the road) with first class or picked jhama bricks and meter Tk. 111.00
filling the gaps with fine sand (F.M. 0.80) including cutting trenches, true to level and grade,
removing earth, refilling and ramming the sides properly including cost of all materials and
accepted by the Engineer-in-charge.
24.8 Breaking picked jhama, first class bricks or bats including cost of bricks and bats and
stacking in measurable sizes at site accepted by the Engineer-in-charge.
24.10.0 Providing compacted sub-base course with well graded material of crushed well burnt sqm Tk. 4,041.00
picked jhama / 1st class brick bats and sand (FM 0.8) with mixing proportion 2 : 1 having
compacted thickness made as per specification including local handling, spreading
uniformly to proper grade camber and super elevation, packing, rolling properly with 8 to
10 ton capacity power driven road roller and watering properly for compaction of 100%
MDD (standard) blinding with sand including cost of fuel, lubricants, spares, maintenance,
driver etc. all complete and accepted by the Engineer-in-charge
24.11 50 mm thick compacted pre-mixed bituminous carpeting with 20 mm down graded sqm Tk. 846.00
stone-chips (having LAA value <= 30%, water absorption not greater than 2%, flakiness
index not greater than 35) of gradation as specified @ 0.68 cum of stonechips mixed with
46 kg of heated bitumen of 60/70 penetration grade heated straight run bitumen satisfying
the requirements of ASTM/AASHTO. Bitumen content % by wt. of total is 4.5% to 5.50%
or as determined by job mix design. The bitumen and stone-chips shall be separately
heated to a temperature of 140°C – 155°C and 150°C – 170°C respectively before
mixing. The mixing shall be done at temperature between 140°C – 160°C at a separate
place away from the fire. The bitumen and stone-chips mixture shall be laid uniformly over
10 sqm of surface in proper camber, grade and super-elevation only on the prepared and
accepted base or surface in a single appropriate layer to give the specified compacted
thickness. The mixture should be rolled with appropriate steel drum roller (3-5 tons) &
pneumatic multiple tire roller (8-10 tons) to full compaction. The rolling temperature shall
be maintained not below 90°C including supplying of all materials, their carriage,
labourers, tools and equipment etc. all complete as per direction of the Engineer-incharge.
(In order to achieve the specified grading a blending of nominal maximum size of
20 mm, 12 mm crushed stone chips and stone dust is suggested and proportion will have
to be determined by the laboratory analysis).
122
24.13 25 mm thick compacted pre-mixed bituminous carpeting with 12 mm down graded sqm Tk. 437.00
stone-chips (having LAA value <= 30%, water absorption not greater than 2%, flakiness
index not greater than 35) of gradation as specified @ 0.34 cum of stone chips mixed with
23 kg heated bitumen of 60/70 penetration grade heated straight run bitumen satisfying
the requirements of ASTM/AASHTO. Bitumen content % by wt. of total is 4.5% to 5.50%
or as determined by job mix design. The bitumen and stone-chips shall be separately
heated to a temperature of 140°C – 155°C and 150°C – 170°C respectively before
mixing. The mixing shall be done at temperature between 140°C – 160°C at a separate
place away from the fire. The bitumen and stone-chips mixture shall be laid uniformly over
10 sqm of surface in proper camber, grade and super-elevation only on the prepared and
accepted base or surface in a single appropriate layer to give the specified compacted
thickness. The mixture should be rolled with appropriate steel drum roller (3-5 tons) &
pneumatic multiple tire roller (8-10 tons) to full compaction. The rolling temperature shall
be maintained not below 90°C including supplying of all materials, their carriage,
labourers, tools and equipment etc. all complete as per direction of the Engineer-incharge.
(In order to achieve the specified grading a blending of nominal maximum size of
20 mm, 12 mm crushed stone chips and stone dust is suggested and proportion will have
to be determined by the laboratory analysis).
24.14 38 mm thick compacted pre-mixed dense bituminous carpeting with 20 mm down sqm Tk. 731.00
graded stone-chips (having LAA value <= 30%, water absorption not greater than 2%,
flakiness index not greater than 35) of gradation as specified @ 0.56 cum of stone chips
mixed with 45 kg heated bitumen of 60/70 penetration grade heated straight run bitumen
satisfying the requirements of ASTM/ AASHTO. Bitumen content % by wt. of total is 4.5%
to 5.50% or as determined by job mix design. The bitumen and stone-chips shall be
separately heated to a temperature of 140°C – 155°C and 150°C – 170°C respectively
before mixing. The mixing shall be done at temperature between 140°C – 160°C at a
separate place away from the fire. The bitumen and stone-chips mixture shall be laid
uniformly over 10 sqm of surface in proper camber, grade and super-elevation only on the
prepared and accepted base or surface in a single appropriate layer to give the specified
compacted thickness. The mixture should be rolled with appropriate steel drum roller (3-5
tons) & pneumatic multiple tire roller (8-10 tons) to full compaction. The rolling
temperature
shall be maintained not below 90°C including supplying of all materials, their carriage,
labourers, tools and equipment etc. all complete as per direction of the Engineer-incharge.
(In order to achieve the specified grading a blending of nominal maximum size of
20 mm, 12 mm crushed stone chips and stone dust is suggested and proportion will have
123
24.16 Providing and laying pre-mixed dense bituminous carpeting with hot mix plant using sqm Tk. 19,555.00
coarse aggregate, fine aggregate, filler and bituminous binder as per design Job Mix
Formula conforming Marshall Method as per specification, LAA value of aggregate should
be <=30%, water absorption not >2%, flakiness index not >35 mixed with 60/70
penetration grade straight run bitumen satisfying the requirements of ASTM/AASHTO.
including screening, cleaning of chips and preparing a uniform and quality mix in hot
mix plant and ensuring a homogenous mix, in which all particles of the mineral aggregates
are coated uniformly, carrying the hot premixed materials by means of dump/tipper truck,
spreading the mixed materials at specified laying temperature with a hydrostatic paver
finisher with sensor control to the required grade, level and alignment over the prepared
surface, tamping and finishing the mix at specified compacted thickness, maintaining
specified camber, grade, super-elevation and cross section, through rolling with
appropriate steel drum roller & pneumatic multiple tire roller (8-10 tons) to full compaction,
for break down, inter - mediate and finished rolling to achieve the desired density of at
least 98% of that of Laboratory Marshall specimen, hand packing and pinning to give an
even surface, including cost of all materials, their carriages, hire charges of hot mix plant
and all other machines, equipments for construction and quality control as per
specification, fuels, lubricants and wages of operational staff etc. all complete as per the
direction of the Engineer-in-charge. (Carpeting work by using asphalt plant is
mandatory for all divisional headquarter & capital city)
24.17 Providing tack coat @ 7.50 kg of bitumen (60/70 penetration grade) per 10 sqm including sqm Tk. 71.00
heating bitumen up to 175°C to 185°C etc. all complete (cost of bitumen included) and
accepted by the Engineer-in-charge.
24.18.1 Providing seal coat with 4 cft of Sylhet sand (FM 2.2) mixed with @ 7.32 kg of bitumen sqm Tk. 108.00
(60/70 penetration grade) per 10 sqm of road surface including supplying and spreading of
dry sand (F.M. 0.80) @ 0.09 cum per 10 sqm, including heating bitumen upto 176°C to
190°C, and spreading, rolling at a temperature not below 90°C celsius with appropriate
steel drum roller (3 -5 ton) and pneumatic multiple tire roller (8-10 tons) to the desired
compaction etc. all complete (cost of bitumen included ) and accepted by the Engineer-
incharge.
124
24.19.1 Providing prime coat @ 1.2 liter/sqm with cutback bitumen to be prepared by cutting back sqm Tk. 99.00
60/70 penetration grade bitumen in the ratio of 100 parts by volume of bitumen to 40-60
parts by volume of kerosene depending on the porosity of surface and will be decided by
field trials, carefully cleaning of the surface of base material to be primed and spraying
cutback bitumen at a temperature from 100 degree celcius to 120 degree celcius by
appropriate hand device etc.all complete as per direction of the Engineer-in-charge
24.19.2 Providing prime coat @1.2 liter/sqm with cutback bitumen to be prepared by cutting back sqm Tk. 101.00
60/70 penetration grade bitumen in the ratio of 100 parts by volume of bitumen to 40-60
parts by volume of kerosene depending on the porosity of surface and will be decided by
field trials, carefully cleaning of the surface of base material to be primed and spraying
cutback bitumen at a temperature from 100°C to 120°C by mechanical distributor etc.
all complete as per direction of the Engineer-in-charge.
24.2 Providing painting at the top of the road surface as road marking in two coats with sqm Tk. 287.00
approved best quality and colour of synthetic paint from authorized local agent of the
manufacturer in a sealed container having high water resistance, high bondability &
flexibility, using specific brand thinner applied by brass/ roller or others over a coat of
priming, providing elapsing time for drying including surface cleaning from dust, oil or dirt,
smoothening, finishing necessary tools etc. all complete & approved and accepted by the
Engineer-in-charge.
24.21 Providing expansion joints across the R.C.C. road pavement with 20 mm gap between meter Tk. 390.00
the adjacent panels. Supplying dowel bars of size 12 mm dia and 600 mm long M.S rod
placed @ 750 mm c/c. 300 mm of the bar being fixed within one slab keeping remaining
portion the bar free within the adjacent slab being inserted in 20 mm dia and 300 mm long
P.V.C. pipe embedded in the slab, inside of pipe fully greased, filling the gap between the
slabs (with admixture) of hot bitumen and coarse sand (F.M. 2.2) in proportion of 2:1,
finishing the top with bitumen, spreading coarse sand over the joint, all complete as per
plan, drawing and accepted by the Engineer-in-charge
DIVISION 25 : ARBORICULTURE WORKS
25.1 Labour charge for scraping lawn surface up to 38 mm depth by spade, picking up all sqm Tk. 9.00
sorts of brick bats, rubbish by suitable tools, removing the same by head load or by any
other means and stacking the same to a safe distance beyond 300 m including supply of
tools and plants etc. all complete and accepted by the Engineer-in-charge.
25.2 Preparation of ground to make ready for plantation by spading the ground in to a depth of sqm Tk. 20.00
150 mm to 230 mm beyond 38 mm thick scrapped ground by spade, breaking earth clods to
powder by hammers, picking up all sorts of rubbish, unwanted grasses by suitable tools,
carrying and spreading the surplus earth into low lying area including supply of tools and
plants etc. all complete and accepted by the Engineer-in-charge.
25.3 Leveling and dressing of lawn area to proper slope and grade by spading the same up to sqm Tk. 6.00
150 mm including supplying tools and plants etc. all complete and accepted by the Engineer-
in-charge.
25.4 Supplying of best and approved quality alluvial loamy silty soil including loading, cum Tk. 843.00
unloading at both ends, properly stacking at site including supply of tools and plants etc. all
complete and accepted by the Engineer-in-charge.
25.5 Supplying well decomposed cow dung carried by trucks or any other means including cum Tk. 1,507.00
loading, unloading at both ends, stacking the same at site including supply of tools and
plants etc. all complete and accepted by the Engineer-in-charge.
125
25.10.0 Supplying and providing, fitting, fixing bamboo jafry fencing by best quality muli bamboo sqm Tk. 505.00
split 20 mm in size having 75 mm x 75 mm mesh placed horizontally and diagonally doing
25 mm framing a square shape in both ways and both sides tightened with G.I wire fitted
with Borrak bamboo post of 100 mm dia and placed firmly in position at 1800 mm apart
including supply of tools and plants, digging hole and filling back etc. all complete and
accepted by the Engineer-in-charge.
25.11 Supplying and providing, fitting, fixing muli bamboo tree guard 1200 mm long and 500 each Tk. 647.00
mm dia fixing with best quality muli bamboo split 20 mm in size having 75 mm x 75 mm a
square holes with 2 mm wide bamboo splits strengthen with 4 Nos. 20 mm wide bamboo
split in both sides tightened with G.I wire fitted with 3 Nos. 63 mm dia borrak bamboo post
of 1800 mm long of which 600 mm will be driven into earth by digging hole followed by fill
back including supply of tools and plants all complete as per direction of engineer-in-charge.
25.12 Earth work in excavation to make a pit of 600 x 600 x 450 mm (depth) for plantation, each Tk. 137.00
applying cow dung mixing with loamy silty soil and excavated earth, planting the plants,
tightened with 1800 mm long borrak bamboo post with jute rope including supply of tools
and plants all complete and accepted by the Engineer-in-charge.
25.13 Spading for preparation of flower beds in pits up to 600 mm depth, re-molding, picking sqm Tk. 465.00
up and placing and removing the spaded earth to a safe distance, mixing @ 1 cft well
decomposed cow dung with 20% loamy silty soil and 6 cft excavated soil and fill back the
pit including supply of tools and plants all complete and accepted by the Engineer-in-charge.
25.14 Preparation of hedge beds by excavation of earth up to 300 mm depth filling up the bed sqm Tk. 234.00
by a mixture of cow dung, loamy silty soil, cutted earth @ 1 cft cow dung manure per 6 cft
of cutted earth and 20% loamy silty soil including supply of tools and plant etc. all complete
and accepted by the Engineer-in-charge.
25.15 Carrying of rubbish, taking up all sorts of bricks, brick-bats and rubbish gravel chips, cum Tk. 146.00
loading and unloading at both ends including supply of tools and plants etc. all complete and
accepted by the Engineer-in-charge.
25.16 Supply and carrying of 12.20 m long 100 mm dia borrak bamboo at site, loading and each Tk. 476.00
unloading at both end stacking the same at site including supply of tools and plants etc. all
complete and accepted by the Engineer-in-charge.
25.17 Supply and carrying of 7.62 m long 50 mm to 62.5 mm dia muli bamboo at site, loading each Tk. 261.00
and unloading at both end stacking the same at site including supply of tools and plants etc.
all complete and accepted by the Engineer-in-charge.
25.18 Supply and carrying of 4.5 h.p. 550 mm blade 4 stroke, finger trip 3 position height each Tk. 54,335.00
adjuster 200 mm x 38 mm star tread wheels grass cutting (power lawn mower machine):
YARDMAN No. 060A
126
26.1 Supplying, fitting and fixing European type glazed porcelain commode "S" type 465 x
340 x 415 mm in size, approximately 14 kg by weight, plastic seat cover and preparing the
base with cement concrete and with wire mesh or rods, if necessary, in all floors including
making holes wherever required and mending good the damages and fitting, fixing finishing
etc. complete with all necessary fittings and connection approved and accepted by the
Engineer-in-charge.
26.1.1 White each Tk. 3,158.00
26.1.2 Coloured each Tk. 3,255.00
26.1.3 Special Coloured each Tk. 3,424.00
26.2 Supplying, fitting and fixing European type glazed porcelain low-down, capacity 10 liter,
490 x 190 x 350 mm in size, approximately 14 kg by weight, on walls by screws and F.I. bar
clamps, rowel plugs, making holes wherever required and mending good the damages and
fitting, fixing finishing etc. complete with all necessary fittings and connection approved and
accepted by the Engineer-in-charge.
26.2.1 White each Tk. 2,228.00
26.2.2 Coloured each Tk. 2,409.00
26.2.3 Special Coloured each Tk. 2,650.00
26.3 Supplying, fitting and fixing of European type glazed porcelain combi closet, including
plastic seat cover, cistern system, preparing the base with cement concrete and with
wire mesh or rods if necessary, in all floors including making holes wherever required and
mending good the damages and fitting, fixing, finishing etc. complete with all necessary
fittings and connections approved and accepted by the Engineer- in- charge
26.3.1 670 mm x 365 mm x 755 mm, 31.0 kg
26.3.1.1 Light Colored (Ivory/ Alpine White/ Grey/ Pink/ Blue/ Aqua Verde) each Tk. 8,320.00
26.3.1.2 Coloured (Marble Shaded) each Tk. 10,505.00
26.3.1.3 Special coloured (Deep Blue/ Ruby/ Rain Forest/ Green) each Tk. 11,966.00
26.3.2 700 mm x 370 mm x 795 mm, 32.5kg
26.3.2.1 Light Colored (Ivory/ Alpine White/ Grey/ Pink/ Blue/ Aqua Verde) each Tk. 9,636.00
26.3.2.2 Coloured (Marble Shaded) each Tk. 12,220.00
26.3.2.3 Special coloured (Deep Blue/ Ruby/ Rain Forest/ Green) each Tk. 13,941.00
26.3.3 700 mm x 360 mm x 785 mm, 38 kg
26.3.3.1 Light Colored (Ivory/ Alpine White/ Grey/ Pink/ Blue/ Aqua Verde) each Tk. 13,041.00
26.3.3.2 Coloured (Marble Shaded) each Tk. 17,853.00
26.3.3.3 Special coloured (Deep Blue/ Ruby/ Rain Forest/ Green) each Tk. 19,048.00
26.3.4 Supplying, fitting and fixing of European type glazed porcelain combi closet of white each Tk. 15,305.00
or ivory color and size of approx. 340 mm x 730 mm x 785 mm, 36.75 kg of weight
including plastic seat cover with soft closing, cistern system, water consumption 6 litter,
siphon jet flushing system, mending good the damages and fitting, fixing, finishing etc.
complete with all necessary fittings and connection approved and accepted by the
Engineer- in- charge.
26.4 Supplying, fitting and fixing of European type glazed combi closet, 725 mm x 360 mm x
840 mm size, 42.7 kg of weight, including plastic seat cover, cistern system, preparing the
base with cement concrete and with wire mesh or rods if necessary, in all floors including
making holes wherever required and mending good the damages and fitting, fixing,
finishing complete with all necessary fittings and connections approved and accepted by
the Engineer- in- charge
26.4.1 725 mm x 360 mm x 840 mm size, 42.7 kg
127
26.8 Supplying 280x140 x 30 mm size glazed porcelain foot rest, 1.5 kg by weight including each Tk. 328.00
fitting, fixing in position with cement mortar (1:4) if necessary in all floors including making
holes wherever required and mending good the damages and fitting, fixing, finishing etc.
complete with all necessary fittings and connection approved and accepted by the Engineer-
in-charge.
26.9 Supplying, fitting and fixing white glazed vitreous W/H Wash Basin including excluding
pedastal fitting, fixing the same in position with heavy type C.I. Brackets. 30 mm dia PVC
waste water pipe with brass coupling (not exceeding 750 mm in length), basin waste with
chain plug including making holes in walls and floors and fitting with wooden blocks,
screws and mending good the damages, finishing etc. all complete approved and accepted
by the Engineer-in-charge.
26.9.1 600 mm x 465 mm x 225 mm in size ,14kg of weight
26.9.1.1 White each Tk. 2,687.00
26.9.1.2 Coloured each Tk. 2,929.00
26.9.1.3 Special Coloured each Tk. 3,050.00
26.9.2 595 mm x 430 mm x190 mm, 10kg of weight
26.9.2.1 White each Tk. 2,308.00
26.9.2.2 Coloured each Tk. 2,551.00
26.9.2.3 Special Coloured each Tk. 2,832.00
26.9.3 510 mm x 450 mm x 203 mm, 9.5kg of weight
26.9.3.1 White each Tk. 2,273.00
26.9.3.2 Coloured each Tk. 2,330.00
26.9.3.3 Special Coloured each Tk. 2,457.00
26.9.4 450 mm x 405 mm x180 mm, 7kg of weight
128
26.18 Supplying, fitting and fixing of 450 x 600 mm size and 5 mm thick unframed super each Tk. 886.00
quality mirror with hard boards at the back with all necessary fitting including making
holes in walls and mending good the damages with cement mortar (1:4) etc. all complete
approved and accepted by the Engineer- in- charge. (Made in Japan or equivalent)
26.19 Supplying, fitting and fixing of 450 x 350 mm size and 5 mm thick unframed super each Tk. 675.00
quality mirror with hard boards at the back with all necessary fitting including making
holes in walls and mending good the damages with cement mortar (1:4) etc. all complete
approved and accepted by the Engineer- in- charge. (Made in Japan or equivalent)
26.20 Supplying, fitting and fixing super quality 600 x 125 mm coloured glass (plate) shelf each Tk. 1,412.00
having 5 mm thickness with fancy C.P. brackets, screws and frames including making holes
in walls and mending good the damages with cement mortar (1:4) etc. all complete
approved and accepted by the Engineer- in- charge.
130
26.23 Supplying, fitting and fixing medium quality C.P. Towel rail of 600 mm long and 20 mm each Tk. 627.00
in dia with C.P. holder including making holes in walls and mending good the damages with
cement mortar (1:4) etc. all complete approved and accepted by the Engineer- in- charge.
26.24 Supplying, fitting and fixing of standard porcelain toilet paper holder of 150 mm x 150
mm x 126 mm size including making drills in walls and mending good the damages with
cement mortar (1:4) etc. all complete approved and accepted by the Engineer- in- charge
26.27.1 Surface mounted automatic liquid soap dispenser each Tk. 7,097.00
26.27.2 Wall-mounted automatic liquid soap dispenser each Tk. 7,700.00
26.27.3 Supplying, fitting and fixing of Liquid soap dispenser (push-up type) to dispense 16 oz each Tk. 1,060.00
(.47 liters) of soap, detergent or lotion. Unit shall be fabricated of tamper resistant, chrome
plated plastic, a translucent white polyethylene soap container, and a corrosion resistant
dispensing valve which can provide no more than 5 lbs (22.2 Newtons) pressure and unit
can be reloaded by unscrewing base from bracket collar, inverting unit, and unscrewing
soap container in which soap will continue to feed properly until empty with a continuously
visible soap level etc. all complete approved and accepted by the Engineer- in- charge.
26.28 Supplying, fitting and fixing of Stainless steel floor grating of following type
26.28.1 Supplying, fitting and fixing 125 mm dia stainless steel floor grating in traps or in drains each Tk. 257.00
including making holes in walls/floors and mending good the damages with cement mortar
(1:4) etc. all complete approved and accepted by the Engineer- in- charge.
131
26.30 Supplying, fitting and fixing of 125 mm dia convex cast iron grating on rain water down each Tk. 531.00
pipe (roof top) mending good the damages with cement morter (1:4) etc., all complete
approved and accepted by the Engineer- in- charge
26.31 Supplying, fitting and fixing of 100 mm inside diameter & wall thickness 2.7 mm - 3.4 mm meter Tk. 701.00
best quality uPVC rain water down pipe fitting, fixed in position with head and shoes,
bends, minimum20 mm width F.I. Bar clamp and nails, and including all accessories such
as round grating/domed roof grating, bands, sockets approved and accepted by the
Engineer- in- charge.
26.32 Supplying, laying, fitting and fixing of best quality HDPE soil, waste and ventilation pipe
having PE-100 (Hydrostatic Strength for PE-100 is 5.0 MPa & 12.4 Mpa at 80°c & 20°c
respectively according to ISO 4427:2007(E)), PN-6 (nominal pressure for PN-6 is 0.6 MPa
according to ISO 4427:2007(E) ) & SDR 26 for soil, waste and ventilation pressure pipe
having density 0.940 – 0.970 gm/cm3 and other physical, chemical, thermal, fire resistivity
properties etc. as per BSTI approved manufacturer standards or ASTM/BS/ISO/IS
standards ,fitted and fixed in position with necessary joints and fittings with all accesories
complete approved and accepted by the Engineer- in- charge.
26.35 Supplying 150 mm inside dia best quality uPVC soil, waste and ventilation pipe meter Tk. 1,075.00
having specific gravity 1.35 - 1.45, wall thickness 4.5 mm - 5.2 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or ASTM, BS/ISO/IS standards fitting and fixing in position with sockets, bends,
with all accessories such as Round grating/domed roof grating bands, sockets etc.
approved and accepted by the Engineer- in- charge.
133
26.36.2 20 mm dia G.I. pipe with wall thickness 2.65 mm, outside diameter min 25.3 mm, weight meter Tk. 336.00
1.7 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.3 25 mm dia G.I. pipe with wall thickness 3.35 mm, outside diameter min 31.7 mm, weight meter Tk. 424.00
2.59 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.4 32 mm dia G.I. pipe with wall thickness 3.25 mm, outside diameter min 38.5 mm, weight meter Tk. 529.00
3.33 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.5 40 mm dia G.I. pipe with wall thickness 3.25 mm, outside diameter min 46.5 mm, weight meter Tk. 669.00
3.83 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.6 50 mm dia G.I. pipe with wall thickness 3.65 mm, outside diameter min 57.3 mm, weight meter Tk. 860.00
5.38 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.7 62-65 mm dia G.I. pipe with wall thickness 3.25 mm, outside diameter min 71.5 mm, meter Tk. 1,340.00
weight 6.15 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.8 5 -80 mm dia G.I. pipe with wall thickness 3.25 mm, outside diameter min 86.5 mm, meter Tk. 1,526.00
weight 7.22 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.36.9 00 mm dia G.I. pipe with wall thickness 3.65 mm, outside diameter min 107.3 mm, meter Tk. 2,262.00
weight 10.42 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.37 Supplying different inside dia best quality uPVC pressure pipe for water supply having
specific gravity 1.35 - 1.45, and other physical, chemical, themal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards fitted
and fixed in position with sockets, bends, with all accessories such as Round
grating/domed roof grating, bends, sockets etc. approved and accepted by the Engineerin-
charge.
26.37.1 12 mm dia wall thickness 1.7 mm - 2.8 mm meter Tk. 102.00
26.37.2 19 mm dia wall thickness 1.9 mm - 2.9 mm meter Tk. 140.00
26.37.3 25 mm dia wall thickness 2.2 mm - 3.4 mm meter Tk. 164.00
26.37.4 32 mm dia wall thickness 2.7 mm - 3.6 mm meter Tk. 180.00
26.37.5 37 mm dia wall thickness 2.5 mm - 3.1 mm meter Tk. 157.00
26.37.6 60 mm dia wall thickness 3.0 mm - 3.9 mm meter Tk. 360.00
26.37.7 75 mm dia wall thickness 2.9 mm - 3.5 mm meter Tk. 449.00
26.37.8 88 mm dia wall thickness 3.5 mm - 4.1 mm meter Tk. 503.00
26.37.9 114 mm dia wall thickness 4.5 mm - 5.2 mm meter Tk. 615.00
26.38 Supplying different inside dia best quality CPVC pressure pipe for water supply having
specific gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/ISO/IS standards fitting
and fixing in position with sockets, bends, with all accessories such as round
grating/domed roof grating, bends, sockets etc. approved and accepted by the Engineerin-
charge (length: 6000 mm each).
26.45.2 00 mm dia with wall thickness 5.3 mm - 7.8 mm uPVC pipe meter Tk. 1,364.00
26.45.3 250 mm dia with wall thickness 6.6 mm - 7.6 mm uPVC pipe meter Tk. 1,947.00
26.45.4 280 mm dia with wall thickness 6.9 mm - 8.6 mm uPVC pipe meter Tk. 2,514.00
26.45.5 15 mm dia with wall thickness 7.8 mm - 9.0 mm uPVC pipe meter Tk. 2,553.00
26.46 Supplying, fitting and fixing of G.I. Union with sealant etc. complete in all respects
approved and accepted by the Engineer- in- charge.
26.46.1 12 mm dia G.I. Union each Tk. 125.00
26.47 Supplying, fitting and fixing of best quality G.I. gate valve with sealant etc. complete
approved and accepted by the Engineer- in- charge.
26.47.1 12 mm brass gate valve each Tk. 409.00
26.49 Supplying, fitting and fixing of best quality G.I. check valve, threaded joint with sealant
etc. complete approved and accepted by the Engineer- in- charge.
26.49.1 12 mm brass check valve each Tk. 300.00
26.5 Supplying, fitting and fixing of best quality G.I. float valve, threaded joint Pit valve etc.
complete approved and accepted by the Engineer- in- charge.
26.50.1 12 mm brass Float valve each Tk. 350.00
26.50.2 20 mm brass Float valve each Tk. 468.00
26.50.3 25 mm brass Float valve each Tk. 568.00
26.50.4 32 mm brass Float valve each Tk. 888.00
26.50.5 40 mm brass Float valve each Tk. 1,023.00
26.51 Supplying different inside dia best quality uPVC clean out / trap having specific gravity
1.35 -1.45 and other physical, chemical, themal, fire resistivity properties etc. as per BSTI
approved manufacturer standards or ASTM, BS/ISO/IS standards, fitting and fixing in
position etc. complete approved and accepted by the Engineer- in- charge.
26.51.1 50 mm dia uPVC Y or T - Y Cleanout each Tk. 546.00
26.51.2 100 mm dia uPVC „P‟ or „S‟ trap each Tk. 611.00
137
26.65 Supplying and fitting-fixing cleansing shower for ablution including holder etc. all
complete approved and accepted by the Engineer- in- charge.
26.77 Suppy, fitting and fixing of Water pressure reducing valve to reduce static and flowing
pressures in water distribution systems and it shall be a diaphragm/balanced piston type
26.77.1 withmm
12 integral stainless
dia water steelreducing
pressure strainer and a built-in bypass to relieve pressure build-up
valve each Tk. 2,384.00
26.78 Manufacturing, supplying, fitting & fixing of adjustable hanger made of 38 mm x 38 mm x meter Tk. 676.00
6 mm m.s. angle with 600 mm long 12 mm dia nut-bolt for having pvc pipe from ceiling as
26.79 per direction
Supplying, of theand
fitting Engineer-in-charge.
installation of automatic hand drier of high speed, energy efficient, each Tk. 6,094.00
rapid drying, automatic sensor, adjustable speed and sound control, adjustable heat
control, electric hand dryer; surface mounted or semi‐recessed which can eliminate over
99% of airborne bacteria and particles as small as 0.3 microns with the removable Super
Filter System and it shall be powered by 220v AC supply/ batteries and shall operate
automatically from IR sensor that shall activate it when hands are placed in sensor zone
etc. all complete accepted by the Engineer- in- charge.
INSPECTION PIT & SOAK WELL
26.80.0 Construction of masonry inspection pit with 250 mm thick brick work in cement mortar
(1:4) including necessary earth work, side filling and one layer brick flat soling, 75 mm
thick (1:3:6) base concrete for making invert channel and 12 mm thick (1:2) cement
plaster with neat finishing etc. all complete up to a depth of 700 mm approved and
accepted by the Engineer- in- charge.
26.80.1 Clear 450 mm x 450 mm and depth 450 mm to 600 mm, average 525 mm for single 150 each Tk. 3,530.00
mm dia R.C.C. pipes and 400 mm PVC pipe.
26.80.2 Clear 525 mm x 525 mm and depth 675 mm to 825 mm, average 750 mm for single 225 each Tk. 5,262.00
mm dia R.C.C. pipes and 400 mm PVC pipe.
26.80.3 Clear 600 x 600 mm and depth 750 mm to 900 mm, average 825 mm for single 300 mm each Tk. 7,321.00
dia R.C.C. pipes and 400 mm PVC pipe.
26.80.4 Master-pit of Size: Clear 600 mm x 500 mm and average 750 mm depth for Septic tank. each Tk. 3,825.00
26.81 Master-pit of Size: Clear 600 mm x 500 mm and average 750 mm depth for Septic tank.
26.82 Construction and placing of R.C.C inspection pit cover (slab) with supplying and
provisions for placing, fitting, fixing 450 mm dia C.I. man-hole cover with
locking/unlocking
arrangement including concrete (1:2:4) with approx. 1% re-enforcement,
necessary earth cutting, or cleaning, side filling, curing etc. with minimum 12 mm cement
plaster (1:4) and neat cement finishing on edges and top all complete and accepted by
the Engineer- in- charge.
26.82.1 950 mm x 950 mm x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. each Tk. 2,280.00
26.82.2 1025 mm x 1025 mm x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. each Tk. 2,443.00
26.82.3 1100 mm x 1100 mm x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. each Tk. 2,672.00
26.83 Construction of masonry inspection pits up to a depth of 700 mm with 250 mm thick
brick work in cement mortar (1:4) including 100 mm thick R.C.C. top slab (1:2:4) with 1%
26.83.1 reinforcement,
Clear 450 mm xman-hole
450 mmcover with 450
and depth locking
mmarrangement
to 600 mm, including necessary
average 525 mm forearth
singlework,
150 each Tk. 5,810.00
mm dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
26.83.2 cover.
Clear 525 mm x 525 mm and depth 675 mm to 825 mm, average 750 mm for single 225 each Tk. 7,705.00
mm dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
26.83.3 cover.
Clear 600 mm x 600 mm and depth 750 mm to 900 mm, average 825 mm for single 300 each Tk. 9,993.00
mm dia R.C.C. pipes and 375 mm and 400 mm PVC pipe with pit cover and 450 mm dia
26.84 C.I. man-holeofcover.
Construction septic tank of different sizes with walls of brick work in cement mortar
(1:6) having a lining of minimum 125 mm R.C.C cast against the walls as per approved
type plan over a brick flat soling and 150 mm thick reinforced cement concrete flooring
(1:2:4) with 125 mm thick walls in partition and 12 mm thick cement plaster (1:4) with
N.C.F. to insides of walls on floor and all around outside walls by 450 mm height at top
including supplying, fitting and fixing of two R.C.C. Tees and providing 450 mm dia water
sealed heavy type C.I. manhole cover with locking/unlocking arrangement and 100 mm
thick R.C.C (1:2:4) top slab, including centering, shuttering, fabricating, casting and curing
etc. complete up to required depth including necessary earth work in excavation and
shoring, bailing out water and side filling including the cost of all materials, operations and
incidental charges. etc. all complete as per type plan approved and accepted by the
Engineer-in-charge (Rate is including cost of reinforcement and its fabrication, binding
and placing).
26.84.1 For 200 users each Tk. 233,848.00
26.85 Construction of soak well of different sizes (medium and large sizes) with 250 mm thick
solid brick work and 250 mm honey comb brick work with cement mortar (1:6) as per
design over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as per drawing
with 450 mm dia water sealed heavy type. C.I. manhole cover with locking arrangement,
filling the well up to the required depth with graded khoa and sand including supplying and
fabricating M.S. rod, casting, curing including necessary earth work in excavation, side
filling and bailing out water including cost of all materials etc. all complete as per drawing,
design approved and accepted by the (Rate is including cost of reinforcement and its
fabrication, binding and placing) Engineer- in- charge.
141
26.86 Construction of soak well of different sizes (small sizes) with 250 mm thick solid brick
work and 250 mm honey comb brick work with cement mortar (1:6) as per design over
26.86.1 R.C.C.
20 to 30(1:2:4)
users well curb with 1% reinforcement up to the depth as per drawing with 450 each Tk. 54,765.00
26.87 Supplying, fitting, fixing of foreign made best quality Reverse Osmosis Water Purifier
(Kent / Unilever / Vapor water purifier or equivalent brand) for purification of water by
26.87.1 reversepurification
Water osmosis system to have
volume: potable
50 gallon water
/day conforming
water WHO standard and
reserve capacity each Tk. 12,920.00
26.87.2 Water purification volume: 75 gallon per day each Tk. 19,279.00
26.87.3 26.87.3 Water purification volume: 75 gallon per day (touch type) each Tk. 25,437.00
26.87.4 Water purification volume: 100 gallon per day (with hot, cold & warm option) each Tk. 69,418.00
26.87.5 Water purification volume: 200 gallon per day each Tk. 51,035.00
26.87.6 Water purification volume: 400 gallon per day each Tk. 75,546.00
26.88 Supply, installation and commissioning of 50 liter capacity best quality ‘Water dispenser’ each Tk. 4,468.00
with container of approved brand/origin.
26.89 Punching or cutting hole of any diameter for sanitary works each Tk. 325.00
142
Note: Tender for test & observation well must be called before hand. Tender for
main production well will then be called on the basis of required data obtained from
the test well. Requirements of water must be the guiding factor for dimensioning the
main well.
SINKING OF 38 mm DIA TEST AND OBSERVATION WELL
27.1 Mobilization for test boring or observation well: Transportation of materials, equipments, Per set Tk. 7,913.00
tools and plants and boring rig to work site. Construction of derrick and dismantling the
same. Cleaning the site after completion of the work accepted by the Engineer-in-charge.
27.2 Boring by using 100 mm dia cutter and 40 mm dia heavy type G.I pipe having wall
thickness 2.9 mm, outside diameter min 47.8 mm, weight 3.517 kg/m, capability to
withstand 50 kg/cm2 and other equipments capable of drilling up to a depth 500 meter by
water jet system through all sorts of strata. Protection of caving by supplying necessary
casing pipe. Collection of soil samples at every 3 meter interval and at every change of strata
and preserve them in a controlled environment for analysis and laboratory test. Finally
withdrawal of boring and casing pipes etc. complete and accepted by the Engineer-in-
charge.
27.2.1 From 0.0 m to 50 m = 50 m meter Tk. 191.00
27.3 Installation of tube-well fixture for observation well: Supplying and lowering of 40/38
mm inside dia best quality uPVC pressure tube well pipe having specific gravity 1.35 - 1.45,
wall thickness 2.5 mm - 3.0 mm, capability to withstand a minimum hydrostatic pressure of
170 psi for 1 hr. fitted and fixed in position with all accessories, uPVC sand trap of length
3.00m with uPVC strainer of desired slot installing in or at mid depth of the most suitable
water bearing strata. 38 mm dia G.I. pipe of best quality of length 1.52 m with M.S. welded
flat bar on each side to prevent from rotation up to desired depth, fitting fixing the best
quality No. 6 C.I. head hand-pump etc including the cost of solvent cement, socket adaptor,
filling medium sand up to 18.00 m above strainer and the remaining portion with available
soil from boring etc. complete as per standard specification and accepted by the Engineer-in-
charge.
27.3.1 Fitting & fixing of no. 6 Hand-pump set including all necessary accessories etc Per set Tk. 2,968.00
27.3.2 38/40 mm dia heavy type G.I pipe conforming to standard BS-1387 & BDS-1031, having meter Tk. 770.00
chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20 Sulphur 0.060 max,
Phosphorous 0.060 max, Tensile properties: minimum Yield Strength 188 Mpa, minimum
Tensile Strength 313 MPa and marking for a) Manufacturer b) Material c) Wall thickness d)
Nominal outside dia e) Intented use etc. on the body of the pipe having wall thickness 2.9
mm, weight 3.517 kg/m capability to withstand 50 kg/cm2 hydraulic pressure.
27.3.3 38/40 mm dia water grade uPVC pipe having wall thickness 2.5-3.00 mm meter Tk. 162.00
27.3.4 38/40 mm dia water grade uPVC strainer having thickness 2.5-3.00 mm meter Tk. 204.00
143
27.3.7 Supplying, fitting fixing observation well inside the housing pipe of the deep tube well: 100'- each Tk. 19,802.00
0" depth
27.3.8 Supplying, fitting & fixing tube-well log describing technical information of the tube-well each Tk. 4,105.00
27.3.9 Filling the top 0.6 meter of the bore hole around the top pipe with sanitary seal of 1:2:4 each Tk. 51.00
(Cement: 1.2 FM sand: 20 mm downgraded brick chips) concrete
27.4 Complete development of the tube well to obtain sand and turbidity free water at a
satisfactory yield confirmed by tests as per specification and accepted by the Engineer-
incharge.
Water sample must be taken from 3 separate aquifers from three tube-wells
27.4.1 Wells up to 200 meter depth
27.5.2 Furnishing design considering 2 Nos. test bore L.S. Tk. 72,930.00
27.5.3 Furnishing design considering 3 Nos. test bore L.S. Tk. 109,395.00
27.6 Disinfections of the well by using minimum 3 kg of bleaching powder of 33% strength or each Tk. 380.00
any other disinfectant as per standard specification and accepted by the Engineer.
PRODUCTION WELL
27.7 Mobilization: Preparation for installation of tube-well and transportation of complete
boring equipments, labour and materials to the work site and remove the materials after
completion of the works. Installation of drilling rig and accessories, making arrangements
for electricity, water, labour shed, site office and stores, digging mud pit etc, leveling,
dressing and clearing of the site as per original condition and a testing for discharge using
minimum 1000 liter water tub etc. all complete as per specifications and accepted by the
Engineer-in-charge.
27.7.1 For Tube-wells up to 100 meter depth Per set Tk. 39,232.00
27.7.2 For Tube-wells up to 200 meter depth Per set Tk. 42,034.00
27.7.3 For Tube-wells beyond 200 meter depth Per set Tk. 44,836.00
27.8 Preparation and making gravel pack around the tube well fixtures with supply of cum Tk. 4,725.00
designed graded pea gravels free from any substance harmful to pipe and health confirmed
by test (Passing through 10 mesh and retained on 40 mesh) including sieving, washing etc.
complete as per standard specification and accepted by the Engineer.
(The rate is inclusive of the cost of extra amount required for caving and extra depth below
the tube well fixtures, shrouding should not be more than 15 m above the strainer and
measurement should be allowed from bottom of the tube-well fixture to top of the gravel
pack)
145
27.10 Boring: Execution 325 mm dia of boring through all sorts of strata by reverse circulation or
any other approved method (Method other than reverse circulation is to be applied only for
wells deeper than 152 meter). Boring for 325 mm dia vertical hole up to designed depth and
collection of soil samples at every 3 meter interval or as required and at every change in soil
stratum including sinking and with drawing necessary casing pipe and all necessary
arrangements complete as per specification and accepted by the Engineer. (Measurement
will be allowed from E.G.L. to bottom of the blind pipe and the rate is inclusive of the cost
of extra depth or of further boring required due to caving and siltation)
27.11 Supplying the following tube well fixtures and pipes having density 1350 kg/m3, opacity
0.2% of visible light as per ISO 7686, minimum required strength 25 MPa conforming to
BDS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and accepted by the
Engineer-in-charge. Note : Pipe size (wall thickness) will be chosen as per table page no:
213)
27.11.1 Best quality 50 mm dia uPVC cap each Tk. 107.00
27.11.2.1 50 mm dia water grade uPVC blind pipe/sand trap of wall thickness 2.5 to 3.00 mm meter Tk. 163.00
27.11.2.2 50 mm dia strainer of any slot as per design made with grade uPVC pipe of wall thickness meter Tk. 192.00
2.5 to 3 mm
27.11.2.3 50 mm dia water grade (Class E) uPVC blind pipe/sand trap of wall thickness 3.9 mm to meter Tk. 255.00
4.5 mm
27.11.3.1 50 mm dia strainer of any slot as per design made with grade (Class C) uPVC pipe of wall meter Tk. 215.00
thickness 2.5 mm to 3 mm
27.11.3.2 50 mm dia strainer of any slot as per design made with grade (Class D) uPVC pipe of wall meter Tk. 244.00
thickness 3.1 mm to 3.7 mm
27.11.3.3 50 mm dia strainer of any slot as per design made with grade (Class E) uPVC pipe of wall meter Tk. 307.00
thickness 3.9 mm to 4.5 mm
27.11.4 Best quality 50 mm x 125 mm dia uPVC Reducer meter Tk. 691.00
27.11.5.1 125mm dia water grade (Class C) uPVC housing pipe of wall thickness 5.5 to 6.4mm meter Tk. 786.00
27.11.5.2 125mm dia water grade (Class D) uPVC housing pipe of wall thickness 7.3 to 8.4mm meter Tk. 977.00
27.11.5.3 125mm dia water grade (Class E) uPVC housing pipe of wall thickness 9.0 to 10.4mm meter Tk. 1,158.00
27.11.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design each Tk. 379.00
27.12 Complete installation of 50 mm dia uPVC tube well fixtures such as expanded top or meter Tk. 80.00
furnishing pipe, reducer, tube well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
with best quality PVC solution, iron screws and PVC tape, sockets and placing in position
with proper size M.S. centralizer @ 3.0 meter c/c in strainer portion including blind pipe
etc. complete as per standard practice and accepted by the Engineer-in-charge.
146
27.14 Pumping test of the well by designed turbine/submersible pump with supply of testing Per hour Tk. 760.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours including
yield drawn and recovery test etc. complete as per specification and accepted by
theEngineer-in-charge.
27.15 Disinfections of the well including supply of sufficient quantity of bleaching powder (33% each Tk. 1,244.00
strength) to obtain chlorinated water having 150 ppm free chlorine in the well complete as
per standard specification and accepted by the Engineer-in-charge.
27.16 Filling of the borehole around the tube well from top of the shrouding up to the bottom of meter Tk. 31.00
sanitary seal by withdrawn selected soil or local clay free from any substances harmful to
pipes and health as per standard specification and accepted by the Engineer-in-charge.
27.17 Protective top cover: Supplying and fitting fixing best quality 150 mm dia 4 mm thick MS. each Tk. 4,549.00
Pipe 1.0 m (3'-4") long one end blocked with 200 mm dia 4 mm thick M.S. plate and other
end minimum 300 mm (1'-0") embedded in sanitary seal for protection of uPVC Housing
Pipe as per standard specification and accepted by the Engineer-in-charge.
INSTALLATION OF 75 mm x 150 mm DIA SHROUDED
PRODUCTION WELL WITH PVC PIPE
27.18 Boring: Execution of 350 mm dia boring through all sorts of strata by reverse circulation or
any other approved method (Method other than reverse circulation is to be applied only for
wells deeper than 152 meter). Boring for 350 mm dia vertical hole up to designed depth
and collection of soil samples at every 3 meter interval or as required and at every change
in soil stratum including sinking and withdrawing necessary casing pipe and all necessary
arrangements complete as per specification and accepted by the Engineer-in-charge.
(Measurement will be allowed from E.G.L. to bottom of the blind pipe and the rate is
inclusive of the cost of extra depth or of further boring required due to caving and siltation)
27.19.2.1 75 mm dia water grade (Class C) uPVC blind pipe/sand trap of wall thickness 3.5 mm to meter Tk. 313.00
4.1 mm
27.19.2.2 75 mm dia water grade (Class D) uPVC blind pipe/sand trap of wall thickness 4.6 mm to meter Tk. 403.00
5.3 mm
27.19.2.3 75 mm dia water grade (Class E ) uPVC blind pipe/sand trap of wall thickness 5.7 mm to meter Tk. 878.00
6.6 mm
27.19.3.1 75 mm dia strainer of any slot as per design made with water grade (Class C) uPVC pipe meter Tk. 359.00
of wall thickness 3.5 to 4.1 mm
147
27.29 Complete development of the tube-well by air compressor and pump of suitable capacity
by alternate surging and pumping until satisfactory yield, sand free water and the turbidity
condition is reached using necessary quantity of calgon and conducting step draw down test
before and after the development as per specification and accepted by the Engineer-in-
charge.
(Development should be started within 24 hours of completion of shrouding)
27.29.1 Wells up to 200 m depth each Tk. 38,560.00
27.29.2 Wells beyond 200 m depth each Tk. 46,272.00
27.30 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 984.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours including
yield drawn and recovery test etc. complete as per specification and accepted by the
Engineer-in-charge.
27.31 Disinfections of the well including supply of sufficient quantity of bleaching powder (33% each Tk. 1,777.00
strength) chlorinated water having 150 ppm available free chlorine etc. complete as per
standard specification and accepted by the Engineer-in-charge.
27.32 Filling of the borehole around the tube-well from top of the shrouding up to the bottom of rm Tk. 42.00
sanitary seal by withdrawn selected soil or local clay free from any substances harmful to
pipes and health as per standard specification and accepted by the Engineer-in-charge.
27.33 Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm thick M.S. each Tk. 9,356.00
pipe. 1.0 m (3'-4") long one end blocked with 300 mm dia 4 mm thick M.S. plate and other
end minimum 300 (1'-0") embedded in sanitary seal for protection of uPVC Housing pipe as
per standard specification and accepted by the Engineer-in-charge.
INSTALLATION OF 150 mm x 200 mm DIA SHROUDED
PRODUCTION WELL WITH uPVC PIPE
149
27.35.2.2 50 mm dia water grade (Class D) uPVC blind pipe/ sand trap having wall thickness 8.8 meter Tk. 1,339.00
mm to 10.2 mm
27.35.2.3 150 mm dia water grade (Class E) uPVC blind pipe/ sand trap having wall thickness 10.8 meter Tk. 1,842.00
mm to 12.5 mm
27.35.3.1 150 mm dia strainer of any slot as per design made with water grade (Class C) uPVC pipe meter Tk. 1,196.00
of wall thickness 6.6 to 7.6 mm
27.35.3.2 150 mm dia strainer of any slot as per design made with water grade (Class D) uPVC pipe meter Tk. 1,397.00
of wall thickness 8.8 to 10.2 mm
27.35.3.3 150 mm dia strainer of any slot as per design made with water grade (Class E) uPVC pipe meter Tk. 1,900.00
of wall thickness 10.8 to 12.5 mm
27.35.4.1 Best quality 150 mm x 200 mm dia uPVC Reducer each Tk. 1,246.00
27.35.4.2 Best quality 150 mm x 250 mm dia uPVC Reducer each Tk. 1,488.00
27.35.5.1 200 mm dia water grade (Class C) uPVC housing pipe of wall thickness 7.8 mm to 9.0 mm meter Tk. 1,721.00
27.35.5.2 200 mm dia water grade (Class D) uPVC housing pipe of wall thickness 10.3 mm to 11.9 meter Tk. 2,295.00
mm
27.35.5.3 00 mm dia water grade (Class E) uPVC housing pipe of wall thickness12.6 mm to 14.8 meter Tk. 2,687.00
mm
27.35.5.4 250 mm dia water grade (Class C) uPVC housing pipe of wall thickness 9.7 mm to 11.2 meter Tk. 2,687.00
mm
27.35.5.5 250 mm dia water grade (Class D) uPVC housing pipe of wall thickness 12.8 mm to 14.8 meter Tk. 3,753.00
mm
27.35.5.6 250 mm dia water grade (Class E) uPVC housing pipe of wall thickness 15.7 mm to 18.1 meter Tk. 4,458.00
mm
27.35.6 Supplying of centralizer made with 12 mm dia M.S. rod of approved design meter Tk. 379.00
27.36 Complete installation of 150 mm dia uPVC tube-well fixtures such as expanded top meter Tk. 106.00
pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing with best
quality uPVC solution, iron screws and uPVC tape and placing in position with proper size
M.S. centralizer @ 3 meter c/c in strainer portion including blind pipe etc. complete as per
standard practice and accepted by the Engineer-in-charge.
150
27.41 Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm thick M.S. each Tk. 9,261.00
pipe 1.0 m (3'-4") long one end blocked with 300 dia 4 mm thick M.S. plate and other end
minimum 300 (1'-0") embedded in sanitary seal for protection of uPVC Housing pipe as per
standard specification and accepted by the Engineer-in-charge.
INSTALLATION OF 150 mm x 300 mm DIA SHROUDED
PRODUCTION WELL WITH G.I. PIPE
27.42 Boring: Execution of 600 mm dia boring through all sorts of strata by reverse circulation or
any other approved method (Method other than reverse circulation is to be applied only for
wells deeper than 152 meter) for boring 600 mm dia vertical hole up to designed depth
and collection of soil samples at every 3 meter interval and at every change of formation
including sinking and withdrawing necessary casing pipe and all necessary arrangements
complete as per specification and accepted by the Engineer-in-charge. (Measurement will
be allowed from G.L. to bottom of the blind pipe and the rate is inclusive of the cost of
extra depth of boring required for caving and siltation)
27.42.1 From 0.0 m to 50 m = 50 m meter Tk. 1,279.00
27.43.2 150 mm dia G.I. Pipe having wall thickness 5.4 mm, weight 21.2 kg/m can withstand 50 kg/ meter Tk. 3,509.00
cm2 hydraulic pressure for blind pipe/sand trap
27.43.3 150 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia M.S.
rod continuously.
27.43.3.1 Stainless steel strainer of continuous slot having weight 28.84 kg per meter. meter Tk. 16,003.00
151
27.43.4 150 mm x 300 mm dia M.S. reducer of minimum thickness of 6 mm. meter Tk. 2,850.00
27.43.5 300 mm dia 6 mm minimum thick M.S. housing pipe (Welded) each Tk. 6,772.00
27.43.6 300 mm dia 6 mm minimum thick M.S. housing pipe (Seamless) meter Tk. 9,249.00
27.43.7 Centralizer made with 12 mm dia M.S. rod of approved design. each Tk. 379.00
27.43.8 350 mm dia M.S. cap having 6 mm thick for housing pipe covering. each Tk. 2,275.00
27.44 Complete installation of 150 mm dia deep tube-well fixtures such as expanded top meter Tk. 461.00
pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing socket,
welding and additional welding with fibre and placing in position with proper size M.S.
centralizer @ 3 meter c/c in strainer portion including. blind pipe etc. complete as per
standard practice and accepted by the Engineer-in-charge.
27.45 Complete development of the tube well by suitable air compressor and pump of suitable
capacity by alternate surging and pumping until satisfactory yield, sand free water and the
turbidity condition is reached using necessary quantity of calgon and conducting step draw
down test before and after the development as per specification and accepted by the
Engineer-in-charge. (Development should be started within 24 hours of completion of
shrouding)
27.45.1 Wells up to 200 m depth each Tk. 46,104.00
27.46 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 1,153.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours including
yield drawn and recovery test etc. complete as per specification and accepted by the
Engineer-in-charge.
27.47 Disinfections of the well including supply of sufficient quantity of bleaching powder (33% each Tk. 2,177.00
strength) chlorinated water having 150 ppm available free chlorine etc. complete as per
standard specification and accepted by the Engineer-in-charge.
27.48 Filling of the borehole around the tube well from top of the shrouding up to the bottom of meter Tk. 57.00
sanitary seal by withdrawn selected soil or local clay free from any substances harmful to
pipes and health as per standard specification and accepted by the Engineer-in-charge.
INSTALLATION OF 200 mm x 400 mm DIA SHROUDED
PRODUCTION WELL WITH G.I. PIPE
27.49 Boring: Execution of 800 mm dia boring through all sorts of strata by reverse circulation or
any other approved method (Method other than reverse circulation is to be applied only
for wells deeper than 152 meter). For boring 800 mm dia vertical hole up to designed
depth and collection of soil samples at every 3 meter interval and at every change of
formation including sinking and withdrawing necessary casing pipe and all necessary
arrangements complete as per specification and accepted by the Engineer-in-charge.
(Measurement will be allowed form G.L. to bottom of the blind pipe and the rate is required
for caving and siltation)
27.50.1 200 mm dia M.S. cap 6mm thick for blind pipe/ sand strap each Tk. 1,747.00
27.50.2 200 mm dia 6 mm thick tube well pipe and blank G.I. pipe of wt. 33.45 kg per meter can meter Tk. 7,505.00
withstand minimum 700 psi hydraulic pressure.
27.50.3 200 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia M.S.
rod continuously.
27.50.3.1 200 mm dia stainless steel strainer of continuous slot having 38.36 kg per meter. meter Tk. 18,719.00
27.50.3.2 200 mm dia 2.5 mm thick stainless steel bridge type strainer meter Tk. 12,529.00
27.50.4 200 mm x 400 mm dia 6 mm thick M.S. reducer. meter Tk. 2,932.00
27.50.5 400 mm dia 6 mm thick M.S. housing pipe (Welded) each Tk. 10,536.00
27.50.6 400 mm dia 6 mm thick M.S. housing pipe (Seamless) meter Tk. 12,871.00
27.50.7 Centralizer made with 12 mm dia M.S. rod of approved design each Tk. 379.00
27.50.8 450 mm dia M.S. cap of 6 mm thick for housing pipe covering. each Tk. 490.00
27.51 Complete installation of 200 mm dia deep tube well fixtures such as expanded top pipes, meter Tk. 503.00
reducer, and tube well pipes, strainer, blind pipe. Pipe cap etc. Fitting and fixing socket,
welding and additional welding with fibre and placing in position with proper size M.S.
centralizer @ 3 meter c/c in strainer position including blind pipe etc. complete as per
standard practice and accepted by the Engineer-in-charge.
27.52 Complete development of the tube well by suitable air compressor and pump of suitable
capacity by alternate surging and pumping until satisfactory yield, sand free water and the
turbidity condition is reached using necessary quantity of calgon and conducting step draw
down test before and after the development as per specification and accepted by the
Engineer-in-charge. (Development should be started within 24 hours of completion of
shrouding).
27.52.1 Wells up to 200 m depth each Tk. 42,896.00
27.52.2 Wells beyond 200 m depth each Tk. 47,943.00
27.53 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 1,198.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours including
yield drawn and recovery test etc. complete as per specification and accepted by the
Engineer-in-charge.
27.54 Disinfections of the well including supply of sufficient quantity of bleaching powder (33% each Tk. 2,488.00
strength) chlorinated water having 150 ppm available free chlorine complete as per standard
specification and accepted by the Engineer-in-charge.
27.55 Filling of the borehole around the tube well from top of the shrouding up to the bottom of meter Tk. 57.00
sanitary seal by withdrawn selected soil or local clay free from any substances harmful to
pipes and health as per standard specification and accepted by the Engineer-in-charge.
INSTALLATION OF 50 mm x 150 mm DIA SHROUDED
PRODUCTION WELL WITH G.I. PIPE
153
27.57.3.2 50 mm dia 2.5 mm thick stainless steel bridge type strainer meter Tk. 6,283.00
27.57.5 150 mm dia 6 mm thick M.S. housing pipe (Welded). each Tk. 5,023.00
27.57.6 150 mm dia 6 mm thick M.S. housing pipe (Seamless). meter Tk. 4,419.00
27.57.7 Centralizer made with 12 mm dia M.S. rod of approved design. each Tk. 379.00
27.57.8 150 mm dia M.S. cap of 6 mm thick for housing pipe covering. each Tk. 1,795.00
27.58 Complete installation of 50 mm dia deep tube-well fixtures such as expanded top pipes, meter Tk. 461.00
reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing socket, welding
and additional welding with fibre and placing in position with proper size M.S.centralizer @
3 meter c/c in strainer portion including. blind pipe etc. complete as per standard practice
and accepted by the Engineer-in-charge.
27.59 Compete development of the tube well by suitable air compressor and pump of suitable
capacity by alternate surging and pumping until satisfactory yield, sand free water and the
turbidity condition is reached using necessary quantity of calgon and conducting step draw
down test before and after the development as per specification and accepted by the
Engineer-in-charge. (Development should be started within 24 hours of completion of
shrouding)
27.59.1 Wells up to 200 m depth each Tk. 23,272.00
27.59.2 Wells beyond 200 m depth each Tk. 26,375.00
27.60 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 962.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours including
yield drawn and recovery test etc. complete as per specification and accepted by the
Engineer-in-charge.
154
27.64.1 150 mm dia 6mm thick M.S. cap for blind pipe/ sand trap. each Tk. 1,357.00
27.64.2 75 mm dia 4.85 mm thick tube well pipe and blank G.I. pipe meter Tk. 883.00
27.64.3 75 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia M.S.
rod continuously.
27.64.3.1 75 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter. meter Tk. 8,411.00
27.64.3.2 75 mm dia 2.5 mm thick stainless steel bridge type strainer meter Tk. 8,411.00
27.64.4 75 mm x 150 mm dia 6 mm thick M.S. reducer. meter Tk. 1,099.00
27.64.5 150 mm dia 6 mm thick M.S. housing pipe (Welded) meter Tk. 5,023.00
27.64.6 150 mm dia 6 mm thick M.S. housing pipe (Seamless) meter Tk. 4,419.00
27.64.7 Centralizer made with 12 mm dia M.S. rod of approved design each Tk. 379.00
27.64.8 150 mm dia M.S. cap of 6 mm thick for housing pipe covering. meter Tk. 1,795.00
27.65 Complete installation of 75 mm dia deep tube-well fixtures such as expanded top pipes, meter Tk. 447.00
reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing socket, welding
and additional welding with fibre and placing in position with proper size M.S. centralizer
@ 3 meter c/c in strainer portion including blind pipe etc. complete as per standard practice
and accepted by the Engineer-in-charge.
155
27.71.1 Supplying 150 mm 6mm thick M.S. cap for blind pipe/ sand trap. each Tk. 1,362.00
27.71.2 Supplying 100 mm dia 6 mm thick tube well pipe and blank G.I. pipe meter Tk. 1,325.00
27.71.3 100 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia M.S.
rod continuously.
27.71.3.1 Supplying 100 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter. meter Tk. 7,256.00
27.71.3.2 Supplying 100 mm dia 2.5 mm thick stainless steel bridge type strainer meter Tk. 7,256.00
156
27.71.7 Supplying centralizer made with 12 mm dia M.S. rod of approved design each Tk. 227.00
27.71.8 Supplying 200 mm dia M.S. cap of 6 mm thick for housing pipe covering. each Tk. 2,320.00
27.72 Complete installation of 100 mm dia deep tube-well fixtures such as expanded top meter Tk. 503.00
pipes, reducer, and tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
socket, welding and additional welding with fibre and placing in position with proper size
M.S. centralizer @ 3 meter c/c in strainer portion including blind pipe etc. complete as per
standard practice and accepted by the Engineer-in-charge.
27.73 Complete development of the tube well by suitable air compressor and pump of suitable
capacity by alternate surging and pumping until satisfactory yield, sand free water and the
turbidity condition is reached using necessary quantity of calgon and conducting step draw
down test before and after the development as per specification and accepted by the
Engineer-in-charge.
(Development should be started within 24 hours of completion of shrouding)
27.73.1 Wells up to 200 m depth each Tk. 38,560.00
27.74 Pumping test of the well by designed turbine/submersible pump with supply of testing hour Tk. 1,086.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours including
yield drawn and recovery test etc. complete as per specification and accepted by the
Engineer-in-charge.
27.75 Disinfections of the well including supply of sufficient quantity of bleaching powder (33% each Tk. 1,777.00
strength) chlorinated water having 150 ppm available free chlorine etc. complete as per
standard specification and accepted by the Engineer-in-charge.
27.76 Filling of the borehole around the tube well from top of the shrouding up to the bottom of meter Tk. 43.00
sanitary seal by withdrawn selected soil or local clay free from any substances harmful to
pipes and health as per standard specification and accepted by the Engineer-in-charge.
INSTALLATION OF 40 MM DIA uPVC HAND TUBE WEL
27.77 Supplying and sinking 40 mm dia water grade uPVC tube well pipe having wall
thickness 2.5 mm to 3.0 mm including trial boring and with all necessary fittings as required
etc. all complete and accepted by the Engineer-in-charge.
28.1.1 75 mm N.D (88.90 mm O.D) M.S pipe, weight min 8.3 kg/m, standard test pressure 176 meter Tk. 1,768.00
kg/ m2, wall thickness min 11.29 mm
28.1.2 50 mm N.D. (60.30 mm O.D) M.S pipe, weight min 5.44 kg/m, standard test pressure 176 meter Tk. 1,198.00
kg/ m2, wall thickness min 3.91 mm
28.1.3 25 mm N.D. (33.40 mm O.D) M.S pipe weight min 2.50 kg/m, standard test pressure 50 meter Tk. 682.00
kg/ m2, wall thickness min 3.38 mm
28.1.4 20 mm N.D. (26.70 mm O.D) M.S pipe weight min 1.68 kg/m, standard test pressure 50 meter Tk. 522.00
kg/ m2, wall thickness min 2.87 mm
28.2 Back filling the trenches with sand (F.M 0.8) in 150 mm layer, compaction each layer up to cum Tk. 683.00
finished level as per standard practice and accepted by the Engineer-in-charge.
28.3 Providing Butt welded joints with pipes to Tees, Elbows, Saddles, end caps etc above or
below ground including. cutting and V-leveling in each end of the pipe, grinding by machine
etc. complete as per specification of Titas Gas T and D C Ltd. and accepted by the
28.3.1 Engineer-in-charge.
75 mm N.D (88.90 mm O.D) each Tk. 192.00
28.3.2 50 mm N.D (60.30 mm O.D) each Tk. 163.00
28.3.3 25.mm N.D (33.40 mm O.D) each Tk. 128.00
28.3.4 20 mm N.D (26.70 mm O.D) each Tk. 109.00
28.4 Supplying, fitting and fixing the following materials including carriage to the work site
from Titas Gas Store as per specification of Titas Gas (T and D) Co. Ltd. and accepted by
the Engineer-in-charge.
(Rate is excluding the cost of welding)
28.4.1 50 mm x 50 mm x 50 mm (N.D) Equal Tee each Tk. 303.00
28.4.2 50 mm x 50 mm x 25 mm (N.D) Reducing Tee each Tk. 337.00
28.4.3 25 mm x 25 mm x 25 mm (N.D) Equal Tee each Tk. 208.00
28.4.4 50 mm x 90º Elbow each Tk. 241.00
28.4.5 25 mm x 90º Elbow each Tk. 88.00
28.4.6 50 mm x 25 mm 45º Elbow each Tk. 116.00
28.4.7 50 mm x 20 mm Reducer. each Tk. 126.00
28.4.8 20 mm plug, Socket each Tk. 353.00
28.4.9 50mm 20 mm saddle each Tk. 275.00
28.4.10 50 mm dia End Cap each Tk. 103.00
28.4.11 25 mm dia End Cap each Tk. 72.00
28.5 Supplying, welding, fitting and fixing of different sizes Valve Tee/ Service Tee to connect
the pipe line with the Titas Gas Main pipe line etc. all complete in all respect as per
specification of Titas Gas T and D Co. Ltd. approved and accepted by the Engineer-in-
charge.
158
28.11 Installation of Domestic or Commercial House line for supplying Titas Gas including
supplying, fitting and fixing in position different dia best quality G.I. Pipe (NT or equivalent)
along with all necessary G.I. Fitting and accessories, cutting trenches, walls and floors etc.
and back filling the trenches, restoring walls and floors etc. all complete in all respect as per
specification of Titas Gas T and D Co. Ltd. and accepted by the Engineer-in-charge.
28.13 Testing and purging the house line properly as per specifications Titas Gas T and D Co. meter Tk. 20.00
Ltd. and accepted by the Engineer.
DIVISION 29 : TERMITE TREATMENT WORKS
29.1 Supplying anti-termite chemicals named DURS BAN 20 EC and mixing the same with sqm Tk. 287.00
pure water in required proportion (For DURSBAN 20 EC I Ltd. in 19 liters of pure water)
and spraying the emulsified mixture @ 5 liters per square meter of soil surface by chemical
sprayer or by any other means to the sides and bottom of the foundation trench and over
plinth filling or floor bed accepted by the Engineer-in-charge.
29.2 Extra cost for supplying anti termite chemicals named DURS BAN 20 EC and mixing cum Tk. 2,113.00
the same with pure water as per specification in item No. 1 and using the same emulsified
water as mixing water in cement-sand mortar of brick works in foundation and up to plinth
and accepted by the Engineer-in-charge.
159
30.1.2 Add for each addl. floor up to 5th floor sqm Tk. 31.00
30.1.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 42.00
30.1.4 Add for each addl floor for 10th floor and above sqm Tk. 52.00
30.2 70 mm thick partition wall excluding plaster thickness with Concrete Hollow block having
compressive strength of 4.14~5N/mm2 of size (390 x 70 x 190) mm compliance with
ASTM C129, thickness of individual Block shell should not be less than 16 mm, water
absorption not more then 7 % lying with 8 to 10 mm thick mortar (with admixture) of
cement and sand in ratio 1:6 (sand not less than 1.2 F.M) filling the interstices with mortar
and making bond with connecting walls including necessary scaffolding and curing for min
3(three) days on mortar joints by jute/brush in wet, followed by impervious/wet covering for
another 4 (four) days etc all complete and accepted by the Engineer-in-charge.
30.17.1 Supplying and placing of 80 mm grey uni-block for paving heavy trafic areas, roads sqm Tk. 1,478.00
rounds abuts, industrial yards etc having compressive strength of 49 N/mm2 on
30.17.2 compactedand
Supplying sandplacing
bed ofof5080mm
mmonthick
stabilized soiluni-block
coloured base, and for
filling all interstices
paving with sand,
heavy trafic sqm Tk. 1,780.00
areas, road, industrial yard etc having compressive strength of 49 N/mm2 on compacted
30.18.1 sand bed ofand
Supplying 50 placing
mm on of stabilized
grey 200soil
mm base, andmm
x 100 filling
x 60allmm
interstices withblock
rectangular sand, having
cleaning sqm Tk. 1,258.00
compressive strength of 15 N/mm2 on 50 mm thick compacted sand bed, and filling all
interstices with sand, cleaning etc. accepted by the Engineer-in-charge
30.18.2 Supplying and placing of coloured 200 mm x 100 mm x 60 mm rectangular block sqm Tk. 1,443.00
having compressive strength of 15 N/mm2 on 50 mm thick compacted sand bed, and filling
all interstices with sand, cleaning etc. accepted by the Engineer-in-charge..
30.19.1 Supplying and placing of grey engraved cement concrete tiles (250 mm x 250 mm in
size) having minimum thickness of 24 mm over 12 mm sand cement mortar (4:1) each at
a distance of 6 mm apart and filling the joints with cement sand mortar (1:4) including
raking out joints and cutting the tiles to required sizes wherever necessary with high class
recessed pointing, cleaning and washing of sand, curing for minimun 3 (three) days on
mortar joints by jute /brush in wet, followed by impervious /wet covering for another 4
(four) days etc. all complete and accepted by the Engineer-in-charge.
30.19.1.1 Ground floor sqm Tk. 1,084.00
30.19.1.2 Add for each addl. floor up to 5th floor sqm Tk. 42.00
30.19.1.3 Add for each addl floor for 6th floor to 9th floor sqm Tk. 52.00
30.19.1.4 Add for each addl floor for 10th floor and above sqm Tk. 62.00
30.19.2 Supplying and placing of coloured engraved cement concrete tiles (250 mm x 250 mm
in size) having minimum thickness of 24 mm over 12 mm sand cement mortar (4:1) each
at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4) including
raking out joints and cutting the tiles to required sizes wherever necessary with high class
recessed pointing, cleaning and washing of sand, curing for min 3 (three) days on mortar
joints by jute /brush in wet, followed by impervious /wet covering for another 4 (four) days
etc. all complete and accepted by the Engineer-in-charge
31.2 Sub-soil investigation by 100 mm dia wash boring and / or by CPT, DCP etc.
including collecting disturbed and undisturbed soil samples in numbers as required for
classification of soil, conducting SPT, stratification of layers, analysing physical
parameters of soils like Atterberg limits, specific gravity, gain size distribution(by wet seive,
hydrometer if required) ,ground water table location, direct shear test, unconfined
compression test, unit weight(dry/weight), natural moisture content ; c - ф values and
other strength parameters to ascertain bearing capacity , skin friction, end bearings etc at
every 1.5m interval as per respective national/international standards and entering all
these data & information in necessary tables & graphs and finally furnishing them in the
form of standard sub-soil investigation report duly signed by competent engineer &
exploratory office.
31.2.3 Additional charge for bore hole depth above 30.0 m and upto 40.0 m meter Tk. 424.00
31.2.4 Additional charge for bore hole depth above 40.0 m and upto 50.0 m meter Tk. 448.00
31.3 Sub-soil investigation by 100 mm dia wash boring and/ or by CPT, DCP etc.including
collecting disturbed and undisturbed soil samples in numbers as required for classification
of soil, conducting SPT, stratification of layers, and entering all these data & information in
necessary tables & graphs, furnishing them in the form of standard sub-soil investigation
report duly signed by competent engineer & exploratory office.(Only after written advice
from concerned design division/circle)
31.3.3 Additional charge for bore hole depth above 30.0 m and upto 40.0 m meter Tk. 239.00
31.3.4 Additional charge for bore hole depth above 40.0 m and upto 50.0 m meter Tk. 255.00
31.4 Extra cost per bore hole, if the same is under water by more than 1.5 m in depth rm Tk. 5,089.00
31.5 Carrying out different tests on soil samples in BUET laboratory collected from the sub-soil
investigation site accepted by the Engineer-in-Charge. (Only after written advice from
concern design division/circle)
31.5.3 Permeability for cohesive soil per set of per set of Tk. 24,000.00
test test
31.5.4 Permeability non-cohesive soil per set of per set of Tk. 9,500.00
test test
31.5.5 Consolidation test for cohesive soil per set of per set of Tk. 22,000.00
test test
31.5.6 Triaxial shear Test
168
31.6.1 Per test rate for conducting additional plate load test at the same site after first 03(Three) per test Tk. 20,543.00
tests
31.62.2 Additional charge per km (beyond 25 Km) outside Dhaka city (two ways)/any city for per test Tk. 192.00
mobilization & demobilization
SCHEDULE OF RATE FOR REPAIR WORKS
FOR CIVIL WORKS
32.1 Stripping of unserviceable plaster in/c racking out joints, cleaning etc. Sqm Tk. 25.00
32.2.1 Picking-up of unserviceable patent stone from floor and dado etc. and removal of debris to Sqm Tk. 39.00
a safe distance
32.2.2 Picking-up of unserviceable tiles including bonding mortar from floor, walls and dado etc. Sqm Tk. 51.00
and removal of debris to a safe distance
32.3 Picking up of damaged/unserviceable terraced (lime concrete) floor or roof etc. and Sqm Tk. 53.00
removal of debris to a safe distance.
32.4 Dismantling of unserviceable/damaged terraced roof including beam, column, borga & tiles Sqm Tk. 138.00
etc. and removal of debris to a safe distance.
32.5.1.1 Dismantling of unserviceable/damaged brick works (with cement or lime mortar) of cum Tk. 434.00
thickness 250 mm in foundation and superstructure and removal of debris to a safe
distance
169
32.6.2 Dismantling of R.C.C. in roof slab and removal of debris to a safe distance. cum Tk. 2,790.00
32.6.3 Recovery of reinforcing bars and metals during dismantling of RCC including cleaning, quintal Tk. 442.00
making bundle, stacking or storing as per direction of engineer in charge and removal of
debris to a safe distance.
32.6.4 Recovery of bricks during dismantling of brick works including cleaning, stacking or storing % 0 nos. Tk. 1,275.00
etc. all complete as per direction of engineer in charge and removal of debris to a safe
distance.
32.6.5 Recovery of bricks during dismantling of soling including cleaning, stacking or storing all % 0 nos. Tk. 811.00
complete as per direction of engineer in charge and removal of debris to a safe distance.
32.6.6 Recovery of brick bats during dismantling soling, brick works, HBB etc. in/c cleaning, cum Tk. 213.00
stacking or storing as per direction of engineer in charge and removal of debris to a safe
distance.
32.7 Repairs to minor/fine (non-structural affecting aesthetic) cracks in brick walls, floor and meter Tk. 34.00
roof etc.
32.8.1 Cutting and polishing of old mosaic on wall with pumice stone etc. sqm Tk. 87.00
32.8.2 Cutting and polishing of old mosaic on floor with pumice stone and mosaic cutting machine sqm Tk. 79.00
etc.
32.8.3 Cleaning and washing the mosaic floor etc. sqm Tk. 17.00
32.8.4 Cleaning and refilling of wornout joints between glazed tiles, marble etc. in floor or walls sqm Tk. 64.00
32.9 Repairing of terraced roof cracks by cutting in 'traphozoided' shape meter Tk. 452.00
32.10.0 Taking out and relaying of old brick soling including replacement of 10% brick sqm Tk. 106.00
32.11 Taking out and relaying of brick soling after redressing the surfaces Sqm. Tk. 68.00
32.12.1 Taking out of old brick on edge pavement and resetting (Herring bone bond) including Sqm. Tk. 170.00
replacement of 10% brick
32.12.2 Taking out of old brick on edge pavement and restting Herring bone bond and redressing Sqm. Tk. 96.00
the surface
32.13 Taking out of old roof tiles and ridges Sqm. Tk. 59.00
170
32.16 Supplying and fitting-fixing of M.S. U-hook including nuts, washers each Tk. 60.00
32.17 Taking out of old & unserviceable wooden chowkat /door or window frame each Tk. 274.00
32.18 Taking out of old wooden chowkat/door or window frame and refitting and refixing after each Tk. 857.00
minor repair (excluding the cost of wood and M.S. clamp)
32.19 Taking out and refitting of wooden shutter after easing excluding the cost of wood sqm Tk. 408.00
32.20.1 Thorough repairs to wooden door and window Pannel shutter excluding the cost of wood Sqm. Tk. 669.00
32.20.2 Thorough repairs to wooden door and window Batten shutter excluding the cost of wood Sqm Tk. 620.00
32.20.3 Thorough repairs to wooden door and window Venetian shutter excluding the cost of wood Sqm Tk. 602.00
32.20.4 Thorough repairs to wooden door and window Glazed shutter excluding the cost of glass & Sqm Tk. 535.00
wood
32.21.1 Renewing of 3 mm glass panes in wooden frame including supply of glass Sqm Tk. 869.00
32.21.2 Renewing of 3 mm glass panes in steel frame including supply of glass Sqm Tk. 989.00
32.22 Renewing of 5 mm glass panes including supply of glass Sqm. Tk. 1,101.00
32.23 Cleaning and washing of glass panes including supply of necessary fresh putty, pins etc per pane Tk. 3.00
32.24.1 Replacing / renewing of fly proof wire net (with all new materials) the excluding cost of Sqm. Tk. 659.00
wood
32.24.2 Replacing / renewing of synthetic fly proof net (with all new materials) the excluding cost Sqm. Tk. 713.00
of wood
32.25 Renewing of fly proof wire netting (with old and new materials) the excluding cost of wood Sqm. Tk. 630.00
32.26 Renewing of 12 x 12 mm mesh wire netting the excluding cost of wood Sqm. Tk. 540.00
32.27 Taking out of hard board ceiling, walling Sqm. Tk. 18.00
32.28 Renewing of hard board ceiling or walling excluding cost of wood Sqm. Tk. 576.00
32.29 Replacing of wooden cleat, making, finishing and fixing with chowkat by means of 40 mm each Tk. 75.00
hinge
32.30.0 Replacing of cleat with brass hinge each Tk. 79.00
32.33.2 Replacing of 100 mm long galvanized iron catch hook each Tk. 16.00
32.33.3 Replacing of 150 mm long galvanized iron catch hook each Tk. 19.00
32.33.4 Replacing of 200 mm long galvanized iron catch hook each Tk. 21.00
32.33.5 Replacing of 225 mm long galvanized iron catch hook each Tk. 27.00
32.34 Replacing of iron socket bolt : 50 mm dia, 100 mm long each Tk. 26.00
32.35.1 Replacing of iron socket bolt : 50 mm dia, 100 mm long (SS) each Tk. 58.00
32.35.2 Replacing of iron socket bolt : 50 mm dia, 150 mm long each Tk. 31.00
32.35.3 Replacing of iron socket bolt : 50 mm dia, 150 mm long(SS) each Tk. 84.00
32.35.4 Replacing of iron socket bolt : 50 mm dia, 200 mm long each Tk. 45.00
171
32.36.1 Replacing of brass socket bolt: 50 mm dia, 150 mm long each Tk. 153.00
32.36.2 Replacing of brass socket bolt : 50 mm dia, 200 mm long each Tk. 192.00
32.36.3 Replacing of brass socket bolt : 50 mm dia, 250 mm long each Tk. 246.00
32.37.1 Replacing 75 mm long iron hinge. each Tk. 46.00
32.37.2 Replacing 100 mm long iron hinge. each Tk. 78.00
32.43.1 Renewing of Exterior standard acrylic emulsion paint of approved brand and quality sqm Tk. 132.00
32.43.2 Renewing of Exterior premium acrylic emulsion paint of approved brand and quality sqm Tk. 146.00
32.44.1 Renewing of standard synthetic enamel paint to door-windows frame and shutter:1coats sqm Tk. 96.00
32.44.2 Renewing of premium synthetic enamel paint to door-windows frame and shutter: 1coats sqm Tk. 100.00
32.45.1 Renewing of standard synthetic enamel paint to door-windows frame and shutter: 2 coat sqm Tk. 148.00
32.45.2 Renewing of premium synthetic enamel paint to door-windows frame and shutter: 2coat sqm Tk. 154.00
32.46.1 Renewing of synthetic polyvinyl distemper : 1 coats sqm Tk. 82.00
32.46.2 Renewing of synthetic polyvinyl distemper : 2 coat sqm Tk. 115.00
32.47.1 Renewing of Interior standard acrylic emulsion paint (Plastic) to walls and ceiling: 1 coat sqm Tk. 92.00
32.47.2 Renewing of Interior Premium acrylic emulsion painting (silky finish)to walls and ceiling: 1 sqm Tk. 108.00
coat
32.47.3 Renewing of Interior super premium acrylic emulsion painting (odorless) to walls and sqm Tk. 117.00
ceiling: 1 coat
32.48.1 Renewing of Interior standard acrylic emulsion paint (Plastic) to walls and ceiling: 2 coat sqm Tk. 130.00
32.48.2 Renewing of Interior Premium acrylic emulsion painting (silky finish)to walls and ceiling: 2 sqm Tk. 152.00
coat
32.48.3 Renewing of Interior super premium acrylic emulsion painting (odorless) to walls and Sqm. Tk. 135.00
ceiling 2 coat
32.49 Washing of painted wall surface with suitable soap or any other detergent Sqm. Tk. 30.00
32.50.1 Renewing of chlorinated rubber paint: 1 coats Sqm. Tk. 166.00
32.50.2 Renewing of chlorinated rubber paint: 2 coat Sqm. Tk. 221.00
32.51.1 Renewing of french polishing: 1 coats Sqm. Tk. 117.00
32.51.2 Renewing of french polishing: 2 coat Sqm. Tk. 183.00
32.51.3 Providing of 2 coats laqure spray painting with spray machine to high decorative Teak or Sqm. Tk. 147.00
similar wooden furniture
32.52.1 Renewing of painting with synthetic black enamel Paint to plinth and skirting :1 coats Sqm. Tk. 103.00
32.52.2 Renewing of painting with synthetic black enamel Paint to plinth and skirting :2 coat Sqm. Tk. 144.00
32.53 Renewing of painting to C.I. Roof with red corrugal paint: 2 coats Sqm. Tk. 142.00
32.54.1 Renewing earth oiling with solignum or equivalent materials: 1 coat Sqm. Tk. 80.00
32.54.2 Renewing earth oiling with solignum or equivalent materials: 2 coat Sqm. Tk. 119.00
32.55.1 Renewing of wood varnishing with varnish (yacht) Sqm. Tk. 103.00
32.55.2 Renewing of wood varnishing with varnish (egg-shell) Sqm. Tk. 103.00
172
32.71.24 Supply of Ripcord 400EC, 1 pics, 100 ml bottle Each. Tk. 241.00
32.71.25 Supply of Proclaim 5SG(emamectin benzoet) 1 box, (10 pack, each pack 10gm) Each. Tk. 724.00
32.71.26 Supply of Vertimec 018ECG (ebamectin) 1 pics, 50 ml bottle Each. Tk. 145.00
32.72.2 300 mm, 350 mm and 400 mm size tub Each. Tk. 27.00
173
32.74.1 Labour for picking-up and cleaning damaged bituminous road surface sqm Tk. 67.00
32.74.2 Repairing the potholes of the road by picking up and removing damaged materials with cum Tk. 24,489.00
stone chips
32.75 Applying necessary coat of bitumenous aluminium paint seal-coat on top surface of newly sqm Tk. 89.00
laid roofing felt
32.76.1 Supplying timber (unfinished) for repairing in wood works: Garjan/Jam/local Sal cum Tk. 85,282.00
32.76.2 Supplying timber (unfinished) for repairing in wood works: Jarul cum Tk. 76,754.00
32.76.3 Supplying timber (unfinished) for repairing in wood works: Shilkorai/Chickrashi cum Tk. 106,176.00
32.76.4 Supplying timber (unfinished) for repairing in wood works: Teak Chambal cum Tk. 144,979.00
32.76.5 Supplying timber (unfinished) for repairing in wood works: Chittagong Teak cum Tk. 187,194.00
32.76.6 Supplying timber (unfinished) for repairing in wood works: Kathal cum Tk. 95,942.00
32.76.7 Supplying timber (unfinished) for repairing in wood works: Gamari cum Tk. 72,490.00
32.76.8 Supplying timber (unfinished) for repairing in wood works: Chapalish cum Tk. 101,912.00
32.76.9 Supplying timber (unfinished) for repairing in wood works: Loha/Pyiankado cum Tk. 110,867.00
32.76.10 Supplying timber (unfinished) for repairing in wood works: Burma teak cum Tk. 277,166.00
32.76.11 Supplying timber (unfinished) for repairing in wood works: Ordinary timber (Mehogoni) cum Tk. 76,754.00
32.77 Labour charge for cleaning, washing, brooming from all heights and stacking of debris at a cum Tk. 1,256.00
place beyond plinth area of the the site during execution of repair works as per direction of
the engineer-in-charge
32.78 Cleaning, washing, brooming and taking away of debris from the site during and or after cum Tk. 716.00
the completion of the repair works in all heights by truck or by any other means as per
direction of the engineer-in-charge
32.79 Repairing of steel grill/window frame and shutter/stair railing, veranda grill, rolling shutter sqm Tk. 739.00
excluding the cost of steel materials.
32.80.0 Supply of steel materials for repairing work:
32.80.1 40-grade deform bar Kg. Tk. 70.00
32.80.2 60-grade deform bar Kg. Tk. 73.00
32.80.3 M.S. angle, T, and Z - section, Channel etc. Kg. Tk. 66.00
32.80.4 M.S. plain bar, F.I. Bar Kg. Tk. 66.00
32.80.5 M.S. sheet, plate used in repairing work Kg. Tk. 73.00
32.80.6 38 mm dia G.I. pipe used in repairing work meter Tk. 586.00
32.80.7 25 mm dia G.I. pipe used in repairing work meter Tk. 297.00
32.80.8 20 mm dia G.I. pipe used in repairing work meter Tk. 277.00
32.80.9 12 mm dia G.I. pipe used in repairing work meter Tk. 206.00
32.80.10 Spring for rolling shutter used in repairing work meter Tk. 59.00
32.80.11 Spring box for rolling shutter used in repairing work each Tk. 145.00
32.81 Cleaning and mending good the damages surrounding the mouth of spout/rain water down each Tk. 146.00
pipe
32.82 Cleaning rain water down pipe meter Tk. 5.00
174