Next Generation Multiservice Access Nodes

· Carrier-class multiservice platform: Ethernet services, high speed, low speed, analog
voice, data, fiber multiplexing and pseudowire connectivity
· Central solution aggregating Ethernet and TDM services over fiber/copper from RAD CPEs
towards SDH/SONET and/or PSN core networks
· MEF CE 2.0 certified, support of MEF applications: Ethernet Private Line (EPL/EVPL),
Ethernet Private LAN (EP-LAN/EVP-LAN) and E-TREE, with flexible mapping of user traffic
into Ethernet flows
· Distributed network functions virtualization (D-NFV) for rapid rollout of new services and
network capabilities
· Certified for IEEE-1613

Central site solution, major building block Hybrid Access solution. Megaplex-4 provision multiple legacy and next-
of RAD’s portfolio for service providers, converts the data stream from TDM/serial generation services over their high
carriers and utilities, Megaplex-4 functions modules in the MP-4100/4104 chassis capacity pipes.
as a carrier-class, TDM and Ethernet (E1/T1, SHDSL, data or voice ports) into IP
aggregator, as well as a high capacity DS0 or MPLS packets for transmission over RESILIENCY
cross connect and next generation Ethernet, IP or MPLS networks.
Carrier-Class Reliability
multiservice access node. It transports
Carrier-class service reliability ensures
legacy and next-generation services over MARKET SEGMENTS AND
continuous availability and sub-50ms
any infrastructure for seamless migration. APPLICATIONS
restoration in the event of network
The Megaplex-4 family includes two Various users can benefit from the outages through system redundancy
devices: a larger 10-slot Megaplex-4100 Megaplex-4 solution: options, link and path protection schemes
and a compact 4-slot Megaplex-4104. · SDH/SONET customers who need to and enhanced support for diverse ring
When deployed as a carrier-class Ethernet maximize bandwidth utilization of their topologies.
aggregator, Megaplex-4 can terminate network Traffic Duplication
Ethernet traffic carried over · Subscribers with mixed Ethernet and Traffic Duplication, a unique technology
E1/T1/SHDSL/SHDSL.bis/fiber links or TDM services available in Megaplex-4, allows networks
native Ethernet copper and fiber, as well with mission-critical applications to
as through a VCG in the SDH/SONET · Subscribers looking for a future-proof
migration path to IP connectivity enhance reliability and performance. It can
circuits. This traffic can then be switched be used to minimize delay on critical utility
either to a different PDH/TDM trunk or to · Dual network owners using applications (such as Teleprotection) by
Ethernet ports. SDH/SONET for voice, and packet for capitalizing on Carrier Ethernet reduced
With RAD’s Service Assured Access (SAA) data. latency at higher speeds. Mission-critical
capabilities, Megaplex-4 provides Carrier Its ability to handle a broad range of traffic can be transported over a new
Ethernet functionalities, such as traffic Ethernet, data and voice services, as well Carrier Ethernet network running in
management (TM), standards-based as a large variety of network technologies parallel with the existing SDH/SONET
operations, Administration and Monitoring in a single compact managed node, makes network, while preparing for future, full
and Performance Monitoring (OAM&P). Megaplex-4 an ideal core/edge solution for service migration.
Using pseudowire, Megaplex-4 provides carriers and service providers. It also
legacy services over packet-switched provides a perfect fit for large enterprises,
networks (PSN) making it a fundamental utilities and transportation companies that
building block in RAD’s Service Migration require an efficient way to transport and
Megaplex-4
Next Generation Multiservice Access Nodes

D-NFV Specifications Compliance


The D-NFV option adds to Megaplex-4 a SDH: ITU-T G.957, G.798, G.783
SDH/SONET INTERFACE
built-in standard Intel x86 core that hosts SONET: ANSI T1.105-1995, GR-253-core
virtual machines providing virtual network Number of Ports GFP (Generic Framing Procedure): ITU-T
functions (VFs) or value-added service 2 per CL.2 module (4 per chassis) G.7041, ANSI T1-105.02, framed mode;
capabilities. This new capability provides a LCAS (Link Capacity Adjustment Scheme):
Protection
quick and easy way to introduce new ITU-T G.7042
Link Protection
services and applications with the benefit
· 1+1 unidirectional / bidirectional APS Framing
of function localization at the customer SDH: ITU-T G.707, G.708, G.709
(G.841, Clause 7.1)
premises.
· 1+1 bidirectional optimized APS (G.841 SONET: GR-253-core
Annex B. Linear Multiplex Section
MANAGEMENT AND SECURITY GIGABIT ETHERNET INTERFACE
(MSP)
Megaplex-4 offers carrier-class Path Protection Number of Ports
provisioning features, including end-to- · 1+1 unidirectional APS (G.842,Clause 2 per CL.2 module (4 per chassis)
end path management, to ensure 6.2.3) - Ring interworking with a SNCP
continuous service availability. Advanced ring Data Rate
SNMP management capabilities enable Line Coding 10/100/1000 Mbps
Megaplex-4 to control and monitor all NRZ Autonegotiation (copper interface only)
network elements: SDH/SONET access and Connectors (per port)
Connectors
ring units, as well as remote POP and first RJ-45, shielded
SFP socket
mile broadband access feeders and CPEs. SFP socket
Data Rate
STM-4/OC-12: 622.08 Mbps ± 4.6 ppm Maximum Frame Size
STM-1/OC-3:155.52 Mbps ± 4.6 ppm 9600 bytes (for max. frame sizes
supported by different I/O modules, see
individual data sheets)

Megaplex-4 Control Center

GbE
PSN

Megaplex-4 Megaplex-4 Megaplex-4

SDH/SONET
E1/T1 FO

Airmux

SHDSL.bis

FO FXS E&M PA FXS E&M PA


MP-2100

E1/T1
Optimux
TAC TAC
Airmux
PBX LAN LAN
ASMi

SCADA LAN LAN PBX

Figure 1. Megaplex-4 as Multiservice Platform with Diverse Interfaces and Access Topologies for U&T Market Segment

2
Data Sheet

Compliance Hitless Switching Redundancy in Ring


MAC Address Table
CE 2.0, MEF 6 (E-Line – EPL and EVPL, topology according to IEC 62439-3
Up to 16K entries with configurable limiter
E-LAN – EPLAN and EVPLAN, E-TREE), RSTP on network ports (CL.2/A)
MEF 10, MEF 9, MEF 8 MEF 14, MEF 20, Operation Mode
IEEE 802.3, 802.3u, 802.1q, 802.1p, VLAN-aware, VLAN-unaware
802.1X, 802.3ad, 802.3-2005, 802.3ah,
802.1ag, ITU-T Y.1731, G.8032 OAM
IEEE 802.3ah
Service IEEE 802.1ag: CCM, Loopback, link trace,
EPL and EVPL (flow-based) MEP
E-LAN (EP-LAN and EVP-LAN), ITU-T Y.1731, Frame-loss, Frame-delay,
bridge-based Frame-delay-variation, PM
E-TREE (bridge-based)
Protection
Bandwidth Profile Link aggregation supporting link and
CIR/CBS, EIR/EBS per flow equipment protection

Wireless
FE

Airmux
Video

Airmux
E3 Chanellized
FE

Router FCD-IP
STM-1

DXC-8R FCD-E1E

n x E1 ETH E1
FE/GbE
PSN RICi-8 DXC-4
POP FE E1

IPmux
SHDSL ETH
E1/V.35
SHDSL.bis
ASMi
ETH
Megaplex-4 FO
STM-4/ n x E1
OC-12 Optimux
SDH/SONET
STM-1/
SHDSL ETH
OC-3
SHDSL.bis E1/V.35
ASMi-53
T3 FE ETH

RV Station ETX
ETH
STM-1/OC-3
E1/T1
FCD-155E
Voice
E1/T1 Data
ETH
MP-2100/2104

T3
Radio
Megaplex-4104
Radio

Figure 2. Megaplex-4 as a Central Site Aggregator for different RAD CPEs, Ethernet and TDM Aggregator for SDH/SONET and PSN

Ethernet Ring Protection Switching


Forwarding Mode
Flow-based, bridge-based complying with ITU-T G.8032

3
Megaplex-4
Next Generation Multiservice Access Nodes

SDH/SONET AND GBE SFPS Connectivity TIMING


For full details, see the SFP/XFP Out-of-band
Transceivers data sheet at www.rad.com Inband, via the STM-4/OC-12/STM-1/OC-3 Clock Sources
links or over a dedicated timeslot in any Users can define the following clock
· All SFPs listed for STM-4/OC-12 and
E1/T1 or SHDSL link or via any of the user sources:
STM-1/OC-3 are supported by the
SDH/SONET link except for those with Ethernet ports · Recovered from the STM-4/OC-12/
external calibration STM-1/OC-3 interface, including
Ethernet Management Port
automatic selection, based on SSM
· All SFPs listed for GbE are supported Interface: 10/100BaseT
(Synchronization Status Messaging)
by the GbE link, except for those with Connector: RJ-45
external calibration and SGMII. · Sync-E clock, recovered from the GbE
Control Port
Note: It is strongly recommended to order this Interface: RS-232/V.24 (DCE) interface (CL.2/A modules only)
device with original RAD SFPs installed. This will Connectors: · Internal crystal free-running
ensure that prior to shipping, RAD has performed · CL.2: DB-9 oscillator-based clock
comprehensive functional quality tests on the · CL.2/4104: MINI-USB · Derived from the Receive clock of a
entire assembled unit, including the SFP devices.
Baud rate: 9.6, 19.2, 38.4, 57.6, 115.2 specified user port
RAD cannot guarantee full compliance to product
specifications for units using non-RAD SFPs. SECURITY · Adaptive clock recovered (ACR) from a
Port-Based Network Access Control pseudowire circuit
I/O MODULES
(PNAC) per IEEE 802.1X-2100: · Clock distribution mechanism
See Table 1. For detailed description, see (SSM-like) over E1 TS0 interoperable
· Port-based authorization
separate data sheets. with Nokia proprietary timing
· Supplicant for CL.2/A GbE ports
· Authenticator applicable on M-ETH mechanism.
MANAGEMENT
modules and VS modules with Ethernet Station Clock
Management Options ports Bit rate:
CLI MAC-based authentication support
RADview management and VF (802.1X-based) · 1.544 Mbps (T1) (AMI)
orchestration suite · 2.048 Mbps (E1) (AMI)
License-based (per CL) MACsec per IEEE
Standalone Shelf View application · 2.048 MHz squarewave
802.1AE-2006 and 802.1AEbn-2011
Connector: RJ-45
Tools (128/256-bit)
Telnet/SSHv2, SNMPv2, SNMPv3, SFTP · Data Encryption and integrity
RADIUS, TACACS+ protection hop-by-hop
· Key exchange based on 802.1X
· Special ordering option for 2GbE ports
with MACsec on CL.

4
Data Sheet

Table 1. Megaplex-4 I/O Modules

Module Description Operating in


MP-2100/2104
System Modules
CL.2 Common Logic module
CL.2/A Common Logic module, Carrier Ethernet class
PS AC or DC power supply module
I/O Modules (in alphabetical order of names)
ACM Alarm and diagnostics module with four outbound relays Yes
ASMi-54C 8-port SHDSL.bis module with 2 Ethernet ports
ASMi-54C/N 8-port SHDSL/SHDSL.bis module with 2 Ethernet ports and 8 E1 ports
D-NFV Distributed network functions virtualization module
HS-6N, HS-12N 6- or 12-port n x 64 kbps high speed module Yes
HS-703 4-channel Codirectional data module Yes
HSF-2 2-port fiber optic teleprotection interface module Yes
HS-RN 4-port sub-DS0 low speed module Yes
HS-S 4-channel ISDN “S”-interface module Yes
LS-6N, LS-12 6- or 12-port low speed modules Yes
M-ETH 8-port GbE interface module
M16E1, M16T1 16-port E1 or T1 modules
M8E1, M8T1 8-port E1 or T1 modules with 3 Ethernet ports
M8SL 8-port SHDSL E1 module with 3 Ethernet ports
MPW-1 TDM pseudowire access gateway with 3 Ethernet ports
OP-108C Dual 4 x E1 and Ethernet fiber multiplexer module

Ringer-2100R DC power supply module for DC feed and up to 32 voice channel ring voltages
Ringer-4104R for Megaplex-4100/Megaplex-4104
SH-16 16-port SHDSL.bis EFM module with optional E1 and PW support

T3 T3 multiplexer module
TP (Teleprotection) 4-input, 8-output port teleprotection module with selectable trip voltage
VC-4/4A/8/8A/16 4/8/16-port FXS/FXO/E&M PCM and ADPCM analog voice modules Yes
VC-4/OMNI 4-port PCM omnibus voice module Yes
VC-6/LB 6-port PCM voice module for local battery telephones Yes
VS-12 12-port serial module with 2 Ethernet ports
VS-6/BIN 6-port serial module with 8 binary in/out command ports and 1 Ethernet port
VS-6/C37 6-port serial module with 2 fiber optic C37.94 ports and 1 Ethernet port
VS-6/E&M 6-port serial module with 4 E&M voice ports and 1 Ethernet port
VS-FXS/E&M Voice module with 4 E&M ports and 8 FXS ports
VS-6/FXO 6-port serial module with 8 FXO voice ports and 1 Ethernet port
VS-6/FXS 6-port serial module with 8 FXS voice ports and 1 Ethernet port
VS-16E1T1 16-port E1/T1 module with PW or EOP support

VS-6/E1T1 6-port serial module with 8 E1/T1 ports, 1 Ethernet port and PW support
Note: For specific HW/SW versions of Megaplex-210x modules supported by the Megaplex-4 chassis, please contact your local
RAD partner.

5
Megaplex-4
Next Generation Multiservice Access Nodes

Power Supply Input Physical


DIAGNOSTICS
MP-4100 MP-4100 (4U-high)
Alarm Relay 2 power supply module slots
AC: 115 /230 VAC (allowed range: 85 to
1 inbound relay – RS-232 levels (dry 2 CL. 2 module slots
264 VAC), 50/60 Hz
contact) 10 slots for I/O modules
HVDC support: 100 to 360 VDC
2 outbound relays triggered by Height: 18 cm (7 in) (4U)
major/minor alarms DC:
Width: 44 cm (17 in)
Operation: normally open, normally 48 VDC (allowed range: -36 to -56 VDC)
Depth (regular): 33 cm (13 in)
closed, using different pins 24 VDC (allowed range: 20 to 36 VDC)
Depth (IEEE-1613-compliant): 37 cm
Connectors: Selectable ground reference or floating
(14.6 in)
· CL.2: DB-9, female ground
Weight: 15.3 kg (33.8 lb) max.
· CL.2/4104: 9-pin, flat MP-4104 (fully loaded chassis)
AC: 90 to 264 VAC, 50/60 Hz MP-4104 (2U-high)
GENERAL
HVDC support: 110 to 300 VDC 2 power supply module slots
Environment DC: 48 VDC (allowed range: -36 to 2 CL.2 module slots
MP-4100 -56 VDC); selectable ground reference or 4 slots for I/O modules
Operating temperature: floating ground Height: 9 cm (3.5 in) (2U)
· Regular: -10°C to 55°C (14°F to 131°F) Width: 44 cm (17 in)
Maximum Input Power
· IEEE-1613 “no-fan” compliant system Depth: 33 cm (13 in)
and modules: -20°C to 55°C (-4°F to MP-4100 Weight: 7.54 kg (16.6 lb)
131°F) 315W + power supplied for ring and feed (fully loaded chassis)
Storage temperature: -20°C to +70°C voltage Note: The chassis weight depends of the
(-4°F to +160°F) type and number of installed modules.
MP-4104
Humidity: up to 95%, non-condensing 200W + power supplied for ring and feed CL.2 Module
MP-4104 voltage Height: 17.3 cm (6.8 in)
Operating temperature: Width: 4.5 cm (1.8 in)
MP-4104 Depth (regular): 32.5 cm (12.8 in)
-10°C to 55°C (14°F to 131°F) 160W + power supplied for ring and feed
Storage temperature: -20°C to +70°C Depth (IEEE-1613-compliant): 35 cm
voltage (13.8 in)
(-4°F to +160°F)
Humidity: up to 95%, non-condensing Output Power (max) Max weight (regular): 630 g (1.3 lb)
Max weight (IEEE-1613-compliant): 2030 g
Note: Actual operating temperature range is
MP-4100 (2.27 lb)
determined by the specific modules installed in the · Regular: 250W
chassis. For extended operating temperature · IEEE-1613 “no-fan” compliant system CL.2/4104 Module
ranges, contact your local RAD Business Partner. and modules: 175W Height: 17.3 cm (6.8 in)
Width: 2.5 cm (1 in)
MP-4104
Depth: 32.5 cm (12.8 in)
160W
Max weight: 540 g (1.2 lb)
Power Consumption (per CL, max)
27.75 W

6
Data Sheet
Megaplex-4

Ordering MP-4100M-CL.2/GBEAPSFP RM-MP-MX-23/19

Communications Ltd. All other trademarks are the property of their respective holders.
which product is covered by which patent, please see ipr.rad.com. The RAD name, logo, logotype, and the product names MiNID, Optimux, Airmux, IPmux, and MiCLK are registered trademarks of RAD Data
464-101-10/17 (4.9) Specifications are subject to change without prior notice. ã 1988–2017 RAD Data Communications Ltd. RAD products/technologies are protected by registered patents. To review specifically
MP-4104M-CL.2/GBEAPSFP Hardware kit for mounting one MP-4100
Megaplex-4 must be ordered with the Megaplex-4100 or Megaplex-4104 CL.2 unit into both 19-inch and 23-inch racks
RADcare Basic Plus service package for module, Carrier Ethernet class with GbE Megaplex-4104 (only with MP-4104-2)
one year. SFP sockets and 2 GbE MACsec engines
CBL-MUSB-DB9F
RECOMMENDED CONFIGURATIONS MP-4100M-CL.2/GBEAPUTP Mini-USB to DB-9 control cable
MP-4104M-CL.2/GBEAPUTP
MP-4100-2/48R/622GBEASFPR CBL-MP-4104/AR/OPEN/2M
MP-4104-2/48R/622GBEASFPR Megaplex-4100 or Megaplex-4104 CL.2
Open-ended alarm cable
module, Carrier Ethernet class with GbE
Megaplex-4100 or Megaplex-4104 chassis copper interface and 2 GbE MACsec RM-42
with dual 48 VDC PS modules and dual engines Hardware kit for mounting one MP-4104
CL.2 modules, Carrier-Ethernet class with
SDH/SONET SFP sockets and GbE SFP MP-4100M-CL.2/DS0 unit in a 19-inch rack
sockets MP-4104M-CL.2/DS0
OPTIONAL ACCESSORIES
MP-4100-2/230R/622GBEASFPR Megaplex-4100 or Megaplex-4104 CL.2
module for E1/T1/DS0 cross-connect MP-2100-RM-ETSI/19
MP-4100-2/115R/622GBEASFPR
Hardware kit for mounting one MP-4100
MP-4104-2/ACR/622GBEASFPR MP-4100M-CL.2/622GBEASFP/155SK unit into ETSI racks (fits also 10-inch
Megaplex-4100 or Megaplex-4104 chassis MP-4104M-CL.2/622GBEASFP/155SK racks)
with dual AC PS modules and dual CL.2 Megaplex-4100 or Megaplex-4104 CL.2 Note: This RM can be either ordered in addition to
modules, Carrier-Ethernet class, with module, Carrier-Ethernet class, with RM-MP-MX-23/19 or received for free instead of it.
SDH/SONET SFP sockets and GbE SFP STM-1/OC-3 SFP sockets and GbE SFP
sockets sockets, can be activated for STM-4/OC-12 RM-51
by purchasing a SW license key (MP-4100- Thermal isolation panel for mounting two
MP-4100-2/48R/DS0R
LIC/622SK or MP-4104-LIC/622SK) fanless MP-4100 devices in 19" rack
MP-4104-2/48R/DS0R
Megaplex-4100 or Megaplex-4104 chassis RM-42-CM
SPECIAL CONFIGURATIONS
with dual 48 VDC PS modules and dual Hardware kit for mounting one MP-4104
CL.2 modules without SDH/SONET and GbE Please contact your local RAD partner for unit in a 19-inch rack with cable
links additional configuration options. management
MP-4100M-CL.2/622GBEASFP Note: CLI prompt and/or SDH/SONET path trace
WM-42
MP-4104M-CL.2/622GBEASFP string can be changed (factory-set) according to
Hardware kit for installing MP-4104 unit
the customer request.
Megaplex-4100 or Megaplex-4104 CL.2 on a wall
module, Carrier Ethernet class with SUPPLIED ACCESSORIES WM-42-CM
SDH/SONET SFP sockets and GbE SFP
Megaplex-4100 (only with MP-4100-2) Hardware kit for installing a MP-4104 unit
sockets
on a wall with cable management
MP-4100M-CL.2/GBEASFP CBL-SP-9/SH
MP-4104M-CL.2/GBEASFP Dual DB-9 to single DB-9 control cable

Megaplex-4100 or Megaplex-4104 CL.2 CBL-MP-4100/AR/OPEN/2M


module, Carrier Ethernet class with GbE Open-ended alarm cable
SFP sockets

International Headquarters North American Headquarters


24 Raoul Wallenberg Street 900 Corporate Drive
Tel Aviv 69719, Israel Mahwah, NJ 07430, USA
Tel. 972-3-6458181 Tel. 201-5291100
Fax 972-3-6498250, 6474436 Toll free 1-800-4447234
E-mail [email protected] Fax 201-5295777
E-mail [email protected]

www.rad.com Order this publication by Catalog No. 803832

You might also like