Hydro-Gloss: Technical Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TECHNICAL DATA SHEET

HYDRO-GLOSS
Hydro-Gloss is an environmental friendly green product with low VOC (Volatile Organic Compound)
for interior and exterior use. It is formulated with a solvent-free resin to limit air pollutants and has
low odour during application and drying. Being a green product, it is ideal for use in eco-sensitive
an extremely commercial and residential areas such as hospitals, schools, residential buildings and
hotels. It is easy to apply and forms a tough paint film with durability and smooth finishing.

Product Features:
Environmental-friendly green paint for wood and metal substrate
Low VOC
Easy application
Fungus resistance
Excellent coverage and hiding power

Paint Type Product Finishing Recommended Substrate Pack Size


Type
Water based Interior & High Gloss Wood, Metal and Concrete 0.91Ltr, 3.64Ltr
Exterior
Composition
Pigment : Mainly Titanium Dioxide, Iron Oxide, Carbon Black, Organic Pigments
Binder : Ambient Cross-linking Acrylic Polymer
Thinner : Water

Technical Data
Drying Time : Touch Dry : 30 minutes (Dependent on temperature and humidity)
: Hard Dry : 1 hour (Dependent on temperature and humidity)
Recoating Time : 2 – 3 hours (Dependent on temperature and humidity)
Dry Film Thickness : 30 – 40 µm per coat (based on substrate condition)
No. of Coats : 2 – 3 coats
Theoretical Coverage : 9 – 11 m2 per litre per coat (Actual coverage is dependent on substrate condition, application
method, application condition and finishing appearance).
Volume Solid : ~ 40%
Shelf Life : Up to 18 months in tight sealed container

Application Method
: Dilute the paint with not more than 5% of water. Preferable not dilute for best performance. For
Brush / Roller/ better finishing, it is advisable to apply using roller application followed by trimming with Brush if
Spray (conventional) application on walls/plain surface.

Recommended Coating System

Walls , Concrete & Wood


Sealer / Primer : Vinilex 5100 : 1 coat
Top Coat : Hydro-Gloss : 2 -3 coats

Metal
Sealer / Primer : Hydro-Primer : 1 Coat

Top Coat : Hydro-Gloss : 2 – 3 Coats


TECHNICAL DATA SHEET
Surface Preparation

Bare Masonry
Bare masonry surfaces should be completely dry and free from dust, dirt and grease. Use a Bleach solution to treat the
surface affected by fungus. Apply NIPPON VINILEX 5100 WALL SEALER and allow thorough drying. Sand and dust off.
Smoothen the surface by applying 2-3 coats of NIPPON ACS PUTTY. Sand and dust off thoroughly. Allow all surfaces to dry
completely prior to painting. Avoid painting when the moisture content and alkalinity of the walls is still high.
(Recommended painting specification requires the moisture content of the walls to be below 16% measured by protimeter
and alkalinity of the walls to be below pH9.)

 Previously Painted Sound Surfaces

Remove unstable paint film, loose chalk by rubbing down using abrasive paper or wire brush and dust off. Prime with
NIPPON VINILEX 5100 WALL SEALER. Fill the surface with NIPPON ACS PUTTY if necessary.

Wood
Wood must be dry and free from dirt, grease and other contaminants. Smoothen surface with sand paper, then clean off
and dry.

Metal
Surface must be dry and free from dirt, grease and other contaminants. Ferrous substrate should be sanded or wire-
brushed to remove millscales and rust. Clean off dust and dry.

Scrap off any loose and flaking paint film. Sand and smoothen defective areas. The entire surface must be dry and free
from dirt, grease and other contaminants. For the case of ferrous substrates, remove rust thoroughly. The scraped areas
should be spot-primed. Light sanding on surface would ensure better subsequent intercoat adhesion.

Cleaning
Clean up equipment with water immediately after use.

Safety Precautions
Keep container tightly closed and keep out of reach children or away from food and
drink. Ensure good Ventilation during application and drying.
When applying paint, it is advisable to wear eye protection.
In case of contact with eye, rinse with plenty of water immediately and seek medical advice.
Remove splashes from skin by using soap or water.
Paint must always be stored in a cool place.
When transporting paint, care must be taken. Always keep container in a secure upright position.
Dispose any paint waste in accordance with the appropriate Environment Quality Regulations.

Note
* Theoretical Coverage is based on a mathematical formula and does not consider LOSS FASTORS.

Volume Solid% x 10
Dry Film Thickness = m2 /lit/coat
[

Variables like porosity of substrate, application method, dilution ratio, dry film thickness, opacity and so on will affect the
loss factor and can vary from 30% - 50% or even more. The above information is given to the best of our knowledge based
on laboratory tests and practical experience. However, since we cannot anticipate or control the many conditions under
which our products may be used, we can only guarantee the quality of the product itself. We reserve the right to alter the
given without prior notice.