CC-Link is an open industrial network that connects various automation components into a single integrated system. It guarantees high-speed communication of 10Mbps across all devices. CC-Link certified devices include PLCs, HMIs, drives, I/O modules, and intelligent devices from various manufacturers. This document provides a guide to CC-Link distributed I/O blocks and special function modules, explaining their model number nomenclature and connector types.

Uploaded by

Raul Gonzalez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views3 pages

CCLink Overview

CC-Link is an open industrial network that connects various automation components into a single integrated system. It guarantees high-speed communication of 10Mbps across all devices. CC-Link certified devices include PLCs, HMIs, drives, I/O modules, and intelligent devices from various manufacturers. This document provides a guide to CC-Link distributed I/O blocks and special function modules, explaining their model number nomenclature and connector types.

Uploaded by

Raul Gonzalez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CC-Link Overview

CC-Link

Q Series Supervisory PC
Automation
Platform
L Series PLC
iQ Platform Legacy
A/QnA Series Controller

E700 Series
AC Drives

GOT1000 HMI FX Series Micro PLC


3rd Party Intelligent Devices
Robot
EnergyPAQ

D75 Dual Axis


Motion
Controller

Remote Program
Interface Remote Modules:
I/O, Analog, High- Third Party Products:
Speed Controllers, Sensors, Valves, Etc.
RTD, Etc.
MR-J3/Motor
Laptop PC Servo Amp

ST Slice IO

Control and Communication Link (CC-Link) is an open network administered as a fully open architecture by the CC-Link Partner Association
(CLPA). Currently over 1000 products are CC-Link certified.

CC-Link guarantees a full 10Mbit/s performance across the whole network, regardless of device type, eliminating hidden bottle necks, common
with other open systems. CC-Link offers you the freedom to integrate a wide variety of automation components into a single, seamless
automation system, including any of the following items on the network:
• Master or local controllers (iQ-R, iQ-F, Q, L, FX)
• HMIs
• VFDs
• Discrete I/O (in a wide variety of types and configurations)
• Analog I/O
• High speed counters

Guide to CC-Link Dedicated I/O Blocks and Special Function Modules


This section presents the current line-up of CC-Link dedicated I/O blocks and special function modules. For network master modules, please
refer to the appropriate controller section. Before using this guide, please read the following guide to nomenclature:

Selection Guide Edition 18 • Revised January 1, 2018 Mitsubishi Electric Automation | DISTRIBUTED I/O 1
n DISTRIBUTED I/O
Guide to CC-Link Dedicated I/O Block Nomenclature • Generic Model Number Format

AJ65 BT -

Symbol Module Type External Load Symbol Device Type Symbol Sink or Source Symbol Special Features
Symbol
Connection Method
F Waterproof (IP67) A 120 VAC Sink (no symbol) Inputs 1 Fast switching inputs
1 1 wire type Inputs Inputs
S Compact type D 24 VDC E Source Outputs 1 Low leakage output current
2 2 wire type
V Vertical format R Relay Sink (no symbol) 1 Fast switching inputs
3 3 wire type Outputs
Outputs S Triac / SSR E Source Combination 2 Low leakage output current
Symbol Connector Type 4 4 wire type
T Transistor Sink (no symbol) Fast switching inputs & low
3 wire type on inputs, 3
M12 waterproof (IP67) 32 Combination leakage output current
A 2 wire type on outputs Transistor input /
threaded connector Combination DT E Source
4 wire type on inputs, transistor output
B Screw terminal block 42
2 wire type on outputs
One touch connector f or
C Symbol Number of I/O Points
I/O connections
CF FCN connector Symbol Points 8 8 points
One touch connector for None 1 Common 16 16 points
CU I/O, power and
network connections B 2 Commons 32 32 points

Note on “1-wire”, “2-wire”, “3-wire” and “4-wire” terminology


Throughout the CC-Link blocks, we reference these terms. These are concise definitions for the following ways to connect I/O devices:
• 1 wire: One side of the load is connected to the I/O module terminal block. The other side is connected to a common terminal shared by
all devices.
• 2 wire: One side of the load is connected to the I/O module terminal block. The other side is connected to a dedicated common terminal for
that load on the terminal block. Note that in some cases, the common terminals may be connected internally.
• 3 wire: The I/O block is configured to accept loads with three connections (such as various types of sensor, etc)
• 4 wire: As three wire, but configured for four connection devices.

Note on connector types


Various different types of connector styles are available on the CC-Link blocks, as follows:
NOTE: IN GENERAL, BLOCKS ARE NOT SUPPLIED WITH CONNECTORS AND ACCESSORIES (IF REQUIRED).
PLEASE ENSURE YOU HAVE ALL NECESSARY CONNECTORS BEFORE BEGINNING AN INSTALLATION.
• Screw terminals: These are conventional screw terminals. Note that all wiring will require cutting, stripping, and terminating with a
crimped spade or ring type lug to insure a reliable connection.
• FCN connector: These are 40 pin connectors that allow fast connection and disconnection of a whole group of I/O in one action.
The following types of FCN connector are available:

Model Number Certification Number of Pins Wiring Type Connector Type Stocked Item
A6CON1 UL • cUL 40 Solder FCN S
A6CON2 UL • cUL 40 Crimp FCN S
A6CON3 UL • cUL 40 IDC FCN S

Water resistant M12 connectors: Selected I/O blocks are available in an IP67 water resistant format. These use connectors that use an
M12 metric threaded connector to make all connections. Benefits include:
• Water tight connections for installations where exposure to liquids is required
• In some installations, these blocks may be mounted directly on a machine without the need for an enclosure, reducing system cost.
Miscellaneous accessories: The following accessories are also available: Note the quantity per box and calculate the correct order
quantity accordingly.

One Touch Connector (OTC): OTCs offer significant installation and maintenance benefits as follows:
• IDC (insulation displacement connector) type connection avoids need for stripping or terminating wiring with lugs. Simply cut wiring to
length, insert into connector and snap shut to make a reliable connection. These are available for I/O, network and power connections.
• Easily connected and disconnected individually or in groups to assist maintenance
• Compact design minimizes I/O block size

Model Number Gauge Size (AWG) Color Qty. Per Box Comments Stocked Item
A6CON-P214 26-24 Transparent 20 For I/O S
A6CON-P220 26-24 Yellow 20 For I/O -
A6CON-P514 22-20 Red 20 For I/O -
A6CON-P520 22-20 Blue 20 For I/O -

2 Selection Guide Edition 18 • Revised January 1, 2018


Water resistant M12 connectors: Selected I/O blocks are available in an IP67 water resistant format. These use connectors that use an
M12 metric threaded connector to make all connections. Benefits include:
• Water tight connections for installations where exposure to liquids is required
• In some installations, these blocks may be mounted directly on a machine without the need for an enclosure, reducing system cost.
Miscellaneous accessories: The following accessories are also available: Note the quantity per box and calculate the correct order
quantity accordingly.

One Touch Connector (OTC): OTCs offer significant installation and maintenance benefits as follows:
• IDC (insulation displacement connector) type connection avoids need for stripping or terminating wiring with lugs. Simply cut wiring to
length, insert into connector and snap shut to make a reliable connection. These are available for I/O, network and power connections.
• Easily connected and disconnected individually or in groups to assist maintenance
• Compact design minimizes I/O block size
Model Number Gauge Size (AWG) Color Qty. Per Box Comments Stocked Item
A6CON-P214 26-24 Transparent 20 For I/O S
A6CON-P220 26-24 Yellow 20 For I/O -
A6CON-P514 22-20 Red 20 For I/O -
A6CON-P520 22-20 Blue 20 For I/O -

Model Number Quantity Per Box Description Stocked Item


BA1SJ61-S N/A Three conductor, CLPA certified, signal only CC-Link cable. Sold by the meter. S
BA1SJ61-P N/A Five conductor, CLPA certified, signal and power CC-Link cable. Sold by the meter. S
A6CON-L5P 10 OTC network connector S
A6CON-PW5P 10 OTC power connector S
A6CON-LJ5P 5 OTC Network on-line connector (*1) S
A6CON-PWJ5P 5 OTC Power on-line connector (*2) S
A6CON-TR11 1 Terminating resistor (*3) S
A6CAP-DC1 20 Dust cap to protect unused connectors on IP67 modules (*4) -
A6CAP-WP1 20 Metal waterproof cap to protect unused connectors on IP67 modules (*4) -
A6CAP-WP2 20 Plastic waterproof cap to protect unused connectors on IP67 modules (*4) -
A6PLT-J65V1 1 DIN rail mount for vertical format blocks (single width) -
A6PLT-J65V2 1 DIN rail mount for vertical format blocks (double width) -
BKO-C8834H12 2 x 110 ohm, 2 x 130 ohm CC-Link terminating resistors with insulating lugs S
BKO-C10798H02 1 QJ61BT11 network terminal block assembly S
Notes:
1. This connector accepts two A6CON-L5P and plugs into a CC-Link module. Its function is to allow a network connection to be connected/disconnected via a single operation, and maintains the
network connection. Note these are only used with “VBT” type modules.
2. Accepts two A6CON-PW5P and performs the same function as A6CON-LJ5P for power. Use only with “VBT” modules.
3. Required at the end of a network segment for reliable communication for “VBT” modules.
4. AJ65FBT and AJ65SBTW4 type modules.

Selection Guide Edition 18 • Revised January 1, 2018 Mitsubishi Electric Automation | DISTRIBUTED I/O 3

You might also like