Saudi Aramco Inspection Checklist: Buttering and / or Weld Build-Up - Offshore Structures SAIC-W-1311 Weld

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

SAUDI ARAMCO ID/PID - 29/09/2017 - REV 0 (Standards Cutoff - January 2017 ) REV 0 29-Sep-17

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Buttering and / or Weld Build-up - Offshore Structures SAIC-W-1311 WELD


PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A General:

WPS's used for repair /build-up/buttering was approved by SaudiAramco SAES-W-013


A1
and displayed at site Para 7.1.7

All welders, welding operators, brazers, and brazing operators shall be


qualified in accordance with AWS D1.1 and SAEP-1150, SAEP-321, SAES-W-013
A2
SAEP-322, SAEP-323, and SAEP-324, as applicable, for all structural Para 8.1
welding, including tack, temporary, and repair welds.

Welder(s) have been issued Qualification card, and that range of


A3 SAEP-324
qualification shown matches the application of WPS being used.

The Buttering operation shall be witenessed by Saudi Aramco Inspection


when buttering or weld build-up exceed the lesser 1/3 of the basemetal
SAES W-013
thickness or 10mm.The buttering shall be inspected by PT or MT after
A4 Para 10.3.4.2
completion of the build-up but before final welding of the joint.
Para 10.3.4.3
Note :Buttering shall not be used on a routine basis for correction of
dimensional tolerances.

Buttering or weld build-up on the prepared surfaces shall not exceed the SAES W-013
A5
lesser of 19mm or two times the base metal thickness whichever is less. Para 10.3.4.1

Oil, moisture, scale, rust, paint (except an approved weld able


primer),metallic coatings (e.g. zinc) or other foreign matter, has been SAES W-013 Para Para
A6
removed from the weld surface and at least 25mm of the adjacent base 10.3.1
metal surface, prior to welding

REMARKS:

REFERENCE DOCUMENTS:
1. SAES-W-013, Welding Requirements for Offshore Structures(January 22 2015)
2. SAEP-324, Certification Review and Registration of Project Welders and Brazers,(October 12 2015)

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED