0% found this document useful (0 votes)
29 views

Sleeve Springs: Diesel Customer Information No. 291

The document discusses the service life of sleeve springs in vibration dampers for MAN Diesel four-stroke engines. Calculations show the theoretical durability of the sleeve springs is approximately 80,000 operating hours under normal conditions. The document recommends inspecting and replacing the sleeve springs no later than 80,000 hours to ensure safe and reliable engine operation. Technical support is available from MAN Diesel for inspection and replacement work.

Uploaded by

mariodal
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views

Sleeve Springs: Diesel Customer Information No. 291

The document discusses the service life of sleeve springs in vibration dampers for MAN Diesel four-stroke engines. Calculations show the theoretical durability of the sleeve springs is approximately 80,000 operating hours under normal conditions. The document recommends inspecting and replacing the sleeve springs no later than 80,000 hours to ensure safe and reliable engine operation. Technical support is available from MAN Diesel for inspection and replacement work.

Uploaded by

mariodal
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Diesel Customer Information No.

291

Action Code:
When Convenient

General Remarks Sleeve Springs


Our medium-speed engine types 32/40, 40/54, 48/60, Vibration damper: Operating
58/64 are successfully used in ships and power plants time of sleeve springs
worldwide.
DCI / 291 - March 2010
There are engines which have already been in service
for more than 25 years. Many of these engines have Concerns
already reached more than 90,000 operating hours. MAN Diesel four-stroke engines 32/40,
40/54, 48/60, 58/64
During their operation, diesel engines are subjected to a
certain stresses which inevitably lead to aging and Summary
wear. This also applies to the sleeve springs of the Subject to normal operating conditions,
vibration dampers on camshaft and crankshaft. sleeve spings reach a service life of approx.
80,000 operating hours.

Measure Filing Advice


Assembly group/working card 027
Calculations and examinations have shown that the
theoretical durability of the sleeve springs is reached at
a component operating life of approx. 80,000 hours,
when a corresponding safety factor is taken into
consideration.

As a basis of this consideration, permanent engine


operation at 100% engine load without circumstances
having a negative impact was assumed.

Unfavourable operating conditions such as improper


maintenance, hydraulic shocks or the like reduce the
theoretical service life.

MAN Diesel SE PrimeServ PrimeServ PrimeServ


Head office (& postal address) After Sales Augsburg After Sales Technical After Sales Commercial
Stadtbachstraße 1 Stadtbachstraße 1 Stadtbachstraße 1 Stadtbachstraße 1
86153 Augsburg 86153 Augsburg 86153 Augsburg 86153 Augsburg
Germany Germany Germany Germany
Phone: +49 (0) 821 322 0 Phone: +49 (0) 821 322 3509 Phone: +49 (0) 821 322 1499 Phone: +49 (0) 821 322 1799
Fax: +49 (0) 821 322 3382 Fax: +49 (0) 821 322 1530 (24-h-hotline) (24-h-hotline)
[email protected] [email protected] Fax: +49 (0) 821 322 3838 Fax: +49 (0) 821 322 3574
www.mandiesel.com [email protected] [email protected]

MAN Diesel – a member of the MAN Group


DCI / 291 - March 2010

Recommendation
In order not to jeopardize the safe and reliable operation of the engines, we recommend inspecting the sleeve
springs of the camshaft and crankshaft vibration dampers within the scope of the general maintenance
intervals, replacing them if necessary no later than approx. 80,000 operating hours.

Additional Information
Should you be interested in this work being performing by MAN Diesel SE specialists, please contact our
Technical Service in Augsburg or one of our worldwide Service Centers.

Contact
Should you have any queries, our Technical Service will be pleased to be of assistance:

MAN Diesel SE
86224 Augsburg
Tel.: +49 (0) 821 322-1349
Fax: +49 (0) 821 322-3838
E-mail: [email protected]

Robert Glauber Jörn Holst


Senior Vice President Senior Manager
After Sales After Sales Technical

Please forward this information to your technical operational personnel and


remember to inform us of the current operating hours of your MAN Diesel engines.

Diesel Customer Information »Sleeve Springs« - Page 2 of 2

You might also like