Secondary Suites: Building Permit Application Guide
Secondary Suites: Building Permit Application Guide
Construction Drawings
All drawings must be submitted in Digital Submission Guidelines,
drawn to an appropriate scale (min or metric equivalent), and clearly legible. Drawings in pencil shall
be photocopied prior to submission, with the density adjusted so that all information is clear and legible. All
walls must be drawn as double lines (accurately showing wall thickness), and drawings must clearly
differentiate between existing and proposed construction. Every page of the drawings shall include the project
address and the following designer information:
Homeowner design - printed name of homeowner, signature and date
Qualified BCIN design - printed name, individual/firm (if applicable) BCIN numbers, signature and date
Architect or Professionally - Architect or Professional Engineer s seal with a signature and date
Engineered design
1) Site Plan
3) Proposed Floor Layouts including Egress Plan (Samples A-01, A-02, A-03, A-04)
4) Elevations showing Secondary Suite Entrance and Egress/Escape Window (Samples A-05)
Refer to the enclosed sample drawings for specific drawing requirements, including the number of copies of
each drawing required. In addition, when exterior window or door openings are added/enlarged or the
Secondary Suite does not have a door on the floor level with direct access to the exterior please refer to the
Exterior Openings Building Permit Application Guide requirements, including
specific egress window requirements.
Inspection Requirements:
Typical Secondary Suite inspections can include (depending on the scope of work):
Framing
Insulation & Air Barrier
Underground Plumbing, Above Ground Plumbing and Final Plumbing
Heating Rough-in and Final Heating
Final Building
Inspections are booked by calling the Building Division at (905) 878-7252 ext. 2396 or online by using our
Online Building Inspection Request form.
Milton Town Hall | 150 Mary Street, Milton ON L9T 6Z5 | P. (905) 878-7252 | F. (905) 878-6995 | TTY. (905) 878-1657
The Town of Milton is committed to providing accessible formats and communication supports for persons with disabilities. If another format would work
better for you, please contact 905-878-7252 ext. 2109 or visit http://www.milton.ca/en/live/accessiblemilton.asp | TTY at 1-866-786-3941.
www.milton.ca
SECONDARY SUITES
BUILDING PERMIT APPLICATION GUIDE
Revised: February 2020 Page 3 of 5
Milton Town Hall | 150 Mary Street, Milton ON L9T 6Z5 | P. (905) 878-7252 | F. (905) 878-6995 | TTY. (905) 878-1657
The Town of Milton is committed to providing accessible formats and communication supports for persons with disabilities. If another format would work
better for you, please contact 905-878-7252 ext. 2109 or visit http://www.milton.ca/en/live/accessiblemilton.asp | TTY at 1-866-786-3941.
www.milton.ca
SECONDARY SUITES
BUILDING PERMIT APPLICATION GUIDE
Revised: February 2020 Page 4 of 5
ROOM SIZES - Separate Spaces Min. ft2 ROOM SIZES - Combined Min. ft2
Living Room 145 Living Room (> 1 bedroom) 145
Dining Room 75 Living Room (1 bedroom) 118
Kitchen (> 1 bedroom) 45 Dining Room 35
Kitchen (1 Bedroom only) 40 Kitchen (> 1 bedroom) 45
Master Bedroom (with closet) 95 Kitchen (1 bedroom) 40
Master Bedroom (without closet) 105 Bedrooms 45
Other Bedroom (with closet) 65
Other Bedroom (without closet) 75 ROOM SIZES - Bachelor Min.ft2
Sufficient space for Living, Dining, Bedroom
Bathroom 145
fixtures and Kitchen
Each unit shall have access to common laundry facilities or have connections within each unit for the
connection of laundry appliances
Note: These design tips do not cover all of the requirements for Secondary Suites. The person taking responsibility for the
design should refer to the 2012 Ontario Building Code for a detailed listing of all requirements. The most current Building
Code is available at e-Laws - Ontario Building Code
Milton Town Hall | 150 Mary Street, Milton ON L9T 6Z5 | P. (905) 878-7252 | F. (905) 878-6995 | TTY. (905) 878-1657
The Town of Milton is committed to providing accessible formats and communication supports for persons with disabilities. If another format would work
better for you, please contact 905-878-7252 ext. 2109 or visit http://www.milton.ca/en/live/accessiblemilton.asp | TTY at 1-866-786-3941.
www.milton.ca
SECONDARY SUITES
BUILDING PERMIT APPLICATION GUIDE
Revised: February 2020 Page 5 of 5
System Components:
Piping materials include: copper (Type L) & cross-linked polyethylene pipe fittings (PEX) certified to
CAN/CSA-B137.5
Listed residential sprinklers shall be used (manufacturer spec. sheets must be retained on-site)
Design Requirements:
Only residential full flow through installations are permitted
An adequate water supply shall be confirmed f service)
No isolation valves permitted on any portion of the sprinkler service line upstream of the sprinkler head
indicating that the domestic service is also used for a fire sprinkler system and must not be left closed
A floor drain is strongly recommended to be located in the vicinity of the sprinkler head
Milton Town Hall | 150 Mary Street, Milton ON L9T 6Z5 | P. (905) 878-7252 | F. (905) 878-6995 | TTY. (905) 878-1657
The Town of Milton is committed to providing accessible formats and communication supports for persons with disabilities. If another format would work
better for you, please contact 905-878-7252 ext. 2109 or visit http://www.milton.ca/en/live/accessiblemilton.asp | TTY at 1-866-786-3941.
www.milton.ca
200mm (8")
200mm (8")
NOTE
ILLUSTRATION FOR
REFERENCE ONLY NOT TO
BE CONSIDERED FOR
DESIGN PURPOSES
COMBINED CONDITION:
SECONDARY EXIT THROUGH THE SIDE ENTRANCE
X_IMP
[X_M]
(EITHER SHARED OR NOT WITH THE UPPER SUITE)
X_IMP
[X_M]
X_IMP
[X_M]
X_IMP X_IMP X_IMP X_IMP A
[X_M] [X_M] [X_M] [X_M]
SHARED EXIT:
EMERGENCY LIGHTING AS
SA
SA PER OBC 2012, DIV.
MIN. 860MM (34'')
BETWEEN THE
B.9.9.12.3. IS REQUIRED. IN
RAILINGS OR DW THIS CASE AN
EL
RAILING AND THE ADDITIONAL FIRE RATED
WALL SHARED EXIT:
DOOR IS REQUIRED AT
UP RISERS
DOOR IS REQUIRED AT
C.H. XXXX
BEDROOM #2 CELLAR LOCATION INDICATED BY THE
Y_IMP
KITCHEN
[Y_M]
C.H. XXXX
DESIGN.
26''x80''
C.H. XXXX
UP
32X80''
A
Y_IMP
[Y_M]
SA CMA
Y_IMP
[Y_M]
Y_IMP
[Y_M]
C.H. XXXX
CARRIED OUT
BY A CERTIFIED UNEX.
PROFESSIONAL
32''x80''
ENGINEER S.D.
Y_IMP
[Y_M]
FURNACE
PROJECT:
SECONDARY SUITES:
DETAILS
HOMEOWNER GUIDELINE PACKAGE
DRAWN BY
PLANS EXAMINATION
www.milton.ca
TOWN OF MILTON, ON
TEAM
BUILDING DIVISION
150MARY STREET, 2D FLOOR,
PLANNING AND DEVELOPMENT PAGE A-05
PROJECT:
SECONDARY SUITES:
DETAILS
HOMEOWNER GUIDELINE PACKAGE
DRAWN BY
PLANS EXAMINATION
www.milton.ca
TOWN OF MILTON, ON
TEAM
BUILDING DIVISION
150MARY STREET, 2D FLOOR,
PLANNING AND DEVELOPMENT PAGE A-06