E3/T3 Interface Plug-In Card FOR Loop-O9500R User'S Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 41

E3/T3 INTERFACE PLUG-IN CARD

FOR Loop-O9500R
USER'S MANUAL

LOOP TELECOMMUNICATION INTERNATIONAL, INC.


8F, NO. 8, HSIN ANN RD.
SCIENCE-BASED INDUSTRIAL PARK
HSINCHU, TAIWAN
Tel: 886-3-578-7696
Fax: 886-3-578-7695
© 2011 Loop Telecommunication International, Inc. All rights reserved.
Version 3 9 SEP 2011
TABLE OF CONTENTS
1 PRODUCT DESCRIPTION ........................................................................................................................ 1
1.1 APPLICATION ILLUSTRATIONS ................................................................................................................. 1
1.2 PRODUCT SPECIFICATIONS .................................................................................................................... 2
2 INSTALLATION ......................................................................................................................................... 3
2.1 MECHANICAL INSTALLATION ................................................................................................................... 3
2.2 ELECTRICAL INSTALLATION .................................................................................................................... 3
2.3 CONFIGURATION SETTINGS .................................................................................................................... 3
3 OPERATION .............................................................................................................................................. 4
3.1 LED INDICATION .................................................................................................................................... 4
4 E3/T3 SETUP PROCEDURE..................................................................................................................... 5
4.1 MENU TREE .......................................................................................................................................... 5
4.1.1 E3 VT-100 Menu Tree for O9500R.............................................................................................. 5
4.1.2 T3 VT-100 Menu Tree for O9500R.............................................................................................. 6
4.2 INITIAL SETUP AND CARD REGISTRATION ................................................................................................ 7
4.3 CHOOSING A TRIB UNIT ....................................................................................................................... 10
4.4 CONFIGURATION SETUP ....................................................................................................................... 11
4.4.1 Setup Screen Access................................................................................................................. 11
4.4.2 Line Interface Type Setup Procedure ........................................................................................ 12
4.4.3 Trace Message & EPSL Setup Procedure ................................................................................ 13
4.4.4 Mapping Mode Setup Procedure ............................................................................................... 14
4.4.5 Customer Informatjon Setup Procedure .................................................................................... 14
4.4.6 TPSG Protection Mode Setup Procedure.................................................................................. 15
4.4.7 TPSG Protection Switch Setup Procedure ................................................................................ 15
4.5 UNIT ALARM SETUP ............................................................................................................................. 16
4.5.1 Setup Screen Access................................................................................................................. 16
4.5.2 SDH/SONET Alarm Mask and Relay Setup Procedure ............................................................ 17
4.5.3 Line Alarm Mask and Relay Setup Procedure........................................................................... 19
4.5.4 Alarm Severity Setup Procedure ............................................................................................... 21
4.5.5 Insert AIS Alarm Setup Procedure............................................................................................. 23
4.5.6 M13 E1/T1 Alarm Mask and Relay Setup.................................................................................. 24
4.6 LOOPBACK AND DIAGNOSTICS SETUP ................................................................................................... 25
4.6.1 Setup Screen Access................................................................................................................. 25
4.6.2 Channel Loopback Setup Procedure......................................................................................... 25
4.6.3 E3/T3 Diagnostics Setup Procedure.......................................................................................... 26
4.6.4 M13-E1/T1 Loopback Test ........................................................................................................ 27
4.6.5 M13-E1/T1 Diagnostics Setup ................................................................................................... 27
4.6.6 M13-E1/T1 Remote Loopback Test........................................................................................... 28
4.7 PERFORMANCE SETUP/CLEAR ............................................................................................................. 28
4.7.1 Setup Screen Access................................................................................................................. 29
4.7.2 Unit Clear Performance Data Procedure ................................................................................... 29
4.7.3 Unit Performance Threshold Setup Procedure......................................................................... 30
4.8 FILE TRANSFER ................................................................................................................................... 31
4.8.1 Setup Screen Access................................................................................................................. 31
4.8.2 Unit Download Firmware Procedure.......................................................................................... 32
4.8.3 Copy Firmware to Standby Unit Procedure ............................................................................... 32
4.9 SNCP/UPSR APS SETUP .................................................................................................................. 33
4.9.1 E3 SNCP/UPSR APS Setup...................................................................................................... 33
4.9.2 E3 SNCP/UPSR Revertive Setup.............................................................................................. 34
4.9.3 T3 SNCP/UPSR APS Setup ...................................................................................................... 35
4.9.4 T3 SNCP/UPSR APS Command............................................................................................... 35
4.9.5 T3 SNCP/UPSR Revertive Setup .............................................................................................. 35

i
LIST OF FIGURES
Figure 1- 1 E3/T3 Interface Card .............................................................................................................. 1
Figure 1- 2 Line 1+1 Protection ............................................................................................................... 1
Figure 1- 3 M13 Function.......................................................................................................................... 2

Figure 4- 1 E3 Interface Card VT-100 Menu Tree for O9500R................................................................. 5


Figure 4- 2 T3 Interface Card VT-100 Menu Tree for O9500R................................................................. 6

LIST OF TABLES

Table 3- 1 LED Indication for E3/T3 Card ................................................................................................. 4

Table 4- 1 Line Interface Type Setting Options....................................................................................... 12


Table 4- 2 Trace Message Setup and EPSL Setting Options #2 ............................................................ 13
Table 4- 3 Mapping Mode Setting Options.............................................................................................. 14
Table 4- 4 TPSG Protection Mode Setting Options ................................................................................ 15
Table 4- 5 SDH/SONET Alarm Mask and Relay Setting Options ........................................................... 17
Table 4- 6 Line Alarm Mask and Relay Setting Options ......................................................................... 19
Table 4- 7 Alarm Severity Setting Options .............................................................................................. 21
Table 4- 8 AIS Alarm Setting Options..................................................................................................... 23
Table 4- 9 M13 E1/T1 Alarm Mode and Relay Setup ............................................................................. 24
Table 4- 10 E3/T3 Loopback Setttings.................................................................................................... 25
Table 4- 11 E3/T3 Diagnostics Setting Options ...................................................................................... 26
Table 4- 12 M 13-E1/T1 Loopback Test Setting Options ........................................................................ 27
Table 4- 13 M1E1/T1 Diagnostics Setting Options ................................................................................ 27
Table 4- 14 Remote Loopback Test Setting Options............................................................................... 28
Table 4- 15 Performance Threshold Setting Options.............................................................................. 30

ii
D Bitte führen Sie das Gerät am Ende seiner Lewbensdauer den zue Verfügung
stehended Rückgabeund Sammelsystemen zu.

GB At the end of the product's useful life, please dispose of it at appropriate collection
points provided in your country

F Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage
approprié.

ES Para preservar el medio ambiente, al final dela vida útil de su producto, depositelo
en los laguares destinado aello de acuerdo con la legislación vigente.

P No final de vida útil do producto, por favor coloque no ponto de recolha apropriado.

I I Onde tutelare l'ambiente, non buttate l'apparecchio trai i normali rifiuti al termine
della sua vita utile, ma portatelo presso i punti DI RACCOLTA specifici per questi
rifiuti previsti dalla normativa vigente.

NL Wij raden u aan het apparant aan het einde van zijn nuttige levensduur, niet bij hey
gewone huisafval te deponeren, maar op de dearvoor bestemde adressen.

DK Når produktet er udtjent, bor det børtskaffes via de sæ rlige indsamlingssteder i


landet.

N Ved slutten av produktets levetid bør det avhendes på en kommunal miljøstasjon


eller leveres til en elektroforhandler.

S Lämna vänligen in produkten på lämplig återvinningsstation när den är förbrukad.

FIN Hävitä tuote käytöiän päättyessä viemällä se asianmukaiseen keräyspisteeseen.

PL Gdy produkt nie nadaje sie juz do dalszego uzytku, nalezy zostawic go w jednym ze
specjalnych punktów zajmujacych sie zbiórka zuzytych producktów w wybranych
miejscach na terenie kraju.

CZ Po skončení jeho životnosti odložte prosím výrobek na přislušném sbĕrném místé


zřízeném dle předpisů ve vaší zemi.

SK Po skončení jeho životnosti odovzdajte prosím zariadenie na príslušnom zbernom


mieste podía platných miestnych predpisov a noriem.

SLO Ko se izdelku izteče življenska doba, ga odnesite na ustrezno zbirno mesto oziroma
ga odvrzite v skladu z veljavnimi predpisi.

GR Στο Тέλος тης λειτουργικής Ζωής του προϊόντος παρακαλώ


Πετξτε το στα ειōικά σημεία που Παρέχονται οτη χωρα σας.

PRC 當產品使用壽命結束,請在你的國家所提供的適當地點做好回收處理

iii
CHAPTER 1 PRODUCT DESCRIPTION

1 PRODUCT DESCRIPTION
The E3/T3 Interface Card is a software selectable plug-in card. There are three E3/T3 ports.
The card is hot-swappable and can be installed in or removed from a Loop-O9500R chassis when the
O9500R device is powered up.

Figure 1- 1 E3/T3 Interface Card

1.1 Application Illustrations


Line 1+1 Protection

Figure 1- 2 Line 1+1 Protection

1
CHAPTER 1 PRODUCT DESCRIPTION

M13 Function

E 1 /T 1

O 9500R E 1 /T 1
XC TU 12 E 1 XC or
TU 11 T 1 XC
XCU

SDH

O 9500R XCU

XC
T 3 - M 13 includes TU 12 E 1 XC or
21 E 1 or 28 T 1 R T 3 RE 1 / T 1 TU 11 T 1 XC
(+ M 13 )

E 1 /T 1

Figure 1- 3 M13 Function

1.2 Product Specifications


E3 Interface
Data Rate 34.368 Mbps ± 20ppm Impedance 75 Ohm Coax
Line Code HDB3 Framing Unframed, G.751
Connector BNC connector Output Mask ETS 300 689 Sec.4.2.1.2 ITU
G.703
Total Ports 3 Jitter ITU G.823

T3 Interface
Data Rate 44.736 Mbps ± 20ppm Impedance 75 Ohm Coax
Line Code B3ZS Framing Unframed, C-bit PARITY, M13
Connector BNC connector Output Mask Bellcore GR-499-core
Total Ports 3 Jitter ITU G.824

2
CHAPTER 2 INSTALLATION

2 INSTALLATION

2.1 Mechanical Installation


The E3/T3 interface card will plug into any tributary slot in the O9500R chassis. E3/T3 interface cards are
hot swappable.

2.2 Electrical Installation


All electrical connections are on the backplane. The electrical connections are made when the card is firmly
seated into a tributary slot in the O9500R chassis.

2.3 Configuration Settings


All configurations can be set with keyboard commands via VT-100 monitor. Please refer to Chapter 4, E3/T3
SETUP PROCEDURES.

3
CHAPTER 3 OPERATION

3 OPERATION

3.1 LED Indication

LED Indication for E3/T3 Card


LED Color Indication
ACTIVE Off Off
Flashing Green Working E3/T3 card
Flashing Amber Standby E3/T3 card
Red Card is unregistered

TEST Off Neither loopback nor diagnostics exist


Flashing Amber Card self-test, Loopback or diagnostics exist
Flashing Red Chip initialization failed

ALM This LED is used to indicate alarm status:TU-LOP, TU-AIS, LP-UNEQ, LP-
PLM, LP-TIM, LP-RDI-P, LP-RDI-S, LP-RDI-C, LP-V5-REI, LP-V5-BIP,
LOS, AIS, UAS, RAI/YEL, LOF, IDLE, C-BITS/P-BITS, FAS
Red Critical alarm message or Major alarm message occurs
Amber Minor alarm message occurs
Green Informative alarm message or no alarm message occurs
Table 3- 1 LED Indication for E3/T3 Card

4
CHAPTER 4 E3/T3 SETUP PROCEDURE

4 E3/T3 SETUP PROCEDURE


The E3/T3 card can be set up as either E3 or T3. This chapter provides detailed setup instructions.

Please note that Tributary cards must be registered with the O9500R device or you will not be able to access
their detailed menu screens.

4.1 Menu Tree

4.1.1 E3 VT-100 Menu Tree for O9500R

Figure 4- 1 E3 Interface Card VT-100 Menu Tree for O9500R

5
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.1.2 T3 VT-100 Menu Tree for O9500R

Figure 4- 2 T3 Interface Card VT-100 Menu Tree for O9500R

6
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.2 Initial Setup and Card Registration


Prior to setting up an E3/T3 Interface Card you must first set up the main O9500R device. After that setup is
complete go to the main Controller Menu for the O9500R. A sample screen is shown below.

You must register your E3/T3 cards on the O9500R device.

Press N to register the unit (ie. register your card).

O9500R === Controller Menu === 17:42:50 07/25/2008

Serial Number : 010551 Device Name : O9500R


Hardware Version: P Start Time : 09:43:39 07/24/2008
Software Version: V1.01.01 07/11/2008 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

The following screen will appear. The slot location of any card in the device shows up on the screen.
Choose the command “Card Registration” and press Enter.
O9500R === Unit Registration === 15:56:22 10/31/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1
#2
#3
#4
==== =============== ================ =================== =================
#11
#12
#13
#14 FXS V1.07.01 09/13/2005
#15 E&M V3.02.o1 07/31/2008
#16 FXO V1.04.01 08/04/2008

Command : Card Registration

<< Press ESC key to return to previous menu >>

7
CHAPTER 4 E3/T3 SETUP PROCEDURE

Use the Tab key to scroll in the Tributary slot that your E3/T3 card is plugged into. Press the Enter key.

Command : Card Registration


Unit : Trib-3

The model of card will appear. Move the cursor to the Registered Model field and scroll in either the E3, T3,
or T3-M13 setting. Press the Enter key.
Note: Before you register the E3T3 card to T3-M13 mode, be sure to enable the M13 function first in the (K)
M13 setup section under the O9500R controller menu. Command path: O9500R controller menu > (S)
System Config Setup > (K) M13 setup.

Command : Card Registration


Unit : Trib-3
Registered Model : E3-PRTD

A registration prompt will appear as the registration takes place.


Registration......SUCCESS!

After registration, the E3/T3 card information will show on the screen:
O9500R === Unit Registration === 15:56:22 10/31/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1
#2
#3 E3-PRTD E3/T3 V1.01.01 03/12/2008
#4
==== =============== ================ =================== =================
#11
#12
#13
#14 FXS V1.07.01 09/13/2005
#15 E&M V3.02.o1 07/31/2008
#16 FXO V1.04.01 08/04/2008

<< Press ESC key to return to previous menu >>

If you have other cards to register do it now. Each plug-in interface card must be registered separately.

Change Protection Mode:


To change the protection mode, you do not need to de-register the card. Simply use the command “Change
Protection Mode”. You can change the card’s protection mode from NP (without protection) to PRTD (with
protection), or vise-versa.

8
CHAPTER 4 E3/T3 SETUP PROCEDURE

Card De-registration:
To de-register a card, please activate the command “Card Un-registration”. The setup procedure is similar to
that of “Card registration”.

Note: If you want to change a registered card from E3 toT3 or vice-versa, you must un-register the card and
re-register it again.

O9500R === Unit Registration === 15:56:22 10/31/2008


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1
#2
#3 E3-PRTD E3/T3 V1.01.01 03/12/2008
#4
==== =============== ================ =================== =================
#11
#12
#13
#14 FXS V1.07.01 09/13/2005
#15 E&M V3.02.o1 07/31/2008
#16 FXO V1.04.01 08/04/2008

Command : Card Un-registration

<< Press ESC key to return to previous menu >>

9
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.3 Choosing a Trib Unit


Press U from the O9500R Controller Menu to select the Tributary slot that E3/T3 card is plugged into.
O9500R === Controller Menu === 17:42:50 07/25/2008

Serial Number : 010551 Device Name : O9500R


Hardware Version: P Start Time : 09:43:39 07/24/2008
Software Version: V1.01.01 07/11/2008 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

A prompt will appear. Use the Tab key to scroll in the card’s Tributary slot number. Press the Enter key.
==>> Press Tab key to select the unit: 1

The unit menu will appear for that card. The card type (E3, T3 or T3-M13) will show on the upper left of the
screen:

Unit 1 E3 === Unit Menu === 15:39:42 03/19/2008

Unit 1 T3 === Unit Menu === 15:39:42 03/19/2008

Unit 1 T3-M13 === Unit Menu === 15:39:42 03/19/2008

10
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.4 Configuration Setup


The Unit Menu path for Config Setup is as follows:

S > Config Setup

Then press one of the following:

A -> Line Interface Type Setup


B -> Trace Message & EPSL Setup
C -> Mapping Mode Setup
D -> Customer information Setup
E -> TPSG Protection Mode Setup
F -> TPSG Protection Switch Setup
Note: Available in T3 mode only.

Screen by screen setup examples are shown below.

4.4.1 Setup Screen Access


To set up the Config, press S from the Unit Menu.
Unit 4 E3 === Unit Menu === 18:03:50 09/02/2011

HW Version : B Card State : Initialization Completed


SW Version : V2.06.02 05/17/2011
Serial NO : 000103

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The Unit Configuration Setup menu will appear. Press A, B, C, D, E, F or G.


Unit 1 E3 === Unit Configuration Setup === 15:46:13 03/19/2008

A -> Line Interface Type Setup


B -> Trace Message & EPSL Setup
C -> Mapping Mode Setup
D -> Customer information Setup
E -> TPSG Protection Mode Setup
F -> TPSG Protection Switch Setup

<< Press ESC key to return to Main Menu or enter a command >>

11
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.4.2 Line Interface Type Setup Procedure


The Unit Menu path for Line Interface Type Setup is as follows:

S > Config Setup


A -> Line Interface Type Setup

The Line Interface Type Setup screen will appear. Note that the setting options differ
according to the card type (E3, T3 or T3-M13).

Table 4- 1 Line Interface Type Setting Options


E3 Fields Settings Default Setting Note
Line Type Unframe, G.751 Unframe
T3 Fields Settings Default Setting Note
Line Type Unframe, C-bit Parity Unframe
Transmit Length 0-225ft, 225-450ft.
T3-M13 Fields Settings Default Setting Note
Line Type Unframe, C-bit Parity, M13-T1, M13-E1 Unframe
Transmit Length 0-225ft, 225-450ft.

Sample screen shown below is for E3.


Unit 1 E3 === Line Interface Setup === 15:51:28 03/19/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port# Line Coding Line Type


===== =========== ============
1 HDB3(E3) Unframe
2 HDB3(E3) Unframe
3 HDB3(E3) Unframe

<< Press ESC key to return to previous menu >>

Sample screen shown below is for T3.


Unit 1 T3 === Line Interface Setup === 15:51:28 03/19/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port# Line Coding Line Type Transmit Length


===== =========== ============ ===============

1 B3ZS(T3) Unframe 0~225ft


2 B3ZS(T3) Unframe 0~225ft
3 B3ZS(T3) Unframe 0~225ft

<< Press ESC key to return to previous menu >>

Sample screen shown below is for T3-M13


Unit 3 T3-M13 === Line Interface Type Setup === 17:58:46
05/13/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port# Line Coding Line Type Transmit Length


===== =========== ============ ===============
1 B3ZS(T3) Unframe 0~225ft
2 B3ZS(T3) Unframe 0~225ft
3 B3ZS(T3) Unframe 0~225ft

<< Press ESC key to return to previous menu >>

Use the arrow keys to move the cursor to each field. Use the Tab key to scroll in your
settings. Press the Enter key. A prompt will ask if you want to change the configuration.
Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)

12
CHAPTER 4 E3/T3 SETUP PROCEDURE

In order to save this configuration you must return to the O9500R Controller Menu and press
V. Full instructions can be found in the O9500R User’s Manual.

4.4.3 Trace Message & EPSL Setup Procedure


The Unit Menu path for Trace Message & EPSL Setup is as follows:

S > Config Setup


B > Trace Message & EPSL Setup

The Trace Message & EPSL Setup screen will appear. Use the arrow keys to move the
cursor to each field. Key in your setting. Press the Enter key.
Unit 3 T3 === Trace Message & EPSL Setup === 13:15:46 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
Channel# : 01

<< Press ESC key to return to previous menu >>

An expanded menu will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.

Table 4- 2 Trace Message Setup and EPSL Setting Options #2

E3/T3 Fields Settings Default Setting Note


J1_LEN NULL, NULL
16-BYTE(Space Padding),
16-BYTE(NULL Padding),
1-BYTE
EXP_J1_MSG Key in a name
TX_J1_MSG Key in a name
HP_EPSL 0~0xFF 0x04 Key in a setting
HP_TX_PSL 0~0xFF 0x04 Key in a setting

M13-E1 & M13-T1 Settings Default Setting Note


J2_LEN NULL, NULL
16-BYTE(Space Padding),
16-BYTE(NULL Padding),
EXP_J2_MSG Key in a name
TX_J0_MSG Key in a name
LP_EPSL 0~0x7 0x02 Key in a setting
LP_TX_PSL 0~0x7 0x02 Key in a setting

Unit 3 T3 === Trace Message & EPSL Setup === 13:15:46 06/15/2009
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort
Port# : Port-1
Channel# : 01

J2_LEN : 16-BYTE(Space Padding)


EXP_J2_MSG : Loop
TX_J2_MSG : Loop

LP_EPSL : 02 ( Asynchronous )
LP_TX_PSL : 02 ( Asynchronous )

<< Press ESC key to return to previous menu >>

13
CHAPTER 4 E3/T3 SETUP PROCEDURE

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

4.4.4 Mapping Mode Setup Procedure


The Unit Menu path for Mapping Mode Setup is as follows:

S > Config Setup


C > Mapping Mode Setup
The Mapping Mode Setup screen will appear. Scroll in your setting. Press the Enter key.
Unit 1 E3 === Mapping Mode Setup === 17:36:23 03/19/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Mapping Mode : AU3

<< Press ESC key to return to previous menu >>

Table 4- 3 Mapping Mode Setting Options

E3/T3 Fields Settings Default Setting Note


Mapping Mode AU3, AU4 AU3

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

4.4.5 Customer Information Setup Procedure


The Unit Menu path for Customer Information Setup is as follows:

S > Config Setup


D > Customer Information Setup

The Customer Information Setup screen will appear. Use the arrow keys to move the cursor
to each field. Key in your customer information. Press the Enter key.
Unit 1 E3 === Customer Information Setup === 18:04:46 03/19/2008
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Port# Customer Information


===== ==================================================================
1 name of link#1__________________
2 name of link#2
3 name of link#3

<< Press ESC key to return to previous menu >>

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

14
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.4.6 TPSG Protection Mode Setup Procedure


The Unit Menu path for TPSG protection Mode Setup is as follows:

S > Config Setup


E > TPSG Protection Mode Setup

The TPSG Protection Mode Setup screen will appear. Use the arrow keys to move the cursor
to each field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 4 TPSG Protection Mode Setting Options


E3/T3 Fields Settings Default Setting Note
TPSG Line (1+1)
Protection
Type
TPSG Revertible, Only for Port Base
Protection Non-revertible (1:1)/Line (1+1)
Mode

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

4.4.7 TPSG Protection Switch Setup Procedure


The Unit Menu path for TPSG Protection Switch Setup is as follows:

S > Config Setup


F > TPSG Protection Switch Setup

The TPSG Protection Switch Setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.
Unit 1 E3 === TPSG Protection Switch Setup === 12:07:57 03/27/2008

Port# Side
===== =====
1 Left
2 Left
3 Left

<< Press ESC key to return to previous menu >>

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

15
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.5 Unit Alarm Setup


The Unit Menu path for Unit Alarm Setup is as follows:

M > Alarm Setup

Then press one of the following:

A > SDH/SONET Alarm mask and relay Setup


B > Line Alarm mask and relay Setup
C > Alarm Severity Setup
D > Insert AIS Alarm Setup
E > M13 E1/T1 Alarm Mask and Relay Setup Note: Available in T3 mode only.

Screen by screen setup examples are shown below.

4.5.1 Setup Screen Access


To set up the Alarms, press M from the Unit Menu.
Unit 4 E3 === Unit Menu === 18:03:50 09/02/2011

HW Version : B Card State : Initialization Completed


SW Version : V2.06.02 05/17/2011
Serial NO : 000103

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The Unit Alarm Setup menu will appear. Press A, B, C, D or E.


Note: E is for T3 mode only.

E3 Unit Alarm Setup Screen:


Unit 1 E3 === Unit Alarm Setup === 10:12:17 03/20/2008

A -> SDH/SONET Alarm mask and relay Setup


B -> Line Alarm mask and relay Setup
C -> Alarm Severity Setup
D -> Insert AIS Alarm Setup

<< Press ESC key to return to Main Menu or enter a command >>

16
CHAPTER 4 E3/T3 SETUP PROCEDURE

T3 Unit Alarm Setup Screen


Unit 3 T3 === Unit Alarm Setup === 13:23:08 06/15/2009

A -> SDH/SONET Alarm mask and relay Setup


B -> Line Alarm mask and relay Setup
C -> Alarm Severity Setup
D -> Insert AIS Alarm Setup
E -> M13 E1/T1 Alarm mask and relay Setup

<< Press ESC key to return to Main Menu or enter a command >>

4.5.2 SDH/SONET Alarm Mask and Relay Setup Procedure


The Unit Menu path for SDH/SONET Alarm Mask and Relay Setup is as follows:

M > Unit Alarm Setup


A > SDH/SONET Alarm Mask and Relay Setup

The SDH/SONET Alarm Mask and Relay Setup screen will appear. Use the arrow keys to
move the cursor to each field. Key in your setting. Press the Enter key.

Table 4- 5 SDH/SONET Alarm Mask and Relay Setting Options

E3/T3 Fields Alarm and Relay Default Setting Note


Settings
AU-LOP
AU-AIS
HP-UNEQ
HP-PLM
HP-TIM ENABLED, DISABLED
HP-RDI-P DISABLED
HP-RDI-S
HP-RDI-C
HP-LOM
HP-REI
HP-B3-BIP

M13 E1/T1 Alarm and Relay Default Setting Note


Fields Settings
TU-LOP
TU-AIS
LP-UNEQ
LP-PLM
LP-TIM ENABLED, DISABLED
LP-RDI-P DISABLED
LP-RDI-S
LP-RDI-C
LP-REI
LP-BIP

17
CHAPTER 4 E3/T3 SETUP PROCEDURE

E3 Alarm Mask and Relay Setup Screen


Unit 1 E3 === Alarm mask and relay Setup === 10:32:15 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

<< Press ESC key to return to previous menu >>

T3 Alarm Mask and Relay Setup Screen


Unit 3 T3 === Alarm mask and relay Setup === 13:25:25 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
Channel# : 01

<< Press ESC key to return to previous menu >>

An expanded screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.
Unit 1 E3 === Alarm mask and relay Setup === 11:40:16 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

type alarm relay


-------- ------- -------
AU-LOP DISABLED DISABLED
AU-AIS DISABLED DISABLED
HP-UNEQ DISABLED DISABLED
HP-PLM DISABLED DISABLED
HP-TIM DISABLED DISABLED
HP-RDI-P DISABLED DISABLED
HP-RDI-S DISABLED DISABLED
HP-RDI-C DISABLED DISABLED
HP-LOM DISABLED DISABLED
HP-REI DISABLED DISABLED
HP-B3-BIP DISABLED DISABLED

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

18
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.5.3 Line Alarm Mask and Relay Setup Procedure


The Unit Menu path for Line Alarm Mask and Relay Setup is as follows:

Note: For M13 Alarm Mask and Relay Setup, please refer to Section 4.5.6.

M > Unit Alarm Setup


B > Line Alarm Mask and Relay Setup

The Line Alarm Mask and Relay setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.
Unit 1 E3 === Alarm mask and relay Setup === 11:20:09 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

<< Press ESC key to return to previous menu >>

An expanded screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.

Table 4- 6 Line Alarm Mask and Relay Setting Options

E3/T3 Alarm Default Relay Default Note


Fields Settings Alarm Settings Relay
Settings Settings
LOS
AIS ENBABLED ENABLE ENABLED DISABLE
UAS , D , D
RAI/YELL DISABLED DISABLE Framed Mode
LOF D Framed Mode
IDLE T3 Framed Mode
FAS E3 Framed Mode
C-BITS T3 C-Bit Parity Framed
Mode
P-BITS T3 M13 Framed Mode

E3 or T3 Unframed Mode Alarm Mask and Relay Setup Screen


Unit 3 E3 === Alarm mask and relay Setup === 13:31:20 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

type alarm relay


-------- ------- -------
LOS ENABLED DISABLED
AIS ENABLED DISABLED
UAS ENABLED DISABLED

<< Press ESC key to return to previous menu >>

19
CHAPTER 4 E3/T3 SETUP PROCEDURE

G.751 Mode (E3 only) Alarm Mask and Relay Setup Screen
Unit 3 E3 === Alarm mask and relay Setup === 13:31:20 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

type alarm relay


-------- ------- -------
LOS ENABLED DISABLED
AIS ENABLED DISABLED
UAS ENABLED DISABLED
RAI ENABLED DISABLED
LOF ENABLED DISABLED
FAS ENABLED DISABLED

<< Press ESC key to return to previous menu >>

C-Bit Parity Mode (T3 only) Alarm Mask and Relay Setup Screen
Unit 3 T3 === Alarm mask and relay Setup === 13:32:10 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

type alarm relay


-------- ------- -------
LOS ENABLED DISABLED
AIS ENABLED DISABLED
UAS ENABLED DISABLED
YELL ENABLED DISABLED
LOF ENABLED DISABLED
IDLE ENABLED DISABLED
C-BITS ENABLED DISABLED

<< Press ESC key to return to previous menu >>

M13 Mode (T3 only) Alarm Mask and Relay Setup Screen
Unit 3 T3 === Alarm mask and relay Setup === 13:32:41 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1

type alarm relay


-------- ------- -------
LOS ENABLED DISABLED
AIS ENABLED DISABLED
UAS ENABLED DISABLED
YELL ENABLED DISABLED
LOF ENABLED DISABLED
IDLE ENABLED DISABLED
P-BITS ENABLED DISABLED

<< Press ESC key to return to previous menu >>

20
CHAPTER 4 E3/T3 SETUP PROCEDURE

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

4.5.4 Alarm Severity Setup Procedure


The Unit Menu path for Insert Alarm Severity Setup is as follows:

M > Unit Alarm Setup


C > Alarm Severity Setup

The Alarm Severity Setup screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 7 Alarm Severity Setting Options

E3/T3 Fields Settings Default Setting Note


H-P Path AU-LOP MAJR
AU-AIS MAJR
HP-UNEQ MINR
HP-PLM INFO, MINR
HP-TIM MINOR, MINR
HP-RDI-P MAJOR, MINR
HP-RDI-S CRITICAL MINR
HP-RDI-C MINR
HP-LOM MAJR
HP-REI MINR
HP-B3-BIP MINR

LP-Path TU-LOP INFO, MAJR


TU-AIS MINOR, MAJR
LP-UNEQ MAJOR, MINR
LOP-PLM CRITICAL MINR
LP-TIM MINR
LP-RDI-P MINR
LP-RDI-S MINR
LP-RDI-C MINR
LP-RDI-C MINR
LP-REI MINR
LP-BIP MINR

Line LOS INFO, MINOR, MAJR


AIS MAJOR, MAJR
UAS CRITICAL MINR
RAI/YELL MINR Framed Mode
LOF MINR Framed Mode
IDLE MINR T3 Framed Mode
FAS MINR E3 Framed Mode
C/P BITS MINR T3 Framed Mode

M13-T1/E1 AIS MAJR T3 M13 Framed


Mode

21
CHAPTER 4 E3/T3 SETUP PROCEDURE

E3 or T3 Unframed Mode Alarm Severity Setup Screen


Unit 1 E3 === Alarm Severity Setup === 12:08:29 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

HP Path Severity LP Path Severity Line Severity


--------------------- --------------------- ---------------------
AU-LOP MAJR TU-LOP MAJR LOS MAJR
AU-AIS MAJR TU-AIS MAJR AIS MAJR
HP-UNEQ MINR LP-UNEQ MINR UAS MINR
HP-PLM MINR LP-PLM MINR
HP-TIM MINR LP-TIM MINR
HP-RDI-P MINR LP-RDI-P MINR
HP-RDI-S MINR LP-RDI-S MINR
HP-RDI-C MINR LP-RDI-C MINR
HP-LOM MAJR LP-REI MINR
HP-REI MINR LP-BIP MINR
HP-B3-BIP MINR

(CRIT:CRITICAL, MAJR:MAJOR, MINR:MINOR, INFO:INFORM)

<< Press ESC key to return to previous menu >>


E3 Framed Mode Alarm Severity Setup Screen
Unit 3 E3 === Alarm Severity Setup === 13:40:57 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

HP Path Severity LP Path Severity Line Severity


--------------------- --------------------- ---------------------
AU-LOP MAJR TU-LOP MAJR LOS MAJR
AU-AIS MAJR TU-AIS MAJR AIS MAJR
HP-UNEQ MINR LP-UNEQ MINR UAS MINR
HP-PLM MINR LP-PLM MINR RAI MINR
HP-TIM MINR LP-TIM MINR LOF MINR
HP-RDI-P MINR LP-RDI-P MINR FAS MINR
HP-RDI-S MINR LP-RDI-S MINR
HP-RDI-C MINR LP-RDI-C MINR
HP-LOM MAJR LP-REI MINR
HP-REI MINR LP-BIP MINR
HP-B3-BIP MINR

(CRIT:CRITICAL, MAJR:MAJOR, MINR:MINOR, INFO:INFORM)

<< Press ESC key to return to previous menu >>

22
CHAPTER 4 E3/T3 SETUP PROCEDURE

T3 Framed Mode Alarm Severity Setup Screen


Unit 3 T3 === Alarm Severity Setup === 13:42:22 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

HP Path Severity LP Path Severity Line Severity


--------------------- --------------------- ---------------------
AU-LOP MAJR TU-LOP MAJR LOS MAJR
AU-AIS MAJR TU-AIS MAJR AIS MAJR
HP-UNEQ MINR LP-UNEQ MINR UAS MINR
HP-PLM MINR LP-PLM MINR YELL MINR
HP-TIM MINR LP-TIM MINR LOF MINR
HP-RDI-P MINR LP-RDI-P MINR IDLE MINR
HP-RDI-S MINR LP-RDI-S MINR C/P-BITS MINR
HP-RDI-C MINR LP-RDI-C MINR
HP-LOM MAJR LP-REI MINR M13-T1/E1 Severity
HP-REI MINR LP-BIP MINR ---------------------
HP-B3-BIP MINR AIS MAJR

(CRIT:CRITICAL, MAJR:MAJOR, MINR:MINOR, INFO:INFORM)

<< Press ESC key to return to previous menu >>

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

4.5.5 Insert AIS Alarm Setup Procedure


The Unit Menu path for Insert AIS Alarm is as follows:

M > Unit Alarm Setup


D > Insert AIS Alarm Setup

The Insert AIS Alarm Setup screen will appear. Use the arrow keys to move the cursor to
each field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 8 AIS Alarm Setting Options

E3/T3 Fields Settings Default Setting Note


AU-LOP to AIS
AU-AIS to AIS
HP-UNEQ to AIS
HP-TIM to AIS
HP-LOM to AIS ENABLE, ENABLE
HP-PLM to AIS DISABLE
HP-LOM to AIS
TU-AIS to AIS
LP-UNEQ to AIS
LP-TIM to AIS
LP-PLM to AIS

23
CHAPTER 4 E3/T3 SETUP PROCEDURE

Unit 1 E3 === Insert AIS Alarm Setup === 14:56:31 03/20/2008


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Type Alarm
------------- --------
AU-LOP to AIS : ENABLE
AU-AIS to AIS : ENABLE
HP-UNEQ to AIS : ENABLE
HP-TIM to AIS : ENABLE
HP-LOM to AIS : ENABLE
HP-PLM to AIS : ENABLE
TU-LOP to AIS : ENABLE
TU-AIS to AIS : ENABLE
LP-UNEQ to AIS : ENABLE
LP-TIM to AIS : ENABLE
LP-PLM to AIS : ENABLE

<< Press ESC key to return to previous menu >>

4.5.6 M13 E1/T1 Alarm Mask and Relay Setup


The Unit Menu path for M13 E1/T1 Alarm Mask and Relay setup is as follows:

M > Unit Alarm Setup


E > M13 E1/T1 Alarm Mask and Relay Setup

The M13 Alarm Mask and Relay Setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 9 M13 E1/T1 Alarm Mode and Relay Setup

M13 E1/T1 Field Settings Default Setting Note


AIS ENABLE, DISABLE
DISABLE

Unit 3 T3 === Alarm mask and relay Setup === 13:47:25 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
Channel# : 01

type alarm relay


-------- ------- -------
AIS DISABLED DISABLED

<< Press ESC key to return to previous menu >>

24
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.6 Loopback and Diagnostics Setup


The Unit Menu path for Loopback and Diagnostics Setup is as follows:

G > Loopback and Diagnostics Setup

Then press one of the following:


A > E3/T3 Loopback Test
B > E3/T3 Diagnostics
C > M13-E1/T1 Loopback Test
D > M13-E1/T1 Diagnostic
E > M13-E1/T1 Remote LoopbackTest
Screen by screen setup examples are shown below.

4.6.1 Setup Screen Access


To set up Loopbacks and Diagnostics, press G from the Unit Menu.
Unit 4 E3 === Unit Menu === 18:03:50 09/02/2011

HW Version : B Card State : Initialization Completed


SW Version : V2.06.02 05/17/2011
Serial NO : 000103

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

4.6.2 Channel Loopback Setup Procedure


The Unit Menu path for Channel Loopback Setup is as follows:

G > Loopback and Diagnostics Setup


A > E3/T3 Loopback Test

Table 4- 10 E3/T3 Loopback Setttings

E3/T3 Fields Settings Default Setting Note


Port-1 LOC = Local Looback
Port-2 OFF, LOC, LLB OFF LLB = Line Looback
Port-3

25
CHAPTER 4 E3/T3 SETUP PROCEDURE

The Port Loopback Test screen will appear. Use the arrow keys to move the cursor to each
field. Use the arrow key place the asterisk (*) beside your desired setting. Press the Enter
key.
Unit 1 E3 === Port Loopback Test === 15:34:56 03/20/2008
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

PORT-1 : *OFF LOC LLB


PORT-2 : *OFF LOC LLB
PORT-3 : *OFF LOC LLB

<< Press ESC key to return to previous menu >>

4.6.3 E3/T3 Diagnostics Setup Procedure


The Unit Menu path for E3/T3 Diagnostics setup is as follows:

G > Loopback and Diagnostics Setup


B > E3/T3 Diagnostics

The E3/T3 Diagnostics screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab to scroll in your desired setting. Press the Enter key.

Table 4- 11 E3/T3 Diagnostics Setting Options

E3/T3 Fields Settings Default Setting Note


Direction Line Side, Optical Side Line Side
Test Pattern OFF, 2^11-1, 2^15-1, OFF
2^20-1, 2^23-1,

Unit 1 E3 === E3/T3 Diagnostics === 15:50:40 03/20/2008


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Send Test Pattern to ==>

Port# : Port-1

<< Press ESC key to return to previous menu >>

An expanded E3/T3 Diagnostics Setup screen will appear.


Unit 1 E3 === E3/T3 Diagnostics === 15:50:40 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Send Test Pattern to ==>

Port# : Port-1
Direction : Line Side
Test Pattern : OFF

<< Press ESC key to return to previous menu >>


A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

26
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.6.4 M13-E1/T1 Loopback Test


The Unit Menu path for M13-E1/T1 Loopback Test is as follows:

G > Loopback and Diagnostics Setup


C > M13-E1/T1 Loopback Test

The Port Loopback Test screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab to scroll in your desired setting. Press the Enter key.

Table 4- 12 M 13-E1/T1 Loopback Test Setting Options

M13-E1/T1 Fields Channel Setting Options Default Setting Note


port-1 1 to 21 OFF, OFF LOC = Local
port-2 (E1) LOC, Loopback
port-3 1 to 28 LLB LLB = Line Loopback
(T1)

Unit 3 T3 === Port Loopback Test === 13:50:46 06/15/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
Port# : Port-1
Channel# : 01

PORT-1 CHANNEL-1 : *OFF LOC LLB

<< Press ESC key to return to previous menu >>

4.6.5 M13-E1/T1 Diagnostics Setup


The Unit Menu path for M13-E1/T1 diagnostics is as follows:

G > Loopback and Diagnostics Setup


D > M13-E1/T1 Diagnostics

The M13-E1/T1 Diagnostics screen will appear. Use the arrow keys to move the cursor to
each field. Use the Tab to scroll in your desired setting. Press the Enter key.
Unit 3 T3 === M13-E1/T1 Diagnostics === 13:51:35 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Send Test Pattern to ==>

Port# : Port-1
Channel# : 1

<< Press ESC key to return to previous menu >>

Table 4- 13 M1E1/T1 Diagnostics Setting Options


M13-E1/T1 Fields Settings Default Setting Note
Direction Line Side, Optical Side Line Side
Test Pattern OFF, 211-1, 215-1, 223-1 OFF

Unit 3 T3 === M13-E1/T1 Diagnostics === 13:51:03 06/15/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Send Test Pattern to ==>

Port# : Port-1
Channel# : 1
Direction : Line Side
Test Pattern : OFF

<< Press ESC key to return to previous menu >>

27
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.6.6 M13-E1/T1 Remote Loopback Test


The Unit Menu path for M13-E1/T1 Remote Loopback Test is as follows:

G > Loopback and Diagnostics Setup


E> M13-E1/T1 Remote Loopback Test

The M13-E1/T1 M13-E1/T1 Remote Loopback Test screen will appear. Use the arrow keys
to move the cursor to each field. After selecting your settings press the Enter key.
Unit 3 T3 === M13-E1/T1 Remote Loopback Test=== 01:24:33 09/04/2009
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
Port# : Port-1

CHANNEL-01 : *OFF ACTIVE CHANNEL-15 : *OFF ACTIVE


CHANNEL-02 : *OFF ACTIVE CHANNEL-16 : *OFF ACTIVE
CHANNEL-03 : *OFF ACTIVE CHANNEL-17 : *OFF ACTIVE
CHANNEL-04 : *OFF ACTIVE CHANNEL-18 : *OFF ACTIVE
CHANNEL-05 : *OFF ACTIVE CHANNEL-19 : *OFF ACTIVE
CHANNEL-06 : *OFF ACTIVE CHANNEL-20 : *OFF ACTIVE
CHANNEL-07 : *OFF ACTIVE CHANNEL-21 : *OFF ACTIVE
CHANNEL-08 : *OFF ACTIVE CHANNEL-22 : *OFF ACTIVE
CHANNEL-09 : *OFF ACTIVE CHANNEL-23 : *OFF ACTIVE
CHANNEL-10 : *OFF ACTIVE CHANNEL-24 : *OFF ACTIVE
CHANNEL-11 : *OFF ACTIVE CHANNEL-25 : *OFF ACTIVE
CHANNEL-12 : *OFF ACTIVE CHANNEL-26 : *OFF ACTIVE
CHANNEL-13 : *OFF ACTIVE CHANNEL-27 : *OFF ACTIVE
CHANNEL-14 : *OFF ACTIVE CHANNEL-28 : *OFF ACTIVE

<< Press ESC key to return to previous menu >>

Table 4- 14 Remote Loopback Test Setting Options

M13-E1/T1 Fields Channel Settings Default Setting Note


Port-1 1 to 21 E1 OFF, OFF
Port-2 1 to 28 T1 ACTIVE
Port-3

4.7 Performance Setup/Clear


The Unit Menu path for Performance Setup/Clear is as follows:

R > Performance Setup/Clear

Then press one of the following:

A > Unit Clear Performance Data


B > Unit Performance Threshold Setup

Screen by screen setup examples are shown below.

28
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.7.1 Setup Screen Access


To set up Performance Setup/Clear, press R from the Unit Menu.
Unit 4 E3 === Unit Menu === 18:03:50 09/02/2011

HW Version : B Card State : Initialization Completed


SW Version : V2.06.02 05/17/2011
Serial NO : 000103

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The Performance Setup/Clear screen will appear. Press A or B.


Unit 1 E3 === Performance Setup/Clear === 16:11:10 03/20/2008

A -> Unit Clear Performance Data


B -> Unit Performance Threshold Setup

<< Press ESC key to return to Main Menu or enter a command >>

4.7.2 Unit Clear Performance Data Procedure


The Unit Menu path for Unit Clear Performance Data is as follows:

R > Performance Setup/Clear


A > Unit Clear Performance Data

A prompt will ask if you want to clear the performance data. Use the Tab key to select the port
you want to clear. Press Y for yes.
Unit 1 E3 === Performance Setup/Clear === 16:13:53 03/20/2008

A -> Unit Clear Performance Data


B -> Unit Performance Threshold Setup

>> Use TAB key to select port, and ENTER key to clear performance: All Ports
A prompt will ask “Are you sure?” Press Y for Yes

29
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.7.3 Unit Performance Threshold Setup Procedure


The Unit Menu path for Unit Performance Threshold Setup is as follows:

R > Performance Setup/Clear


B > Unit Performance Threshold Setup

The Unit Performance Threshold Setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 15 Performance Threshold Setting Options

E3/T3 Monitor En/Dis EN/DIS Severity Severity Threshold Default


Fields Point Setting Default Settings Default Settings Thresh.
Setting Setting Setting
Monitor HIP-BIP 02400
Point (B3 ) EN, DISABLE INFO, INFO Setting
HP-REI DIS CRIT. range is 02400
LP-VIP (V5) MAJR 1~99999 00600
LP-REI (V5 MINR 00600
LP-BIP (B3) 02400
LP-REI (B3) 19200
Line 02400
FAS 00044
P-BITS/ 00044
C-BITS

E3 Performance Threshold Screen


Unit 1 E3 === Performance Threshold Setup === 16:38:29 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Monitor Point En/Dis severity Threshold


HP-BIP(B3) DIS INFO 02400
HP-REI DIS INFO 02400
LP-BIP(V5) DIS INFO 00600
LP-REI(V5) DIS INFO 00600
LP-BIP(B3) DIS INFO 02400
LP-REI(B3) DIS INFO 19200
LINE DIS INFO 02400
FAS DIS INFO 00044

<< Press ESC key to return to previous menu >>

T3 Performance Threshold Screen


Unit 3 T3 === Performance Threshold Setup === 13:58:53 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Monitor Point En/Dis severity Threshold


HP-BIP(B3) DIS INFO 02400
HP-REI DIS INFO 02400
LP-BIP(V5) DIS INFO 00600
LP-REI(V5) DIS INFO 00600
LP-BIP(B3) DIS INFO 02400
LP-REI(B3) DIS INFO 19200
LINE DIS INFO 02400
P-BITS/C-BITS DIS INFO 00044

<< Press ESC key to return to previous menu >>

A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.

30
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.8 File Transfer


The Unit Menu path for File Transfer is as follows:

L > File Transfer

Then press one of the following:


A > Unit Download Firmware
B > Copy Firmware to Standby Unit

Screen by screen setup examples are shown below.

4.8.1 Setup Screen Access


To set up a File Transfer, press L from the Unit Menu.
Unit 4 E3 === Unit Menu === 18:03:50 09/02/2011

HW Version : B Card State : Initialization Completed


SW Version : V2.06.02 05/17/2011
Serial NO : 000103

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The File Transfer screen will appear. Press A or B.


Unit 1 E3 ===File Transfer=== 17:55:16 03/20/2008

A -> Unit Download Firmware


B -> Copy Firmware to Standby Unit

<< Press ESC key to return to Main Menu or enter a command >>

31
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.8.2 Unit Download Firmware Procedure


The Unit Menu path for Unit Download Firmware is as follows:
L > File Transfer
A > Unit Download Firmware

The Unit Download Firmware Setup screen will appear. Use the arrow keys to move the
cursor. Key in the TFTP Server IP address and the firmware file name. Press the Enter key.
Unit 1 E3 === Unit Download Firmware === 17:56:29 03/20/2008
ARROW KEYS: CURSOR MOVE, Please Input: nnn.nnn.nnn.nnn, BACKSPACE to edit

Firmware 1 Version : V1.01.01 12/25/2007


Firmware 2 Version : V1.01.01 03/12/2008
Current Firmware Bank: 2
Next Boot Firmware : 2
TFTP Server IP : 000.000.000.000
Firmware File Name :

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

A prompt will ask if you really want to download. Press Y for yes.
Really want to Download ?

4.8.3 Copy Firmware to Standby Unit Procedure


The Unit Menu path for Copy Firmware to Standby unit is as follows:
L > File Transfer
B > Copy Firmware to Standby Unit

The Copy firmware to standby unit screen will appear. A prompt will ask if you are sure.
Press Y for yes. The copying will occur immediately.
Unit 1 E3 ===File Transfer=== 17:44:17 04/03/2008

Copy firmware to standby unit - are you sure ? Y \ 605


Copy Complete.

<< Press ESC key to return to previous menu >>

32
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.9 SNCP/UPSR APS Setup


VT-100 menus vary depending on card type (E3 or T3). Full setup procedures are detailed
below.

Note: You must set up a cross-connect map before the SNCP/UPSR APS Setup will function.
Cross-connect mapping instructions can be found in the user’s manual for O9500R
controller.

4.9.1 E3 SNCP/UPSR APS Setup


The Unit Menu path for SNCP/UPSR APS Setup is as follows:

D > SNCP/UPSR APS Setup

Screen by screen setup examples are shown below.

To set up SNCP/UPSR APS Setup, press D from the Unit Menu.


Unit 4 E3 === Unit Menu === 18:03:50 09/02/2011

HW Version : B Card State : Initialization Completed


SW Version : V2.06.02 05/17/2011
Serial NO : 000103

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR APS status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The SNCP/UPSR APS Setup screen will appear. Press A or B.


Unit 4 E3 === SNCP/UPSR APS Setup === 18:04:04 09/02/2011

A -> SNCP/UPSR APS Command


B -> SNCP/UPSR Revertive Setup

<< Press ESC key to return to Main Menu or enter a command >>

33
CHAPTER 4 E3/T3 SETUP PROCEDURE

E3 SNCP/UPSR APS Command


The Unit Menu path for SNCP/UPSR APS Command is as follows:

D > SNCP/UPSR APS Setup


A > SNCP/UPSR APS Command

The SNCP/UPSR APS Command screen will appear. Use the arrow keys to move the cursor.
Key in the Port number. Use the Tab key to scroll in the Command setting. Press the Enter
key. A prompt will ask if you are sure. Press Y for yes.

Unit 4 E3 === SNCP/UPSR APS Command === 18:04:15 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 1

Command : Clear

Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary

<< Press ESC key to return to previous menu >>

A prompt will appear on the screen to tell you that the command has been accepted.
APS Cmd Accepted!

4.9.2 E3 SNCP/UPSR Revertive Setup


The Unit Menu path for SNCP/UPSR Revertive Setup is as follows:

D > SNCP/UPSR APS Setup


B > SNCP/UPSR Revertive Setup

The SNCP/UPSR Revertive Setup screen will appear. Use the arrow keys to move the cursor
to each field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4-1 E3 SNCP/UPSR Revertive Setting Options

Card Port Channel Revertive Default Note


Model Settings Setting
E3 1~3 Revertive, There is no channel setting for
NonRevertive Non-Revertive E3

Unit 4 E3 === SNCP/UPSR Revertive Setup === 18:04:26 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 1

Revertive: Non-Revertive

<< Press ESC key to return to previous menu >>

34
CHAPTER 4 E3/T3 SETUP PROCEDURE

4.9.3 T3 SNCP/UPSR APS Setup


The Unit Menu path for SNCP/UPSR APS Setup is as follows:

D > SNCP/UPSR APS Setup


A > SNCP/UPSR APS Command

The SNCP/UPSR APS Setup screen will appear. Press A or B.


Unit 7 T3 === SNCP/UPSR APS Setup === 18:04:04 09/02/2011

A -> SNCP/UPSR APS Command


B -> SNCP/UPSR Revertive Setup

<< Press ESC key to return to Main Menu or enter a command >>

4.9.4 T3 SNCP/UPSR APS Command

The SNCP/UPSR APS Command screen will appear. Use the arrow keys to move the cursor.
Key in the Port number. Scroll in the Channel #. Use the Tab key to scroll in the Command
setting. Press the Enter key. A prompt will ask if you are sure. Press Y for yes.
Another screen appears.

Unit 7 T3 === SNCP/UPSR APS Command === 18:04:04 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port : 1_
Channel# : 01

Command : Clear

Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary

<< Press ESC key to return to previous menu >>


Note: The channel # is for M13 function only.

A prompt will appear on the screen to tell you that the command has been accepted.
APS Cmd Accepted!

4.9.5 T3 SNCP/UPSR Revertive Setup


The Unit Menu path for SNCP/UPSR Revertive Setup is as follows:

D > SNCP/UPSR APS Setup


B > SNCP/UPSR Revertive Setup

The SNCP/UPSR Revertive Setup screen will appear. Use the arrow keys to move the cursor
to each field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4-2 T3 SNCP/UPSR Revertive Setting Options

Card Port Channel Revertive Default Note


Model Settings Setting
T3 1~3 1 to 21 E1 Revertive, Only M13 E1/T1 has a channel
1 to 28 T1 NonRevertive Non-Revertive setting

35
CHAPTER 4 E3/T3 SETUP PROCEDURE

Unit 7 T3 === SNCP/UPSR Revertive Setup === 18:04:04 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 1
Channel : 01

Revertive: Non-Revertive

Success!!!
>>Are you sure (Y/N)?Y

36