CAC Light Cabinets Ensure Global Standardised Colour Assessment

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Datasheet

Colour Assessment Cabinets


CAC light cabinets ensure global
standardised colour assessment
VeriVide’s Colour Assessment Cabinets are an indispensable tool for
colour assessment, colour quality control and comparisons of colour variation.

CAC60 Cabinet - 600mm The stability of our light sources give excellent viewing conditions for reliable
colour critical decisions under standardised lighting. Ensuring agreement and
consistency through global supply chains, helping to highlight product quality
issues, such as Metamerism, at the earliest opportunity.

Portable cabinet - 600mm

CAC120 Cabinet - 1200mm CAC60 and CAC120

Designed specifically for colour matching and evaluation of any VeriVide’s range of colour assessment cabinets are designed to
material where precise control of colour is critical. match the viewing conditions and spectral qualities of the standard
Backlight LED control panel with various features: illuminats as specified according to the ISO/CIE standards.
servicing indicator, auto sequence, warm-up, power save They also conform to all major international standards for visual
and data storage facility. evaluation, including ASTM, AS, BSI, DIN and ISO.
Options of 4 or 5 light sources including VeriVide’s own specially designed daylight simulator is the only
D50, D65, D75, 840, 830, CWF, F, A and UV. fluorescent light source to give accurate colour reproduction across
Interior Colour options: the entire colour spectrum.
Grey Munsell N5, N7, 5574. The CAC range is available in 3 sizes plus a portable option.

www.verivide.com
Tel: +44 (0)116 284 7790 Email: [email protected]
Datasheet

CAC Range Dimensions (mm)


WIDTH HEIGHT DEPTH
Extenal Dimensions 1560 755 620
CAC150
Viewing Area 1530 545 590

Extenal Dimensions 1290 755 620


CAC120
Viewing Area 1260 545 590
CAC range lamp options
Extenal Dimensions 710 545 420
CAC60 All cabinets are fitted with lamps as standard, which can be configured to
Viewing Area 680 335 380 your own requirements. The range of lamps within the viewing cabinet
Extenal Dimensions 710 545 540 can vary, dependant on the application, from a single light source to a
CAC60 -5 combination of 4 or 5 different light sources.
Viewing Area 680 335 500
A typical combination includes: D65, Artificial Daylight – 840, (formerly
Extenal Dimensions 710 545 540 TL84) a Point of Sale lamp - F, Tungsten Filament (typical home lighting)
Viewing Area 680 335 500 and UV, Ultra Violet Blacklight. Other types of lamps can be included if
requested.
PORTABLE Closed (within carrying
690 340 160 For more detailed information regarding the lamp options please refer to
bag)
our Lamp Options Datasheet or alternatively contact our sales team who
Weight 12 kg
will be happy to assist you.
For the Portable cabinet the fifth illuminant can be chosen from the
following: D75, D50, D65, 830, 840, UV, F.

Lamp useage
Lamps should be replaced after 2000 hours of use. The control panel
includes a service indicator to signify the number of hours usage for each
VeriVide Accessories
individual light source.
Diffusers The standard electrical supply is 220 V / 240 V (50 - 60 Hz). It is important
Diffusers are recommended when assessing highly specular materials that the cabinet is correctly earthed. All other voltage supplies must be
such as paint, glass, polished surfaces and ceramics. These can also be
specified when ordering.
used to create a barrier between light source and viewing area to prevent
contamination - for example of food product. Positioning recommendations
For optimum results minimize the amount of stray ambient light or glare
Dimmable
interfering with your visual assessments. We recommend windows near the
If a variable intensity of light is required or specified, an electronically
Light Cabinet should be covered with a grey curtain. Direct light entering the
controlled Dimmable option is offered.
field of view must be kept to minimum.
Observation tables The lighting environment around the cabinet should have a light level of
Two types of observation table can be supplied; the Tilting Table which 200-300 Lux and the walls near the cabinet should be painted with a
allows variable angles of observation. These are useful for observing surface neutral grey paint comparative with Munsell Grey N7.
coatings, metallic and pearlescent materials and the Fixed Angle Table (image
We would be pleased to offer advice in regards to your own specific location.
above) with the angle of observation fixed at 45º in accordance with ISO105
for the assessment of Colour Fastness.
CAC Range interiors
Benches and planning tables All our CAC range of Light Cabinets are finished as standard, with a neutral
Benches are also available allowing you to position your cabinet at the optimal matt grey interior - ref N5. Alternatively this colour can be changed upon
observation height when used in conjunction with a VeriVide cabinet. Benches request to Munsell Grey N7 or 5574.
with plan drawers can also be supplied. (Further details on our Accessories
Datasheet).

VeriVide is committed to innovation


Scan the QR
in colour assessment and quality code on your
control. From constructing bespoke mobile device
to go directly to
standardised viewing environments our website

to developing new lighting products


Tel: +44 (0)116 284 7790
to meet industry standards, Email: [email protected]
improving your quality and For further technical information
visit: www.verivide.com
VeriVide Limited, Quartz Close, Warrens Business Park,
productivity is always our priority. Enderby, Leicester LE19 4SG UK
Datasheet

Lamp options
Colour requirements for manufacture and retail are complex and
diverse. To ensure product colour, several types of light source are
used (e.g. Artificial Daylight and a Point of Sale Light. Multiple light
sources are also necessary to reveal colour inconsistencies and
metamerism.
For many products, it is critical to ensure components are assessed
under the same illuminants, using defined procedures, in a controlled
viewing environment, by everyone in the supply chain.
This ensures standardised and repeatable colour assessment.

To ensure controlled standardised light, two factors require consideration...


1. COLOUR TEMPERATURE - Kelvin. (K) 2. COLOUR RENDERING INDEX (CRI)
Colour temperature describes the colour appearance A numerical system that measures how well colours
of the light and can vary along with its spectral power are rendered by a lamp in comparison to a reference
distribution. light source.
‘Correlated’ colour temperature applies to fluorescent CRI is measured on an index from 0 - 100, with 100
lamps and approximates the true colour temperature. being an exact match, low values indicate poor colour
Lower colour temperatures appear warmer, such rendering. VeriVide D65 has a CRI rating of 98, this
as Illuminant A and 830. Lamps with a higher colour shows colours more accurately than a CWR with a CRI
temperature look cooler or bluer, like VeriVide D65 and rating of 62.
D75. This rating method is recognised by the Illuminating
Engineering Society (IES) and the Commission
International de L’Eclairage (CIE).

RETAILER SPECIFICATIONS
Some large retailers have differing specifications for the lamps
and paint used in the Colour Assessment Cabinets, for more
details please go to ‘Retailer Specifications’ at verivide.com
Lamp specifications overleaf

www.verivide.com
Tel: +44 (0)116 284 7790 Email: [email protected]
VeriVide lamp specifications
CIE DAYLIGHT ILLUMINANTS
LIGHT PRODUCT
NAME DESCRIPTION C.R.I. LENGTH WATTS DIAM
SOURCE CODE
D75 VeriVide D75 Correlated colour temperature 7500K. Conforms to USA ASTM 96 600mm 20w T12 600D75
“Artificial D1729-82 standard for D75
Daylight” Illuminant. High CIE specifications for accurate colour matching.
D65 VeriVide D65 VeriVide D65 ‘Artificial Daylight’. Correlated colour temperature 6500K. 98 600mm 18w T8 600D65
“Artificial Within tolerances prescribed in BS 950: Part 1; and all international 1200mm 36w T8 1200D65
Daylight” specifications for D65 illuminant. Specified for most applications where colour 1500mm 58w T8 1500D65
consistency and quality are required. High conformance to ISO 23603 - CIE S 012/E
specifications for accurate colour matching.
D50 Osram Color 98 600mm 18w T8 60095
Proof D50 Correlated colour temperature of 5000K. For graphic and photographic applications. 1200mm 36w T8 120095
“Artificial D50 lamps conform to ISO 3664. Recommended for viewing transparencies and for 1500mm 58w T8 150095
Daylight” reflected light source to view reproductions.

CIE ILLUMINANT ‘A’


LIGHT PRODUCT
NAME DESCRIPTION C.R.I. LENGTH WATTS DIAM
SOURCE CODE
‘F’ Tungsten 100 Globe 40w 45mm 40G450
Tungsten Filament Lighting. Approximate colour temperature of 2800K. Required by
Filament Globe 60w 45mm 60G450
BS 950: Part 1 as a test for metamerism (approximating CIE Illuminant ‘A’). Typical
Clear-284mm 60w - 28460CL
light source used within domestic environments.
Opal-284mm 60w - 28460OP
‘A’ Tungsten Tungsten Halogen Lighting (CIE Illuminant ‘A’). This represents incandescent A (inc-A) 100 - 35w - HALO/12V
Halogen with a colour temperature of 2856K. Typical light source used within domestic /35WLP
environments. Used to check for metamerism.

ALTERNATIVE (FLUORESCENT) LIGHTING / POINT OF SALE


LIGHT PRODUCT
NAME DESCRIPTION C.R.I. LENGTH WATTS DIAM
SOURCE CODE
840 P15 VeriVide Narrow Band Triphosphor Fluorescent Lamps. Correlated colour 85 600mm 18w T8 60084P15
840 P15 temperature of 4000K. CIE Illuminant F11. Often chosen as a European 1200mm 36w T8 120084P15
Point of Sale light source. Good colour rendering, manufactured 1500mm 58w T8 150084P15
to a tighter tolerance, specified by Marks & Spencer. (Formerly TL84P15)
CWF Cool White Cool White Broad Band Fluorescent Lamps. Correlated colour temperature 62 600mm 20w T12 60033
of 4000K. Used as an American “Point of Sale” light source. Moderate colour 1200mm 40w T12 120033
rendering. 1500mm 65/80w T12 150033
U35 Ultralume Ultralume Narrow Band Triphosphor Fluorescent Lamp. Correlated colour 85 600mm 17w T8 600U35
35 temperature 3500K. An American “Point of Sale” light source, with good colour 1200mm 32w T8 1200U35
rendering.
830 Narrow Band Triphosphor Fluorescent Lamp. Correlated colour temperature 85 600mm 18w T8 60083
3000K. Often chosen as a European “Point of Sale” light source with good colour 1200mm 36w T8 120083
rendering.(Formerly TL83) 1500mm 58w T8 150083

HORIZON
LIGHT PRODUCT
NAME DESCRIPTION C.R.I. LENGTH WATTS DIAM
SOURCE CODE
‘H’ Tungsten 98 - 75w - HALO/12V
Halogen Colour temperature 2300K. Used for automotive, apparel and metamerism Testing. /75W
As specified by the ASTM (American Society for testing and Materials) D1729-74,
Standard Practise for Visual Evaluation of Colour Differences of Opaque Materials

ULTRAVIOLET
LIGHT PRODUCT
NAME DESCRIPTION C.R.I. LENGTH WATTS DIAM
SOURCE CODE
UV Ultraviolet Ultraviolet Blacklight. Used to detect the presence of Optical Brightening Agents and/ N/A Clear450mm 15w T8 450UV15
or Fluorescent dyes. Therefore it is useful when assessing white and Fluorescent Blacklight 600mm 18w T8 600UV18
shades to check the level present and its evenness.

If you need further information regarding our range of replacement lamps for our cabinets please contact us.

VeriVide is committed to innovation


Scan the QR
in colour assessment and quality code on your
control. From constructing bespoke mobile device
to go directly to
standardised viewing environments our website

to developing new lighting products


Tel: +44 (0)116 284 7790
to meet industry standards, Email: [email protected]
improving your quality and For further technical information
visit: www.verivide.com
VeriVide Limited, Quartz Close, Warrens Business Park,
productivity is always our priority. Enderby, Leicester LE19 4SG UK
Datasheet

Accessories
Accessories are available for our range of Light Cabinets to maximise your comfort and to optimise the viewing
environment. Included are viewing tables to ensure your product is viewed at the correct angle and benches and drawer
units at the correct specied height standard.
If you have precise requirements for a bench or working area we are able to make bespoke product to meet your needs.
Please contact us with your requirements.

PLAN CHEST WITH DRAWERS CODES: PC120, PC150


Plan chests with drawers are available in two DIMENSIONS (MM) WIDTH HEIGHT DEPTH
widths, both have five drawers suitable for Plan Chest 150 1600 925 645
storing proofs and approved standards to A1 Plan Chest 120 1330 925 645
size. The wider 150 cm plan chest (image far
right) also has a side cupboard.

BENCHES CODES: B60-1, B120-1, B150-1

Our benches are steel with a cantilever design DIMENSIONS (MM) WIDTH HEIGHT DEPTH
to enable easy access to the single storage Bench 150 1570 925 610
shelf. The benches are at the height for
Bench 120 1295 925 610
optimum viewing when used with a VeriVide
Bench 90 910 925 610
Light Cabinet.
Bench 60 720 925 610

TILTING TABLE CODE: TT

The Tilting Table is for use with our CAC DIMENSIONS (MM) WIDTH HEIGHT DEPTH
range of Light Cabinets. It is designed to offer
External Dimensions 640 235 310
multiple viewing angles for the assessment
Viewing Area 610 305 -
of colour, e.g. surface coatings, metallic and
Footprint 640 - 215
pearlescent materials and foil manufacture.

FIXED ANGLED TABLE CODE: FAT

The 45° Fixed Angle Table is for use with


DIMENSIONS (MM) WIDTH HEIGHT DEPTH
our CAC range of Light Cabinets. It offers
External Dimensions 610 235 255
standardised viewing geometry at a 45°
Viewing Area 610 305 -
angle where the light strikes the table
Footprint 610 - 200
surface. Ideal for colourfastness assessment
as specified in British Standard ISO 105.

www.verivide.com
Tel: +44 (0)116 284 7790 Email: [email protected]
Datasheet

Servicing
Our Light Cabinets are precision engineered to an extremely high Servicing includes:
standard. A regular maintenance schedule is essential to ensure
Initial inspection and testing.
optimum performance.
Removal and disposal of all lamps. (WEEE compliant).
One of the biggest influences on the perceived colour is the light
source. As lamps age there is a potential shift in the spectral Clean and polish the white reflector.
power distribution of the light source. Maintaining a reliable output Fit and test new lamps to specification. *
of the light source is critical to consistent colour evaluation. Rub down and clean interior surface of cabinet.
The influence of the reflector and interior surfaces within the Repaint interior surface to specification.
lighting cabinet is often underestimated. The absorption and
Clean exterior of the cabinet.
refection of the light sources has a significant influence on the
overall performance of the cabinet and therefore needs to be Reset switch panels and record data.
maintained. Final inspection and test to VeriVide’s quality standards.
Deterioration of reflected light or a decline in the quality of the Supply of Service Certificate.
spectral output will make your colour critical decisions unreliable Lamp Calibration (if requested).*
and inconsistent.
This creates potential for incorrectly rejected or approved
products, costly claims and confusion within the supply chain, WEEE Directive 2006
causing delays in time to market. The disposal of lamps is in compliance with WEEE regulations
Additionally, a Light Cabinet without a regular maintenance (Waste Electrical and Electronic Equipment Regulations 2006).
schedule is not compatible with a successful accreditation. UK only.
We are a member of Recolight - the only specialist WEEE lamp
When should you service your cabinet? compliance scheme in the UK.
If it has been a year or more since your last service. * The cost of the replacement lamps is an additional charge, as is Lamp Calibration

If you have purchased your cabinet over a year ago and never
had it serviced. Maintenance Pack
If your lamps reach the optimum life-time of 2,000 hours use For use in conjunction with replacement lamps, our maintenance
BEFORE the annual service. pack enables the white reflector to be cleaned and polished and
the grey interior walls to be prepared prior to a fresh application of
Trained service engineers the specified paint.
Our international network of Sales Agents and Trained Service All items you need in one handy disposable pack:
Engineers are able to provide scheduled, routine maintenance Cleaning Cloth 4” Sandpaper Square
to ensure your VeriVide equipment remains optimized and to
Cleaning Wipe Gloves
standard.
Paint Brush Sponge Foam Roller
Apron Tin of Paint
Paint Tray (5574, N5 or N7)

To book your light cabinet’s service:


Call: +44 (0)116 284 7790 or email [email protected]

VeriVide is committed to innovation


Scan the QR
in colour assessment and quality code on your
control. From constructing bespoke mobile device
to go directly to
standardised viewing environments our website

to developing new lighting products


Tel: +44 (0)116 284 7790
to meet industry standards, Email: [email protected]
improving your quality and For further technical information
visit: www.verivide.com
VeriVide Limited, Quartz Close, Warrens Business Park,
productivity is always our priority. Enderby, Leicester LE19 4SG UK
Specification data

New Fixed Angle Table


Magnetic attraction Fastness grading has played a critical role in textile testing for over 50
years. Users of conventional grading equipment often struggle to hold
Leaves your hands free the sample and grading mask while simultaneously trying to adjust

to adjust the greyscale


the greyscale. This can sometimes lead to less accurate judgements.
The VeriVide solution is simple but remarkably effective. Our
magnetic grading mask holds the sample in place and masks off the
assessment area. This leaves hands completely free to adjust the
greyscale.
The new Fixed Angle Table has now been added to the VeriVide
product range and is available for immediate delivery.
See over for full product details

“The magnetic grading


mask improves
concentration and helps
produce more accurate
judgements, because the
grader no longer has to
do three things at once.”
Retail Laboratory Manager

www.verivide.com
Tel: +44 (0)116 284 7790 Email: [email protected]
Specification datasheet

New Fixed Angle Table


The new Fixed Angle Table maintains the fixed 45° angle required
by a wide range of national and international standards, including:
AATCC Evaluation procedures 1, 2 + 9 (Table Only)
BS EN and ISO – Textiles - Tests for Colour Fastness
(105-AO2 105-AO3)
ISO 3668 Paints and Varnishes:
Visual Comparison of the Colour of Paints
ASTM D1729 : Artificial Daylight for the Assessment of Colour:
Part 1 Illuminant for colour matching and colour appraisal
UK Retailer Testing Standards including:
M&S - Colour Fastness Test Methods
Next - Test Methods for Colour Fastness and Durability
Dimensions
It is lighter, easier to move and more durable than previous
models, and its steel construction allows magnets to be used. Overall: 235mm tall x 210mm deep x 610mm wide
Each Fixed Angle Table comes with four matt black magnets - two
Viewing platform: 610mm wide x 275mm tall
high strength, two low strength - to hold samples in place across
the viewing surface.
The magnetic grading mask has two aperture sizes (matching
Features and benefits
those of existing non-magnetic masks) and the raised tabs at
each end of the mask allow for easy lifting.
Metal More durable, allows for the use of magnets
Rubber feet ensure that the interior of the light cabinet is not
damaged when positioning the table. 2 sizes/strengths Ability to hold samples in position without
of magnet using hands
The VeriVide Fixed Angle Table is available in paint colours
N5, N7 or 5574. Paint application is controlled to extremely Magnetic grading Functions as a fastness grading mask while
strict tolerances. mask holding the sample in place. Hands are
completely free to adjust the fastness grey
Cabinet
scale.
Observer

Paint finish: Painted to comply with specific standards


choice of
N5, N7 or 5574

Incident
Light Reflected Light weight Easy to manoeuvre
Light

Fixed shelf Samples mounted on card are held in place

45º Specular Rubber feet Prevent damage to the cabinet interior when
Light
sliding across the base.

VeriVide is committed to innovation


Scan the QR
in colour assessment and quality code on your
control. From constructing bespoke mobile device
to go directly to
standardised viewing environments our website

to developing new lighting products


Tel: +44 (0)116 284 7790
to meet industry standards, Email: [email protected]
improving your quality and For further technical information
visit: www.verivide.com
VeriVide Limited, Quartz Close, Warrens Business Park,
productivity is always our priority. Enderby, Leicester LE19 4SG UK

You might also like