High speed door operator operation instruction

1. This door machine must be installed and debugged by professional


installer.
2. Corresponding installation and wiring shall be in accordance with the
Construction Criteria, and wires diameter ≥ 1.5 mm2. Ensure the power
source has sound earth grinding, and the grinding wire shall tightly connect
into grounding plate. Cutting away the grinding lead wire is prohibited.
Earth leakage protection device fulfilling corresponding national criteria
shall be firmly set at the front end of the inlet power source.
3. This Industrial Door Machine is only applicable for door with sound
balance and Spring-Balanced, or the Machine would likely be destroyed by
overloading.
4. The door shall run freely and without any seizure wear. Each end of
the door rail shall have one restrictor or a buffer booster to avoid the door
slipping from the guide rail.
5. Control box shall be installed on wall or volume from where the door’s
operation condition can be visually observed, and with at least 1.4 meters
distance above floor level so that children could no longer touch it. For the
sake of children’s safety, remoter shall be kept away from kids. Operating
the door remoter at a place invisible of the door’s running condition is
prohibited.
6. Electricity supply system of both door-opening machine and control
box shall be cut off if maintenance and removal required. Door shall be
checked before maintenance and removal to ensure it is in lock-up
condition and there is no any sign of falling risk.
7. No any entrance or stay is allowed once the door is running.
8. Pulling the hand chain of this machine is prohibited when the door
machine is in operation, since it will easily damage the door.
9. For equipment with shift clutches, pulling ropes of the shift clutches is
prohibited unless otherwise the door is in definite close status; and no any
other conditions are allowed for rope drawing.
10. For the sake of safety of people and cars passing by, infrared safeguard
device and gasbag preventative devices shall be available.
1
High speed door operator operation instruction

Content

1.Parameter table Operator size…………………………… 3

2.High speed rolling door installation …………………… 4


3. Installation steps, The size of the fixed plate………………… 4~5
4. Circuit board structure, Motor connection port …… 6

5. Dial the code switch Settings,

Electronic limit connection, Mechanical limit connection 7

6. Control signal Control signal port …………… 8~9

7. Multi-functional port wiring instructions……… 10


8. Display Settings button and display symbols…………… 11
9. Limit the debugging and parameter Settings…………………… 12

1). Limit debugging steps ………………………… 12~13

2). P1 parameter debugging steps………………… 13~14

3) . P2 parameter debugging steps …………… 15~16

4). P3 parameter debugging steps ………………… 17~18

5).remote control set …………………………… 18

10.Circuit Board fault code the reason and solution …………… 19

11.Accessories list………………………………………… … 20

2
High speed door operator operation instruction

Parameter table
Type(3*AC220V) GYJ40 GYJ50 GYJ60 GYJ80 GYJ70 GYJ90
Rated Power 800W 1000W 800W 1000W 800W 1000W
Starting Torque 40N.m 50N.m 60N.m 80N.m 70N.m 90N.m
Reduction ratio 1:10 1:10 1:15 1:15 1:30 1:30
No-Load Rotating 135r 135r 90r 90r 45r 45r
Speed /min /min /min /min /min /min
Type of Lubricate Oil Immerged
Noise ≤60dB
Maxi Limiting Distance Using the absolute value encoder electronics
limited, output shaft to turn 20 laps
output shaft diameter Φ25.4mm
Use Environment -20℃ ~+45℃
Duty Cycle S1

Operator size

3
High speed door operator operation instruction

1. outer shell 2. fan 3. electromagnet 4. handle


5. terminal 6 rectifier 7. Encoder 8 reducer

High speed rolling door installation


Rapid rolling door can be installed directly on the soft roll door scrolls.
The installation diagram can be seen below,

1. Soft roll gate 2. Door pillar 3. side door fixed plate


4 Mounting bracket (optional) 5. Fast motor
6. Take the door of the slotting shaft 7. Key
8. fixed ring 9. Bolts and nuts

Installation steps

1. According to the desired location, on one side of the door to set

4
High speed door operator operation instruction

aside with slot installed shaft. Shaft out of about 180 mm

Door shaft diameter phi is 25 mm, keyway width of 8 mm.

2. In the side door on the fixed plate according to the mounting


bracket type slot hole of a waist to deserve to be 2 x phi 11 mm hole.

3. The combination of the mounting bracket with M10X16 screw fixed


in advance in output hole on the side of the machine.
4. In the gate shaft placed flat key, rapid rolling door, and mounting
bracket together set on axis of the door.

5. Use M10X25 bolt and nut the mounting bracket of M10 fixed plate
fixed side door.

The size of the fixed plate

5
High speed door operator operation instruction

Circuit board structure:(GYK-93S-2)

Motor connection port:


1, L N : AC 220 V power supply into line,
2, PE: Grounding.
3, U V W: Motor line, U (blue), V (brown), W (black) and
motor terminals U, V, W corresponding connection.

6
High speed door operator operation instruction
4, BN BL: Runtime output 220 v port, the electromagnet.

Dial the code switch Settings:

Electronic limit connection:

7
High speed door operator operation instruction

Mechanical limit connection:

8
High speed door operator operation instruction

Control signal Control signal port:

Multi-functional port wiring instructions:


1, Motor overheating protection:
9
High speed door operator operation instruction

Will lead to motor CO, CO symbols of two wires access control


box 1 (COM) and 2 (OH) port. When the motor temperature above
120 degrees, motor automatic stop working opportunity.
2, External three button function:Three button to switch to an
external access port 3 (OPEN), 4 (CLOSE), 5 (STOP) and 6 (COM)
port, switch state requirements for NO;
3, Middle limit function:
The external single push button switch two wires access 7 (EX)
and 6 (COM).Press the switch, the gate will automatically open to,
set in the middle of the limit position. Can be external fire signal, if
any signal input, doors automatically open to limit position in the
middle.
4, Step and step function:
The external single push button switch two wires access 8 (KEY)
and 6 (COM).Can achieve a single bond, open, stop, close, stop
cycle operation function.
5, DC24 v power supply output function:
Ports 9 and 10 to DC24 v power supply output port;
6, Infrared protection function:
The infrared signal equipment, access to 11 (INF) and 12 (COM),
24 v power cord access 9 (+ 24) and 10 (COM).. Enter the input
signal is NO, NC can be set up through parameter P2-09..
7, Air switch protection function:
Air switch signal equipment, access to 11 (INF) and 12 (COM),
24 v power cord access 9 (+ 24) and 10 (COM).. Enter the input
signal is NO, NC can be set up through parameter P2-09..

8,Radar automatic open door function :


To access the radar line 13 (RAD) and 12 (COM) port .NO or NC

10
High speed door operator operation instruction

state can be set through the P2-10, the function in the automatic
mode and effective;
9,Interlock function:
Port 14 (LK_I) and 15 (LK_O), for the interlock input and interlock
of the output signal interface, use the function of the interlock
function of P1-03 parameter must be set to open.
Interlock is the meaning of after putting in place a door closed,
another door to work

Multi-functional port wiring instructions:

Circuit board set


11
High speed door operator operation instruction

1, LEARN: Learn key or shift key


2, ENTER: Confirm key or function into the key
3, FWD: Rise key or increase key
4, REV : Down key 、Reduce key or transformation key
Normal working state, the screen will display open degree, manual
and automatic closed state, state of input. This state is called: "main
menu"
1, opening degree, according to screen data as the gates
open degree, data change between 0-100.
2, manual and automatic status display: (press REV more
than 3 seconds, manual and automatic mode)

3, Input status will display the current input signal digital code.

12
High speed door operator operation instruction

4 , Input signal status code:

Input state
Number instructions
1 stop
2 open
3 close
4 infra
5 radar
6 One key
7 Middle limit
8 interlock

Limit the debugging and parameter Settings:


1. Limit to learn
1) Long press LEARN more than 6 seconds,,L0 reads on LED,
2) press ENTER key, data feedback by the encoder can be read;
3 then keep holding down the FWD key (UP) until the door reaches the
desired location,
4) press ENTER key to save the settings. At this time, limit to learn is over;
5) when LED display reads L1 (that is the lower limit)
6) press the ENTER key to access the data feedback by the encoder,
7) keep holding down the REV key (falling) until the door falls to the
desired location.
8) and then press ENTER to save the settings;
9)Symbol "L2" appears on the screen at the same time, can press
FWD set limit, if you don't need to set up the middle spacing,
according to LEARN key to return to the main menu.
10)At this time, limit to learn is over.

13
High speed door operator operation instruction

2,P1 parameter Settings:


1), under the main menu, press ENTER more than 3 seconds, the
display shows P1,
2), and then press ENTER, the display digital box, ENTER the
password 1588.Now LEARN key for shift key (at this time, LEARN to
digital shift keys, mobile digital cursor to Single digits, ten digits, the
digits, thousand digits, and then with the FWD key respectively, REV
adjust up and down all the data on the digits)
3), press ENTER, show P1-01;(at this point by FWD key or REV key
can choose need to adjust the parameters of the up and down)
4), continue to press the ENTER key, ENTER the corresponding
parameter setting.
At this time more than hundred digit data adjustment need LEARN
shift key,;
More than ten digits data adjustment need only, long press FWD or
REV, data automatically rapid adjustment, loosen and then stop;
Bits of data adjustment, only need single press FWD or REV adjust up
and down.
5), other parameters adjustment method and so on, pay attention to,
after the completion of each parameter is set to press ENTER to save,
the press LEARN step by step after exit to the main menu, can start to
work normally.

14
High speed door operator operation instruction
6),P1 parameter name, scope, and the default value:
P1 parameter:password 1588
number instructions Parameter range default
value
P1—01 Open frequency 10—99Hz 70
P1—02 Close frequency 10—99Hz 35
P1—03 Buffer coefficient 2---10 7
P1—04 Closing time delay 1----600 10
P1—05 Torque increase 0-15 10
P1—06 speed up time 5—20 10
P1—07 Deceleration time 5----10 5
P1—08 Multifunctional 0=shut; 1=close; 0=shut
output 2=open;3=running;
4=wind curtain ;
5=alarm
P1—09 Open Point move 0= continuous move; 0
/continuous move 1= Point move
P1—10 Close Point move 0= continuous move; 0
/continuous move 1= Point move
P1—11 Interlock function 0=shut;1=open 0
P1—12 Limit up query Limit up setting data read-only
P1—13 Limit down query Limit down setting read-only
data)
P1—14 Middle limit query Middle limit setting read-only
data
P1—15 Point move 10—50Hz 12
frequency
P1—16 P1 parameter 1=restore 0
default recovery

15
High speed door operator operation instruction

3,P2 parameter Settings:


1), under the main menu, press ENTER more than 3 seconds, the
display shows P1,
2), And then press "FWD" key or "REV", (display data can switch
between P1, P2, P3).
3), Switch to the P2 parameters, and then press ENTER, the display
digital box, ENTER the password 1588.Now LEARN key for shift key
(at this time, LEARN to digital shift keys, mobile digital cursor to Single
digits, ten digits, the digits, thousand digits, and then with the FWD
key respectively, REV adjust up and down all the data on the digits)
4), press ENTER, show P1-01;(at this point by FWD key or REV key
can choose need to adjust the parameters of the up and down)
5), continue to press the ENTER key, ENTER the corresponding
parameter setting.
At this time more than hundred digit data adjustment need LEARN
shift key,;
More than ten digits data adjustment need only, long press FWD or
REV, data automatically rapid adjustment, loosen and then stop;
Bits of data adjustment, only need single press FWD or REV adjust up
and down.
6), other parameters adjustment method and so on, pay attention to,
after the completion of each parameter is set to press ENTER to save,
the press LEARN step by step after exit to the main menu, can start to
work normally.

16
High speed door operator operation instruction

7),P2 parameter name, scope, and the default value:


P2 parameter:password 8851
number instructions Parameter range default
value
P2—01 Limit mode 0=encoder;1= 0= encoder
mechanical
P2—02 Up limit advance 0—50 5
P2—03 Down limit advance 0—50 10
P2—04 Open Overshoot 10—200 100
alarm
P2—05 close Overshoot 10—200 100
alarm
P2—06 Infrared distance 1—800 500
P2—07 current coefficient 50%—110% 100%
P2—08 brake frequency 5-10 8
P2—09 Locked-rotor time 10-70 70
P2—10 Locked-rotor 0=shut 1=open 1
function
P2—11 Mechanical limit 5—15 5
buffer time
P2—12 Mechanical limit 0=(NO);1=(NC) 0=(NO)
level
P2—13 Stop level 0=(NO);1=(NC) 0=(NO)
P2—14 Infra level 0=(NO);1=(NC) 0=(NO)
P2—15 Radar level 0=(NO);1=(NC) 0=(NO)
P2—16 P2 parameter default 1=restore 0
recovery

17
High speed door operator operation instruction

4, P3 parameter Settings:
1), under the main menu, press ENTER more than 3 seconds, the
display shows P1,
2), And then press "FWD" key or "REV", (display data can switch
between P1, P2, P3).
3), Switch to the P3 parameters, and then press ENTER, the display
digital box, ENTER the password 00000. Now LEARN key for shift key
(at this time, LEARN to digital shift keys, mobile digital cursor to Single
digits, ten digits, the digits, thousand digits, and then with the FWD
key respectively, REV adjust up and down all the data on the digits)
4), press ENTER, show P3-01;(at this point by FWD key or REV key
can choose need to adjust the parameters of the up and down)
5), continue to press the ENTER key, ENTER the corresponding
parameter setting.
At this time more than hundred digit data adjustment need LEARN
shift key,;
More than ten digits data adjustment need only, long press FWD or
REV, data automatically rapid adjustment, loosen and then stop;
Bits of data adjustment, only need single press FWD or REV adjust up
and down.
6), other parameters adjustment method and so on, pay attention to,
after the completion of each parameter is set to press ENTER to save,
the press LEARN step by step after exit to the main menu, can start to
work normally.

18
High speed door operator operation instruction

7),P3 parameter name, scope, and the default value::


P3 parameter:password 00000
number instructions Parameter default value
range
P3—01 Change password 0—99999 00000
P3—02 Run time 0—99999 99999
Settings(days)
P3—03 Run number 0—99999 99999
Settings(number)
P3—04 View the total elapsed 0—99999 current time)
time (days)
P3—05 View the running 0—99999 Current
number number
P3—06 View the running 0—99999 Current
number (the number of number
more than ten
thousand shows)

4, the function of remote control Settings


Remote control receiving plate, installed on the screen of the socket
on the back of the circuit board, can plug, pay attention to the
direction of the insert, when installation should pay attention to in
rectangle area specified by the circuit board.
step1: after electrify hold the remote control receiver plate on white
button until the red light is extinguished, to remove the original
password;
step2: to press the white key learning, found that loosen the red
indicator into the learning state;

19
High speed door operator operation instruction

Step 3: Press any one transmitter, found that the red light is put out
after two flashes, end of the learning process

Circuit Board fault code the reason


and solution
error instructions The reason for the error analysis
code
ERR01 power supply Three-phase 380 v lack of L2 phase
lacks
ERR02 encoder not encoder cables
connected
ERR03 Limit anomaly Limit not set or limit beyond the set
value
ERR04 Electrical short Motor cables short circuit or power up
circuit too much
ERR05 Motor overload Motor current is more than set value
ERR06 More than life Reset run times or run number
ERR07 Motor blocked Lack of motor torque
(press ENTER reset)
ERR09 Motor heat Waiting for the motor cooling
protection
ERR10 Small door Check the wiring or Replace the
abnormal switch
ERR11 Frequency Inverter overheating protection
conversion
board
overheating

20
High speed door operator operation instruction

Packing list
Motor
number name quantity note
1 Motor 1 standard
2. Install the plate 1 standard
3. fixed ring 2 standard
4. Brake wrench 1 standard
5. key 1 standard
6. Hex bolt M10*20 4 standard
7. Cable 1 standard
4*0.75 4m
8 Shield cable 1 standard
4*0.3 4m
9 Cable 2*0.75 4m 1 standard
10 Shake the handle 1 standard
Electric control

1 Electric control 1 standard


2 Chassis key 2 standard
3 Remote control 1 optional

4 instructions 1 standard
21
High speed door operator operation instruction

22