WSP22G Ona3 - 400 P 120801 e 01

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

2/2 Cartridge Seat Valve, Size 3

Qmax = 15l/min,pmax = 420bar


Pilot valve, with solenoid operation, bidirectional seat−valve shut−off, direct acting
Series WSP22GNA3/ WSP22ONA3

S Can be used as a high−pressure pilot valve


S With bidirectional seat−valve shut−off
S Compact construction for
cavity type AL ˘ 3/4−16 UNF
S All external parts zinc plated, chromited (CrVI−free)
S High pressure wet−armature solenoids
S The slip−on coil can be rotated, and it can be
replaced without opening the hydraulic envelope
S Various plug connections and voltages
are available
S Can be fitted in a line−mounting body

1 Description
These direct acting 2/2 solenoid operated directional seat and industrial applications where leak−tight shut−off func-
valves, series WSP22GNA3/WSP22ONA3, are size tions are crucially important. Examples are where loads,
3, pressure balanced screw−in cartridges with a 3/4−16 UNF tensions, or clamping forces must be held without leakage.
mounting thread. They are designed on the poppet/seat All external parts of the cartridge are zinc plated and chromi-
principle, and are therefore virtually leak−free in both direc- ted (CrVI−free) and are thus suitable for use in the harshest
tions of flow (bidirectional seat−valve shut−off). De−energi- operating environments. The slip−on coils can be replaced
sed closed" and de−energised open" functions are availa- without opening the hydraulic envelope and can be positio-
ble. The straightforward design delivers an outstanding ned at any angle through 360°. If you intend to manufacture
price/performance ratio. These 2/2 solenoid operated seat your own cavities or are designing a line−mounting installa-
valves are primarily used as pilot valves in certain mobile tion, please refer to the section Related data sheets".

2 Symbol
1 1

2 2

WSP22GNA3 WSP22ONA3

3 Technical data

General characteristics Description, value, unit


Designation 2/2 cartridge seat valve
Design pilot valve, bidirectional seat−valve shut−off,
with solenoid operation, direct acting
Mounting method screw−in cartridge 3/4−16 UNF
Tightening torque 40± 2 Nm
Size nominal size 3, cavity type AL
Weight 0.40 kg
Mounting attitude unrestricted
Ambient temperature range −25°C  +50°C

Reference: 400−P−120801−E−01/10.07
Classification: 430.300.−.305.305.300 1/4
Hydraulic characteristics Description, value, unit
Maximum operating pressure (ports 1 and 2) 420bar
Maximum flow rate 15l/min
Flow direction 1 → 2 / 2 → 1, see symbols
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please consult BUCHER
Hydraulic fluid temperature range −25°C  +80°C
Viscosity range 10500mm 2/s (cSt), recommended 15...250mm2/s (cSt)
Minimum fluid cleanliness class 20/18/15
Cleanliness class to ISO 4406:1999

Electrical characteristics Description, value, unit


Supply voltage 12V DC, 24V DC
115V AC, 230V AC (5060Hz)
Supply voltage tolerance ±10%
Nominal power consumption V DC = 27 W
V AC = 25 W
Relative duty cycle 100%
Protection class to EN 60 529 IP 65 / IP 67, see Ordering code"
(when connector plugs are properly fitted)
Electrical connection 3−pin square plug to ISO 4400 / DIN 43 650 (standard)
for other connectors, see Ordering code"

4 Performance graphs
measured with oil viscosity 33mm2/s (cSt), coil at steady−state temperature and 10 % undervoltage
p = f (Q) Performance limits
p [bar]
P0059.ai
420

300

200

100

0
0 3 6 9 12 15 Q [l/min]

Δp = f (Q) Pressure drop − Flow rate characteristic Δp = f (Q) Pressure drop − Flow rate characteristic
[WSP22 G] [WSP22 O]
p [bar] p [bar]
P0061.ai P0060.ai
20 20
1→2
2→1
2→1
15 15
1→2

10 10

5 5

0 0
0 3 6 9 12 15 Q [l/min] 0 3 6 9 12 15 Q [l/min]

400−P−120801−E−01/10.07 2/4
Series WSP22GNA3/ WSP22ONA3
5 Dimensions & sectional view
74.4
Ma = 2.7 ± 0.3 [Nm]
56.4

3
3.3

47.5
Ø 36
73.5
102.6

24

Ma = 40 ± 2 [Nm]
1
1 3/4−16UNF
29.1

2 4

6 Installation information
Important NBR seal kit no. DS−246−N 1)
When fitting the cartridges, use the specified tigh-
Item Qty. Description
tening torque. No adjustments are necessary,
since the cartridges are set in the factory. 1 1 O−ring no.017 ∅17,17x 1,78 N90

2 1 O−ring no.014 ∅12,42x 1,78 N90


Attention 3 2 O−ring ∅16.00x 2.00 Viton
Only qualified personnel with mechanical skills
4 2 Backup ring ∅10,70x1,45x1,00 FI0751
may carry out any maintenance work. Generally,
the only work that should ever be undertaken is to
check, and possibly replace, the seals. When Important
changing seals, oil or grease the new seals tho- 1) Seal kit with FKM (Viton) seals, no. DS−246−V
roughly before fitting them.

400−P−120801−E−01/10.07 3/4
Series WSP22GNA3/ WSP22ONA3
7 Ordering code
Ex. W S P 22G N A 3 _ − 1 24VDC _

W = directional valve
S = seat valve, direct acting
P = high−pressure model, 420 bar
22G = 2/2 function, de−energised closed
22O 2/2 function, de−energised open
N = electrically operated, VDC = 27 W / VAC = 25 W
A ... Q = standard model − see relevant data sheets
Y ... R = special features − please consult BUCHER
3 = nominal size 3 (primarily for pilot controls)
(blank) = NBR (nitrile) seals (standard)
V = FKM (Viton) seals
(special seals − please consult Bucher)
1 ... 9 = design number (omit when ordering new units)
... = voltage and current plainly specified
(blank) = ISO 4400 / DIN 43 650 mating plug (standard, IP65)
M100 = without mating DIN plug
C = Kostal plug connection (IP65)
JT = Junior Timer radial plug connection (with quenching diode, IP65)
IT = Junior Timer axial plug connection (with quenching diode, IP65) mating plug not supplied
D = Deutsch plug connection DT04−2P (IP 67)
DT = Deutsch plug connection DT04−2P (with quenching diode, IP 67)
F = flying leads (500 mm)

8 Related data sheets


Reference (Old no.) Description
400−P−040011 (i−32) The form−tool hire programme
400−P−040171 (i−33.10) Cavity type AL
400−P−120110 (W−2.141) Coils for screw−in cartridge valves
400−P−720101 (G−4.10) Line−mounting body, type GALA (G 3/8")

[email protected] www.bucherhydraulics.com
E 2007 by Bucher Hydraulics AG, CH−3714 Frutigen
All rights reserved.
Data is provided for the purpose of product description only, and must not be considered as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.

400−P−120801−E−01/10.07 4/4
Series WSP22GNA3/ WSP22ONA3