Hooseki Catalog
Hooseki Catalog
Hooseki Catalog
Catalog
HOOSEKI I
Addressable Fire Alarm Control Panel
Cabinet Wall-mount
Addressas
255/1L 510/2L 765/3L 1020/4L 1275/5L 1530/6L 1785/7L 2040/8L
/loops
01. HOOSEKI
Addressable Fire Alarm Control Panel
Specifications
Item Specifications
Model HS-ADD-P1/8L(1 Loop/8 Loop), HS-ADD-AN 1/8 ( 1 Loop/8 Loop)
Power Source 1 1OV AC 50/60 Hz or 220V AC 50/60 Hz
Addresses / Loops 255/ 1L 510/2L 765/3L 1020/4L 1275/5L 1530/6L 1785/7L 2040/8L
Standby Battery 24V DC
Transmission Distance Two-wires (able for branch wiring l,5km)
Annunciator Connection Use RS-485 for 800m, Network Signal Transceiver for 3km and Optical Fiber
for up to 40km
Loop Voltage Load Power / Indicating Lamp / Zone Telephone : 24V DC
SLC power source: 32V AC
Power Consumption Main control panel (monitoring} :500mA
Communication module for each system (monitoring) : 280 mA
Transmission Method Selective and sequential (I/0 modules)
Broadcast Output Relay output :interlock relay board x 13 sets for a max of 2,000 contacts
Method (relay board = 40 contacts [standard], 160 contacts [expansion])
Main Audio Voice notifications, human voice or voice alarm (over 90 dB)
Ambient Temperature 0~40°C
Cabinet Material Powder coating steel (optional Flame retardant ABS enclosure available
up to 255/1L only)
HOOSEKI 02.
Conventional Fire Alarm Control Panel
Cabinet Wall-mount
Number
5-10L 15L 20L 25-30L 35-40L 45-50L 55-60L 65-70L 75-80L 85-90L 95-100L 105-110 115-120L
of Loops
H(mm) 400 495 580 520 580 700 760 840 930 1020 1110 1195 1350
W(mm) 300 300 300 480 480 480 480 480 480 580 580 580 580
D(mm) 120 120 120 180 180 180 180 200 180 200 180 200 200
03. HOOSEKI
Conventional Fire Alarm Control Panel
Interlock
Cabinet Floor-standing 2-in-1 3-in-1 4-in-1
Control Panel
Number
125-130L 135-150L 155-170L 135-260L 265-300L 305-340L 345-450L 455-600L 1L 1L
of Loops
H(mm) 1600 1800 2000 1600 1800 2000 1800 1800 180 250
W(mm) 580 580 580 1160 1160 1160 1740 2320 180 210
HOOSEKI 04.
Fire Alarm System
Fire Alarm P.B.L Combination Series
This Fire Manual Station con quickly transmit a signal to the fire receiver terminals or the
repeaters while the button under a transparent protective cover has been pushed at the
first finding of a fire accident. (This signal is beyond the accumulated time limitation).
There is a light over the button. The light will light up as a signal has been exactly received
by the receiver terminal. There is also a telephone jock for telephone communication with
attendant at the fire receiver terminal.
Specifications Advantages
Option Base
Model No. HS-FPI 1. Auto-Return by pushing button, no need to disassemble
Material Fire-Proof
Voltage Range 24V DC the main body.
plastics
Alarm Current 30 mA 2. Response light available to identify the operation completed.
Dimensions O 140 (mm)
Contact Rating 24V DC 100mA 3. Reinforced transparent protective cover is reusable.
Weight 150g
Sub-Function Phone jack: 4. All plastics are fire-proof, light, convenient and stylish.
Color Red
Confirmation LED; 5. Outside cord distribution with terminators to ease on work.
Reset button
05. HOOSEKI
Fire Alarm System
Fire Alarm Accesories
BOX Main
Distribution Frame
HOOSEKI 06.
Fire Alarm System
I/O Modules
HS-ADD-BD
Base Detectors Addressable
(Only for full Addressable System)
Specifications
Functions
• Status indicators for Monitoring, Active, Error and Isolating. • Self-test functions for circuit disconnection and activation
• Address coding by binary coded dip switch for easier setting • Expandable to connect with photoelectric smoke, rate of rise heat
• Two-wires multi-transmission detector and fixed temperature heat detector, and no need for external
• Stable communication with rejection to noise and disturbances power supply
Wiring Notes
• Addressable Detector Base's L+ LC connect to Convensional • Provided current is not over 1.3mA/DC24V
Detectors' L+ LC, polarized • A Profesional terminal device is needed, cannot use a normal 10KΩ
07. HOOSEKI
Fire Alarm System
I/O Modules
HS-ADD-I/O-1
Control Modules 1 In 1 Out
(with isolation function) Communication isolation function,
when short circuit occurred in the module, the module will
be automatically isolated from the main communication line.
Specifications
SPECIFICATIONS
• EOL : Below ICON capacitor / address.
• EOL
Operating
: BelowEnvironment : 0°C-/ 50°C
10K Ω capacitor relative humidity below 85%
address. • Rated Voltage : 33V AC
MonitoringEnvironment
Current : 3.2: mA • Rated Voltage : 33V AC
• Operating °0 C- °50 C relative humidity below 85% • Output Contact Capacity : 30V DC / 2A (max)
Activating Current • Output Contact Capacity : 30V DC / 2A (YRR-3LO & YRR-4LO)
• Monitoring Current: :48mA
420 A • Material : Flame retardant plastic
64mA (YRR-4L & YRR-4LO) • Material : Flame retardant plastic
• Activating Current : 16mA • Dimensions : 80 (H) x 60 (W) x 30 (D) mm
• Load Voltage Input : 24V DC (YRR-3LO & YRR-4LO) • Dimensions : 87 (H) x 93.5 (W) x 43 (D) mm
• Note : EOL capacitor
• Note : EOL capacitor
HS-ADD-I/O-4
Control Modules 4 In 4 Out
Specifications
• EOL : Below 10K Ω capacitor / address.
• Operating Environment : 0°C- 50°C relative humidity below 85%
• Monitoring Current : 3.2 mA
• Activating Current : 48mA • Output Contact Capacity : 30V DC / 2A
• Activating Current : 64mA • Material : Flame retardant plastic
• Load Voltage Input : 24V DC • Dimensions : 87 (H) x 93.5 (W) x 43 (D) mm
• Rated Voltage : 33V AC • Note : EOL capacitor
HOOSEKI 08.
Fire Alarm System
Rate of Rise Heat Detector
Description
The rate-of-rise heat detector, HS-WS19L, is designed to sense the rapid When a slower temperature change occurs, the expanded
or abnormal rise in temperature of air. If ambient temperature rises air escapes through a bleeding hole to keep the pressure
rapidly, the air in chamber expands and presses the diaphram to close balanced so that the fault alarm never occurs.
the contact point to give advanced warning.
Advantages
• Rate-of-rise heat detector detects intense fires by quickly • Red indication lamp lights when detector is activated.
responding to rapid temperature increases. • High-temperature-enduring plastics and fire-proof material
• Mechanical operating principles ensure the long-term durability are used to build up the main body of the detector.
and the least malfunction. • The base is in common with other detectors made in this
• Self-restoring ensures those elements repeated use. company for the facilitation of installation.
• High quality components are fitted for greater reliability. • Connections are non-polarized to avoid wiring mistakes.
Specifications
09. HOOSEKI
Fire Alarm System
Fixed Temperature Heat Detector
HS-WK100L Description
ISO 9001 certificated CE The detector, HS-WKIOOL incorportes a self-resetting bimetallic disk
element with response indicator. It activates whenever the ambient air
temperature reaches the top temperature detector setting.
Advantages
• Stabilized performance, long-term durability and least- • Red indication lamp lights when detector is activated.
malfunction are ensured by employing a bimetal mechanism. • High-temperature-enduring plastics are used to build up the
• Self-restoring ensures the elements repeated use. main body which is also nicely shaped.
• The sensitive part is enclosed to prevent from being • The base is in common with other detectors made in this
moistened and contaminated. company for the facilitation of installation.
• Pure silver contacts ensure the quick response. • Connections are non-polarized to avoid wiring mistakes.
Specifications
HOOSEKI 10.
Fire Alarm System
Photoelectric Type Smoke Detector HS-WT3OL
HS-WT30L
Specifications
Description
This is an advance scientific device. It is very quick and
The photoelectric type smoke detector is based on the photoelectric
accurate to activate the early fire warning system.
sensing principle to make up. When fire break out and smoke enters the
Because of the pretty and compact styling, it is most
light- tight box, the particles of smoke scatter the infrared light, and
suitable for the interior decoration of the modern
this scattered light goes into the receiving element, thereby emitting
buildings.
an electric current, and while the electric current is up to the fixed
extend, the fire alarm will be activated.
11. HOOSEKI
ISO 9001, APPROVED