Unit Description PSU

DESCRIPTION
Copyright

© Ericsson 2005 – All Rights Reserved

Disclaimer

No part of this document may be reproduced in any form without the written
permission of the copyright owner.

The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use
of this document.

Trademark List

50/1551-HRB 105 102/1 Uen A 2005-05-12


Unit Description PSU

Contents

1 Product Overview 1
1.1 Purpose 2
1.2 Variants 2
1.3 Hardware and Software Compatibilities 3

2 Function Description 3

3 Dimensions 4

4 Power 5
4.1 Voltage Range 5
4.2 Fuses 5

5 Interfaces 5
5.1 Signal and Power Interfaces 5
5.2 Operator Interfaces 6

50/1551-HRB 105 102/1 Uen A 2005-05-12


Unit Description PSU

50/1551-HRB 105 102/1 Uen A 2005-05-12


Unit Description PSU

1 Product Overview

This document describes the Power Supply Unit (PSU).

Figure 1 The PSU-AC

50/1551-HRB 105 102/1 Uen A 2005-05-12 1


Unit Description PSU

Figure 2 The PSU-DC+24 and PSU-DC 48

1.1 Purpose
The PSU converts incoming voltage to 48 V DC system voltage. The unit
which is of the Peripheral Product (PP) type, is available for the following types
of voltage:

• 120 – 250 V AC

• +24 V DC

• 48 to 60 V DC (three-wire)

1.2 Variants
The following variants exist:

• PSU-AC (rectifier that converts 120 – 250 V AC mains power to 48 V DC)

• PSU-DC+24 (converts +24 V DC to 48 V DC)

• PSU-DC-48 (converts a variable input voltage of 40 to 60 V DC to


48 V DC)

2 50/1551-HRB 105 102/1 Uen A 2005-05-12


Unit Description PSU

1.3 Hardware and Software Compatibilities


For information about hardware and software compatibilities for the PSU, see
Compatibilities for Hardware and Software.

2 Function Description

The figures below are block diagrams of the PSU-DC and PSU-AC variants.

Figure 3 PSU-DC

Figure 4 PSU-AC

The PSU consists of the following:

• Input filter – filters incoming sine voltage to prevent unwanted signals from
radiating to or from the PSU

50/1551-HRB 105 102/1 Uen A 2005-05-12 3


Unit Description PSU

• DC/DC converter – converts the incoming voltage to 48 V DC system


voltage

• Output filter (EMC filter) – filters the output voltage to prevent unwanted
signals radiating from the PSU

• Control and supervision circuits

The PSU-AC also contains the following:

• Bridge – rectifies the incoming voltage

• Boost converter – draws a sinusoidal input current from the mains supply
in phase with the input voltage, enabling the power supply to have a high
power factor and low distribution on input current

The PSU:

• Converts incoming voltage to 48 V DC system voltage.

• Detects temperature alarms by means of an internal temperature sensor


located at a critical hot spot.

• Communicates with the Control Basic Unit (CBU)

3 Dimensions

The dimensions of the PSU are shown in the table below.

Table 1 PSU Dimensions


Width (mm) Weight (kg)
60.6 <3.5

Note: The height and depth measurements of the PSU conform to standard
power subrack requirements.

4 50/1551-HRB 105 102/1 Uen A 2005-05-12


Unit Description PSU

4 Power

The power characteristics of the PSU are outlined in the following subsections.

4.1 Voltage Range


The voltage range of each PSU variant is shown in the table below.

Table 2 PSU Voltage Range


PSU Variant Voltage Range
PSU-AC Nominal 120 – 250 V AC
PSU-DC+24 V Nominal 19.5 – 30 V DC
PSU-DC 48 V Nominal 48 to 60 V DC

4.2 Fuses
The AC and DC input is protected by an external fuse.

Table 3 External Input Fuse Information


Attribute +24 V DC AC -48 V DC
Fuse rating 75 A 16 A 40 A
(slow-blow)
Breaking 5 kA 5 kA 5 kA
capacity

5 Interfaces

The interfaces of the PSU are described in the following subsections.

5.1 Signal and Power Interfaces


The external interfaces of the PSU are shown in the table below:

50/1551-HRB 105 102/1 Uen A 2005-05-12 5


Unit Description PSU

Table 4
PSU Descrip- Quantity Connec- Marking Location
Variant tion tor
Common Cable 1 REMA DC out Front
from PSU female
to busbar.
Used for
DC power
Common Cable 1 RJ45, EC bus Front
RS485 8-pole
between
PSU and
AUH.
Used for
equip-
ment con-
trol.
PSU-AC Cable 1 IEC 320 AC in Front
from
ACCU
to PSU.
Used as
PSU AC
input.
PSU-DC Cable 1 REMA DC in Front
from female
DCCU
to PSU.
Used as
PSU DC
input.

5.2 Operator Interfaces


The PSU has the following operator interfaces:

Table 5 PSU LEDs


Color Status
Red Fault (F)
Green Operational (O)
Yellow Information (I)

6 50/1551-HRB 105 102/1 Uen A 2005-05-12