Current Draw and Thermal Dissipation

FP+ Series: Dedicated Touring Amplifiers

FP 7000
A channel
R

-10dB
channel A
SIG -20 -15 -10 -4 VPL CPL VHF
PWR
HI-IMP CLIP TEM
-inf 0 MUTE
POW
BRIDGE A+B PAL FP SERIES
B channel -10dB
channel B
SIG -20 -15 -10 -4 VPL CPL VHF
NOMAD
HI-IMP CLIP TEM LINK
-inf 0 MUTE
POW
FP7000

The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).

FP 7000
Rated Line Current *2) Watt *1) Thermal Dissipation
Level Load
Power 115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr

Standby w. remote Power Off via NomadLink 0 0 0 0 0


Power On, Idling 92 0 92 316 80
Amp W
Pink noise 16 ! / Ch. 730 x2
6,8 3,4 411 183 229 781 197
(1/8 rated 32 ! / Bridged 1460 x1
power) 8 ! / Ch. 1450 x2
10,8 5,4 692 363 329 1123 283
16 ! / Bridged 2900 x1
4 ! / Ch. 2800 x2
17,4 8,7 1176 700 476 1625 409
8 ! / Bridged 5600 x1
2 ! / Ch. 3500 x2
22,0 11,0 1518 875 643 2195 553
4 ! / Bridged 7000 x1
Pink noise 16 ! / Ch. 730 x2
19,6 9,8 800 487 313 1070 270
(1/4 rated 32 ! / Bridged 1460 x1
power) *3) 8 ! / Ch. 1450 x2
33,3 16,6 1455 967 489 1667 420
16 ! / Bridged 2900 x1
4 ! / Ch. 2800 x2
39,4 19,7 2705 1867 838 2860 721
8 ! / Bridged 5600 x1
2 ! / Ch. 3500 x2
39,4 19,7 3088 2333 754 2574 649
4 ! / Bridged 7000 x1
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Nema L5-30P Twist lock

*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified here
is what is known as the "Active Power" of the amplifier providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.

*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power. Note
that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
in excess of max. ratings.