Ultrasound Cavitation Multipolar RF Machine
Ultrasound Cavitation Multipolar RF Machine
Ultrasound Cavitation Multipolar RF Machine
User manual
Filter for water
Cavitation connector
Vacuum connector
Power switch
Catalogue
Introduction Treatment theory
1. Applications
2. Features
3. Parameters and specification
4. Taboo(forbidden to use )
Operation instructions
1. Cavitation explode
2. multipolar rf for dissolving fat cell on body
3. Tripolar RF skin tightening
4. Vacuum liposuction system
5. Lipo laser for cellulite . weight loss
Clinic experiece
1. Treatment course
2. Treatment of important notice
I. Introduction
Also we use 1 MHz radio frequency to alternate the electric field in the skin from positive to
negative. It will produce heat under dermis then the initial collagen denaturation. Subsequent
neocollagenesis then further tightens the dermal tissue and make the skin tightened, smooth
and fresh.
Tripolar RF energy is transmitted to the place between three electrodes; the current
permeates target tissue and generate heat. It will produce the equal and cycle energy between
three electrodes ,because of that .The patient will feel more comfortable during treatment , it
will get good result on skin lifting , tightening slack skin . wrinkle removal etc
Vacuum fat-liposuction system can promote tissue metabolism ,repel the cellulite .tighten
the flabby skin ,strengthen the skin elasticity etc,As It will bring the gas and vapour on the
between skin and treatment head, so it will give a positive pressure on liquid molecule through
the expansion cycle on body , The explosion effects inside and outside the cells will increase the
molecular movements .so as to achieve an high energy state .then make the lipocyte dissolving
quickly .it will give you slimming body ,Its effect will last for a long time . at the same time, it
can enhance the muscle elasticity and improve the cell metabolism .
Tripolar rf technology painlessly delivers focused and optimal RF energy to the skin surface
and to subcutaneous fat layers. Controlled energy is delivered via three or more electrodes ,
centered between them, and limited only to the treatment area. This focused delivery results
in improved treatment efficacy that provides immediate visible results from the first treatment.
The treatment is painless and pleasant because of the relatively low power needed.
The energy of tripolar rf permeates epidermis and take effect on the collagen-rich dermal
tissue directly which makes water molecules in the skin move. The move produces controllable
heat and results in contraction of collagen and generation of new collagen and dermal
remodeling .as a result, the skin looks tighter, wrinkle reduce gradually .
Tripolar rf integrated preset parameters allow operator to choose between body and facial
treatments. Targeted facial treatment regenerates collagen fibers in the dermis layer. Targeted
body treatments shrink fat cells in the hypodermis layer and accelerate collagen regeneration.
The most effective way to weight loss and body contouring without pain, needles and
down time
Low levels of diode laser energy emitted by LumiSlim stimulate the fat cell membranes,
changing their permeability. The cells lose their round shape, and intracellular fat is
released. Then the fatty triglycerides flow out of the disrupted cell membranes and into
the interstitial space, where they gradually pass through the body’s natural metabolic
functions with no harmful physiological effects, to be used as an energy source for the
body. This process does not alter neighboring structures such as the skin, blood
vessels, and peripheral nerves. It is not merely the liquefaction of fat but instead it is
the instant breakdown of the fat cells, otherwise known as lipolysis.
2. Applications
1) Ultrasonic cavitation head(cavitation explode) for burning fat cell , explode fat cell,surplus
fat ;
2) Multi polar RF(lipolysis RF) head for body shaping,slimming,fat burning ; fat &cellulite
reduction ;
3) Tri-polar RF head for skin tightening , skin lifting ,wrinkle removal on face and body with
big and small treatment head
4) Vacuum liposuction head for slimming ,remove surplus fat cell ;
5) Lipo laser for body slimming . weight loss
3. Features:
1. Simple and easy operation.
2. Adopt the newest lipo cavitation lipolysis and tripolar rf technology.
3. Use mult-handpieces for body &face treatment.totally 4 handpieces+8 paddles
4. Comfortable, painless, non-surgical with safe fast and effective result.
5. It don’t need recover time. immediate result will be seen after one session.
1. Main Machine X 1
2. Cavitation Handle X 1
3. tripolar rf handle X1
4. Multi-polar rf Handle X 1
5. vacuum handle
Package include
6. lipo laser paddles x 6 or 8
8. Protective Goggles X 2
9. English manual/instructions, CD
5. Taboo(forbidden to use )
1) Serious disease, such as heart disease, gastric ulcer, serious gastropathy,
duodenal ulcer, high blood pressure, diabetes
2) Pregnant women, lactating women, an abdominal operation within 3 months,
menstrual period, metal pieces in body (such as heart jumping devices etc)
3) Do not do treatment around testis
4) Food of High-calorie, High fat, and High protein, better to light food
5) Taking other diet medicine, we suggest that stop taking those diet medicines
and do ultrasonic treatment 1-2 months later; or prolong treatment period.
6) Can not do ultrasonic treatment under empty stomach, must be 1 hour later
dinning
This fat reduction system is high-tech medical beauty equipment with safety and reliability, mainly
for removing surplus fat, burning surplus fat, Lymphatic Treatment, skin tightening ,wrinkle removal and
improving skin elasticity. etc.
For the safe and effective use, operators and assistants must know below
It will generate the hot during ultrasonic cavitation and tri-polar RF operation,
The operator should ask the patient whether it is very hot or not on the treatment skin,
It is normal that the patient will feel a little hot with ultrasonic cavitation and tri-polar RF ,in fact the
patient will feel very comfortable for tripolar RF treatment .
Patients: The Safety of patients mainly rely on well-trained physicians as well as the layout of the
appropriate treatment room. Cultural quality of life of patients is also very important;
they should understand the principles of treatment. Patients should be protected
effectively when treatment.
Operators: The operator should ask the patient whether it is hot or not (a little not is normal ),
【MAIN ALARM】
1. Except the authorized mechanic, any others have no right to examine and repair theFG660
structure; especially inner structure inside of machine that including electrical source,RF system
,treatment head etc .
Notice the dangerous high pressure inside.
2. Make sure whether the voltage of the system is accordant with your local voltage or not.(220V/110V
AC)
3. Maintenance must be done after turning off the machine and drawing out the power line. Or it’s
most possible to hurt people and damage the equipment.
4. keep the treatment head clean after treatment ,
5. Don’t place treatment head, electrode cathode and patient’s heart in the same level
【Alarm】
i. The operator should pay more attention to the treatment situation during treatment
ii. Don’t make the tripolar and ultrasonic treatment head close to metal and conductor, treatment
head should be hung up when don’t use it ,
The treatment head should be point at treatment area when using it
【PREVENT FIRE】
1. The temperature will rise after absorbing wave energy, so please take actions to reduce the
flammable risk on treatment parts or around area.
2. Do not use ethanol, acetone or other flammable things on skin before treatment. If necessary,
please use soap or water.
3. When listerizing the treatment head or other parts by ethanol, please wait till dry.
【AUTOMATICALLY INSPECTION】
After turning on the machine, it will be inspecting automatically. About 1-3 minutes running
automatically, then it enters into the next step.
1. Put some cooling gel on the skin before treatment (such as: the abdomen, buttocks,
thighs) ,it is more convenient for the operator to move the treatment head easily .
2. Set working hours (about 10 to 15minutes), adjust the output intensity 1 to 2 level
(5w/cm²~ 25w/cm²)
3. touch "Start" button, the machine will automatically work.
4. Beautician grip the treatment head touch the skin closely ,and make slow circular
motion or a straight line go and back movement, don’t stop the treatment on the
same place
5. Can not operate in the back of body, we must avoid the bone bits
6. The machine will stop automatically after the setting time is over. You can also press
the stop to make the machine stop.
Choose lipo
laser and rf
can work
together
RF treatment
1. please put about 3mm cooling gel on the skin before operation , according to
different face or body teatement. choose big or small tripolar treatment head.
2. P for pulse time(pulse interval ) . D for continues working time (output energy time)
3. Touch “Start” , machine start to work.
4. The machine will stop automatically after the setting time is over.
5. clean skin and treatment head with hot towel.
2 . Place the big paddles on the parts which need to lose weight , place the small paddles on the lymph
parts of body where close the big paddles .
P for Pulse range from 0.2 to 5.0 Recommend parameter 4.0 to 5.0
D FOR Interval range from 0.2 to 5.0 Recommend parameter 0.2 to 1.0
For face lifting . wrinkle removal .please choose the small tripolar rf head for 5 to
10 minutes.
3. Clean the skin again, put some essential oil on the skin and massage the fat
body ,imporve the lymphatic drainage system and slimming care (about 5 to 10
minutes), It can also do breast enhance .
Cavitation explode : start with 2 W/CM2 treatment around 10 minutes for treatment
parts of the body
Tripolar RF : Start with 8 or 10 J/CM2 give a treatment around 5 minutes for treatment
parts of the face
multipolar rf : start with 16J give a treatment around 8 minutes for treatment parts of the
body
Ⅳ. Clinical experiece
Treament course
a. The energy must be started from low to high, or it may burn the skin.
b. Every treatment time must be less than two weeks
c. The patients should drink some water before treatment
d. During treatment, the patients should eat less, or they eat food which contains less fat and high kcal
e. Doing more exercise.
f.
Notes
1. please make sure of the enough coupling gel when you use cavitation explode ,
multi-polar rf
please keep it stop situation when you don’t use it . In case of the burnt broken
parts .
3. cavitation head against for a long time in one position without moving, forbidden to
stay in the
bone position.
4. please use the electrode patches when you only use the multi-polar rf .Please place
the electrode
patches on the back of patient first, make sure that it touch the skin tightly.
And then start the multi-polar rf treatment , don’t keep the multi-polar rf head leave
the skin during treatment .
If you want to leave the skin, you have to stop the machine first. and then leave the
monopolar
disease after treatment, and this is normal, it will recover a few days later.
I. Common problems
Solution:
1) Check tripolar wire, if it is connected well, the indicator light should be on.
2) open the handpiece and see whether it is connected
3. No ultrasonic cavitation output
1) Check ultrasonic wire, if it is connected, the indicator light should be on.
2) open the handpiece and see whether it is connected
4. No lipolgysis output
Contact us
We mainly produce tattoo removal ,laser hair removal, ; IPL photo rejuvenation; RF(monopolar, bipolar
,tripolar multi-polar radio frequency) ,e-light ,lipo laser. cryolipolysis machine . PDT skin care, ultrasonic
vacuum technology cellulite reduction,teeth whitening equipment etc , we also provide various kinds of
laser component etc.
we offer OEM service . we always offer best price with high quality product
Address : C/223, Ghatkopar Industrial Estate, Lal Bahadur Shastri Marg, Ghatkopar West, Amrut Nagar,
Mumbai, Maharashtra 400086
Skype : asad.haroon11