WSP22G Ona3 - 400 P 120801 e 01
WSP22G Ona3 - 400 P 120801 e 01
WSP22G Ona3 - 400 P 120801 e 01
1 Description
These direct acting 2/2 solenoid operated directional seat and industrial applications where leak−tight shut−off func-
valves, series WSP22GNA3/WSP22ONA3, are size tions are crucially important. Examples are where loads,
3, pressure balanced screw−in cartridges with a 3/4−16 UNF tensions, or clamping forces must be held without leakage.
mounting thread. They are designed on the poppet/seat All external parts of the cartridge are zinc plated and chromi-
principle, and are therefore virtually leak−free in both direc- ted (CrVI−free) and are thus suitable for use in the harshest
tions of flow (bidirectional seat−valve shut−off). De−energi- operating environments. The slip−on coils can be replaced
sed closed" and de−energised open" functions are availa- without opening the hydraulic envelope and can be positio-
ble. The straightforward design delivers an outstanding ned at any angle through 360°. If you intend to manufacture
price/performance ratio. These 2/2 solenoid operated seat your own cavities or are designing a line−mounting installa-
valves are primarily used as pilot valves in certain mobile tion, please refer to the section Related data sheets".
2 Symbol
1 1
2 2
WSP22GNA3 WSP22ONA3
3 Technical data
Reference: 400−P−120801−E−01/10.07
Classification: 430.300.−.305.305.300 1/4
Hydraulic characteristics Description, value, unit
Maximum operating pressure (ports 1 and 2) 420bar
Maximum flow rate 15l/min
Flow direction 1 → 2 / 2 → 1, see symbols
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please consult BUCHER
Hydraulic fluid temperature range −25°C +80°C
Viscosity range 10500mm 2/s (cSt), recommended 15...250mm2/s (cSt)
Minimum fluid cleanliness class 20/18/15
Cleanliness class to ISO 4406:1999
4 Performance graphs
measured with oil viscosity 33mm2/s (cSt), coil at steady−state temperature and 10 % undervoltage
p = f (Q) Performance limits
p [bar]
P0059.ai
420
300
200
100
0
0 3 6 9 12 15 Q [l/min]
Δp = f (Q) Pressure drop − Flow rate characteristic Δp = f (Q) Pressure drop − Flow rate characteristic
[WSP22 G] [WSP22 O]
p [bar] p [bar]
P0061.ai P0060.ai
20 20
1→2
2→1
2→1
15 15
1→2
10 10
5 5
0 0
0 3 6 9 12 15 Q [l/min] 0 3 6 9 12 15 Q [l/min]
400−P−120801−E−01/10.07 2/4
Series WSP22GNA3/ WSP22ONA3
5 Dimensions & sectional view
74.4
Ma = 2.7 ± 0.3 [Nm]
56.4
3
3.3
47.5
Ø 36
73.5
102.6
24
Ma = 40 ± 2 [Nm]
1
1 3/4−16UNF
29.1
2 4
6 Installation information
Important NBR seal kit no. DS−246−N 1)
When fitting the cartridges, use the specified tigh-
Item Qty. Description
tening torque. No adjustments are necessary,
since the cartridges are set in the factory. 1 1 O−ring no.017 ∅17,17x 1,78 N90
400−P−120801−E−01/10.07 3/4
Series WSP22GNA3/ WSP22ONA3
7 Ordering code
Ex. W S P 22G N A 3 _ − 1 24VDC _
W = directional valve
S = seat valve, direct acting
P = high−pressure model, 420 bar
22G = 2/2 function, de−energised closed
22O 2/2 function, de−energised open
N = electrically operated, VDC = 27 W / VAC = 25 W
A ... Q = standard model − see relevant data sheets
Y ... R = special features − please consult BUCHER
3 = nominal size 3 (primarily for pilot controls)
(blank) = NBR (nitrile) seals (standard)
V = FKM (Viton) seals
(special seals − please consult Bucher)
1 ... 9 = design number (omit when ordering new units)
... = voltage and current plainly specified
(blank) = ISO 4400 / DIN 43 650 mating plug (standard, IP65)
M100 = without mating DIN plug
C = Kostal plug connection (IP65)
JT = Junior Timer radial plug connection (with quenching diode, IP65)
IT = Junior Timer axial plug connection (with quenching diode, IP65) mating plug not supplied
D = Deutsch plug connection DT04−2P (IP 67)
DT = Deutsch plug connection DT04−2P (with quenching diode, IP 67)
F = flying leads (500 mm)
[email protected] www.bucherhydraulics.com
E 2007 by Bucher Hydraulics AG, CH−3714 Frutigen
All rights reserved.
Data is provided for the purpose of product description only, and must not be considered as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.
400−P−120801−E−01/10.07 4/4
Series WSP22GNA3/ WSP22ONA3