E3/T3 Interface Plug-In Card FOR Loop-O9500R User'S Manual
E3/T3 Interface Plug-In Card FOR Loop-O9500R User'S Manual
E3/T3 Interface Plug-In Card FOR Loop-O9500R User'S Manual
FOR Loop-O9500R
USER'S MANUAL
i
LIST OF FIGURES
Figure 1- 1 E3/T3 Interface Card .............................................................................................................. 1
Figure 1- 2 Line 1+1 Protection ............................................................................................................... 1
Figure 1- 3 M13 Function.......................................................................................................................... 2
LIST OF TABLES
ii
D Bitte führen Sie das Gerät am Ende seiner Lewbensdauer den zue Verfügung
stehended Rückgabeund Sammelsystemen zu.
GB At the end of the product's useful life, please dispose of it at appropriate collection
points provided in your country
F Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage
approprié.
ES Para preservar el medio ambiente, al final dela vida útil de su producto, depositelo
en los laguares destinado aello de acuerdo con la legislación vigente.
P No final de vida útil do producto, por favor coloque no ponto de recolha apropriado.
I I Onde tutelare l'ambiente, non buttate l'apparecchio trai i normali rifiuti al termine
della sua vita utile, ma portatelo presso i punti DI RACCOLTA specifici per questi
rifiuti previsti dalla normativa vigente.
NL Wij raden u aan het apparant aan het einde van zijn nuttige levensduur, niet bij hey
gewone huisafval te deponeren, maar op de dearvoor bestemde adressen.
PL Gdy produkt nie nadaje sie juz do dalszego uzytku, nalezy zostawic go w jednym ze
specjalnych punktów zajmujacych sie zbiórka zuzytych producktów w wybranych
miejscach na terenie kraju.
SLO Ko se izdelku izteče življenska doba, ga odnesite na ustrezno zbirno mesto oziroma
ga odvrzite v skladu z veljavnimi predpisi.
PRC 當產品使用壽命結束,請在你的國家所提供的適當地點做好回收處理
iii
CHAPTER 1 PRODUCT DESCRIPTION
1 PRODUCT DESCRIPTION
The E3/T3 Interface Card is a software selectable plug-in card. There are three E3/T3 ports.
The card is hot-swappable and can be installed in or removed from a Loop-O9500R chassis when the
O9500R device is powered up.
1
CHAPTER 1 PRODUCT DESCRIPTION
M13 Function
E 1 /T 1
O 9500R E 1 /T 1
XC TU 12 E 1 XC or
TU 11 T 1 XC
XCU
SDH
O 9500R XCU
XC
T 3 - M 13 includes TU 12 E 1 XC or
21 E 1 or 28 T 1 R T 3 RE 1 / T 1 TU 11 T 1 XC
(+ M 13 )
E 1 /T 1
T3 Interface
Data Rate 44.736 Mbps ± 20ppm Impedance 75 Ohm Coax
Line Code B3ZS Framing Unframed, C-bit PARITY, M13
Connector BNC connector Output Mask Bellcore GR-499-core
Total Ports 3 Jitter ITU G.824
2
CHAPTER 2 INSTALLATION
2 INSTALLATION
3
CHAPTER 3 OPERATION
3 OPERATION
ALM This LED is used to indicate alarm status:TU-LOP, TU-AIS, LP-UNEQ, LP-
PLM, LP-TIM, LP-RDI-P, LP-RDI-S, LP-RDI-C, LP-V5-REI, LP-V5-BIP,
LOS, AIS, UAS, RAI/YEL, LOF, IDLE, C-BITS/P-BITS, FAS
Red Critical alarm message or Major alarm message occurs
Amber Minor alarm message occurs
Green Informative alarm message or no alarm message occurs
Table 3- 1 LED Indication for E3/T3 Card
4
CHAPTER 4 E3/T3 SETUP PROCEDURE
Please note that Tributary cards must be registered with the O9500R device or you will not be able to access
their detailed menu screens.
5
CHAPTER 4 E3/T3 SETUP PROCEDURE
6
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration
[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default
The following screen will appear. The slot location of any card in the device shows up on the screen.
Choose the command “Card Registration” and press Enter.
O9500R === Unit Registration === 15:56:22 10/31/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
7
CHAPTER 4 E3/T3 SETUP PROCEDURE
Use the Tab key to scroll in the Tributary slot that your E3/T3 card is plugged into. Press the Enter key.
The model of card will appear. Move the cursor to the Registered Model field and scroll in either the E3, T3,
or T3-M13 setting. Press the Enter key.
Note: Before you register the E3T3 card to T3-M13 mode, be sure to enable the M13 function first in the (K)
M13 setup section under the O9500R controller menu. Command path: O9500R controller menu > (S)
System Config Setup > (K) M13 setup.
After registration, the E3/T3 card information will show on the screen:
O9500R === Unit Registration === 15:56:22 10/31/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
If you have other cards to register do it now. Each plug-in interface card must be registered separately.
8
CHAPTER 4 E3/T3 SETUP PROCEDURE
Card De-registration:
To de-register a card, please activate the command “Card Un-registration”. The setup procedure is similar to
that of “Card registration”.
Note: If you want to change a registered card from E3 toT3 or vice-versa, you must un-register the card and
re-register it again.
9
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration
[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default
A prompt will appear. Use the Tab key to scroll in the card’s Tributary slot number. Press the Enter key.
==>> Press Tab key to select the unit: 1
The unit menu will appear for that card. The card type (E3, T3 or T3-M13) will show on the upper left of the
screen:
10
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
11
CHAPTER 4 E3/T3 SETUP PROCEDURE
The Line Interface Type Setup screen will appear. Note that the setting options differ
according to the card type (E3, T3 or T3-M13).
Use the arrow keys to move the cursor to each field. Use the Tab key to scroll in your
settings. Press the Enter key. A prompt will ask if you want to change the configuration.
Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
12
CHAPTER 4 E3/T3 SETUP PROCEDURE
In order to save this configuration you must return to the O9500R Controller Menu and press
V. Full instructions can be found in the O9500R User’s Manual.
The Trace Message & EPSL Setup screen will appear. Use the arrow keys to move the
cursor to each field. Key in your setting. Press the Enter key.
Unit 3 T3 === Trace Message & EPSL Setup === 13:15:46 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
Channel# : 01
An expanded menu will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.
Unit 3 T3 === Trace Message & EPSL Setup === 13:15:46 06/15/2009
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort
Port# : Port-1
Channel# : 01
LP_EPSL : 02 ( Asynchronous )
LP_TX_PSL : 02 ( Asynchronous )
13
CHAPTER 4 E3/T3 SETUP PROCEDURE
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
The Customer Information Setup screen will appear. Use the arrow keys to move the cursor
to each field. Key in your customer information. Press the Enter key.
Unit 1 E3 === Customer Information Setup === 18:04:46 03/19/2008
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
14
CHAPTER 4 E3/T3 SETUP PROCEDURE
The TPSG Protection Mode Setup screen will appear. Use the arrow keys to move the cursor
to each field. Use the Tab key to scroll in your settings. Press the Enter key.
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
The TPSG Protection Switch Setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.
Unit 1 E3 === TPSG Protection Switch Setup === 12:07:57 03/27/2008
Port# Side
===== =====
1 Left
2 Left
3 Left
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
15
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
16
CHAPTER 4 E3/T3 SETUP PROCEDURE
<< Press ESC key to return to Main Menu or enter a command >>
The SDH/SONET Alarm Mask and Relay Setup screen will appear. Use the arrow keys to
move the cursor to each field. Key in your setting. Press the Enter key.
17
CHAPTER 4 E3/T3 SETUP PROCEDURE
An expanded screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.
Unit 1 E3 === Alarm mask and relay Setup === 11:40:16 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
18
CHAPTER 4 E3/T3 SETUP PROCEDURE
Note: For M13 Alarm Mask and Relay Setup, please refer to Section 4.5.6.
The Line Alarm Mask and Relay setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.
Unit 1 E3 === Alarm mask and relay Setup === 11:20:09 03/20/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
An expanded screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.
19
CHAPTER 4 E3/T3 SETUP PROCEDURE
G.751 Mode (E3 only) Alarm Mask and Relay Setup Screen
Unit 3 E3 === Alarm mask and relay Setup === 13:31:20 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
C-Bit Parity Mode (T3 only) Alarm Mask and Relay Setup Screen
Unit 3 T3 === Alarm mask and relay Setup === 13:32:10 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
M13 Mode (T3 only) Alarm Mask and Relay Setup Screen
Unit 3 T3 === Alarm mask and relay Setup === 13:32:41 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
20
CHAPTER 4 E3/T3 SETUP PROCEDURE
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
The Alarm Severity Setup screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab key to scroll in your settings. Press the Enter key.
21
CHAPTER 4 E3/T3 SETUP PROCEDURE
22
CHAPTER 4 E3/T3 SETUP PROCEDURE
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
The Insert AIS Alarm Setup screen will appear. Use the arrow keys to move the cursor to
each field. Use the Tab key to scroll in your settings. Press the Enter key.
23
CHAPTER 4 E3/T3 SETUP PROCEDURE
Type Alarm
------------- --------
AU-LOP to AIS : ENABLE
AU-AIS to AIS : ENABLE
HP-UNEQ to AIS : ENABLE
HP-TIM to AIS : ENABLE
HP-LOM to AIS : ENABLE
HP-PLM to AIS : ENABLE
TU-LOP to AIS : ENABLE
TU-AIS to AIS : ENABLE
LP-UNEQ to AIS : ENABLE
LP-TIM to AIS : ENABLE
LP-PLM to AIS : ENABLE
The M13 Alarm Mask and Relay Setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.
Unit 3 T3 === Alarm mask and relay Setup === 13:47:25 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
Channel# : 01
24
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
25
CHAPTER 4 E3/T3 SETUP PROCEDURE
The Port Loopback Test screen will appear. Use the arrow keys to move the cursor to each
field. Use the arrow key place the asterisk (*) beside your desired setting. Press the Enter
key.
Unit 1 E3 === Port Loopback Test === 15:34:56 03/20/2008
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
The E3/T3 Diagnostics screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab to scroll in your desired setting. Press the Enter key.
Port# : Port-1
Port# : Port-1
Direction : Line Side
Test Pattern : OFF
26
CHAPTER 4 E3/T3 SETUP PROCEDURE
The Port Loopback Test screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab to scroll in your desired setting. Press the Enter key.
The M13-E1/T1 Diagnostics screen will appear. Use the arrow keys to move the cursor to
each field. Use the Tab to scroll in your desired setting. Press the Enter key.
Unit 3 T3 === M13-E1/T1 Diagnostics === 13:51:35 06/15/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : Port-1
Channel# : 1
Port# : Port-1
Channel# : 1
Direction : Line Side
Test Pattern : OFF
27
CHAPTER 4 E3/T3 SETUP PROCEDURE
The M13-E1/T1 M13-E1/T1 Remote Loopback Test screen will appear. Use the arrow keys
to move the cursor to each field. After selecting your settings press the Enter key.
Unit 3 T3 === M13-E1/T1 Remote Loopback Test=== 01:24:33 09/04/2009
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
Port# : Port-1
28
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
A prompt will ask if you want to clear the performance data. Use the Tab key to select the port
you want to clear. Press Y for yes.
Unit 1 E3 === Performance Setup/Clear === 16:13:53 03/20/2008
>> Use TAB key to select port, and ENTER key to clear performance: All Ports
A prompt will ask “Are you sure?” Press Y for Yes
29
CHAPTER 4 E3/T3 SETUP PROCEDURE
The Unit Performance Threshold Setup screen will appear. Use the arrow keys to move the
cursor to each field. Use the Tab key to scroll in your settings. Press the Enter key.
A prompt will ask if you want to change the configuration. Press Y for Yes. In order to save
this configuration you must return to the O9500R Controller Menu and press V.
30
CHAPTER 4 E3/T3 SETUP PROCEDURE
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
31
CHAPTER 4 E3/T3 SETUP PROCEDURE
The Unit Download Firmware Setup screen will appear. Use the arrow keys to move the
cursor. Key in the TFTP Server IP address and the firmware file name. Press the Enter key.
Unit 1 E3 === Unit Download Firmware === 17:56:29 03/20/2008
ARROW KEYS: CURSOR MOVE, Please Input: nnn.nnn.nnn.nnn, BACKSPACE to edit
<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>
A prompt will ask if you really want to download. Press Y for yes.
Really want to Download ?
The Copy firmware to standby unit screen will appear. A prompt will ask if you are sure.
Press Y for yes. The copying will occur immediately.
Unit 1 E3 ===File Transfer=== 17:44:17 04/03/2008
32
CHAPTER 4 E3/T3 SETUP PROCEDURE
Note: You must set up a cross-connect map before the SNCP/UPSR APS Setup will function.
Cross-connect mapping instructions can be found in the user’s manual for O9500R
controller.
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR APS status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
33
CHAPTER 4 E3/T3 SETUP PROCEDURE
The SNCP/UPSR APS Command screen will appear. Use the arrow keys to move the cursor.
Key in the Port number. Use the Tab key to scroll in the Command setting. Press the Enter
key. A prompt will ask if you are sure. Press Y for yes.
Port : 1
Command : Clear
Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary
A prompt will appear on the screen to tell you that the command has been accepted.
APS Cmd Accepted!
The SNCP/UPSR Revertive Setup screen will appear. Use the arrow keys to move the cursor
to each field. Use the Tab key to scroll in your settings. Press the Enter key.
Port : 1
Revertive: Non-Revertive
34
CHAPTER 4 E3/T3 SETUP PROCEDURE
<< Press ESC key to return to Main Menu or enter a command >>
The SNCP/UPSR APS Command screen will appear. Use the arrow keys to move the cursor.
Key in the Port number. Scroll in the Channel #. Use the Tab key to scroll in the Command
setting. Press the Enter key. A prompt will ask if you are sure. Press Y for yes.
Another screen appears.
Command : Clear
Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary
A prompt will appear on the screen to tell you that the command has been accepted.
APS Cmd Accepted!
The SNCP/UPSR Revertive Setup screen will appear. Use the arrow keys to move the cursor
to each field. Use the Tab key to scroll in your settings. Press the Enter key.
35
CHAPTER 4 E3/T3 SETUP PROCEDURE
Port : 1
Channel : 01
Revertive: Non-Revertive
Success!!!
>>Are you sure (Y/N)?Y
36