LED Technology.

The only unit on the market with a complete set


of LEDs optimized to cover all wavelengths (range, 280-750 nm)
required in the enology laboratory.

SEMIAUTOMATIC ANALYZER Minimal reagent consumption.


LED TECHNOLOGY Low maintenance.

BioSystems presents the new Y350 semiautomatic Specific software for color, TPI (Total Polyphenols Index).
analyzer, specifically designed to meet the needs
Preprogrammed enzymatic and chemical kit methods, validated
of enologists, while also optimizing reagent
by the R&D Department.
consumption and minimizing maintenance.
USB port for data export.

Battery-operated.
Can be used in grape intake and fieldwork.

User-configurable accessory.
TECHNICAL SPECIFICATIONS
OPTICAL SYSTEMS CALIBRATION
Range of measurement: Factor
0,2 - 3,5 Absorbance all wavelengths Calibrator
Wavelengths: 280, 340, 405, 420, 505, Calibration Curve
520, 560, 620, 635, 670, 750 nm
Light Source: LEDs CALIBRATION CURVE
Settings: monochromatic and Up to 8 Calibration points
bichromatic
Up to 3 replicates per point
THERMOSTAT SYSTEM QUALITY CONTROL
Peltier system from 25-40 °C DEDICATED REAGENTS
2 controls per test
FLUIDIC SYSTEM Levey-Jennings control chart • Acetaldehyde • Acetic Acid • Ammonia
Westgard´s Rules • Calcium-Eno • Citric Acid • Color
Continuous flow system with peristaltic
pump incorporated INSTALLATION CHARACTERISTICS • Copper • D-Gluconic Acid
Stepper motor pump operation
Voltage: 100V-240 V • D-Glucose/D-Fructose • D-Lactic Acid
Sipping volume can be programmed
from 100 μL to 5 mL Frequency: 50/60 Hz • Free Sulfite • Glycerol • Iron-Eno
Automatic adjustment of sample Maximum power: 30 W • L-Lactic Acid • L-Malic Acid
volume Temperature: 10-35 °C
• Primary Amine Nitrogen (PAN)
Automatic adjustment of sample Max Rel humidity: 75 %
position Height: <2000 m • Polyphenols • Potassium
Dimensions: 420 x 350 x 216 mm • Pyruvic Acid • Sucrose/Total Sugar
PRINTER SCREEN AND KEYBOARD
Weight: 4 kg • Tartaric Acid • Total Sulfite
Thermic printer
Screen: graphic LCD lighted screen ACCESSORIES • Enologycal (Multiparameter calibrator)

Wine Analysis Made Easy


320 x 240 px Battery Pack • Wine Control Red and White
Keyboard: tactile membrane
- Capacity 2000 mAh
METHODS OF CALCULATION - Duration: 2 hrs
1 and 10 mm flow quartz cuvette
Absorbance
End Point 10 mm flow glass cuvette
Differential Mode 1 mm glass cuvette + adapter
Fixed Time 10 mm quartz cuvette
99842

Manufactured by: BioSystems S.A.


Costa Brava 30, 08030 Barcelona (Spain)
BTS/09-14

Tel. +34-93 311 00 00 Fax +34-93 346 77 99


[email protected] www.biosystems.es