Plug-In / PCB Relays - Overview: 30 Series
Plug-In / PCB Relays - Overview: 30 Series
Rated No. of
current Contacts Features Sockets
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Plug-in / PCB Relays - Overview
Rated No. of
current Contacts Features Sockets
8A 2 CO
Miniature industrial relays
- Socket mount or direct connection via Faston connectors
46 Series - AC & DC coils 97 Series
- Available with lockable test button, mechanical flag & LED indicator
- 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts
16 A 1 CO
10 A 2 CO
3 CO General purpose relays
- AC & DC coils
55 Series - PCB or Plug-in mounting 94 Series
- Available with lockable test button, mechanical flag & LED indicator
7A 4 CO
Power relays
2 CO - PCB mount or Plug-in mount (Faston 187) or
16 A 2 NO Flange mount (Faston 250)
62 Series 92 Series
3 CO - AC & DC coils
3 NO - NO contacts options, > 3mm contact gap
- LED, mechanical indicator & test button options
20 A 1 NO +
1 NC
Power relays
- AC & DC coils
65 Series
- PCB mount or Flange mount (Faston 250)
- NO version, > 3mm contact gap
30 A 1 NO
Power relays
30 A 2 CO - PCB mount or Flange mount (Faston 250)
66 Series
2 NO - AC & DC coils
- 8mm, 6kV (1.2/50 µs) isolation, coil - contacts
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
30
SERIES
Contact specification
Contact configuration 2 CO (DPDT)
Rated current/Maximum peak current A 2/3
Rated voltage/Maximum switching voltage V AC 125/250
Rated load AC1 VA 125
Rated load AC15 (230 V AC) VA 25
Single phase motor rating (230 V AC) kW —
Breaking capacity DC1: 30/110/220 V A 2/0.3/—
Minimum switching load mW (V/mA) 10 (0.1/1)
Standard contact material AgNi + Au
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) —
V DC 5 - 6 - 9 - 12 - 24 - 48
Rated power AC/DC VA (50 Hz)/W —/0.2
Operating range AC —
DC See table page 3
Holding voltage AC/DC —/0.35 UN
Must drop-out voltage AC/DC —/0.05 UN
Technical data
Mechanical life AC/DC cycles —/10 · 106
Electrical life at rated load AC1 cycles 100 · 103
Operate/release time ms 6/2
X-2013, www.findernet.com
A B C D
Plug-in / PCB Relays
3 0. 2 2 . 7 . 0 1 2 . 0 0 1 0
Series A: Contact material D: Special versions
Type 0 = Standard 0 = Wash tight (RT III)
2 = PCB mount AgNi + Au C: Options
No. of poles B: Contact circuit 1 = None
2 = 2 pole, 2 A 0 = CO (DPDT)
Coil version
7 = Sensitive DC
Coil voltage
See coil specifications
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400 120...240 single phase
Rated insulation voltage V AC 250 125
Pollution degree 1 2
Insulation between coil and contact set
Type of insulation Basic Basic
Overvoltage category I II
Rated impulse voltage kV (1.2/50 µs) 1.5 1.5
Dielectric strength V AC 1,000 1,000
Insulation between adjacent contacts
Type of insulation Basic Basic
Overvoltage category I II
Rated impulse voltage kV (1.2/50 µs) 1.5 1.5
Dielectric strength V AC 1,500 1,500
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 750/1 750/1
Other data
Bounce time: NO/NC ms 1/3
Vibration resistance (5…55)Hz: NO/NC g 15/15
Shock resistance g 16
Power lost to the environment without contact current W 0.2
with rated current W 0.4
Recommended distance between relays mounted on PCB mm ≥ 5
X-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
30
SERIES
Note:
The rated current of 2 A corresponds to the limiting continuous current.
Coil specifications
DC coil data - 0.2 W sensitive R 30 - DC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
5 7.005 3.7 7.5 125 40
6 7.006 4.5 9 180 33
9 7.009 6.7 13.5 405 22
12 7.012 8.4 18 720 16
24 7.024 16.8 36 2,880 8.3
48 7.048 36 72 11,520 4.1
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
32 Series - Subminiature PCB relays 6 A
Features 32.21-x000 32.21-x300
Printed circuit mount 6 A relay
• 1 Pole changeover contacts or
1 Pole normally open contact
• Subminiature, low profile package
• Sensitive DC coil - 200 mW
• Wash tight: RT III
• Cadmium Free contact material option
• 1 CO (SPDT), 6 A • 1 NO (SPST-NO), 6 A
• Low coil power • Low coil power
• PCB mount • PCB mount
Contact specification
Contact configuration 1 CO (SPDT) 1 NO (SPST-NO)
Rated current/Maximum peak current A 6/15 6/15
Rated voltage/Maximum switching voltage V AC 250/400 250/400
Rated load AC1 VA 1,500 1,500
Rated load AC15 (230 V AC) VA 250 250
Single phase motor rating (230 V AC) kW 0.185 0.185
Breaking capacity DC1: 30/110/220 V A 3/0.35/0.2 3/0.35/0.2
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5)
Standard contact material AgCdO AgCdO
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) — —
V DC 5 - 12 - 24 - 48 5 - 12 - 24 - 48
Rated power AC/DC VA (50 Hz)/W —/0.2 —/0.2
Operating range AC — —
DC (0.78...1.5)UN (0.78...1.5)UN
Holding voltage AC/DC —/0.4 UN —/0.4 UN
Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN
Technical data
Mechanical life AC/DC cycles —/20 · 106 —/20 · 106
3
Electrical life at rated load AC1 cycles 100 · 10 100 · 103
Operate/release time ms 6/4 6/2
Insulation between coil and contacts (1.2/50 µs) kV 5 5
Dielectric strength between open contacts V AC 1,000 1,000
Ambient temperature range °C –40…+85 –40…+85
Environmental protection RT III RT III
Approvals (according to type)
1
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
32 Series - Subminiature PCB relays 6 A
Ordering information
Example: 32 series PCB, 1 NO (SPDT-NO) - 6 A contacts, 24 V sensitive DC coil.
A B C D
3 2. 2 1 . 7 . 0 2 4 . 2 3 0 0
Series A: Contact material D: Special versions
Type 2 = Standard AgCdO 0 = Wash tight (RT III)
2 = PCB mount 4 = AgSnO2 C: Options
No. of poles B: Contact circuit 0 = None
1 = 1 pole, 6 A 0 = CO (SPDT)
3 = NO (SPST)
Coil version
7 = Sensitive DC
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type Coil version A B C D
32.21 sens. DC 2-4 0-3 0 0
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400
Rated insulation voltage V AC 250
Pollution degree 2
Insulation between coil and contact set
Type of insulation Basic
Overvoltage category III
Rated impulse voltage kV (1.2/50 µs) 5
Dielectric strength V AC 4,000
Insulation between open contacts
Type of disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 2/10 (changeover) 2/— (normally open)
Vibration resistance (5…55)Hz: NO/NC g 10/10 (changeover) 10/— (normally open)
Shock resistance g 20
Power lost to the environment without contact current W 0.2
with rated current W 0.5
Recommended distance between relays mounted on PCB mm ≥ 5
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
32 Series - Subminiature PCB relays 6 A
Contact specification
F 32 - Electrical life (AC) v contact current H 32 - Maximum DC1 breaking capacity
DC voltage (V)
Coil specifications
DC coil data - 0.2 W sensitive R 32 - DC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
5 7.005 3.9 7.5 125 40
12 7.012 9.4 18 720 16
24 7.024 18.7 36 2,880 8.3
48 7.048 37.4 72 11,520 4
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
34
SERIES
Output circuit
Contact configuration 1 NO (SPST-NO) 1 NO (SPST-NO) 1 NO (SPST-NO)
Rated current/Maximum peak current (10 ms) A 2/20 0.1/0.5 2/40
Rated voltage/Maximum blocking voltage V (24/33)DC (48/60)DC (240/275)AC
Switching voltage range V (1.5...24)DC (1.5...48)DC (12...240)AC
Minimum switching current mA 1 0.05 22
Max. “OFF-state” leakage current mA 0.001 0.001 1.5
Max. “ON-state” voltage drop V 0.12 1 1.6
Input circuit
Nominal voltage V DC 5 12 24 60 24 60 5 12 24 60
Rated power AC/DC W 0.035 0.087 0.17 0.18 0.17 0.18 0.060 0.087 0.17 0.18
Operating range V DC 3.5...12 8...17 16...30 35...72 16...30 35...72 3.5...10 8...17 16...30 35...72
Control current mA 7 7.2 7 3 7 3 12 7.2 7 3
Release voltage V DC 1 4 10 20 10 20 1 4 10 20
Impedance Ω 715 1,940 3,200 21,300 3,200 21,300 416 1,940 3,200 21,300
Technical data
Operate/release time ms 0.1/0.6* 0.04/0.6* 12/12*
Dielectric strength between input/output V 2,500 2,500 2,500
Ambient temperature range °C –20...+60 –20...+60 –20...+60
Environmental protection RT III RT III RT III
Approvals (according to type)
* Note: all technical data relates to using the relay directly on PCB or PCB socket type 93.11.
If the relay is used with 35 mm rail socket type 93.51, refer to the technical data of 38 Series; if used with types 93.61, 93.62, 93.63, 93.64
and 93.68, refer to the technical data of the MasterINTERFACE 39 Series.
X-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
34
SERIES
3 4 . 5 1 . 7 . 0 2 4 . 0 0 1 0
Series A: Contact material D: Special versions
Type 0 = Standard AgNi 0 = Flux proof (RT II)
5 = Electromechanical type 4 = AgSnO2 9 = Flat version
5 = AgNi + Au C: Options
No. of poles
1 = 1 pole, 6 A B: Contact circuit 1 = None
0 = CO (SPDT)
Coil version
3 = NO (SPST)
7 = Sensitive DC
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type Coil version A B C D
34.51 sens. DC 0-4-5 0-3 1 0
34.51 sens. DC 0-4-5 0 1 9
3 4 . 8 1 . 7 . 0 2 4 . 9 0 2 4
Series Output circuit
Type 9024 = 2 A - 24 V DC
8 = SSR type 7048 = 0.1 A - 48 V DC
8240 = 2 A - 240 V AC
Output
1 = 1 NO (SPST-NO)
Input circuit
See input specifications
12
11
14
Environmental protection RT I
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
34
SERIES
Contact specification
F 34 - Electrical life (AC) v contact current H 34 - Maximum DC1 breaking capacity
DC breaking current (A)
DC voltage (V)
Coil specifications
DC coil data R 34 - DC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
5 7.005 3.5 7.5 130 38.4
12 7.012 8.4 18 840 14.2
24 7.024 16.8 36 3,350 7.1
48 7.048 33.6 72 12,300 3.9
X-2013, www.findernet.com
60 7.060 42 90 19,700 3
Input specification
Input data - DC types
Nominal Input Operating range Release Impedance Control
voltage code voltage current
UN Umin Umax I at UN
V V V V Ω mA
5 7.005 3.5 12 (10*) 1 715 (416*) 7 (12*)
12 7.012 8 17 4 1,940 7.2
24 7.024 16 30 10 3,200 7
60 7.060 35 72 20 21,300 3
* AC Output version.
Output specification
L 34 - Output current v ambient temperature L 34 - Output current v ambient temperature
SSR - 2 A DC & AC output types SSR - 0.1 A DC output types
Output current
Output current
X-2013, www.findernet.com
5
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
34
SERIES
For technical data and supply versions, refer to the MasterINTERFACE 39 Series – “Relay interface module”
Accessories
16-way jumper link 093.16 (blue), 093.16.0 (black), 093.16.1 (red)
Dual-purpose plastic separator 093.60
Sheet of marker tags 060.72
Technical data
Rated values 6 A – 250 V
Dielectric strength 6 kV (1.2/50 μs) between coil and contacts
Protection category IP20
Ambient temperature °C −40…+70
Screw torque Nm 0.5
X-2013, www.findernet.com
6
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
34
SERIES
Certain relay/socket
Electromechanical Relay - EMR and Solid State Relay - SSR
combinations
Relay type (reference with the 38 Series)
Supply voltage Electromechnanical relay - EMR Solid State Relay - SSR Socket type
(38.61…..) (38.81…..)
12 V AC/DC 34.51.7.012.xx10 — 93.51.0.024
24 V AC/DC 34.51.7.024.xx10 — 93.51.0.024
(110…125)V AC/DC 34.51.7.060.xx10 34.81.7.060.xxxx 93.51.0.125
(220…240)V AC/DC 34.51.7.060.xx10 34.81.7.060.xxxx 93.51.0.240
(110…125)V AC/DC * 34.51.7.060.xx10 34.81.7.060.xxxx 93.51.3.125
(220…240)V AC * 34.51.7.060.xx10 34.81.7.060.xxxx 93.51.3.240
(220…240)V AC 34.51.7.060.xx10 34.81.7.060.xxxx 93.51.8.240
12 V DC 34.51.7.012.xx10 34.81.7.012.xxxx 93.51.7.024
24 V DC 34.51.7.024.xx10 34.81.7.024.xxxx 93.51.7.024
60 V DC 34.51.7.060.xx10 34.81.7.060.xxxx 93.51.7.060
* Leakage current suppression
Accessories
20-way jumper link 093.20
Plastic separator 093.01
Sheet of marker tags 093.64
Technical data
Rated values 6 A – 250 V
Dielectric strength 6 kV (1.2/50 μs) between coil and contacts
Protection category IP20
Ambient temperature (UN≤ 60 V/> 60 V) °C −40...+70/−40...+55
Wire strip length mm 10
Max wire size Solid wire and stranded wire
mm2 1 x 2.5 / 2 x 1.5
AWG 1 x 14 / 2 x 16
X-2013, www.findernet.com
7
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
34
SERIES
(+) (A)
X-2013, www.findernet.com
8
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
36
SERIES
• 1 CO (SPDT), 10 A
• Sugar cube size
• PCB mount
Contact specification
Contact configuration 1 CO (SPDT)
Rated current/Maximum peak current A 10/15
Rated voltage/Maximum switching voltage V AC 250/250
Rated load AC1 VA 2,500
Rated load AC15 (230 V AC) VA 500
Single phase motor rating (230 V AC) kW 0.37
Breaking capacity DC1: 30/110/220 V A 10/0.3/0.12
Minimum switching load mW (V/mA) 500 (5/100)
Standard contact material AgSnO2
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) —
V DC 3 - 5 - 6 - 9 - 12 - 18 - 24 - 48
Rated power AC/DC VA (50 Hz)/W —/0.36
Operating range AC —
DC (0.75…1.3)UN
Holding voltage AC/DC —/0.4 UN
Must drop-out voltage AC/DC —/0.1 UN
Technical data
Mechanical life AC/DC cycles —/10 · 106
Electrical life at rated load AC1 cycles 50 · 103
Operate/release time ms 10/5
VII-2013, www.findernet.com
1
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
36
SERIES
A B C D
3 6. 1 1 . 9 . 0 1 2 . 4 0 1 1
Series A: Contact material D: Special versions
Type 4 = AgSnO2 1 = Wash tight (RT III)
1 = PCB mount B: Contact circuit C: Options
No. of poles 0 = CO (SPDT) 1 = None
1 = 1 pole, 10 A
Coil version
9 = DC
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400
Rated insulation voltage V AC 250
Pollution degree 2
Insulation between coil and contact set
Type of insulation Basic
Overvoltage category II
Rated impulse voltage kV (1.2/50 µs) 3
Dielectric strength V AC 2,500
Insulation between open contacts
Type of disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 750/1.5
Other data
Shock resistance g 10
Bounce time: NO/NC ms 1/6
Vibration resistance (5...55Hz): NO/NC g 14/8
Power lost to the environment
without contact current W 0.4
with rated current W 1.4
Recommended distance between relays mounted on PCB mm ≥ 5
VII-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
36
SERIES
DC voltage (V)
Coil specifications
DC coil data R 36 - DC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
3 9.003 2.2 3.9 25 120
5 9.005 3.7 6.5 70 72
6 9.006 4.5 7.8 100 60
9 9.009 6.7 11.7 225 40
12 9.012 9 15.6 400 30
18 9.018 13.5 23.4 900 20
24 9.024 18 31.2 1,600 15
48 9.048 36 62.4 6,400 7.5
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
VII-2013, www.findernet.com
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Contact specification
Contact configuration 1 CO (SPDT) 1 CO (SPDT)
Rated current/Maximum peak current A 12/20 16/30
Rated voltage/Maximum switching voltage V AC 250/400 250/400
Rated load AC1 VA 3,000 4,000
Rated load AC15 (230 V AC) VA 1,000 1,000
Single phase motor rating (230 V AC) kW 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 12/0.3/0.12 16/0.3/0.12
Minimum switching load mW (V/mA) 300 (5/5) 500 (10/5)
Standard contact material AgNi AgCdO
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) — —
V DC 12 - 24 12 - 24
Rated power DC/sensitive DC W 0.65/0.5 0.65/0.5
Operating range AC — —
DC/sensitive DC (0.73…1.5)UN/(0.73…1.5)UN (0.73...1.5)UN/(0.8…1.5)UN
Holding voltage DC 0.4 UN 0.4 UN
Must drop-out voltage DC 0.1 UN 0.1 UN
Technical data
Mechanical life AC/DC cycles 10 · 106 10 · 106
Electrical life at rated load AC1 cycles 200 · 103 100 · 103
Operate/release time ms 7/3 (10/3 sensitive) 7/3 (10/3 sensitive)
IV-2013, www.findernet.com
A B C D
4 0 . 3 1 . 7 . 0 2 4 . 1 0 2 0
Series A: Contact material D: Special versions
0 = AgNi 0 = Standard flux proof (RT II)
Type
(40.31 Plug-in relays) 1 = Wash tight (RT III)
3 = PCB - 3.5 mm pinning
0 = AgCdO
6 = PCB - 5 mm pinning C: Options
(40.61 Plug-in relays)
No. of poles 0 = Pins length 5.3 mm (Plug-in relays)
1 = AgNi (PCB relays)
1 = 1 pole 2 = Pins length 3.5 mm (PCB relays)
2 = AgCdO
for: 40.31, 12 A (40.61 PCB relays)
40.61, 16 A
B: Contact circuit
Coil version 0 = CO (SPDT)
7 = Sensitive DC 3 = NO (SPST)
9 = Standard DC
Coil voltage
012 = 12 V DC
024 = 24 V DC
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Terminal pin Type Coil version A B C D
PCB-relay, pin length 3.5 mm 40.31 DC/DC sensitive 1 0-3 2 0-1
PCB-relay, pin length 3.5 mm 40.61 DC/DC sensitive 1 - 2 0-3 2 0-1
Plug in relay, pin length 5.3 mm 40.31 DC/DC sensitive 0 0-3 0 0-1
Plug in relay, pin length 5.3 mm 40.61 DC/DC sensitive 0 0-3 0 0-1
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400
Rated insulation voltage V AC 250 400
Pollution degree 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm)
Overvoltage category III
Rated impulse voltage kV (1.2/50 μs) 6
Dielectric strength V AC 4,000
Insulation between open contacts
Type of disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 μs) 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 μs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 2/5
Vibration resistance (10…200)Hz: NO/NC g 20/5
Shock resistance NO/NC g 20/5
Power lost to the environment without contact current W 0.5
with rated current W 1.2 (40.31) 1.8 (40.61)
Recommended distance between relays mounted on PCB mm ≥ 5
IV-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
** Inductive
load - AC15
DC voltage (V)
* Inductive load - cosϕ = 0.4: inrush current = rated current • When switching a resistive load (DC1) having voltage and current
** Inductive load - AC15: inrush current = 10 x rated current values under the curve, an electrical life of ≥ 100·103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Coil specifications
DC coil data - 0.5 W sensitive (type 40.31) DC coil data - 0.5 W sensitive (type 40.61)
Nominal Coil Operating range Resistance Rated coil Nominal Coil Operating range Resistance Rated coil
voltage code consumption voltage code consumption
UN Umin Umax R I at UN UN Umin Umax R I at UN
V V V Ω mA V V V Ω mA
12 7.012 8.8 18 288 42 12 7.012 9.6 18 288 42
24 7.024 17.5 36 1,150 21 24 7.024 19.2 36 1,150 21
R 40 - DC coil operating range v ambient temperature R 40 - DC coil operating range v ambient temperature
(sensitive coil, 0.5 W) (standard coil, 0.65 W)
40.61
40.31
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
FOR UL RATINGS SEE: Copper side view Copper side view Copper side view
“General technical information” page V
Contact specification
Contact configuration 1 CO (SPDT) 1 CO (SPDT) 2 CO (DPDT)
Rated current/Maximum peak current A 10/20 10/20 8/15
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400
Rated load AC1 VA 2,500 2,500 2,000
Rated load AC15 (230 V AC) VA 500 500 400
Single phase motor rating (230 V AC) kW 0.37 0.37 0.3
Breaking capacity DC1: 30/110/220 V A 10/0.3/0.12 10/0.3/0.12 8/0.3/0.12
Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
V DC 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - 24 - 28 - 36 - 48 - 60 - 90 - 110 - 125
Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.2/0.65/0.5 1.2/0.65/0.5
Operating range AC (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN
DC/sens. DC (0.73…1.5)UN/(0.73…1.75)UN (0.73…1.5)UN/(0.73…1.75)UN (0.73…1.5)UN/(0.73…1.75)UN
Holding voltage AC/DC 0.8 UN /0.4 UN 0.8 UN /0.4 UN 0.8 UN /0.4 UN
Must drop-out voltage AC/DC 0.2 UN /0.1 UN 0.2 UN /0.1 UN 0.2 UN /0.1 UN
Technical data
Mechanical life AC/DC cycles 10 · 106/20 · 106 10 · 106/20 · 106 10 · 106/20 · 106
Electrical life at rated load AC1 cycles 200 · 103 200 · 103 100 · 103
Operate/release time ms 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive)
X-2013, www.findernet.com
Insulation between coil and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm)
Dielectric strength between open contacts V AC 1,000 1,000 1,000
Ambient temperature range °C –40…+85 –40…+85 –40…+85
Environmental protection RT II** RT II** RT II**
Approvals (according to type)
1
**Engineering,
Courtesy of Steven See general Inc.technical information
- 230 Ryan Way, South“Guidelines forCA
San Francisco, automatic flow- Main
94080-5370 solder processes”
Office: page II- Outside
(650) 588-9200 . Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
40.31.6...
40.51.6...
40.52.6...
40.61.6...
For wiring diagrams see
page 8
40.11
40.41
FOR UL RATINGS SEE: Copper side view Copper side view Copper side view
“General technical information” page V
Contact specification
Contact configuration 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT)
Rated current/Maximum peak current A 10/20 16/30 10/20
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400
Rated load AC1 VA 2,500 4,000 2,500
Rated load AC15 (230 V AC) VA 500 750 500
Single phase motor rating (230 V AC) kW 0.37 0.55 0.37
Breaking capacity DC1: 30/110/220 V A 10/0.3/0.12 16/0.3/0.12 10/0.3/0.12
Minimum switching load mW (V/mA) 300 (5/5) 500 (10/5) 300 (5/5)
Standard contact material AgCdO AgCdO AgCdO
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) — — —
V DC 6 - 12 - 24 - 48 - 60 6 - 12 - 24 - 48 6 - 12 - 24 - 48 - 60
Rated power AC/DC/sens. DC VA (50 Hz)/W/W —/—/0.5 —/—/0.5 —/—/0.5
Operating range AC — — —
DC/sens. DC —/(0.73…1.75)UN —/(0.73…1.5)UN —/(0.73…1.75)UN
Holding voltage AC/DC —/0.4 UN —/0.4 UN —/0.4 UN
Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN —/0.1 UN
Technical data
Mechanical life AC/DC cycles —/20 · 106 —/20 · 106 —/20 · 106
Electrical life at rated load AC1 cycles 200 · 103 50 · 103 200 · 103
Operate/release time ms 12/4 12/4 12/4
X-2013, www.findernet.com
Insulation between coil and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm)
Dielectric strength between open contacts V AC 1,000 1,000 1,000
Ambient temperature range °C –40…+70 –40…+70 –40…+70
Environmental protection RT I RT I RT I
Approvals (according to type)
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
A B C D
Plug-in / PCB Relays
4 0 . 5 2 . 8 . 2 3 0 . 0 0 0 0
Series A: Contact material D: Special versions
0 = Standard AgNi 0 = Standard
Type
for 40.31/51/52, 1 = Wash tight (RT III)
1 = PCB - 3.5 mm pinning, flat
AgCdO for 40.61 3 = High temperature (+ 125 °C) wash tight
3 = PCB - 3.5 mm pinning
2 = AgCdO (standard
4 = PCB - 3.5 mm pinning C: Options
for 40.11/41)
5 = PCB - 5 mm pinning 0 = None
4 = AgSnO2
6 = PCB - 5 mm pinning 16 = With rated current 16 A (for 40.11)
5 = AgNi + Au
No. of poles
1 = 1 pole B: Contact circuit
for: 40.11, 10 A/16 A 0 = CO (nPDT)
40.31, 10 A 3 = NO (nPST)
40.41, 10 A
40.51, 10 A
40.61, 16 A
2 = 2 pole
for: 40.52, 8 A
Coil version Selecting features and options: only combinations in the same row are possible.
6 = AC/DC bistable Preferred selections for best availability are shown in bold.
7 = Sensitive DC
8 = AC (50/60 Hz) Type Coil version A B C D
9 = DC 40.11 sensitive DC 2-4 0 0 0
Coil voltage 40.11 sensitive DC 2-4 0 16 /
See coil specifications 40.41 sensitive DC 0-2 0-3 0 0
40.31*/51 AC-sens. DC 0-2-5 0-3 0 0-1
40.31/51 DC 0-2-5 0-3 0 0-1-3
40.52 AC-sens. DC 0-2-5 0-3 0 0-1
40.52 DC 0-2-5 0-3 0 0-1-3
40.61* AC-sens. DC 0-4 0-3 0 0-1
40.61 DC 0-4 0-3 0 0-1-3
40.31/51/ bistable 0 0 0 0
52/61
* As the result of a new production line and increased production capacity, the
design/specification of the sensitive DC version will be changed to align with current
PCB relay versions 40.31.7.0xx.xx20 and 40.61.7.0xx.xx20. This changeover will
occur during the first quarter in 2013 for the types mentioned below.
For full technical data refer to data sheet: PCB/Plug-in relays 12 - 16 A.
Code Code
40.31.7.012.0000 40.61.7.012.0000
40.31.7.012.0001 40.61.7.012.0001
40.31.7.012.0300 40.61.7.012.0300
X-2013, www.findernet.com
40.31.7.012.0301 40.61.7.012.0301
40.31.7.024.0000 40.61.7.024.0000
40.31.7.024.0001 40.61.7.024.0001
40.31.7.024.0300 40.61.7.024.0300
40.31.7.024.0301 40.61.7.024.0301
** For 40.31 relays mounted on sockets, the maximum rated current must be limited to 10 A.
4
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
5
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Cycles
Inductive load - cosϕ = 0.4
DC voltage (V)
X-2013, www.findernet.com
6
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
AC coil data (types 40.31/51/52/61) AC/DC coil data - bistable (types 40.31/51/52/61)
Nominal Coil Operating range Resistance Rated coil Nominal Coil Operating range Resistance Rated coil DC: Release
voltage code consumption voltage code consumption resistance**
UN Umin Umax R I at UN (50Hz) UN Umin Umax R I at UN RDC
V V V Ω mA V V V Ω mA Ω
6 8.006 4.8 6.6 21 168 5 6.005 4 5.5 23 215 37
12 8.012 9.6 13.2 80 90 6 6.006 4.8 6.6 33 165 62
24 8.024 19.2 26.4 320 45 12 6.012 9.6 13.2 130 83 220
48 8.048 38.4 52.8 1,350 21 24 6.024 19.2 26.4 520 40 910
60 8.060 48 66 2,100 16.8 48 6.048 38.4 52.8 2,100 21 3,600
110 8.110 88 121 6,900 9.4 110 6.110 88 121 11,000 10 16,500
120 8.120 96 132 9,000 8.4 ** RDC = Resistance in DC, RAC = 1.3 x RDC 1W
230 8.230 184 253 28,000 5
240 8.240 192 264 31,500 4.1
X-2013, www.findernet.com
7
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
R 40 - DC coil operating range v ambient temperature R 40 - AC coil operating range v ambient temperature
Sensitive coil, types 40.11/41
On momentary closure of the SET switch the relay is magnetised through On momentary closure of the SET switch the relay is magnetised and the
the diode and the relay contacts transfer to the set position and remain in relay contacts transfer to the set position and remain in this position.
this position. On momentary closure of the RESET switch the relay is demagnetised
On momentary closure of the RESET switch the relay is demagnetised through limiting resistor (RDC) and the contacts return to the reset position.
X-2013, www.findernet.com
through limiting resistor (RAC) and the contacts return to the reset position.
Notes: The minimum SET or RESET impulse time is 20 ms. The maximum time can be continuous. In practice, always ensure that the SET and RESET
contacts cannot be operated simultaneously.
8
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
95.55.3
See page 14
9
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.03 (blue) 95.03.0 (black) 95.05 (blue) 95.05.0 (black)
For relay type 40.31 40.51, 40.52, 40.61
Accessories
Plug-in / PCB Relays
11 COM
Total socket current (A)
14 NO
12 NC
A2 A1 COIL
95.03 95.05
PEAN
O 8-way jumper link for 95.03 and 95.05 sockets 095.18 (blue) 095.18.0 (black)
EUR
T
N
T E
Rated values 10 A - 250 V
EUR
P A O
PEAN
095.18
99.02 coil indication and EMC suppression modules for 95.03 and 95.05 sockets
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
LED (6...24)V DC/AC 99.02.0.024.59
LED (28...60)V DC/AC 99.02.0.060.59
LED (110...240)V DC/AC 99.02.0.230.59
99.02 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
Approvals LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
(according to type): LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Varistor (6...24)V DC/AC 99.02.0.024.98
X-2013, www.findernet.com
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.83.3 (blue) 95.83.30 (black) 95.85.3 (blue) 95.85.30 (black)
For relay type 40.31 40.51, 40.52, 40.61
Accessories
95.83.3 95.85.3
PEAN
O
8-way jumper link for 95.83.3 and 95.85.3 sockets 095.08 (blue) 095.08.0 (black)
EUR
T
N
T E
EUR
095.08
99.80 coil indication and EMC suppression modules for 95.83.3 and 95.85.3 sockets
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.80.3.000.00
LED (6...24)V DC/AC 99.80.0.024.59
LED (28...60)V DC/AC 99.80.0.060.59
99.80
LED (110...240)V DC/AC 99.80.0.230.59
Approvals
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99
LED + Varistor (6...24)V DC/AC 99.80.0.024.98
* Modules in Black LED + Varistor (28...60)V DC/AC 99.80.0.060.98
housing are
X-2013, www.findernet.com
11
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Screw (Box clamp) terminal socket panel or 35 mm rail mount 95.93.3 (blue) 95.93.30 (black) 95.95.3 (blue) 95.95.30 (black)
For relay type 40.31 40.51, 40.52, 40.61
Accessories
Plug-in / PCB Relays
95.93.3 95.95.3
PEAN
O
8-way jumper link for 95.93.3 and 95.95.3 sockets 095.08 (blue) 095.08.0 (black)
EUR
T
N
T E
EUR
P A
PEAN
O Rated values 10 A - 250 V
095.08
99.80 coil indication and EMC suppression modules for 95.93.3 and 95.95.3 sockets
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.80.3.000.00
LED (6...24)V DC/AC 99.80.0.024.59
LED (28...60)V DC/AC 99.80.0.060.59
99.80
LED (110...240)V DC/AC 99.80.0.230.59
Approvals
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99
LED + Varistor (6...24)V DC/AC 99.80.0.024.98
* Modules in Black LED + Varistor (28...60)V DC/AC 99.80.0.060.98
housing are
X-2013, www.findernet.com
12
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Screwless terminal socket panel or 35 mm rail mount 95.55 (blue) 95.55.0 (black)
For relay type 40.51, 40.52, 40.61
Accessories
060.72
86.30 Approvals
(according to type):
99.02 coil indication and EMC suppression modules for 95.55 socket
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
LED (6...24)V DC/AC 99.02.0.024.59
LED (28...60)V DC/AC 99.02.0.060.59
LED (110...240)V DC/AC 99.02.0.230.59
99.02 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
Approvals LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
(according to type): LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Varistor (6...24)V DC/AC 99.02.0.024.98
LED + Varistor (28...60)V DC/AC 99.02.0.060.98
LED + Varistor (110...240)V DC/AC 99.02.0.230.98
DC Modules with RC circuit (6...24)V DC/AC 99.02.0.024.09
non-standard polarity RC circuit (28...60)V DC/AC 99.02.0.060.09
X-2013, www.findernet.com
13
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Screwless terminal socket panel or 35 mm rail mount 95.55.3 (blue) 95.55.30 (black)
For relay type 40.51, 40.52, 40.61
Accessories
Plug-in / PCB Relays
060.72 24.6 4 4
30. 6
24 NO 14
Total socket current (A)
22 NC 12
95. 6
34.7
Ø 3.2
37. 2
30.3
A2 COIL A1
15.8 22.6
32.5
99.80 coil indication and EMC suppression modules for 95.55.3 socket
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.80.3.000.00
LED (6...24)V DC/AC 99.80.0.024.59
LED (28...60)V DC/AC 99.80.0.060.59
99.80
LED (110...240)V DC/AC 99.80.0.230.59
Approvals
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99
LED + Varistor (6...24)V DC/AC 99.80.0.024.98
* Modules in Black LED + Varistor (28...60)V DC/AC 99.80.0.060.98
housing are LED + Varistor (110...240)V DC/AC 99.80.0.230.98
available on request.
RC circuit (6...24)V DC/AC 99.80.0.024.09
Green LED is standard. RC circuit (28...60)V DC/AC 99.80.0.060.09
Red LED available RC circuit (110...240)V DC/AC 99.80.0.230.09
on request.
Residual current by-pass (110...240)V AC 99.80.8.230.07
X-2013, www.findernet.com
14
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
40
SERIES
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.63 (blue) 95.65 (blue)
For relay type 40.31 40.51, 40.52, 40.61
Accessories
95.63 95.65
PEAN
O
8-way jumper link for 95.63 and 95.65 sockets 095.08 (blue)
EUR
T
N
T E
EUR
P A
PEAN
O
Rated values 10 A - 250 V
095.08
99.01 coil indication and EMC suppression modules for type 95.63 socket
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.01.3.000.00
Diode (+A2, non-standard polarity) (6...220)V DC 99.01.2.000.00
99.01 LED (6...24)V DC/AC 99.01.0.024.59
Approvals LED (28...60)V DC/AC 99.01.0.060.59
(according to type): LED (110...240)V DC/AC 99.01.0.230.59
LED + Diode (+A1, standard polarity) (6...24)V DC 99.01.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.01.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.01.9.220.99
LED + Diode (+A2, non-standard polarity) (6...24)V DC 99.01.9.024.79
LED + Diode (+A2, non-standard polarity) (28...60)V DC 99.01.9.060.79
LED + Diode (+A2, non-standard polarity) (110...220)V DC 99.01.9.220.79
LED + Varistor (6...24)V DC/AC 99.01.0.024.98
X-2013, www.findernet.com
PCB socket 95.13.2 (blue) 95.13.20 (black) 95.15.2 (blue) 95.15.20 (black)
For relay type 40.31, 40.41 40.51, 40.52, 40.61
Accessories
Plug-in / PCB Relays
95.13.2 Metal retaining clip (supplied with socket - packaging code SMA) 095.51
Plastic retaining clip 095.52
Technical data
Rated values 10 A - 250 V *
Dielectric strength 6 kV (1.2/50 µs) between coil and contacts
Protection category IP 20
95.15.2
Ambient temperature °C –40…+70
Approvals
(according to type): * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).
With the relay 40.51 the change-over contact will be 21-12-14.
40.31 40.51
13
7.5 12 14 22 24
3.5
A1 12 11 14
30
11 21
20
3.5
A2 22 21 24
A1 A2
1.5
40.52
95.13.2 95.15.2
40.61
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
9 5 . 0 5 S P A
A Standard packaging
16
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
FOR UL RATINGS SEE: Copper side view Copper side view Copper side view
“General technical information” page V
Contact specification
Contact configuration 1 CO (SPDT) 2 CO (DPDT) 1 CO (SPDT)
Rated current/Maximum peak current A 12/25 8/15 16/30
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400
Rated load AC1 VA 3,000 2,000 4,000
Rated load AC15 (230 V AC) VA 600 400 750
Single phase motor rating (230 V AC) kW 0.5 0.3 0.5
Breaking capacity DC1: 30/110/220 V A 12/0.3/0.12 8/0.3/0.12 16/0.3/0.12
Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) 24 - 230 24 - 230 24 - 230
V DC 5 - 6 - 12 - 24 - 48 - 60 - 110 5 - 6 - 12 - 24 - 48 - 60 - 110 5 - 6 - 12 - 24 - 48 - 60 - 110
Rated power AC/DC VA (50 Hz)/W 0.75/0.4 0.75/0.4 0.75/0.4
Operating range AC (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN
DC (0.7...1.5)UN (0.7...1.5)UN (0.7...1.5)UN
Holding voltage AC/DC 0.8/0.4UN 0.8/0.4 UN 0.8/0.4 UN
Must drop-out voltage AC/DC 0.15/0.1UN 0.15/0.1 UN 0.15/0.1 UN
Technical data
Mechanical life AC/DC cycles 10·106/10·106 10·106/10·106 10·106/10·106
Electrical life at rated load AC1 cycles 60 · 103 60 · 103 50 · 103
Operate/release time ms 5/4 5/4 5/4
X-2013, www.findernet.com
Insulation between coil and contacts (1.2/50 μs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm)
Dielectric strength between open contacts V AC 1,000 1,000 1,000
Ambient temperature range °C –40…+70 (AC); +85 (DC) –40…+70 (AC); +85 (DC) –40…+70 (AC); +85 (DC)
Environmental protection RT II RT II RT II
Approvals (according to type)
1
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
Output circuit
Contact configuration 1 NO (SPST-NO) 1 NO (SPST-NO)
Rated current/Maximum peak current (10 ms) A 5/40 3/40
Rated voltage/Maximum blocking voltage V (24/35)DC (240/275)AC
Switching voltage range V (1.5...24)DC (12...240)AC
Minimum switching current mA 1 50
Max. “OFF-state” leakage current mA 0.01 1
Max. “ON-state” voltage drop V 0.3 1.1
Input circuit
Nominal voltage V DC 12 24 12 24
Operating range V DC 8...17 14...32 8...17 14...32
Control current mA 5.5 9 8.8 9
Release voltage V DC 4 9 4 9
Impedance Ω 1,550 2,600 1,030 2,600
Technical data
Operate/release time ms 0.05/0.25 10/10
Dielectric strength between input/output V AC 2,500 2,500
Ambient temperature range °C –20...+60 –20...+60
Environmental protection RT III RT III
Approvals (according to type)
X-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
4 1 . 5 2 . 9 . 0 2 4 . 0 0 1 0
Series A: Contact material D: Special versions
Type 0 = Standard AgNi 0 = Flux proof (RT II)
3 = PCB - 3.5 mm pinning 4 = AgSnO2 1 = Wash tight (RT III)
5 = PCB - 5 mm pinning 5 = AgNi + Au C: Options
6 = PCB - 5 mm pinning B: Contact circuit 0 = Production line 0
No. of poles 0 = CO (nPDT) 1 = Production line 1
1 = 1 pole for 3 = NO (nPST)
41.31, 12 A
41.61, 16 A
2 = 2 pole for
41.52, 8 A
Coil version
8 = AC
9 = DC
Coil voltage Selecting features and options: only combinations in the same row are possible.
See coil specifications Preferred selections for best availability are shown in bold.
Type Coil version A B C D
41.31 DC 0-4-5 0-3 1 0-1
41.52 DC 0-5 0-3 1 0-1
41.61 DC 0-4 0-3 1 0-1
41.31/52/61 AC 0 0 0 0
4 1 . 8 1 . 7 . 0 2 4 . 9 0 2 4
Series Output circuit
Type 9024 = 5 A - 24 V DC
8 = SSR type 8240 = 3 A - 240 V AC
Output
1 = 1 NO (SPST-NO)
Input circuit
See input specifications
X-2013, www.findernet.com
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
1 pole 2 pole
Nominal voltage of supply system V AC 230/400 230/400
Rated insulation voltage V AC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm) Reinforced (8 mm)
Overvoltage category III III
Rated impulse voltage kV (1.2/50 μs) 6 6
Dielectric strength V AC 4,000 4,000
Insulation between adjacent contacts
Type of insulation — Basic
Overvoltage category — III
Rated impulse voltage kV (1.2/50 μs) — 4
Dielectric strength V AC — 2,000
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 μs) 1,000/1.5 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 μs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 2/5
Vibration resistance (5…55)Hz: NO/NC g 15/2
Shock resistance g 16
Power lost to the environment without contact current W 0.4
with rated current W 1.7 (41.31) 1.2 (41.52) 1.8 (41.61)
Recommended distance between relays mounted on PCB mm ≥ 5
X-2013, www.findernet.com
4
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
Cycles
limit for 41.31
single contact
• When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
DC voltage (V)
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Coil specifications
AC coil data R 41 - AC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
24 8.024 19.2 26.4 350 31.6
230 8.230 184 253 32,500 3.2
Input specification
Input data - DC types
Nominal Input Operating range Release Impedance Control
voltage code voltage current
UN Umin Umax I at UN
V V V V Ω mA
12 7.012 8 17 4 1,550 5.5
24 7.024 14 32 9 2,600 9
Output specification
L 41 - Output current v ambient temperature L 41 - Output current v ambient temperature
SSR - 5 A DC output types SSR - 3 A AC output types
Output current
Output current
X-2013, www.findernet.com
6
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
7
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
Accessories
PEAN
O 8-way jumper link for 93.02 and 93.52 sockets 093.08 (blue) 093.08.0 (black) 093.08.1 (red)
EUR
T
N
T E Rated values 10 A - 250 V
EUR
P A O
PEAN
093.08
Approvals
(according to type):
060.72
8
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
41
SERIES
PCB socket 95.13.2 (blue) 95.13.20 (black) 95.15.2 (blue) 95.15.20 (black)
For relay type 41.31 41.52, 41.61, 41.81(1)
Accessories
Approvals * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).
(1)
(according to type): With the relay 41.81 the NO change-over contact will be 11-14.
13
7.5
3.5
30
20
3.5
95.13.2 95.15.2
Copper side view Copper side view
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
9 5 . 1 3 . 2 S L A
A Standard packaging
9
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
43
SERIES
43.41
43.41-0300
43.61-0300
FOR UL RATINGS SEE: Copper side view Copper side view Copper side view
“General technical information” page V
Contact specification
Contact configuration 1 CO (SPDT) 1 NO (SPST-NO) 1 NO (SPST-NO)
Rated current/Maximum peak current A 10/15 10/15 16/25
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400
Rated load AC1 VA 2,500 2,500 4,000
Rated load AC15 (230 V AC) VA 500 500 750
Single phase motor rating (230 V AC) kW — — —
Breaking capacity DC1: 30/110/220 V A 10/0.3/0.12 10/0.3/0.12 16/0.3/0.12
Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) — — —
V DC 3 - 6 - 9 - 12 - 18 - 24 - 36 - 48 3 - 6 - 9 - 12 - 18 - 24 - 36 - 48 12 - 24 - 48
Rated power AC/DC VA (50 Hz)/W —/0.25 —/0.25 —/0.4
Operating range AC — — —
DC (0.7…1.5)UN (0.7…1.5)UN (0.7…1.2)UN
Holding voltage AC/DC —/0.4 UN —/0.4 UN —/0.4 UN
Must drop-out voltage AC/DC —/0.05 UN —/0.05 UN —/0.05 UN
Technical data
Mechanical life AC/DC cycles —/10 · 106 —/10 · 106 —/10 · 106
Electrical life at rated load AC1 cycles 100 · 103 100 · 103 50 · 103
Operate/release time ms 6/4 6/2 6/2
X-2013, www.findernet.com
Insulation between coil and contacts (1.2/50 µs) kV 6 (10 mm) 6 (10 mm) 6 (10 mm)
Dielectric strength between open contacts V AC 1,000 1,000 1,000
Ambient temperature range °C –40…+85 –40…+85 –40…+85
Environmental protection RT II RT II RT II
Approvals (according to type)
1
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
43
SERIES
A B C D
4 3 . 4 1 . 7 . 0 2 4 . 2 0 0 0
Series A: Contact material D: Special versions
Type 0 = AgNi 0 = Flux proof (RT II)
4 = PCB - 3.2 mm pinning 2 = AgCdO 1 = Wash tight (RT III)
(CO/SPDT, 10 A) 4 = AgSnO2 C: Options
PCB - 5 mm pinning 5 = AgNi + Au 0 = None
(NO/SPST-NO, 10 A) B: Contact circuit
6 = PCB - 5 mm pinning 0 = CO (SPDT) - (for 43.41 only)
(NO/SPST-NO, 16 A) 3 = NO (SPST)
No. of poles
1 = 1 pole
Coil version
7 = Sensitive DC (only for 43.41)
Selecting features and options: only combinations in the same row are possible.
9 = DC (only for 43.61)
Preferred selections for best availability are shown in bold.
Coil voltage
See coil specifications Type Coil version A B C D
43.41 sensitive DC 0-2-4-5 0-3 0 0-1
43.61 DC 0-2-4 3 0 0
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400
Rated insulation voltage V AC 250 400
Pollution degree 3 2
Insulation between coil and contact set
Type of insulation Reinforced (10 mm)
Overvoltage category III
Rated impulse voltage kV (1.2/50 µs) 6
Dielectric strength V AC 4,000
Insulation between open contacts
Type of disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 3/6
Vibration resistance (5…55)Hz: NO/NC g 15/3
Shock resistance g 15
Power lost to the environment without contact current W 0.25 (43.41) 0.4 (43.61)
with rated current W 1.3 (43.41) 2 (43.61)
Recommended distance between relays mounted on PCB mm ≥ 5
X-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
43
SERIES
DC voltage (V)
Coil specifications
DC coil data - 0.25 W sensitive (type 43.41) R 43 - DC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
3 7.003 2.2 4.5 36 83.5
6 7.006 4.2 9 150 40
9 7.009 6.5 13.5 324 27.7
12 7.012 8.4 18 580 20.7
18 7.018 13 27 1,300 13.8
24 7.024 16.8 36 2,200 10.9
36 7.036 25.2 54 5,200 6.9
48 7.048 33.6 72 9,200 5.2
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
DC coil data - 0.4 W standard (type 43.61)
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
12 9.012 8.4 14.4 360 33.3
24 9.024 16.8 28.8 1,400 17.1
48 9.048 33.6 57.6 5,760 8.3
X-2013, www.findernet.com
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
43
SERIES
PCB socket (for changeover contacts only) 95.23 (blue) 95.23.0 (black)
For relay type 43.41 43.41
Accessories
Plug-in / PCB Relays
95.23 Metal retaining clip (supplied with socket - packaging code SNA) 095.43
Approvals Technical data
(according to type): Rated values 10 A - 250 V
Insulation 6 kV (1.2/50 µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70
43.41
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
9 5 . 2 3 S N A
A Standard packaging
X-2013, www.findernet.com
4
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
29 12.4
25
0.4 1
5
A B C D
Plug-in / PCB Relays
4 4 . 6 2 . 9 . 0 2 4 . 0 0 0 0
Series A: Contact material D: Special versions
Type 0 = Standard AgNi 0 = Flux proof (RT II)
5 = PCB - 5 mm pinning 4 = AgSnO2 C: Options
6 = PCB - 5 mm pinning for 44.62 only 0 = None
5 = AgNi + Au
No. of poles for 44.52 only
2 = 2 pole for
44.52, 6 A B: Contact circuit
44.62, 10 A 0 = CO (DPDT)
Coil version
7 = Sensitive DC
9 = DC
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type Coil version A B C D
44.52 DC - sens. DC 0-5 0 0 0
44.62 DC - sens. DC 0-4 0 0 0
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400
Rated insulation voltage V AC 250 400
Pollution degree 3 2
Insulation between coil and contact set
Type of Insulation Reinforced (8 mm)
Overvoltage category III
Rated impulse voltage kV (1.2/50 µs) 6
Dielectric strength V AC 4,000
Insulation between adjacent contacts
Type of insulation Basic
Overvoltage category III
Rated impulse voltage kV (1.2/50 µs) 4
Dielectric strength V AC 2,500
Insulation between open contacts
Type of disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 4/4
Vibration resistance (5…55)Hz: NO/NC g 15/12
Shock resistance g 16
Power lost to the environment without contact current W 0.6
with rated current W 1.2 (44.52) 2.7 (44.62)
X-2013, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
single contact
limit for 44.52
DC voltage (V)
Coil specifications
DC coil data - 0.65 W standard DC coil data - 0.5 W sensitive
Nominal Coil Operating range Resistance Rated coil Nominal Coil Operating range Resistance Rated coil
voltage code consumption voltage code consumption
UN Umin Umax R I at UN UN Umin* Umax R I at UN
V V V Ω mA V V V Ω mA
6 9.006 4.4 9 55 109 6 7.006 4.4 10.2 75 80
9 9.009 6.6 13.5 125 72 9 7.009 6.6 15.3 160 56
12 9.012 8.8 18 220 55 12 7.012 8.8 20.4 300 40
14 9.014 10.2 21 300 47 14 7.014 10.2 23.8 400 35
24 9.024 17.5 36 900 27 24 7.024 17.5 40.8 1,200 20
28 9.028 20.5 42 1,200 23 28 7.028 20.5 47.6 1,600 17.5
48 9.048 35 72 3,500 14 48 7.048 35 81.6 4,800 10
60 9.060 43.8 90 5,500 11 60 7.060 43.8 102 7,200 8.4
110 9.110 80.3 165 18,000 6.2 110 7.110 80.3 187 23,500 4.7
125 9.125 91.2 188 23,500 5.3 125 7.125 100 219 32,000 3.9
*Umin = 0.8 UN for 44.62
R 44 - DC coil operating range v ambient temperature R 44 - DC coil operating range v ambient temperature
Standard coil Sensitive coil
X-2013, www.findernet.com
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
95.85.3
See page 6
95.95.3
See page 7
95.55.3
See page 9
95.65
See page 10
Bottom
terminals
4
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.05 (blue) 95.05.0 (black)
For relay type 44.52, 44.62
Accessories
PEAN
O
8-way jumper link for 95.05 socket 095.18 (blue) 095.18.0 (black)
EUR
T
N
T E
EUR
095.18
86.30
99.02 coil indication and EMC suppression modules for 95.05 socket
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
LED (6...24)V DC/AC 99.02.0.024.59
LED (28...60)V DC/AC 99.02.0.060.59
LED (110...240)V DC/AC 99.02.0.230.59
99.02 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
Approvals LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
(according to type): LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Varistor (6...24)V DC/AC 99.02.0.024.98
X-2013, www.findernet.com
5
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.85.3 (blue) 95.85.30 (black)
For relay type 44.52, 44.62
Accessories
Plug-in / PCB Relays
060.72
PEAN
O
8-way jumper link for 95.85.3 socket 095.08 (blue) 095.08.0 (black)
EUR
T
N
T E
EUR
P A
PEAN
O
Rated values 10 A - 250 V
095.08
99.80 coil indication and EMC suppression modules for 95.85.3 socket
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.80.3.000.00
LED (6...24)V DC/AC 99.80.0.024.59
LED (28...60)V DC/AC 99.80.0.060.59
99.80
LED (110...240)V DC/AC 99.80.0.230.59
Approvals
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99
LED + Varistor (6...24)V DC/AC 99.80.0.024.98
* Modules in Black LED + Varistor (28...60)V DC/AC 99.80.0.060.98
X-2013, www.findernet.com
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.95.3 (blue) 95.95.30 (black)
For relay type 44.52, 44.62
Accessories
060.72
PEAN
O
EUR
T E
N
T
8-way jumper link for 95.95.3 socket 095.08 (blue) 095.08.0 (black)
EUR
P A
Rated values 10 A - 250 V
O
PEAN
095.08
99.80 coil indication and EMC suppression modules for 95.95.3 socket
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.80.3.000.00
LED (6...24)V DC/AC 99.80.0.024.59
LED (28...60)V DC/AC 99.80.0.060.59
99.80
LED (110...240)V DC/AC 99.80.0.230.59
Approvals
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99
LED + Varistor (6...24)V DC/AC 99.80.0.024.98
* Modules in Black LED + Varistor (28...60)V DC/AC 99.80.0.060.98
X-2013, www.findernet.com
Screwless terminal socket panel or 35 mm rail mount 95.55 (blue) 95.55.0 (black)
For relay type 44.52, 44.62
Accessories
Plug-in / PCB Relays
060.72
86.30
99.02 coil indication and EMC suppression modules for 95.55 socket
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
LED (6...24)V DC/AC 99.02.0.024.59
LED (28...60)V DC/AC 99.02.0.060.59
LED (110...240)V DC/AC 99.02.0.230.59
99.02 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
Approvals LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
(according to type): LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Varistor (6...24)V DC/AC 99.02.0.024.98
LED + Varistor (28...60)V DC/AC 99.02.0.060.98
X-2013, www.findernet.com
8
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
Screwless terminal socket panel or 35 mm rail mount 95.55.3 (blue) 95.55.30 (black)
For relay type 44.52, 44.62
Accessories
73.7
24.6 4 4
060.72
21 COM 11
30. 6
L 95 - Total socket current vs ambient temperature 24 NO 14
22 NC 12
Total socket current (A)
95. 6
Ø 3.2 34.7
37. 2
30.3
A2 COIL A1
15.8 22.6
32.5
99.80 coil indication and EMC suppression modules for 95.55.3 socket
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.80.3.000.00
LED (6...24)V DC/AC 99.80.0.024.59
LED (28...60)V DC/AC 99.80.0.060.59
99.80
LED (110...240)V DC/AC 99.80.0.230.59
Approvals
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99
* Modules in Black LED + Varistor (6...24)V DC/AC 99.80.0.024.98
housing are LED + Varistor (28...60)V DC/AC 99.80.0.060.98
available on request.
LED + Varistor (110...240)V DC/AC 99.80.0.230.98
Green LED is standard. RC circuit (6...24)V DC/AC 99.80.0.024.09
Red LED available RC circuit (28...60)V DC/AC 99.80.0.060.09
on request. RC circuit (110...240)V DC/AC 99.80.0.230.09
Residual current by-pass (110...240)V AC 99.80.8.230.07
X-2013, www.findernet.com
9
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
Screw terminal (Box clamp) socket panel or 35 mm rail mount 95.65 (blue)
For relay type 44.52, 44.62
Accessories
Plug-in / PCB Relays
95.65
PEAN
O
8-way jumper link for 95.65 sockets 095.08 (blue)
EUR
T
N
T E
EUR
P A
PEAN
O
Rated values 10 A - 250 V
095.08
X-2013, www.findernet.com
10
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
44
SERIES
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
9 5 . 0 5 S P A
A Standard packaging
11
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
45 Series - Miniature PCB relays 16 A
Features 45.31 45.71 45.91
Relay for +105 °C ambient use
PCB mount - direct for coil and contact terminals
- 45.31, 1 Pole normally open
(≥ 3 mm contact gap)
Relays for +125 °C ambient use
PCB mount - Faston 250 contact connections
- 45.71, 1 Pole normally open or normally closed
- 45.91, 1 Pole normally open
(≥ 3 mm contact gap)
• Contact gap ≥ 3 mm according to •1 NO (SPST-NO), •1 NO or 1 NC •1 NO (SPST-NO),
EN 60730-1 (45.31 and 45.91 type) ≥ 3 mm gap (SPST-NO or SPST-NC) ≥ 3 mm gap
• Sensitive DC coil - 360 mW • Max ambient temperature • Max ambient temperature • Max ambient temperature
45.31...0310 45.91...0310
(1 NO / SPST-NO) (1 NO / SPST-NO)
45.71...0410
(1 NC) / (SPST-NC)
Insulation between coil and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm)
Dielectric strength between open contacts V AC 2,500 1,000 2,500
Ambient temperature range °C –40…+105 –40…+125 –40…+125
Environmental protection RT II RT II RT II
Approvals (according to type)
1
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
45 Series - Miniature PCB relays 16 A
Ordering information
Example: 45 series for PCB relay + Faston 250, 1 NO (SPST-NO), 12 V DC coil.
A B C D
4 5 . 7 1 . 7 . 0 1 2 . 0 3 1 0
Series A: Contact material D: Special versions
Type 0 = Standard AgCdO 0 = Flux proof (RT II)
3 = PCB mount, ≥ 3 mm contact gap for 45.71, 1 = Wash tight (RT III) 45.71 and 45.91 only
7 = PCB + Faston 250 mount Standard AgNi C: Options
9 = PCB + Faston 250 mount, for 45.31 and 1 = None
≥ 3 mm contact gap 45.91
1 = AgNi
No. of poles 2 = AgCdO
1 = 1 pole, 16 A
B: Contact circuit
Coil version
3 = NO (SPST)
7 = Sensitive DC
4 = NC (SPST) 45.71 only
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Type Coil version A B C D
45.31 sensitive DC 0 - 2 3 1 0
45.71 sensitive DC 0 - 1 3-4 1 0-1
45.91 sensitive DC 0 - 2 3 1 0-1
Technical data
Insulation according to EN 61810-1
45.71 45.31 / 45.91
Nominal voltage of supply system V AC 230/400 230/400
Rated insulation voltage V AC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm) Reinforced (8 mm)
Overvoltage category III III
Rated impulse voltage kV (1.2/50 µs) 6 6
Dielectric strength V AC 4,000 4,000
Insulation between open contacts
Type of disconnection Micro-disconnection Full-disconnection
Overvoltage category — III
Rated impulse voltage kV (1.2/50 µs) — 4
Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5 2,500/4
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data 45.71 45.31 / 45.91
Bounce time: NO/NC ms 3/3 2/—
Vibration resistance (10…150)Hz: NO/NC g 20/10 20/—
Shock resistance g 20
Power lost to the environment without contact current W 0.4
with rated current W 1.8
Recommended distance between relays mounted on PCB mm ≥5
IV-2012, www.findernet.com
2
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com
45 Series - Miniature PCB relays 16 A
Contact specification
F 45 - Electrical life (AC) v contact current F 45 - Electrical life (AC) v contact current
Type 45.71 Type 45.31 / 45.91
Cycles
H 45 - Maximum DC1 breaking capacity
• When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103 cycles (45.71) and
≥ 30·103 cycles (45.31, 45.91) can be expected.
DC breaking current (A)
DC voltage (V)
Coil specifications
DC coil data - 0.36 W sensitive R 45 - DC coil operating range v ambient temperature
Nominal Coil Operating range Resistance Rated coil
voltage code consumption
UN Umin Umax R I at UN
V V V Ω mA
6 7.006 4.2 7.2 100 60
12 7.012 8.4 14.4 400 30
24 7.024 16.8 28.8 1,600 15 limit for 45.31
48 7.048 33.6 57.6 6,400 7.5
60 7.060 42 72 10,000 6
Outline drawings
Type 45.31 Type 45.71 / 91
IV-2012, www.findernet.com
3
Courtesy of Steven Engineering, Inc. - 230 Ryan Way, South San Francisco, CA 94080-5370 - Main Office: (650) 588-9200 - Outside Local Area: (800) 258-9200 - www.stevenengineering.com