Drawings YS1500 Indicating Controller

(YS1500-o0o)
YS1700 Programmable Indicating Controller
(YS1700-o0o, YS1700-o1o)
SD 01B08B01-01E

Unit: mm
<External Dimensions>

69.8
67
56
Note 1
When swung up
Instrument panel thickness: 2.3 to 25 mm
Expandable I/O cable 60
72
60

(YS1700 with Expandable I/O)


Clamp bracket

13

IN
M
0
R6
136.4

162.4
144

132 MIN
13

Clamp bracket Note 2


24.6 250 6
72

Weight: 1.6 kg (Basic type)


2.2 kg (Basic type with Expandable I/O)

Panel Cutout Dimensions Panel Cutout Width for


For single mounting: For side-by-side mounting: Side-by-side Mounting
+0.7
68 0 +1
L0 Number of
instruments L(mm)
to be mounted
2 140
3 212
4 284
+2
137+2

137 0
0

5 356
220 or more

220 or more

6 428
7 500
8 572
9 644
10 716
11 788
12 860
13 932
Trigonometry 14 1004
General tolerance = ±(value of tolerance class IT18 based on JIS B 0401-1998) / 2

Note 1: If a nameplate, etc. is installed within 60 mm above the instrument, the height of the nameplate, etc.
must be 30 mm or less from the panel surface.
Note 2: When installing the expandable I/O cable, secure the wiring space of at least 60 mm for a minimum
curvature radius of the cable in addition to the mountiing bracket space of 72 mm from the terminal
cover face of the main unit.
Note 3: To ensure good air ventilation, allow space of 100 mm or more at the top and bottom of the panel.

All Rights Reserved, Copyright © 2007, Yokogawa Electric Corporation. SD 01B08B01-01E


Subject to change without notice. Printed in Japan. 5th Edition Jun.13, 2014
2

<Terminals Layout>
To the expandable Ethernet Communication
I/O terminals (Optional code /A34)
YS1700-1 only

All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation SD 01B08B01-01E Jun.13, 2014-00
3

<Terminal Arrangement Table>


User settings
Terminal Programmable mode
Single-loop mode Cascade mode Selector mode ( ) mode
number (YS1700 only)
(Note 8)
1 + Analog input 1 + Measurement input + Measurement input 1 + Measurement input 1
2 − (1-5V DC) − (1-5V DC) − (1-5V DC) − (1-5V DC)
3 + Analog input 2 + Cascade setting input + Cascade setting input + Cascade setting input 1
4 − (1-5V DC) − (1-5V DC) − (1-5V DC) − (1-5V DC)
5 + Analog input 3 + Input value for output + Measurement input 2 + Measurement input 2
6 − (1-5V DC) − tracking (1-5V DC) − (1-5V DC) − (1-5V DC)
7 + Analog input 4 + Feedforward input + Feedforward input + Cascade setting input 2
8 − (1-5V DC) − (1-5V DC) − (1-5V DC) (Note 1) − (1-5V DC) (Note 1)
9 + Analog input 5
10 − (1-5V DC)
11 + + + +
FAIL output (Note 2) FAIL output (Note 2) FAIL output (Note 2) FAIL output (Note 2)
12 − − − −
Connection of transmitter Connection of transmitter Connection of transmitter Connection of transmitter
13 supply power (24V DC) supply power (24V DC) supply power (24V DC) supply power (24V DC)
(Note 3) (Note 3) (Note 3) (Note 3)
14 Communication terminal SG Communication terminal SG Communication terminal SG Communication terminal SG
15 Communication terminal SDA (−) Communication terminal SDA (−) Communication terminal SDA (−) Communication terminal SDA (−)
16 Communication terminal SDB (+) Communication terminal SDB (+) Communication terminal SDB (+) Communication terminal SDB (+)
Communication terminal Communication terminal Communication terminal Communication terminal
17
RDA (−) or LCS (+) RDA (−) or LCS (+) RDA (−) or LCS (+) RDA (−) or LCS (+)
Communication terminal Communication terminal Communication terminal Communication terminal
18
RDB (+) or LCS (−) RDB (+) or LCS (−) RDB (+) or LCS (−) RDB (+) or LCS (−)
19
20
21
22 + Analog output 1 + Manipulated output variable 1 + Manipulated output variable 1 + Manipulated output variable 1
23 − (4 to 20mA DC) − (4 to 20mA DC) − (4 to 20mA DC) − (4 to 20mA DC)
24 + Analog output 2 + Manipulated output variable 2 + Manipulated output variable 2 + Manipulated output variable 2
25 − (1-5V DC) − (1-5V DC) (Note 4) − (1-5V DC) (Note 4) − (1-5V DC) (Note 4)
26 + Analog output 3 + + +
Setpoint value output Setpoint value output Setpoint value output
(4 to 20mA DC/1-5V DC)
27 − − (1-5V DC) (Note 4) − (1-5V DC) (Note 4) − (1-5V DC) (Note 4)
(Note 5)
28 + Digital output 1/Digital + High limit alarm setpoint + LOOP 1 alarm output + LOOP 1 alarm output
29 − input 6 (Note 6) − for PV output (Note 7) − (Note 7) − (Note 7)
30 + Digital output 2/Digital + Low limit alarm setpoint + LOOP 2 alarm output + LOOP 2 alarm output
31 − input 5 (Note 6) − for PV output (Note 7) − (Note 7) − (Note 7)
32 + Digital output 3/Digital + Velocity alarm setpoint for + O/C status output + L/R status output
33 − input 4 (Note 6) − PV output (Note 7) − (Note 7) − (Note 7)
34 + Digital output 4/Digital + C/A l M status output + C/A l M status output + C/A l M status output
35 − input 3 (Note 6) − (Note 7) − (Note 7) − (Note 7)
36 + Digital output 5/Digital + C l A/M status output + C l A/M status output + C l A/M status output
37 − input 2 (Note 6) − (Note 7) − (Note 7) − (Note 7)
38 + Digital output 6/Digital + No function (Factory + No function (Factory + No function (Factory
39 − input 1 (Note 6) − default) (Note 7) − default) (Note 7) − default) (Note 7)
L + + + +
Power supply Power supply Power supply Power supply
N − − − −
Grounding terminal Grounding terminal Grounding terminal Grounding terminal
Note 1: These terminals can be used as output tracking input if feedforward input or cascade setting input 2 is not used.
Note 2: Using the terminals as fail output requires an external power supply.
Note 3: For a transmitter power supply, see “Wiring” of “Installation and Wiring” in each YS1000 Operation Guide.
Note 4: For manipulated output variable 2 and setpoint output, the output types can be changed using the analog output-2 selection Y2S and analog output-3 selec-
tion Y3S engineering parameters.
Note 5: For analog output 3, the output type can be changed using the analog output-3 current/voltage switching Y3TP engineering parameter.
Note 6: Using these terminals as digital output requires an external power supply. The function of digital inputs or digital outputs can be set using the YSS1000 Set-
ting Software (sold separately).
Note 7: Using these terminals as digital output requires an external power supply. The settings in the table are the factory defaults. Digital inputs or digital outputs
can be appropriately used by setting the DI/DO setting DIO16 to DIO61 engineering parameters. Functions can be set using the DI1F to DI6F and DO1F to
DO6F engineering parameters.
Note 8: If you change a function using the parameter concerned, enter the setting in the relevant field in the User settings column.

NOTE : Do not use an unused terminal as a relaying terminal, etc.

All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation SD 01B08B01-01E Jun.13, 2014-00
4
l Expandable I/O Terminal (YS010)
Unit: mm
176
167

50
60

29.75
5
4
9 11 M4×L8

.5
33.5

ø4
(When the DIN rail

2-
mounting)

31.2
7
Weight: 260 g

l Expandable I/O Cable (YS011)


Unit: mm

Ground wiring: 1.25mm2, green


R1.25-4 Length:500±50
(70)

(95) 3000±50 (40)

Weight: 320 g

All Rights Reserved. Copyright © 2007, Yokogawa Electric Corporation SD 01B08B01-01E Jun.13, 2014-00