Professional Practice and Ethics: Planning Parameters For Non High Rise Buildings

The document outlines planning parameters for non-high rise buildings not exceeding 18.3 meters in height. It details maximum road widths, heights, floor space indexes (FSI), minimum setbacks, parking requirements, and other development rules. Key points include: - Maximum building height of 12 meters for up to 8 dwellings and 18.3 meters otherwise - Maximum FSI of 2 for all areas - Minimum front setbacks of 1.5-6 meters depending on road width - Minimum side and rear setbacks of 1-3 meters depending on building height - Parking requirements of 1-2 spaces per dwelling depending on floor area - Mandatory rainwater harvesting and solar panels for buildings over 16

Uploaded by

ritika
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views11 pages

Professional Practice and Ethics: Planning Parameters For Non High Rise Buildings

The document outlines planning parameters for non-high rise buildings not exceeding 18.3 meters in height. It details maximum road widths, heights, floor space indexes (FSI), minimum setbacks, parking requirements, and other development rules. Key points include: - Maximum building height of 12 meters for up to 8 dwellings and 18.3 meters otherwise - Maximum FSI of 2 for all areas - Minimum front setbacks of 1.5-6 meters depending on road width - Minimum side and rear setbacks of 1-3 meters depending on building height - Parking requirements of 1-2 spaces per dwelling depending on floor area - Mandatory rainwater harvesting and solar panels for buildings over 16

Uploaded by

ritika
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

PROFESSIONAL PRACTICE AND ETHICS

PLANNING PARAMETERS FOR NON HIGH RISE BUILDINGS

RITIKA.G.R
3621059
PARAMETERS FOR NON HIGH RISE BUILDINGS.
1.All Buildings not exceeding 18.30m in height.
a.The minimum road width, FSI, set back etc. for Non High Rise buildings up to16 dwellings or up to 300
square meters of commercial building shall be regulated according to the information given below:

MAXIMUM ROAD WIDTH.


For continuous building areas -3m.
For economically weaker section areas-3m.
For other areas-3m to 6m.

MAXIMUM HEIGHT. up to 8 dwellings


For continuous building areas - GF + 2F or Stilt + 3F subject to a maximum of 12m height.
For economically weaker section areas- GF + 2F or Stilt + 3F subject to a maximum of 12m height
For other areas(3m to 6m)- GF + 2F or Stilt + 3F subject to a maximum of 12m height.
For other areas(above 6m)- GF + 2F or Stilt+ 3F subject to a maximum of 12m height.

MAXIMUM NUMBEROF DWELLING UNITS /COMMERCIAL USE


For continuous building areas - up to 16 dwellings or up to 300 square meters of commercial use.
For economically weaker section areas- up to 16 dwellings.
For other areas(3m to 6m)- up to 8 dwellings.
For other areas(above 6m)- up to 16 dwellings or up to 300 square meters of commercial use.
MAXIMUM FSI
For continuous building areas -2m.
For economically weaker section areas-2m.
For other areas-2m.
MINIMUM SET BACKS
FRONT SET BACK SIDE SET BACK
For continuous building areas -1.5. For continuous building areas -NIL.
For economically weaker section areas-1.0m For economically weaker section areas-NIL
For other areas For other areas
More
Abutting road Width Front set back thanHeight
7m. of the building Plot width SSB
upto
Upto 9.0m. 1.5m 12m.
Upto 7m. Up to 9m 1m on one side

More than 9.0m. Above 9m 1m on


upto 18m. 3.0m. either side
Up to 6m 1m on one side
More than 18m. More than 7m.
upto 30.5m 4.5m. upto12m. Above 6m, 1.5m on
upto 9m one side
More than 30.5m. 6.0m. Above 9m 1.5m on
either side
REAR SET BACK
For continuous building areas -NIL.
For economically weaker section areas-NIL
For other areas
Height of the building RSB
Upto 7m. Nil
More than 7m upto 12m. 1.5m

b.The minimum road width, FSI, set back etc. for Non High Rise buildings upto18.30m height and exceeding
16 dwelling units and exceeding 300 square meters of commercial building shall be regulated according to
the information below.

MINIMUM ROAD WIDTH


For continuous buildings and other areas-9.0m
MAXIMUM HEIGHT
For continuous buildings and other areas-18.30m.
MAXIMUM FSI
For continuous buildings and other areas-2m.
MINIMUM SET BACKS
Where Street Alignment/new road is prescribed, it shall be from that street alignment/ new road line. In the
case of others, it shall be from the property boundary.

SIDE SET BACK /REAR SET BACK FRONT SETBACK


For continuous buildings areas -NIL.
For continuous buildings areas and
For other areas Other areas.
Height of the building SSB / RSB
Upto 7m. 1.0m. Abutting road width FSB
More than 7m. From 9.0m. upto 18m. 3.0m.
upto 12m. 1.5m.
More than 18m. upto 30.5m 4.5m.
More than 12m.
upto 16.0m. 2.5m. More than 30.5m. 6.0m.

More than 16m.


upto 18.30m. 3.0m.
c.PASSAGE
(i).Non High Rise buildings upto 12m height
If the site does not directly abut a public road but gains access through a private passage or through a part of
the plot which can be treated as a passage from a public road of minimum width as prescribed above, the
minimum width of such passage shall be as follows:
When it is intended to 8 dwellings,the passage width can be a) CBA / EWS areas – 1 m
b) Other areas – 3 m
(ii).Non High Rise buildings exceeding 12.0m in height upto 18.30m height or exceeding 16 dwelling units

If the site does not directly abut a public road but gains access through a private exclusive passage or through
a part of the plot which can be treated as a passage from a public road of minimum width as prescribed above,
the minimum width of such passage shall be as follows:

(i) When it is intended to 8 dwellings or up to 600square metres of commercial building and the
length of the passage does not exceed 80 metres - 3.6 meters
(ii) When it is intended to serve upto 12 dwellings or upto 2,400 square metres of commercial building
and the length of the passage does not exceed 100 metres-4.8 meters
(iii) When it is intended to serve not more than 16 dwellings or up to 3000 square metres of
commercial building and the length of passage does not exceed 120 metres-6 meters
(iv) When it is intended to serve not more than 20dwellings or up to 6000 square metres of
commercial building and the length of passagedoes not exceed 120 metres-7.2 meters
(v) When it is intended to serve more than 20dwellings or more than 6000 square metres of
commercial building-9 meters
2.Structures permissible in the minimum prescribed set back spaces are given in rule 28.
3.The minimum width of corridor shall be as given in rule 42.
4.Parking spaces shall be provided within the site conforming to standards prescribed in the Annexure - IV.
5.Rainwater harvesting provisions as prescribed in the Annexure - XXII.
6.Special regulations for physically disabled provided in the rule 43 shall be adhered to.
7.Solar energy capture provisions as prescribed in the regulations given in rule 44 shall be provided where
applicable.
8.The reservation of land for community recreational purposes such as park or playground required in
these regulations shall be as given in the rule 41.
9.Internal vehicular access way including passage if any within the site shall a clear width of 7.2 m and such
vehicular access shall be available for every building block in the site within a distance of 50 metres. Further,
it shall be a clear open to sky and no projection of structure over it is permissible.
10.If the building is constructed on stilts and the stilt floor is to be used for parking, it shall not be enclosed,
if it is enclosed it shall be counted for FSI.
11.Every Non High Rise building development exceeding 900 sq.m in floor area shall be provided with
electrical room in ground floor or open space at ground level with in the premises to accommodate
electrical transformer conforming to rule 46.
12.If a Non High Rise building contains more than one use and the allowability of the built space with
reference to the abutting road width and exclusive passage width shall be decided based on the number of
dwellings for the residential use and quivalent floor area allowable for commercial and other uses.
13.Any construction with roof over it in the terrace floor for A.C. Plant or structures shall be counted, as
a floor and categorization of type of building shall be done accordingly.
PARKING REQUIREMENTS
Corporation of municipal areas Panchayat areas

Dwelling unit number of parking spaces Dwelling unit number of parking spaces

Floor area upto Floor area upto


25 sq m NIL 25 sq m NIL

Floor area above Floor area above


25 sq m upto 50sq m 1 two wheeler space 25 sq m upto 50sq m 1 two wheeler space

Floor area above 1 car space for every 2 Floor area above 1 car space for every 2
50 sq m upto dwelling units and 1 two 50 sq m upto dwelling units and 1 two
75 sq m wheeler space for every 75 sq m wheeler space for every
dwelling unit dwelling unit

Floor area above 1 car space for every Floor area above 1 car space for every
75 sq m 75 sq m 100 sq m 100 sq m
Erection of solar photo voltaic panels.-

Installation of Solar Energy System is mandatory in all buildings in the category of High Rise Buildings and Non
High Rise Buildings exceeding 16 dwelling units and 300 sq.m of commercial building, Accordingly
(a) Minimum terrace area to be reserved for erecting solar photo voltaic panels shall be 1/3rd of total terrae
area.
(b) The space required for erecting solar photo voltaic panels is about 10sq.m. for generating 1 KW of
electricity.
(c) The electricity generated from solar photo voltaic system so erected will be used for common electricity
requirements like staircase lights, setback lights, lifts, pumps and non-floor space index areas, etc.
Rain Water Harvesting
Non High Rise Buildings – Buildings of height up to 12m

In plots to be developed/buildings where the setback


area is very small, not enough to dig a recharge well or
sewers, water line, electrical cable running
below, rooftop water brought down by pipes should be
led to percolation pits, one per pipe.
In plots to be developed/buildings without an open
well, rooftop water to be diverted to a sump for
immediate use (if that is relevant), through a first flush
cum pebble-sand filter combination or a Special filter
and the overflow to bediverted to a recharge well. The
rain falling on the driveway or paved setback
areas and from rooftop pipes that are not connected to
the sump or rechargewell to be intercepted near the
gate(s) either by means of a gutter (provided
with a perforated lid) or a bump/speed breaker
arrangement and led to a
recharge well

In plots that are being developed/buildings with a dug


(source) well, rooftop water to be diverted to a sump for
immediate use (if that is relevant), through a first flush
cum pebble-sand filter combination or a Special filter and
the overflow to be diverted to the source well. The rain
falling on the driveway or paved setback areas (around
campus) and from rooftop pipes that are not connected to
the sump or source well to be intercepted near the gate(s)
either by means of a gutter (provided with a perforated
lid) or a bump/speed breaker arrangement and led to a
recharge well.
Structural Safety.

In the cases of Non High Rise buildings with height upto 12m.,
industrial or institutional buildings upto G+1 floors in height and with floor area both
existing and proposed not exceeding 300 sq.m. the provisions in this part of the rules
relating to structural design, submission of working drawings or structural drawings,
etc. shall not apply except that all such applications and plans for these developments
shall be signed by the owner or Registered Developer, and the Registered Engineer or
Architect who prepared the plan and further the Registered Engineer or Architect shall
certify that the structural design of the small development has been done as per the
latest Indian standard Specifications and the National Building Code.

Constructional Safety

All construction except Non High Rise buildings with height upto 12m. shall be carried out under
supervision of the Registered Construction Engineer on Record (CER)