2 gminternational.com
Safety, performance, and reliability
OUR PRODUCTS,
OUR COMMITMENT
GM International designs, engineers and
manufactures a complete range of Intrinsically
Safe and SIL 3 certified devices that meet the
stringest quality requirements, ensuring the
highest production standards in Intrinsically Safe
applications. Our products are used in automation
packages such as DCS - ESD - FGS - BMS - HIPPS -
PLC - SCADA, in several industrial sectors: Oil & Gas,
Petrochemical, Pharmaceutical, Fertilizer, Mining,
Food & Beverages, Marine.
SOCIAL RESPONSIBILITY
We design Intrinsically Safe Instruments and SIL
certified devices in order to prevent accidents and
understand, manage and reduce risks for people
and environment.
Customer satisfaction is the manner in which we
demonstrate our social responsibility to contribute
to sustainable development, minimizing climate
impact and creating a safe and healthy working
environment.
gminternational.com 3
CERTIFIED
INTRINSICALLY SAFE
PRODUCTS
GM International offers a wide range of products that have been proved to comply with the most
severe quality and safety requirements. IEC61508 and IEC61511 standards represent a milestone in
the progress of industry in the achievement of highest levels of safety through the entire instrumented
system lifecycle. The majority of our products are SIL certified as well as our design, manufacturing and
administrative facilities (FSM); reports and certificates from TÜV are also available for download.
4 gminternational.com
Summary
Intrinsically Safe Galvanic Isolators provide the most simple and cost effective means
of implementing Intrinsic Safety into Hazardous Area applications.
STRENGTHS
• Reduced Foot Print: High Density: 6 mm per Channel
• Reduced Bulk Power Supply: Low Power Consumption
• Reduced Cooling Needs: Low Heat Dissipation
• Higher Reliability In & Outdoor: Certified -40° to + 70° C
• Higher Resilience to Surges: 2.5 KV Isolation
• Data Guaranteed by 3rd Party: SIL 3 (2) TÜV certification
• Current & Valid Standard: Certified IEC 61508:2010, Ed.2
• Harsh Environment Resistance: G3 conformal coating
• Lower Ownership Cost: Certified for 20 years operation
• Reduced Spare Inventory: Universal Mounting (Stand Alone
DIN-Rail, Power Bus System and Termination Boards)
• Totally independent Dual Ch.: Dual Power Supply
• Easier Troubleshooting: Status led indication
6
Intrinsically Safe Isolators · D5000 Series | 01
Structure
High GM International D5000 series uses state-of-the-art solutions to achieve the highest
performance for Intrinsically Safe applications; guaranteed by over 15 certification
Performance bodies all over the world.
Fully automated assembly line; 100% complete individual testing; Advance low dissipation
circuitry; Use of high temperature class components; Absence of electrolytic capacitors;
G3 conformal coating; Designed for vibration and high humidity; are just some of the
factors that guarantee a product with:
Operating
temperature
LONGER LIFETIME WIDE FUNCTIONALITY
certified
Capability to withstand higher • More than 25 modules suitable for SIL 2 and SIL 3
from -40°C temperatures, improves the
lifetime in normal conditions.
applications according to IEC61508, IEC61511
• Three port galvanic isolation to eliminate noise,
to +70°C • Operating temperature certified
ground loop problems providing Intrinsic Safety
without a high integrity safety earth connection
from -40°C to +70°C • Line fault alarm detects open or short circuit of field
• Very high reliability in extreme cables
environment applications • Optional power bus DIN-Rail connector
• G3 conformal coating • Standard Termination Board with custom
• Reduced cabinet dimensions, connectors for integration into customized Boards
require less ventilation • EMC Compatibility to EN61000-6-2, EN61000-6-4,
EN61326-1, EN61326-3-1 for safety system
• Wide range DC power supply (18-30 Vdc)
• Certified for Offshore and Maritime applications
gminternational.com 7
01 | D5000 Series · Intrinsically Safe Isolators
Universal The same device can be used in all applications to reduce spare inventory.
Enhanced Power 24 Vdc Power Supply Voltage can be applied to the module by directly connecting to
the plug-in Terminal Block of each module, or via the Power Bus System. The system
Bus Mounting consists of standard DIN-Rail modules mounted on DIN-Rail Bus connectors. The
maximum allowed powering capacity per trunk is 8 A. It is always possible to remove
modules, without disconnecting the bus connector which remains attached to the DIN-
Rail. Communication bus is provided, on suitable models, to transmit via Modbus to DCS
PLC logic solver. Cumulative Fault Alarm indication is provided on the Bus connection.
D5202S redundant power supply feed module provides SPST Relay contact for
common and power supply faults; both supply voltages are independently monitored.
• Redundant 4 Amp power supply with alarm
• Remote alarm indication
• Modules can be combined for additional redundancy
Customized Termination Boards for an easy integration with instrumentation of manufacturers are available:
• ABB • Foxboro • Honeywell • Schneider • Triconex
• Bailey • Hima • Invensys • Siemens • Yokogawa
8 gminternational.com
Intrinsically Safe Isolators · D5000 Series | 01
Special Dual By using two totally independent Power Supply circuits for each dual channel module,
single channel integrity is maintained while drastically reducing space and installation
Channel Feature cost. GM International SIL 3 modules offer the independence of two single channels
achieving an unprecedent 6mm per channel density.
There are no common components hence both channels are SIL 3 certified and can be
used without any architectural limitation.
MODEL D5011D
Channel 1 5+
= Supply 24 Vdc
=
6-
=
2 Wire Tx HHT HHT Source I
+ 7 1 +
? =
In 1 8 2 mA RL Out 1 (SIL 3)
I - = -
Channel 2
=
=
=
2 Wire Tx HHT HHT Source I
+ 9 3 +
? =
In 2 10 4 mA RL Out 2 (SIL 3)
I - = -
- + Termination
Power Bus board
connector
Visit www.gminternational.com to discover more about D5000 Series of our Intrinsically Safe Isolators.
gminternational.com 9
Intrinsically Safe Isolators
D1000 Series
Intrinsic Safety barriers interface with process measurement field devices situated in a
hazardous area of a plant.
STRENGTHS
• Reduced Foot Print: High density, 4 Channels
• Full Application Coverage: All INs and OUTs available
• Reduced Spare Inventory: Available as universal IN/OUT
• Reliable Indoor & Outdoor: Certified -40° to + 60° C
• Resilience to Surge: 1.5 KV isolation
• SIL 3 (2) TÜV certification: Data guaranteed by 3rd Party
• Easy Installation: Din Rail & Power Bus mounting
• Easy Maintenance: Plug-in Enclosure
• Current & Valid Standard: Certified IEC 61508:2010, Ed.2
• Independent SIL certified Dual Ch.: Dual Power Supply
10
10 gminternational.com
Intrinsically Safe Isolators · D1000 Series | 01
Structure
Removable terminal blocks
with engraved identification
Innovated and The D1000 series has some innovated designs to make installation and operation safe
and simple. Some of the key features include removable blue & grey Terminals for easy
cost effective installation, a plug in PCB which can be removed for easy service and maintenance
operations. Configuration is via DIP switches allowing an easy and simple field setup.
design for easy
installation
comsumption, repeatability
• Advanced circuitry provides low heat
I/Os
• Relay contacts rated for 2 A to
dissipation, ensuring modules run cool directly switch high loads
more despite their high functionality • Three port galvanic isolation to
• Low power consumption. eliminate noise, ground loop
functionality • SMD manufacturing for a long and
reliable life
problems and to provide Intrinsic
Safety without a high integrity
• Wide operating temperature range safety earth connection
(-20 / +60°C) • Line fault alarm detects open or
• 2 modules (D1130 - D1180) can be short circuit of field cables
powered from 85 to 264 Vac, 50-400 • Optional Power Bus enclosure
Hz, or from 100 to 350 Vdc
gminternational.com 11
01 | D1000 Series · Intrinsically Safe Isolators
Enhanced Power 24 Vdc power supply voltage can be applied to the module by connecting the voltage
directly to the plug-in Terminal Block of each module, or via Power Bus System. When
Bus Mounting using the optional D1000 Power Bus design, you can supply 12-24VDC directly to
the Power Bus System which has a maximum allowed power capacity of 8 A. When
the Power Bus is used, supply contacts on the terminal blocks are omitted to avoid
accidental short circuits. No need for a complicated energized rail system: the D1000
uses a simple enclosure change to allow the use of the Power Bus feature.
Customized Termination Boards for an easy integration with instrumentation of manufacturers are available:
• ABB • Foxboro • ICS Triplex • Siemens
• Bailey • Hima • Invensys • Triconex
• Emerson • Honeywell • Schneider • Yokogawa
12
12 gminternational.com
Intrinsically Safe Isolators · D1000 Series | 01
SWC1090 Software
The SWC1090 software is designed to provide a PC user interface to configure
programmable D1000 modules. It easily allows the user to:
• Read and write configuration parameters to the units
• Store and restore data to and from local hard drive for backup or archive
• Load factory default configurations
• Monitor Input values via USB/COM port
• Print a report sheet containing configuration
PPC 1090 parameters and additional information
The SWC1090 is freely downloadable from our website.
PPC 1092
El1000ADP Series GM International offers continuity in the service of Elcon Instruments 1000 series
(no longer available from the manufacturer).
Elcon Adapters Features
• ATEX, FM, FM-C Certifications
• Interchangeability with all Elcon 1000 Series modules
• Possibility to replace obsolete modules without modifying wiring or connections
• Designed to be installed on existing Elcon boards
• Identification using the same Elcon part-number
Visit www.gminternational.com to discover more about D1000 Series of our Intrinsically Safe Isolators.
gminternational.com 13
Any time a relay is required and must be used in a SIF, it must conform and adhere to
IEC 61508 and to the relevant industry standard (i.e. 61511).
Typical cases :
SIL certified relays are not used exclusively in Oil & Gas or Petrochemical industries;
they are also a must in many other industries:
• Railways
• Cars and Lift
• Power Distribution
• Any time a failure of the relay can cause a serious accident
STRENGTHS
• Reduced Foot Print: High Density: 12,5/22,5 mm per Ch.
• Full 3rd Party Certification: Coil-to-Contact SIL2/3 TÜV
certified
• True Reliability: Compatible to DO Card LM Pulses
• Reduced Space/Eng. Costs: Smart Line/Load Monitoring
with transparent Fault Indication (no additional contacts)
• Lower Ownership/Maintenance Cost: T-proof Times: 10/20
years
• Reduced Spare Inventory: Universal Mounting: DIN-Rail
and Termination Boards
• Higher Reliability In & Outdoor: Certified -40° to + 70° C
• Totally independent Dual Ch.: Dual circuits
• Full Application Coverage: Modules available with 5 & 10
Amps Contact, NE/ND application
• Harsh environment resistance: G3 conformal coating
• Reliable switching operations: gold-plated relay contacts
14
14 gminternational.com
Safety Relays | 02
Structure
SIL Certified Relays are used for critical loops where careful consideration should be
Line & Load given to Line and Load Monitoring. In a De-energize to Safety application a wire/coil
Monitoring failure leads to a safety status. In an Energize to Safety application line failures leads to a
dangerous status. In both cases failure detection is important, if not essential.
Other diagnostics applications are monitoring the Load status to prevent spurious trips or
to verify the condition of the individual coil in a redundant coil SOV. In F&G system line
diagnostics is a must and regulated by NFPA 72 code.
Control system diagnostic capabilities are designed to work when no device is interposed
between the control system and the load. If a relay is placed in the loop, the diagnostic
function stops at the relay input circuit (coil). To perform line monitoring from field device
to controller, a SIL relay with built-in diagnostic circuit is required. GM International relays
GM INTERNATIONAL PATENTED will perform diagnostics of the load, wire, power supply and internal coils in all operating
DIAGNOSTICS FETATURES conditions; providing an independent alarm contact as well as transparently transferring
the fault indication to compatible DO cards.
(SIL 3) Out
NE or F&G/ND Load
gminternational.com 15
02 | Safety Relays
Universal The same device can be used in all applications to reduce spare inventory.
Enhanced Power 24 Vdc Power Supply Voltage can be applied to the module by directly connecting to
the plug-in Terminal Block of each module, or via the Power Bus System. The system
Bus Mounting consists of standard DIN-Rail modules mounted on DIN-Rail Bus connectors. The
maximum allowed powering capacity per trunk is 8 A. It is always possible to remove
modules, without disconnecting the bus connector which remains attached to the DIN-
Rail. Communication bus is provided, on suitable models, to transmit via Modbus to DCS
PLC logic solver. Cumulative Fault Alarm indication is provided on the Bus connection.
Customized Termination Boards for an easy integration with instrumentation of manufacturers are available:
• ABB • Foxboro • Honeywell • Schneider • Triconex
• Bailey • Hima • Invensys • Siemens • Yokogawa
16
16 gminternational.com
Safety Relays | 02
• Availability: a single fault is not sufficient for a spurious trip of the load
Safety
and
Load
Availability
combined
Line Monitoring Line Monitoring Pulses are generated by DO cards to verify the integrity of the Line and
Load, in either Energized or De-Energized State.
Pulses GM International Relays are compatible to any Line Monitored Pulses and are designed to
prevent:
Compatibility • Contact chattering
• Spurious load activation/deactivation
• Premature damage of the Relay unit.
Pulse testing
PLC/DCS
DO
Compatible
NE Applications Safety Relay
to any Line
Monitored
DO card PLC/DCS
DO Pulse testing
gminternational.com 17
Galvanic Isolators
D6000 Series
GM International new universal mount Galvanic Isolators provide a simple and cost
effective means of implementing isolation in non hazardous applications where SIL
certification and/or high reliability are a requirement.
STRENGTHS
• SIL 2: TÜV certification; according IEC 61508:2010, Ed.2
• Reduced Foot Print: High density: 1, 2, 4 or 8 ch.s each
• Simplified Installation/Config.: DIP switch configurability
• Faster Reaction Time; Lower Down Time: LED indication
for power, signal status and line fault
• Lower Ownership Cost: Certified for 20 years operation
• Reduced Spare Inventory: Universal Mounting (Stand
Alone DIN-Rail, Power Bus System and Termination Boards)
• Improved Reliability: Low power consumption and heat
dissipation
• Higher Reliability In & Outdoor: Certified -40° to + 70° C
• RS-485 Modbus output version available
18
18 gminternational.com
Galvanic Isolators · D6000 Series | 03
Structure
Enhanced GM International SIL 2 certified Isolators are suitable for applications in all industrial
sectors and designed to achieve the highest possible reliability and availability through
Galvanic Isolators the use of high temperature class components and low dissipation circuitry.
By avoiding the use of electrolytical capacitors, and with state-of-the-art assembly and
testing facilities, 20 years useful life time is achieved.
certified lifetime in normal conditions. • Three port galvanic isolation to eliminate noise,
ground loop problems
• Operating temperature • Line fault alarm detects open or short circuit of field
from -40°C certified from -40°C to
+70°C
cables
• Optional power bus DIN-Rail connector
to +70°C
• Very high reliability in • Standard Termination Board with custom
extreme environment connectors for integration into customized Boards
applications. • EMC Compatibility to EN61000-6-2, EN61000-6-4,
• G3 conformal coating EN61326-1, EN61326-3-1 for safety system
• Reduced cabinet • DIP switch configurability for easy field setup
dimensions, require less • LED indication for power, signal status and line fault
ventilation. conditions
• Modules accept DC power supply over a wide
range for 24 Vdc (18-30 Vdc) applications
gminternational.com 19
03 | D6000 Series · Galvanic Isolators
Universal The same device can be used in all applications to reduce spare inventory.
Enhanced Power 24 Vdc Power Supply Voltage can be applied to the module by directly connecting to
the plug-in Terminal Block of each module, or via the Power Bus System. The system
Bus Mounting consists of standard DIN-Rail modules mounted on DIN-Rail Bus connectors. The
maximum allowed powering capacity per trunk is 8 A. It is always possible to remove
modules, without disconnecting the bus connector which remains attached to the DIN-
Rail. Communication bus is provided, on suitable models, to transmit via Modbus to DCS
PLC logic solver. Cumulative Fault Alarm indication is provided on the Bus connection.
D5202S redundant power supply feed module provides SPST Relay contact for
common and power supply faults; both supply voltages are independently monitored.
• Redundant 4 Amp power supply with alarm
• Remote alarm indication
• Modules can be combined for additional redundancy
Customized Termination Boards for an easy integration with instrumentation of manufacturers are available:
• ABB • Foxboro • Honeywell • Schneider • Triconex
• Bailey • Hima • Invensys • Siemens • Yokogawa
20
20 gminternational.com
Galvanic Isolators · D6000 Series | 03
SIL GM International D6000 series is designed and certified SIL 2 according to IEC 61508
ed.2 and 61511 ed.2 latest standards. GM International System Capability SC3 allow the
Certification use of our isolators in 1oo2 or 2oo3 architecture for up to SIL 3 applications.
SIL data is guaranteed for a useful life time of 20 years thanks to GM International’s
state-of-the-art solutions and manufacturing excellence. G3 conformal coating and
vibration proof design guarantee problem free long operation life in standard and harsh
conditions:
20 years
SIL
certification
SIL Marking
gminternational.com 21
21
Power Supplies
PSx1200 Series
SIL 3 certified, 24 Vdc modular power supply suitable for installation in safe area and
Zone/Division 2. Designed for 100% Availability and High Integrity applications;
built-in load sharing in both DIN rail and Rack mounted solutions
STRENGTHS
• Smaller Foot Print: Very compact design
• Flexibility: Wall/Rack/Din Rail Types
• Environmental condition: Extended temperature range
(-40°C ÷ +70°C), G3 Coating, tested for Marine application
(EMC, Vibration, etc.)
• Zone 2 installation: Reduced Cable Distance
• Improved Safety, Integrity and Reliability: SIL 3 certified by
Third Party
• High efficiency - Reduced Bulk Power & Dissipation: Built-
in intelligent load sharing
• Easier Installation: No external OR-ing diodes needed for
redundancy
• Zero Downtime: Built-in Redundancy, operation under
output short-circuit condition, Automatic load sharing of 2
or more modules
• Reduced Maintenance Cost: Hot swapping, also in Zone 2
(PSS1250)
• Guaranteed Fault Isolation: Short Circuit Protection
• Easier Troubleshooting: Local and Remote (Optional
Modbus) diagnostic
22
22 gminternational.com
Power Supplies · PSx1200 Series | 04
Reasons During normal operation, output voltage is considered safe between 20 and 30 Vdc and
safe state is typically when the output voltage is 0 Vdc; or close to it.
for SIL 3 However, all power supplies can fail in conditions different from zero; leading to a
dangerous state that can damage or put the load in an unstable/unsafe condition: Fail
Power Supply High (above 30 Vdc) or Fail Low (Between 2 Vdc and 20 Vdc).
According to the ‘normative section’ of the IEC61508:2010 part 2 - Annex A - table A.9,
the global objective is to detect or tolerate both under-voltage and/or over-voltage and
maintain your safety instrumented functions (SIF) in the normal operating range.
Both failures can potentially lead to a hazardous situation, either damaging the
instruments by overvoltage or not providing the necessary voltage for normal functioning
of the instrument/device.
The majority of the SIF are working on the de-energise to trip principle where the main
concern is availability of the power and is solved with redundancy. However, redundancy
is not the solution for High or Low Voltage failures.
Special notice should be given to Energized to Trip SIF where any failure of the power
supply will put safety at risk.
SIL 3 GM International power supplies are designed and certified to guarantee an output
Power voltage of 20-30 Vdc under normal and fault conditions.
SIL Marking
Reasons High availability systems employ power supply modules connected in parallel to achieve
redundancy and enhance system reliability; typically using a OR-ing Diode.
for Ideal OR-ing OR-ing diodes introduce a significant voltage drop and will not equalize the load (load sharing).
Diode Because of the high dissipated heat, they are often the cause of failure.
GM International Power Supply system makes use of Ideal Diode technology and Load
Sharing circuitry.
gminternational.com 23
04 | PSx1200 Series · Power Supplies
PSD1220
Structure
Output terminals
124,5 mm
PSD1220: 111 mm
PSD1220-098: 124 mm
183 mm PSD1220-098 version with removable
terminals, which are equivalent to
predecessor
20 A, 24 V PSD1220 is the latest addition to the GM International power supply line, offering an
innovative 20 Amps DIN Rail unit.
SIL 3 It supersedes predecessor model PSD1210 doubling the output capacity, yet retaining the
exact same dimensions, terminal blocks and mounting arrangements.
Power Supply Compact in size, yet fully featured: from SIL3 certification to automatic load sharing, high
efficiency and suitable for installation in classified areas.
SPECIFICATIONS
Compact
and •
•
Nominal Input: 110 ÷ 240 Vac ±10% (48 ÷ 62 Hz)
Adjustable Output: 24 ÷ 26 Vdc
Versatile •
•
Current Output: 24 Vdc/20 A = 480W
Efficiency (full load): ≥ 93% @230Vac, ≥ 91% @115Vac
• Under/Over Voltage alarm output
• Up to 10 modules with paralleled outputs
• Built-in Over Load protection and Short Circuit proof
• Extended temperature range (-40°C ÷ +60°C)
• SIL3 Certification
• ATEX / IECEx: Zone 2 Installation
• G3 Conformal Coating
24 gminternational.com
Power Supplies · PSx1200 Series | 04
PSW1250
Structure
Wall-mounting plate
Input Terminals
60,7 mm
362,53mm
261 mm
50 A, 24 V PSW1250 is the most powerful unit GM International can offer in a single Wall or Din Rail
mounted solution.
SIL 3 Innovative design and state-of-the-art circuitry have been used to provide 50 AMPS in
such a small package; with efficiency higher than 89%.
Power Supply All the features of the rack mounted series are made available in this compact solution
with SIL 3 certification and installation in + 70°C ambient temperature.
SPECIFICATIONS
Performance •
•
Adjustable Output: 21 ÷ 28 Vdc
Current Output: 24 Vdc/50 A = 1.200W
• Up to 10 modules with paralleled outputs
• Built-in Over Load protection and Short Circuit proof
• SIL3 Certification
• Redundant Fan with speed control: speed driven by
temperature and output power
• ATEX / IECEx: Zone 2 Installation
• G3 Conformal Coating
gminternational.com 25
04 | PSx1200 Series · Power Supplies
PSS1250
Structure
Redundant AC
connection
237 mm
MONITORED PARAMETERS
26 gminternational.com
Power Supplies · PSx1200 Series | 04
Hot Swapping Hot swapping solution; also certified for Zone 2 installation
Zone 2
HOT
Swapping Redundant screw switch
for Hot Swapping
Technical
Specifications
gminternational.com 27
04 | PSx1200 Series · Power Supplies
PSS1250
Configuration
Examples
PSS1250-HS-7-3-D
Two AC supplies, three redundant 50 A Outputs, PSO1250 overview module.
Three groups of two paralleled modules each.
PSS1250-HS-7-2-D
Two AC supplies, one redundant 100 A + one redundant 50 A Outputs, PSO1250 overview module.
One group of four paralleled modules and one group of two paralleled modules.
DC1 DC2
NOTE
Different configurations are available, refer to www.gminternational.com
28 gminternational.com
Power Supplies · Other Types | 04
Other Power
Supplies Types
PSD5201
SIL 3 Intrinsically Safe Power Supply
• Supply 24 Vdc
• 1 Output 14.5 V - 150 mA
• Output to Zone 0 / Div. 1
• Zone 2 / Div. 2 installation
PSD1000
Universal Input Power Supply for D1000 Series Isolators
PSD1001
SIL 2 / SIL 3 Intrinsically Safe Power Supply
• Supply 24 Vdc
• 4 Independent, parallelable Outputs 15 V, 20 mA
• Output to Zone 0 / Div. 1
• Output short circuit proof and current limited
• High Reliability, SMD components
• High Density, four channels per unit
• Simplified installation using standard DIN Rail and plug-in terminal blocks
• Zone 2 / Div. 2 installation
PSD1001C
SIL 2 / SIL 3 Intrinsically Safe Power Supply
• Supply 24 Vdc
• Output 13.5 V - 100 mA
• Output to Zone 0 / Div. 1
• Output short circuit proof and current limited
• High Reliability, SMD components
• Simplified installation using standard DIN Rail and plug-in terminal blocks
• Zone 2 / Div. 2 installation
gminternational.com 29
Multiplexer Systems
D2000 Series
STRENGTHS
• Reduced Foot Print: High Density: up to 256 Channel
• Longer distances: up to 5 Km
• Higher Reliability: Certified -40° to + 60° C
• Avoid Fault Propagation: Channel to channel isolation
• Resilience to Surges: 500 V Isolation
• Improved Measuring precision: 18 Bits accurancy
• Faster Reaction time: from 0,4 sec for 64 Ch. to 1.6 sec for
256 Ch.
• Faster Data Collection: 112 KBaud Communication Speed
• Reduced Bulk Power Supply: Separate power supply not
required
• Harsh environment resistance: G3 conformal coating
• Easier Troubleshooting: Status led indication
30
30 gminternational.com
Multiplexer Systems · D2000 Series | 05
Structure
Gateway/Power Supply
connectors
78 mm
127 mm
220 mm
Installation example
Cost and •
•
Drastically reduces field wiring & installation costs
Field units can be placed up to 5 km from Gateway
Installation •
•
Eliminates the need of PLC - DCS AI cards
Installation in Zone 1 without the need of external power source or certified enclosures
Savings •
•
Up to 256 signals per system; Maximum 7.936 ch.
18 Bits Resolution and fast communication speed
• Easy, Robust & Field Proven Reliability
• Redundant communication lines to hazardous area (proprietary protocol)
• Redundant communication to PLC/DCS/PC via Modbus RTU
gminternational.com 31
05 | D2000 Series · Multiplexer Systems
System D2000 Multiplexer accepts both analog and digital inputs in the same system allowing
for a variety of potential configurations to fit any application.
Architecture Configurations with only Digital signals or only Analog signal or combination of both are
possible to suit the best solution in terms of cost and cabling.
Following are just some examples of system architecture.
Mux units
Hazardous Area
Hazardous Area
(slaves/expanders)
Safe Area
Safe Area
Config PC Config PC
Gateway Gateway
RS-485
Daisy chain
Output repeater
PLC/DCS/PC PLC/DCS/PC
Multiplexer: When revamping or expansions in the plant are required, the space for adding cables
may be limited or the existing spare cables may be the only ones that can be used.
The Only Wireless solutions have several limitations, high implementation costs, and susceptible to
cyber security risk.
Solution Multiplexing often becomes the only practical solution.
Customized
Solutions
Available
Pre-assembled, fully wired and custom engineered field enclosures are available in
several configurations, size and materials.
Special, custom designed, FISCO cable (CABF008) for connection between field units
and gateway is also available.
32 gminternational.com
Multiplexer Systems · D2000 Series | 05
Hazardous Area For applications in classified Hazardous Areas, each signal must be protected from the
risk of causing ignition of the present flammable mixtures: this requires a safety barrier for
Multiplexing each input channel.
By using an Intrinsically Safe multiplexer solution, EX protection must be applied only to
the communication lines, decreasing complexity, maintenance and costs.
Text
• Configure and monitor the entire system with your PC / Laptop via RS232 and/or
RS485 connections
• Guided user interface
• Print complete report sheets
• Save configurations to file for backup
• Multilanguage
Easy
configuration
gminternational.com 33
Surge Arresters
D9000 Series
D9000 series provides surge protection for all kinds of applications in different
industries such as Oil&Gas, Petrochemical, Steel etc. avoiding signal interruption and
protecting control room equipment.
STRENGTHS
• Easy maintenance: Integrated knife disconnection
technology for each channel
• Quick wiring: Grounding path via contact to DIN rail
• Reduced spare inventory: Surge protection for most I/O
signals; AI, AO, DI, DO. Nominal 24V DC, maximum 36V
(Both I.S. And N.I.S.)
• Increases the Discharge capacity and reduces the
response time: 2-stage protective circuit (Diode, Gas-
Discharge Tube)
• Unlimited IS applications: Input from Zone 0 (Zone 20),
installation in Zone 1 and 2
• Fits in any SIL loop: SIL3 Certification
• Protection Level: up to 20 KA
• Local & remote Faster maintenance reaction time:
Versions available with Fault Indication
• Simple testing and documentation, reduced downtime:
Available with Hot Swap Plug module
• Safe disconnection and signaling in case of overload
34
34 gminternational.com
Surge Arresters · D9000 Series | 06
D9024S
Structure
Circuit switches
a
b
a
2 4
IN OUT
Silkscreen to provide accurate, b
1 3
safe and permanent marking of
parameters and instructions
94,8 mm
69,1 mm
6,2 mm
Universal Din Rail D9024S modules provide two-stage, SIL 3, surge protection for floating I/O signals for
measurement in control and safety systems.
Surge Arrester Its slim width of only 6mm allows for easy fitting into any marshalling or distribution
cabinet saving space and installation costs.
Disconnect knife on both signal paths are featured for easy testing of the loop.
gminternational.com 35
06 | D9000 Series · Surge Arresters
D9400/D9500
Structure
Circuit switches
Terminal blocks
DIN-Rail mounting
106 mm
Cartridge & Fault D9400/D9500 provides surge protection for floating I/O signal circuit in a SIL 3 compact
package with or without removable cartridge configuration. The pluggable module and
Indication disconnect knife enable easy testing.
Also featured local and remote module fault indications.
Surge Arrester In the event of an overload, a status indicator identifies the disconnection of the
protective element without the need of auxiliary power supply; a remote indication set, for
up to 40 modules at a time, is also available.
Intrinsically safe certified for use in IS loops and for hazardous area installation.
Local &
FEATURES
Remote Alarm • SIL 3 according to IEC 61508:2010 Ed.2
Indication •
•
Local and Remote Fault Indication
Disconnection of signal circuit by disconnect knife
• Hot Removable plug module version available
(D9500 version)
• EX-i Certified
• High Density 6.2 mm per channel
• Protection of a floating double wire in intrinsically
circuits
• HART Compatible
36 gminternational.com
Surge Arresters · D9000 Series | 06
D9324S
Structure
28 mm
Screw-on S.S. D9324S provides surge protection for floating I/O signal circuit in a screw-on module
Ex-d certified and with IP67 protection for sensor heads; connection 1/4” NPT.
Surge Arrester Suitable for installation onto explosion proof enclosures for a wide range of
applications.
Field FEATURES
Instrument • SIL 3 according to IEC 61508:2010 Ed.2
Protection • Input from Zone 0 (Zone 20), installation in Zone 1
and 2
• Protection of a floating double wire in intrinsically
safe circuits
• Suitable for explosion proof enclosures
• HART compatible
gminternational.com 37
The new SIL 3 certified GM International HART Interface System drastically reduces
the complexity and cost of HMS installations; compared to the current state-of-the-
art HART interface solutions on the market, GMI HART System significantly cuts the
number of multiplexer modules required and increases the speed of communication
to 115.200 bps
STRENGTHS
• Reduced foot print: High Density: 256 Channel
• Increased Architecture Ability: 63 configurable addresses
• Faster data acquisition: 115.200 Baud Speed
• Reduced wiring: Slaves are not required
• Higher Reliability In & Outdoor: Certified -40° to + 70° C
• Higher resiliance: Channel to channel isolation
• Data Guaranteed by 3rd Party: SIL 3 TÜV certification
• Current & Valid Standard: Certified IEC 61508:2010, Ed.2
• Lower Ownership Cost: Certified for 20 years operation
38
38 gminternational.com
HART Multiplexer System | 07
Structure
HART modem
Blocking clips
Flat connector for
expansions/additional boards
125 mm
147 mm
176 mm Custom Termination Board solution
GMI HART Mux By eliminating the need to use slaves the GM International Hart Multiplexer solution
offers an innovative and low-cost solution for HART Maintenance Station projects.
Solution Each 5700 HART Mux supports up to 256 HART signals with sufficient communication
speed thanks to a baud rate increased to 115.200 bps.
gminternational.com 39
Termination Boards
Standard and customized
Termination boards provide direct connection via dedicated multicore cable between
the I/O Card of the system (PLC/DCS/ESD) and electronic modules (barriers, isolators,
relays).
GM International offers a wide range of standard or customized termination boards to
easily interface to systems of all the main instrumentation vendors such as: Invensys
Foxboro, ABB, Triconex, Yokogawa, Honeywell and many others.
GM International termination boards are also available with the new HART Interface
System that drastically reduces the number of multiplexer modules
STRENGTHS
• Smaller Foot Print: Very compact design, up to 64 I/O
Channels in one Board
• Flexibility: Mounting hardware for DIN Rail or Wall
• High Availability: Power Supply and support of I/O
Redundancy
• Easy maintenance and Troubleshooting: Fault Led
Indication and common fault repeater
• Available with customized connectors/cables for direct
interface to any PLC / DCS / ESD Systems
• Also available with GMI HART Interface System that
drastically reduces the number of multiplexer modules.
• AI/AO/DI/DO Universal: any D5000 or D6000 series
modules can be installed: IS Barriers, Isolators, Safety
Relays
40
40 gminternational.com
Termination Boards | 08
Typical structure
Supply line 1
HART Multiplexer connector
Supply line 2
16 channels output connector
Power ON LEDs 1 - 2
Universal GMI Termination Boards are suitable for installation of any AI/AO/DI/DO modules of the
D5000/D6000 and D1000 series: IS Barriers, Isolators and Safety Relay.
Termination Universal solutions are available using patch cables or can be customized to suit the
growing number of Universal I/O modules.
Boards All Analog TBs support connection to GMI innovative HART Multiplexer solution via flat
or flat-to-round cable.
FEATURES BENEFITS
100% • Redundant power supply connection • Simplified wiring and maintenance
customizable •
•
Line voltage monitoring and alarm
Suitable to host 8/16/32 Modules
• Reduces cabinet and installation
costs
• Up to 64 Channels per TB • Small overall Foot print
• Universal: AI/AO – DI/DO – TEMP./ • System dedicated and compatible
CONVERTER plug-in solution
• Dedicated HART Signals connector • Easy spare/extensions management
• Wall or DIN Rail Mounting
• G3 conformal coating and Zone 2
Installation
gminternational.com 41
Field Indicators
T3000 Series
T3010S offers simple and effective process variable read-out in Hazardous Locations.
Loop powered, 4-20 mA unit with less than 1 V voltage drop designed to display the
process variables in any engineering units between -19999 to +19999.
Clear 20mm height, 7-segments LCD display blinking to indicate over or under-range
conditions.
A protected slot to insert the measured engineering unit label is provided, after the last
digit, for easy identification. Loop tag indication can be also provided.
The indicator is housed in a compact IP 66 enclosure for installation in the field and can
be mounted on flat surface, front panel or 2” pipe or post.
STRENGTHS
• Higher Visibility: Large LCD Display, 20 mm high
• Increased applicability: Low voltage drop (<1 V)
• Easier Maintenance: IP66 Enclosure with 2 chambers
• Wall, Pipe-Post, or Panel mounting
• Simplified Installation: Field configurable
• Improved Reliability: Under and Over range detection
• Easier identification: Protected slot available for
engineering value label
• Hazardous and Safe Area Versions Available
42
42 gminternational.com
Field Indicators | 09
Structure
4 ½ digit display
144 mm
144 mm Mounting options
61 mm
4 ½ Digit Loop T3010S units can be connected in series to a 4-20 mA loop (figure A) or can
be driven from Safe Area to provide local indication in Hazardous Areas up to
Powered Indicator Zone 0 / Div. 1 (figure B).
In both cases, the unit must be protected by a suitable intrinsically safe barrier.
Please check data sheet for further information.
Figure A
Figure B
gminternational.com 43
10 | Product List
Product List
I.S. Barriers
D5000 SERIES
ANALOG INPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
Active Passive Source Sink
D5011 1/2 - - - - 3 12,5 mm HART
D5014 1/2 - 3 12,5 mm HART
D5015 1/2 - 2 12,5 mm HART
D5212Q 4 - 2 22,5 mm Modbus
D5254S 1 - 2 22,5 mm Modbus
D5072 1/2 TC, mV, RTD, Ω, Pot 2 12,5 mm Modbus
D5072S-087 1 2-3-4 wire RTD 2-3-4 wire RTD - 2 12,5 mm RTD to RTD
D5072-096 1/2 TC, mV mV 2 12,5 mm mV to mV
D5273S 1 TC, mV, RTD, Ω, Pot - 2 22,5 mm Modbus
ANALOG OUTPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
D5020 1/2 4-20 mA 4-20 mA 2 12,5 mm HART
DIGITAL INPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
D5030 1/2 Dry contact/Namur Relay 3 12,5 mm
D5031 1/2 Dry contact/Namur Voltage free contact 3 12,5 mm
D5032 1/2 Dry contact/Namur Relay 3 12,5 mm Only for TB
D5034 1/2 Namur Namur - - 3 12,5 mm Transparent for Namur
D5036 1/2 Dry contact/Namur Relay - - 2 12,5 mm No G3 Coating
D5037 1/2 Dry contact/Namur Voltage free contact - - 2 12,5 mm No G3 Coating
D5231E 8 Dry contact/Namur Solid State Relay 2 22,5 mm Logical out func. + Modbus
DIGITAL OUTPUT
Models N. Ch. L.M. Input Output Power supply Alarm SIL Size Note
D5040 1/2 - 24 Vdc Solenoid valve / LED Loop powered - 3 12,5 mm 2..4 Field Selectable Out
D5048S 1 24 Vdc Solenoid valve / LED Loop powered 3 12,5 mm 1..3 Field Selectable Out
D5049S 1 24 Vdc/Dry contact Solenoid valve / LED Bus powered 3 12,5 mm 1..3 Field Selectable Out
D5240T 3 - 24 Vdc/Dry contact Solenoid valve / LED Bus powered - 2 22,5 mm 3..9 Field Selectable Out
D5244 1/2 - 24 Vdc Relay Loop Powered - 2 22,5 mm Voltage Free Relay Out
44 gminternational.com
Product List | 10
OTHERS
Models N. Ch. L.M. Input Output Power supply Alarm SIL Size Note
D5062S 1 - Vibration sensor 0 to -20 V Bus powered - 2 12,5 mm
D5093 1/2 - 24-220 Vdc/Vac Voltage free contact Loop Powered - 3 12,5 mm NIS Digital input module
D5263S 1 - Strain gauges Strain gauges Bus powered - 2 22,5 mm
D5264S 1 Strain gauges 4-20 mA Bus powered 2 22,5 mm Modbus
D5202S - - 24 V, 4 A Bus powered 3 22,5 mm Power feed module
D1000 SERIES
ANALOG INPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
Active Passive Source Sink
D1010 1/2 - 2 22,5 mm HART
D1014 1/2 - - - 2 22,5 mm HART
D1012Q 4 - - - - 22,5 mm
Duplicator, High/Low voltage
D1052 1/2 - - - - 22,5 mm
selector, adder/subtractor
D1053S 1 - - - 2 22,5 mm
D1054S 1 - - 2 22,5 mm HART
D1072 1/2 Universal Temperature 2 22,5 mm Voltage Output
D1073S 1 Universal Temperature - 2 22,5 mm Voltage Output
ANALOG OUTPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
D1020 1/2 4-20 mA 4-20 mA 2 22,5 mm HART
DIGITAL INPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
D1030 1/2 Dry contact/Namur Relay 2 22,5 mm
D1031 2/4 Dry contact/Namur Transistor 2 22,5 mm
D1032 2/4 Dry contact/Namur Relay 2 22,5 mm
D1033 2/4 Dry contact/Namur Transistor 2 22,5 mm
D1034 1/2 Namur Namur - - 3 22,5 mm Transparent for Namur
D1130 1/2 Dry contact/Namur Relay 2 22,5 mm AC Supply
DIGITAL OUTPUT
Models N. Ch. L.M. Input Output Power supply SIL Size Note
D1040Q 4 - 24 Vdc/Dry contact Solenoid valve / LED Bus / Loop powered 3 22,5 mm 1..4 Field SelectableOutputs
D1041Q 4 - 24 Vdc/Dry contact LED Bus / Loop powered 3 22,5 mm 1..4 Field SelectableOutputs
D1042Q 4 - 24 Vdc/Dry contact Solenoid valve / LED Bus / Loop powered 3 22,5 mm 1..4 Field SelectableOutputs
D1043Q 4 - 24 Vdc/Dry contact Solenoid valve / LED Bus / Loop powered 3 22,5 mm 1..4 Field SelectableOutputs
D1044 1/2 - 24 Vdc Relay Loop powered 2 22,5 mm Voltage Free RelayOutput
D1045Y 1 - 24 Vdc/Dry contact Solenoid valve Bus / Loop powered - 22,5 mm for ATOS valve
D1046Y 1 - 24 Vdc/Dry contact Solenoid valve Bus / Loop powered - 22,5 mm for WANDFLUH valve
D1048S 1 24 Vdc Solenoid valve / LED Loop powered 3 22,5 mm 1..3 Field Selectable Out
D1049S 1 24 Vdc/Dry contact Solenoid valve / LED Bus powered 3 22,5 mm 1..3 Field Selectable Out
gminternational.com 45
10 | Product List
OTHERS
Models N. Ch. L.M. Input Output Power supply Alarm Size Note
D1010S-054 1 - mV 4-20 mA Bus powered - 22,5 mm Fast response time
D1022 1/2 - 0-40 mA 0-40 mA Loop powered - 22,5 mm FGS detector
D1035S 1 - Frequency Voltage free contact Bus powered - 22,5 mm
D1060S 1 Frequency Voltage free contact Bus powered 22,5 mm
D1061S 1 - RS422 / RS485 RS232 / RS422 / RS485 Bus powered - 22,5 mm Field Bus compatible
D1062S 1 - Vibration sensor 0 to -20 V Bus powered - 22,5 mm
D1063S 1 - Strain gauges Strain gauges Bus powered - 22,5 mm
D1064S 1 Strain gauges 4-20 mA Bus powered 22,5 mm Modbus
D1080D 2 - 3 wire Sensor Relay Bus powered - 22,5 mm
D1081D 2 - 3 wire Sensor Voltage free contact Bus powered - 22,5 mm
D1180D 2 - 3 wire Sensor Relay Bus powered - 22,5 mm AC Supply
Safety Relays
Contact High Pulse
Model N. Ch. Relay Load NO/NC Coil/Input Diagnostics Note
Rating Availability test
D5090S 1 NE NE NO 24 Vdc 5A - -
D5090S-086 1 ND NE NC 24 Vdc 5A - -
D5091S 1 ND NE/ND NO/NC 24 Vdc 5A - -
D5094S 1 NE/ND NE/ND NO 24 Vdc 5A -
D5095S 1 NE/ND NE/ND NC 24 Vdc 5A -
D5096S 1 NE/ND NE/ND NO 24 Vdc 5A Full diagnostics
D5097S 1 NE/ND NE/ND NC 24 Vdc 5A Full diagnostics
D5098 1/2 NE NE NO 24 Vdc 5A - -
D5290S 1 NE NE NO 24 Vdc 10 A - -
D5290S/SA 1 NE NE NO 24 Vdc 5A - - -
D5290S-078 1 NE/ND NE/ND NO/NC 24 Vdc 5A - - 1, 2 or 4 Loads
D5290S-078/SA 1 NE NE/ND NO/NC 24 Vdc 5A - - - 1, 2 or 3 Loads
D5290S-079 1 NE NE/ND NO/NC 115 Vac 5A - - - 1, 2 or 4 Loads
D5290S-080 1 NE NE NO 115 Vac 10 A - - -
D5290S-084 1 NE NE/ND NO/NC 110 Vdc 5A - - - 1, 2 or 4 Loads
D5290S-091 1 NE NE NO 230 Vac 10 A - - -
D5290S-092 1 NE NE NO 48 Vdc 10 A - - -
D5291S 1 ND NE/ND NO/NC 24 Vdc 10 A - -
D5292 1/2 NE/ND NE/ND NO 24 Vdc 5A - -
D5292S-093 1 NE/ND NE/ND NO/NC 24 Vdc 5A - -
D5293S 1 NE NE NO 24 Vdc 5A - Modbus
D5294S 1 NE/ND NE/ND NO 24 Vdc 5A Programmable, Modbus
D5295S 1 NE/ND NE/ND NC 24 Vdc 5A Programmable, Modbus
46 gminternational.com
Product List | 10
Galvanic Isolators
ANALOG INPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
Active Passive Source Sink
D6011 1/2 - - - - 2 12,5 mm HART
D6014 1/2 - 2 12,5 mm HART
D6015 1/2 - 2 12,5 mm HART
D6212Q 4 - 2 22,5 mm Modbus
D6254S 1 - 2 22,5 mm Modbus
D6072 1/2 TC, mV, RTD, Ω, Pot 2 12,5 mm Modbus
D6072S-087 1 2-3-4 wire RTD 2-3-4 wire RTD - 2 12,5 mm RTD to RTD
D6072-096 1/2 TC, mV mV 2 12,5 mm mV to mV
D6273S 1 TC, mV, RTD, Ω, Pot - 2 22,5 mm Modbus
ANALOG OUTPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
D6020 1/2 4-20 mA 4-20 mA 2 12,5 mm HART
DIGITAL INPUT
Models N. Ch. L.M. Input Output Duplicator Alarm SIL Size Note
D6030 1/2 Dry contact/Namur Relay 2 12,5 mm
D6031 1/2 Dry contact/Namur Voltage free contact 2 12,5 mm
D6032 1/2 Dry contact/Namur Relay 2 12,5 mm Only for TB
D6034 1/2 Namur Namur - - 2 12,5 mm Transparent for Namur
D6036 1/2 Dry contact/Namur Relay - - 2 12,5 mm No G3 Coating
D6037 1/2 Dry contact/Namur Voltage free contact - - 2 12,5 mm No G3 Coating
D6231E 8 Dry contact/Namur Solid State Relay 2 22,5 mm Logical out func. + Modbus
OTHERS
Models N. Ch. L.M. Input Output Power supply Alarm SIL Size Note
D6263S 1 - Strain gauges Strain gauges Bus powered - 2 22,5 mm
D6264S 1 Strain gauges 4-20 mA Bus powered 2 22,5 mm Modbus
gminternational.com 47
10 | Product List
Surge Arresters
N. Removable Fault
Models N. Ch. Signal Type Mounting SIL Size Note
Wires cartridge Indication
D9024S 1 2 24 Vdc AI, AO, DI, DO - - DIN-Rail 3 6 mm
D9410S 1 2 24 Vdc AI, AO, DI, DO - DIN-Rail 3 6 mm
D9420S 1 3 Bus System - DIN-Rail 3 6 mm
D9510S 1 2 24 Vdc AI, AO, DI, DO DIN-Rail 3 6 mm
D9520S 1 3 Bus System DIN-Rail 3 6 mm
D9401S 1 - - - DIN-Rail 3 6 mm Remote Fault indicator Set
D9324S 1 2/3 24 Vdc AI, AO, DI, DO - - 1/2” NPT 3 24 mm
Multiplexer Systems
Installation
Models N. Ch. Input Function Line Monitoring Size Note
Area
D2010M 16 Analog - temperature Field multiplexer Hazardous 220 mm Ch. to Ch. isolation
D2011M 16 Analog - temperature Extender module Hazardous 220 mm Ch. to Ch. isolation
D2030M 32 Digital - Namur Field Multiplexer Hazardous 220 mm Ch. to Ch. isolation
D2050M 256 Signals from Field Units Gateway Safe 220 mm Redundant communication
D2052M 32 DI Signals from D2050M Repeater - Safe 220 mm Relay Output
D2053M 32 DI Signals from D2050M Repeater - Safe 220 mm Voltage free contact Output
D1090Q 4 mA / A Shunt Module - Hazardous 22,5 mm Current Input Shunt
D1094Q 4 V Divider Module - Hazardous 22,5 mm Voltage Input Divider
Power Supplies
Fault Installation
Models Output Mounting SIL Size Note
Indication Area
PSD1000 24 Vdc - 0,6 A DIN-Rail - - Safe or Zone 2 22,5 mm
PSD1000F 24 Vdc - 0,6 A DIN-Rail - Safe or Zone 2 22,5 mm
PSD1001 15 Vdc - 20 mA DIN-Rail - 3 Safe or Zone 2 22,5 mm I.S. Device
PSD1001C 13,5 Vdc - 100 mA DIN-Rail - 3 Safe or Zone 2 22,5 mm I.S. Device
PSD5201 14,5 Vdc - 150 mA DIN-Rail - 3 Safe or Zone 2 22,5 mm I.S. Device
PSD1220 24 Vdc - 20 A DIN-Rail 3 Safe or Zone 2 183 mm
PSD1220-098 24 Vdc - 20 A DIN-Rail 3 Safe or Zone 2 183 mm Replacement of PSD1210
PSW1250 24 Vdc - 50 A Wall-Mount 3 Safe or Zone 2 61 mm
PSM1250 24 Vdc - 50 A Wall-Mount 3 Safe or Zone 2 61 mm
PSO1250 - Wall-Mount - Safe or Zone 2 61 mm Diagnostics module
24 V - 300 A Hot Swap,
PSS1250-HS Wall-Mount 3 Safe or Zone 2 178 / 238 / 482 mm
48 V - 150 A Various size available
24 V - 300 A
PSS1250 Wall-Mount 3 Safe or Zone 2 178 / 238 / 482 mm Various size available
48 V - 150 A
48 gminternational.com
Product List | 10
HART Multiplexer
Models N. Ch. Signal Type Function SIL Size Note
5700 256 HART Signals Master and Slave module 3 12,5 mm From 1 to 256 Channels
TB-D5001-
64 HART Signals Flat cable TB - 176 mm For connection via GMI TB
HRT-003
TB-D5001-
32 HART Signals Hard terminals TB - 218 mm For direct connection to HART signal
HRT-004
Field Indicators
Installation
Models N. Ch. Input Power Supply IP Rating Size Note
Area
T3010S 4,5 4 - 20 mA Loop Powered 65 Hazardous 144 mm Mounting Kit available
T3010S-NIS 4,5 4 - 20 mA Loop Powered 65 Safe 144 mm Mounting Kit available
NOTE
New products are always under development. For the most updated product list please refer to www.gminternational.com
Termination Boards
GMI BOARDS
N. of Signal
Models N. Ch. System Card Detail Size Note
Modules Type
TB-D5008-GMI-001 8 / 16 8 Universal patch cables any 156 mm HART connector
TB-D5008-GMI-002 8 / 16 8 AO patch cables any 166 mm HART connector
TB-D5016-GMI-001 16 / 32 16 Universal patch cables any 300 mm HART connector
TB-D5208-GMI-001 8 / 16 8 Universal patch cables any 230 mm HART connector
CUSTOM BOARDS
Customized Termination Boards for an easy integration with instrumentation of manufacturers are available:
• ABB • Foxboro • ICS Triplex • Siemens
• Bailey • Hima • Invensys • Triconex
• Emerson • Honeywell • Schneider • Yokogawa
NOTE
Custom Termination Boards are in constant development. Please enquire if any desired termination board is missing.
gminternational.com 49
11 | Training & Services
TRAINING COURSES
AND FUNCTIONAL
SAFETY SERVICES
Training courses
CUSTOMER TRAINING
Specialty courses for engineering companies, end users and system integrators are held on topics such
as Intrinsic Safety (IS) and Safety Instrumented System (SIS).
GM International is a course promoter of the TÜV Rheinland Functional Safety Program for Safety
Instrumented Systems (SIS) trainings; see our website for available dates.
Our SIL MANUAL has gained strong popularity with over 50.000 copies delivered.
50 gminternational.com
Training & Services | 11
gminternational.com 51
12 | Softwares, Configuration and Online Tools
SOFTWARE LIST
Details
52 gminternational.com
G.M. International s.r.l.
Via Goffredo Mameli, 53-55 - 20852 Villasanta (MB)
Tel: +39 039 2325 038 - Fax: +39 039 2325 107
www.gminternational.com - [email protected]
www.gminternational.com
Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products
are constantly being further developed and the information presented herein refers to the latest product release. No statements concerning a certain
condition or suitability for a certain application can be derived from our information. The information given does not release the user from the
obligation of own judgment and verification. Terms & Conditions can be found at www.gminternational.com
54 gminternational.com