0% found this document useful (0 votes)
493 views29 pages

Readme B

Uploaded by

danny
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
493 views29 pages

Readme B

Uploaded by

danny
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 29

SICAM SCC V9.

03 2018-12
Readme

Readme for SICAM SCC V9.03

1 Compatibility .................................................................................................. 3
2 Converting Projects from Former Versions ................................................. 3
3 General Restrictions ...................................................................................... 4
3.1 SICAM Wizards ................................................................................................ 4
3.1.1 SICAM IEC Wizard ........................................................................................... 4
3.1.2 SICAM TEA-X Wizard ...................................................................................... 4
3.2 SICAM Network Manager ................................................................................. 5
3.3 SIMATIC WinCC Web Navigator ...................................................................... 5
3.3.1 Display of Switching Objects up to SICAM SCC V7.02 with own Pictures ........ 5
3.4 Topology .......................................................................................................... 5
3.5 Topology with SIMATIC WinCC V7.4 SP1 and V7.5......................................... 5
3.6 Dynamic Alarm Filter ........................................................................................ 5
3.6.1 DAF – Configuration of Alarm System .............................................................. 5
3.7 SICAM Switching Device Objects V8.0 and later .............................................. 6
3.7.1 Touch Operation .............................................................................................. 6
3.7.2 Displaying Switching Objects with own Pictures ............................................... 6
3.8 SICAM IndustrialX Controls up to V7.02 ........................................................... 6
3.8.1 Displaying Switching Objects with own Pictures ............................................... 7
3.8.2 SICAM SCC LS/TR IndustrialX Control ............................................................ 7
3.8.3 SICAM WinCC V3 IndustrialX Control .............................................................. 7
3.9 IEC Communication Suite ................................................................................ 7
3.9.1 IEC Communication Suite – Buffered Report with IEC 61850........................... 7
3.9.2 IEC Communication Suite – Connection of IEC 60870-5-104 Devices ............. 7
3.10 Connection to SICAM PAS from SICAM PAS V7 ............................................. 7
3.10.1 Redundant SICAM PAS .............................................................................. 7
3.11 Connection to SICAM PAS of Earlier Versions ................................................. 8
3.11.1 SICAM PAS Channels of Earlier Versions ................................................... 8
3.11.2 Normalization DLL....................................................................................... 8
3.12 SICAM Valpro .................................................................................................. 8
3.13 WinCC Report Designer ................................................................................... 8
3.13.1 WinCC Alarm Log with Line Printer ............................................................. 8
3.13.2 WinCC Message Sequence Report with Page Printer ................................. 9
4 Changes Compared to Previous Version ................................................... 10
5 Revision History ........................................................................................... 11
5.1 SICAM SCC V9.02 Compared to SICAM SCC V9.01 ..................................... 11
5.2 SICAM SCC V9.01 Compared to SICAM SCC V9.00 ..................................... 12
5.3 SICAM SCC V9.00 Compared to SICAM SCC V8.04 ..................................... 12
5.4 SICAM SCC V8.04 Compared to SICAM SCC V8.03 ..................................... 14
5.5 SICAM SCC V8.03 Compared to SICAM SCC V8.02 ..................................... 15
5.6 SICAM SCC V8.02 Compared to SICAM PAS CC V8.01 ............................... 15
5.7 SICAM SCC V8.01 Compared to SICAM PAS CC V8.00 ............................... 16
5.8 SICAM SCC V8.00 Compared to SICAM PAS CC V7.02 ............................... 17
5.9 SICAM SCC V7.02 Compared to SICAM PAS CC V7.01 ............................... 18
5.10 SICAM SCC V7.01 Compared to SICAM PAS CCV7.00 SP1 ........................ 20
5.11 SICAM PAS CC V7.00 SP1 Compared to V7.00 ............................................ 22

Unrestricted – Siemens Aktiengesellschaft Page 1 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

5.12 SICAM PAS CC V7.00 Compared to the V6.0x Versions ............................... 24


5.13 SICAM PAS CC V6.0x Versions Compared to V5.11 ..................................... 25
6 Open Source Software Used in the Product............................................... 29
7 Contact.......................................................................................................... 29

Unrestricted – Siemens Aktiengesellschaft Page 2 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

1 Compatibility
The licenses for SICAM PAS CC V6.x, V7.x, and V8.0x continue to be valid for SICAM SCC
V9.0x, but they are not compatible with the authorizations of SICAM PAS CC V5 versions.
There is an upgrade license available for former V5 authorizations.

SIMATIC WinCC V7.3 (V7.3 Second Edition) must be installed with at least Update 16.

SIMATIC WinCC V7.4 must be installed with at least SP1 Update 4 and Patch 4/Update 5.
SIMATIC WinCC V7.4 without SP1 cannot be used.

SIMATIC WinCC V7.5 must be installed with at least Update 1.


Until Update 1 is available, the following restrictions apply:
- The monitoring of the compatibility key between SICAM PAS and SICAM SCC only
monitors the last imported SICAM PAS station.
- Acknowledge of the horn only takes effect after acknowledging the GO message.

Detailed references regarding SIMATIC WinCC and SIMATIC software can be found in the
WinCC Information System in Installation Requirements and on the following support websites:

Industrial Security Alerts


Information on security patches and security updates:
● http://www.industry.siemens.com/topics/global/en/industrial-security/news-alerts/

Microsoft Windows Patches/Updates: Compatibility with SIMATIC Products


Note the latest information on compatibility of SIMATIC products with Microsoft patches and
updates:
● FAQ 18752994 (https://support.industry.siemens.com/cs/ww/en/view/18752994/)

The required hotfixes/updates for SIMATIC WinCC are available on the SICAM SCC DVD.
Check whether a new hotfix/update for an installed component is available on the DVD.

In order to be able to run both SICAM SCC and DIGSI 4 on the same computer, install DIGSI
first and then SICAM SCC. Uninstalling just one product is not recommended.

NOTE
After the installation of SICAM SCC, if you install or uninstall SICAM PAS/PQS V8.03 or earlier
or SICAM PQ Analyzer V3.03 or earlier on the same computer, you must repair the SICAM
SCC installation.
To do so, use the functionality provided by the Windows Control Panel.

2 Converting Projects from Former Versions


Observe the configuration notes in chapter 13 of the manual.

NOTE
The SICAM PAS Protocol Suite V7 is no longer included. Change your SICAM SCC projects to
the SICAM PAS Protocol Suite standard channel before updating the software.

Unrestricted – Siemens Aktiengesellschaft Page 3 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

3 General Restrictions
NOTE
If you migrate a SIMATIC WinCC project or use the OS project editor, deactivate the SICAM
Add-in in Graphics Designer’s Addin-Manager before.
When the Graphics Designer is opened, the SICAM Add-in takes a few seconds. Since the
Graphics Designer gets frequently opened and closed in the background during these
operations, an activated SICAM Add-in could cause delays or abortion of the operations.

3.1 SICAM Wizards


Using the PAS or IEC Wizard is only possible in projects which have not been configured before
via TEA-X Wizard or SICAM Network Manager.
If you want to configure the PAS or IEC connections, you have to pass through the SICAM PAS
or IEC Wizard with the option Create SICAM components in project without import data
before using TEA-X Wizard or SICAM Network Manager.
After this initialization all Wizards and the Network Manager can be used.

If you use Windows 2008 Server SP2 32 Bit, there may be sporadic problems with the WinCC
Project Manager when deleting all imported data of a station/a project. Errors during the
deletion are indicated in the Trace Window. Errors occurring during deletion are reported in the
Report window, and the WinCC Project Manager closes. In this case, create a WinCC Project
and copy the diagrams and other components into the new project.

If you switch the runtime language in SIMATIC WinCC, you have to close and re-open the
WinCC project before import/update, in order to get the texts of the import data for the Alarm
Logging System to be written into the text library in the correct language. When updating a
station, the same runtime language must always be used as with the first import.

NOTE
When importing data, observe the maximum number of tags that you have licensed for
SIMATIC WinCC. In SICAM systems every data structure is numbered as a tag.

If the maximum number of your licensed tags is exceeded, no further external tags are created
by WinCC. However, the internal parts of the tag structures are created. If this problem
occurred you have to delete all imported data of the project with the Wizard and then delete the
remaining external structure tags and internal single tags (*.RTInfo, *.RTCmd, *.RTSync, and
*.IXHook).
After installing a license for the required number of tags (the “smaller” license has to be deleted!)
or removing tags from the mapping to SICAM SCC, you can do a re-import.

3.1.1 SICAM IEC Wizard


When importing SXD files with the communication protocol IEC 60870-5-104 from the SICAM
TOOLBOX II, the entry [DEFAULT] in the GW1703.ini file (in the WinCC project under
\GWData\<Stationsname>\ComConfig\str) is wrongly inserted as [Default]. This causes the
communication driver to ignore this block. Change this entry to [DEFAULT] manually.

3.1.2 SICAM TEA-X Wizard


Using the TEA-X Wizard is now also possible in projects which had been configured before with
one of the other Wizards.
With the TEA-X Wizard several stations (import data-sets) can be imported and updated now.

Close the WinCC Configuration Studio before importing data with the TEA-X Wizard to avoid
access contentions.

Unrestricted – Siemens Aktiengesellschaft Page 4 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

3.2 SICAM Network Manager


The SICAM Network Manager uses the TEA-X Wizard for creating the data in the WinCC
project. When you create an SNMP station with a new project, you cannot use the SICAM PAS
or IEC Wizard for import afterwards.

If you want to configure PAS or IEC connections later, you can, for example, pass through the
SICAM PAS Wizard with the option Create SICAM components in project without import data
before starting the SICAM Network Manager.
After this initialization all Wizards and the Network Manager can be used.

For redundant SICAM SCC systems, each server enters messages in the message lists.
Because of the Online synchronization for Alarm Logging of the WinCC redundancy, you
then see these messages twice.

3.3 SIMATIC WinCC Web Navigator


For running this SICAM plugin the Visual C++ Redistributable Packages 2013 are required. The
setup is contained on the SICAM SCC DVD
(..\SetupData\InstallationData\Prerequisites\vcredist_x86_2013.exe).

After installation of the plugin, the SCCCommon.dll file has to be registered on the Web
Navigator Client. To do so, execute the SCCCommon.bat file with administrator rights in the
Program Files (x86)\Common Files\Siemens\Bin folder.

The PQ Analyzer cannot be called from the WebNavigator Client.

3.3.1 Display of Switching Objects up to SICAM SCC V7.02 with own Pictures
If user-specific bitmaps, configured without absolute path in SICAM SCC up to V7.02, are used
for display within the switching objects, these are not displayed during runtime in WinCC V7.2
or higher. The default search path is relative to the folder Program Files (x86)\Siemens\WinCC\
WebNavigator\Client\bin. You can reference the used bitmaps using this path or store them in
this location.

3.4 Topology
To be able to use the new Topological Coloring of V9.00 or higher, you have to adjust the
existing configurations. Consider the notes regarding conversion in the manual.
The previous Topological Coloring is not supported anymore.

3.5 Topology with SIMATIC WinCC V7.4 SP1 and V7.5


If you use pictures from previous WinCC versions, or library objects, check the connections to
other objects. The connections might get lost when inserting, converting, or copying picture
areas. In this case, re-connect the connectors with the switching and bay overview objects.

3.6 Dynamic Alarm Filter

3.6.1 DAF – Configuration of Alarm System


Notes on configuring the Alarm System when using DAF:
- In the WinCC Graphics Designer, from Project Library > Alarm Logging templates
import a SICAM SCC Alarm list for DAF into a Graphics Designer picture.
- To activate flashing in the message lists, change the following properties:
o In the Alarm list for DAF, open the properties of the WinCC AlarmControl and
go to the Message Blocks tab.
For each message block select the Flashing on option to activate flashing.
o Open the properties of the message blocks in the Alarm Logging and select the
Flash option for each message block to activate flashing.

Unrestricted – Siemens Aktiengesellschaft Page 5 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

o Open the properties of the message types in the Alarm Logging and select the
Flashing on option to activate flashing.

It is possible to display the user name in the message lists during runtime, when the
DAF is used. When a message is entered into to the message list the content of the
variable DAF_Username is written into the User Name DAF column.

Write the current user name, e.g. while sending a command, into the variable
DAF_UserName. The variable can be found in the tag management within the internal
tags folder in the SICAMDAF group.
In the Graphics Designer open a picture with a SICAM SCC message list for DAF.
In the Message lists tab of the WinCC AlarmControl properties you can now add the
User Name DAF from the available message blocks to the message list.

If you use the DAF_Username for messages that have to be acknowledged, consider
the corresponding configuration information. This allows you to configure an operation
message as acknowledgment message, containing the user who was logged on during
acknowledgment.

Messages which are displayed colored in the event list are displayed with GO color for
both COME and GO state.

3.7 SICAM Switching Device Objects V8.0 and later


Displaying user-defined texts in the window of a runtime dialog via UserStringID property is not
possible in the current version.

3.7.1 Touch Operation


The touch functionality is not supported by SICAM SCC with SIMATIC WinCC earlier than
V7.4 SP1.

NOTE
To be able to operate left and right mouse buttons via touch screen for SICAM switching objects
in older WinCC versions, place a transparent button on top of the SICAM switch and call the
same object functions for the button events Mouse Click and Press Right as provided in the
SICAM switch for OnLeftClick and OnRightClick.
However, in the VB Script of the button you have to hand over the name of the object. For
example, item.ShowSwitchDialog becomes Screenitems("<objectname of SICAM
switch>").ShowSwitchDialog.

3.7.2 Displaying Switching Objects with own Pictures


The controls delivered with SICAM SCC up to V7.02 have been optimized to considerably
increase the amount of displayable objects and to reduce the display times. If the switching
objects are displayed with pictures, these have to be newly configured within the switching
objects.

3.8 SICAM IndustrialX Controls up to V7.02


The number of objects that can be active at the same time within a WinCC project (server plus
all clients) is limited. This is because all IndustrialX objects register their variables separately to
WinCC. Additionally, the limit depends on the configuration; on standard systems, approx. 1500
to 1800 objects are possible.

Click OK to confirm your selection of process tags in the tag-selection dialog. A double-click
would only open an empty field.

Unrestricted – Siemens Aktiengesellschaft Page 6 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

The graphic objects


• LS/TR with CScript
• LS/TR with CScript, SBO and QoC
do not support command cancelation between Select and Switching command. Thus, the
time-out for the Select command in the device has to expire before a new switching is possible.
Alternatively, the cancel command can be sent via a separate button.

3.8.1 Displaying Switching Objects with own Pictures


If user-specific bitmaps, configured without absolute path, are used for display within the
switching objects, these are not displayed during runtime in WinCC V7.4 and higher. The
default search path is relative to the folder Programs (x86)\Siemens\WinCC\bin. You can
reference the used bitmaps using this path or store them in this location.

3.8.2 SICAM SCC LS/TR IndustrialX Control


For Version V7.02 or earlier, the switching objects cannot be used with the script control of the
command sequence (LS/TR with CScript) in the case of connection to SICAM PAS and when
using the Select before Operate (SBO) and Synchronisation with ILSA protocol functions.
With these switching objects up to SICAM SCC V7.02, when using Select before Operate and
Synchronisation with ILSA protocol only internal, but no user-defined dialogs can be used.

For the connection via the IEC Communication Suite the LS/TR object with CScript, SBO and
QoC is available in the library. This object supports the output via CScript.

3.8.3 SICAM WinCC V3 IndustrialX Control


The IndustrialX controls of SICAM WinCC V3 (SICAM Switching_Device1.ocx and SICAM
Switching_Device2.ocx) cannot be used anymore. They are displayed by the Graphics
Designer and can be migrated to suitable SICAM SAS objects via a pre-defined task from the
SICAM toolbar.

3.9 IEC Communication Suite

3.9.1 IEC Communication Suite – Buffered Report with IEC 61850

With redundant SICAM SCC systems, double entries may occur in the message lists if the
IEC 61850 devices operate with Buffered Report.
This behavior especially occurs after connection interruptions or after restart of the SCC
Runtime on one of the redundant SCC systems.

3.9.2 IEC Communication Suite – Connection of IEC 60870-5-104 Devices


Process time stamps are required in local time on the IEC 60870-5-104 connection of the
IEC Communication Suite. The devices have to be set to local time.
If the devices are connected via a SICAM RTU, the RTU converts the time stamps into local
time. In this configuration, the devices can send the time stamps in UTC.

3.10 Connection to SICAM PAS from SICAM PAS V7

3.10.1 Redundant SICAM PAS


At redundancy switchover at a SICAM PAS system running commands are cancelled after the
switchover (e.g. an active select). The negative command feedbacks which are sent thereby
are not indicated in SICAM SCC, in case a positive feedback came before. The SICAM SCC
switching devices hence show the command as active. Therefore the next command to this
address will be refused. A repeated command output will work as expected.

Unrestricted – Siemens Aktiengesellschaft Page 7 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

3.11 Connection to SICAM PAS of Earlier Versions

3.11.1 SICAM PAS Channels of Earlier Versions


NOTE
The SICAM PAS Protocol Suite V7 is no longer included. Change your SICAM SCC projects to
the SICAM PAS Protocol Suite standard channel before updating the software.

The channels of earlier SICAM PAS CC/SCC versions do not support the current switching
device objects introduced with SICAM SCC V8.00 and the SICAM SCC Runtime Data Server.

If you use one of the V5, V6 or V7 SICAM PAS channels included in the scope of delivery in
order to set up a connection to SICAM PAS, you use the V7.x IndustrialX switching device
objects which are also available in the Graphic Objects Library.
The channels of earlier versions do not provide the additional process data required for the
SICAM SCC Runtime Data Server. For this reason its functions are not available for tags from
these channels (e.g. spontaneous blinking).

3.11.2 Normalization DLL


If you connect a SICAM PAS V5 or V6 to SICAM SCC via one of the V5 or V6 SICAM PAS
channels included in the scope of delivery, instabilities may occur in the WinCC AlarmLogging
Runtime. To prevent this, in the Alarm Logging editor of the WinCC Configuration Studio
connect the PAS V5 or V6 messages with the PasNormV6.nll Normalization DLL from SICAM
PAS V6.

After changing the ProjectID resp. HMIInterfaceID (e.g. when creating a redundant project)
these settings have to be redone.

3.12 SICAM Valpro


For WinCC Clients with own projects, SICAM Valpro cannot access the Tag Logging Archives
of the WinCC servers.

3.13 WinCC Report Designer

3.13.1 WinCC Alarm Log with Line Printer

If necessary, the print layout for a line printer (SICAM_SIGNALLIST_LINEPRINTER.RP1) must


be adjusted to meet specific requirements of individual printers (regarding the number of
columns and lines).
Be aware to specify a font and margin settings suitable for your printer to ensure that at least
120 characters can be represented per line.

The line printer must be connected to a parallel printer interface.

When following the instructions of the SICAM PAS Wizard, the layout of the SICAM line printer
is copied into the project directory using the Create SICAM Alarm Logging System option.
When installing a new version of SICAM SCC, the sicam_signallist_lineprinter.rp1 file must
be copied from the ”..\WinCC\Syslay” directory into the ”..\<Projectname>\prt” directory.

Unrestricted – Siemens Aktiengesellschaft Page 8 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

3.13.2 WinCC Message Sequence Report with Page Printer


With some printer drivers, individual columns of the alarm log may be shown too small and
some characters are cut. In this case, it is possible to adjust the column width manually to
match the corresponding page layout. To do this, open the Properties dialog of the dynamic
table. Under Geometry, double-click the Columns property. In the next dialog that opens, you
can define the column width.

When opening the Report Designer for the first time, the SICAM layouts are copied into the
project directory. When installing a new version of SICAM SCC, the following files must be
copied from the ”..\WinCC\Syslay” directory into the ”..\<Projectname>\prt” directory:
• @sicam_signallist_pageprinter.rpl
• @sicam_signallist_pageprinter_land.rpl
• @sicam_short_term_pageprinter.rpl
• @sicam_short_term_pageprinter_land.rpl

Unrestricted – Siemens Aktiengesellschaft Page 9 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

4 Changes Compared to Previous Version


General Information
• SIMATIC WinCC V7.2 and V7.4 (without SP1) are not supported anymore.
• SIMATIC WinCC V7.5 is supported now.
• All files installed with SICAM SCC V9.03 are now digitally signed.
• The demo project has been updated (SIMATIC WinCC Audit example).

SICAM Network Manager


• New function: SICAM Network Manager
• The Simple Network Management Protocol (SNMP) versions V1, V2, and V3 (Secure) are
supported.

SICAM TEA-X Wizard


• SICAM PAS configuration files can now be exported in TEA-X format, too.
• It is possible now to import several stations as several TEA-X files.
• The TEA-X Wizard can also be used if another Wizard has been used for import in the
project before.

Unrestricted – Siemens Aktiengesellschaft Page 10 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

5 Revision History
5.1 SICAM SCC V9.02 Compared to SICAM SCC V9.01
General Information
• SIMATIC WinCC V7.4 is not supported anymore.

SICAM Message Management System


• New function SICAM Dynamic Alarm Filter (DAF)
• The Dynamic Alarm Filter (DAF) allows you to decide which – and how – status changes of
a message or an analog value are written into the SICAM SCC message lists or into a
trigger variable.

SICAM Switching Objects


• Bug fixing:
• Topological coloring for substituted switching devices
• Behavior of flashing

SICAM Measured Value Objects


• Additional event OnProcDataChange. Use topical objects from the graphics library.

SICAM Graphic Objects Library


• There are message-list templates for projects with and without DAF usage. If you use a
DAF configuration, update the message lists in the pictures.
• Revised SICAM measured value objects

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

SICAM Functions
• The SICAM SCC\Misc folder contains the new CScript SCC_CopyTagValueRT.fct.

SICAM TOOLBOX II
• Extended acquisition of communication parameters from the OPM into the initializing files
of IEC 61850 and IEC 60870-5-104 connections

SICAM IEC Channel – IEC 60870-5-104


• Saving process values in the IEC values and status file is supported.

SICAM IEC Channel – IEC 61850


• Saving process values in the IEC values and status file is supported.

Unrestricted – Siemens Aktiengesellschaft Page 11 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

5.2 SICAM SCC V9.01 Compared to SICAM SCC V9.00


General Information
• SIMATIC WinCC V7.4 SP1 is supported
• Operating system Windows Server 2016 is supported additionally

SICAM Switching Objects


• Revised CScripts for command output. Use topical objects from the graphics library.

SICAM Measured Value Objects


• Extended scripts for setpoint output with ‚Qualifier of Command‘ QoC. Use topical objects
from the graphics library.

SICAM Graphic Objects Library


• Revised SICAM switching objects and SICAM measured-value objects.

SICAM Web Navigator Plug-ins


• Updated Web Navigator Plug-ins for all supported SIMATIC WinCC versions

SICAM Functions
• The SICAM SCC\Command folder contains new CScripts for output of analog setpoints
with QoC; the other CScripts have been revised. Use these for new projects.

SICAM TOOLBOX II
• Extended acquisition of communication parameters from the OPM into the initializing files
of IEC 61850 and IEC 60870-5-104 connections.

SICAM IEC Channel – IEC 60870-5-104


• The trace output for the IEC 60870-5-104 connection is now deactivated by default.

5.3 SICAM SCC V9.00 Compared to SICAM SCC V8.04


General Information
• SIMATIC WinCC V7.4 is supported
• Operating system Windows 10 is supported additionally
• The Demo project has been updated (WinCC V7.4 and Topological Coloring)

Topological Coloring
• New topology components implemented
• A license key is needed for topological coloring
• New topology toolbar
• Consider the notes regarding conversion in the manual

SICAM Addin – Topological Coloring


• New dialogs for topological coloring
• Consider the new approach for creating topological coloring in the manual

Unrestricted – Siemens Aktiengesellschaft Page 12 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Addin – Configuration Support


• Updated pre-defined tasks and enhanced description

SICAM Switching Objects


• Picture format EMF supported again

SICAM Graphic Objects Library


• New structure, easier finding of graphic objects

SICAM Web Navigator Plug-ins


• Updated Web Navigator Plug-ins for all supported SIMATIC WinCC versions

SICAM Functions
• Under the project functions in the C editor of the Global Scripts a new folder has been
added containing revised CScripts. Use these for new projects.

Unrestricted – Siemens Aktiengesellschaft Page 13 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

5.4 SICAM SCC V8.04 Compared to SICAM SCC V8.03

General Information
• Extended Demo project (e.g. zoom and navigation window)
• Template project for micro grids

SICAM IEC Channel – IEC 60870-5-104


• The IEC 60870-5-104 connection can now be configured during runtime. Consider the
prerequisites mentioned in the manual.
• An Excel add-in is available to configure the IEC 60870-5-104 communication for direct
connection of devices to SICAM SCC.
The add-in generates XML files in DIGSI export file format and can be used for devices that
rd
do not provide import files (SXD, Digsi-XML), e.g. SICAM RTUs or 3 -party devices.
The Excel add-in can be used with 32-bit Microsoft Office in all approved operating
systems.

SICAM IEC Channel – IEC 61850


• Faster startup when using a bigger amount of devices
• When connecting SIPROTEC 5 devices via IEC 61850 direct connection, process values
can now be substituted on the devices.
• Adoption of static reports from the SCL file into the driver configuration
• Various compatibility expansions with SIPROTEC 5 V7 (support of SettingGroups,
SetValue)

SICAM PAS Normalization DLL


• The process-value message blocks used by the Normalization DLL for the SICAM PAS
connection can now be freely configured. This simplifies the integration of SICAM SCC into
existing SIMATIC WinCC or PCS7 projects.

SICAM Alarm Logging


• The user message blocks used for importing SICAM PAS messages can now be freely
configured. This simplifies the integration of SICAM SCC into existing SIMATIC WinCC or
PCS7 projects.

SICAM Web Navigator Plug-ins


• Updated Web Navigator Plug-ins for all supported SIMATIC WinCC versions

SICAM Wizards
• New Wizard for import of TEA-X files from SICAM PAS (no Unicode support).
If a TEA-X file is imported from SICAM PAS, only 1 SICAM PAS station can be connected.
To connect several SICAM PAS stations to a SICAM SCC, in SICAM PAS – Configuration
set the text format to Short text and the file type for export to PXD.

SICAM Addin – Topological Coloring


• In the SICAM Addin, an additional color can be selected which is displayed for a connection
from voltage to ground.
• The lines can be configured according to the line types provided by WinCC (continuous,
dotted).

Unrestricted – Siemens Aktiengesellschaft Page 14 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

• When generating the topological coloring, for all SICAM controls the SICAM Addin sets the
topological colors and line types that had been configured.

SICAM Functions
New function for message-specific acknowledgment of alarms

5.5 SICAM SCC V8.03 Compared to SICAM SCC V8.02


General Information
• Support of SIMATIC WinCC V7.3
• Additional support of operating systems Windows 8.1 and Windows Server 2012 R2
• For IEC61850 tools, e.g. SysCon, client ICD files are included for SICAM SCC on the DVD
(folder: ProductEnhancements\IEC61850).

SICAM IEC Channel


• IEC 61850 and IEC 60870-5-104 connections can now communicate over several network
interface cards.

SICAM PAS Channels


• The SICAM PAS Protocol Suite V7 is no longer included. If this channel has been used in
your projects, change your SICAM SCC projects to the SICAM PAS Protocol Suite
standard channel before updating the software.

SICAM Normalization DLL


• Change to trace concept of the channels

SICAM Graphic Objects Library


• New message list templates with toolbar extension for calling the PQ Analyzer
• Pre-configured buttons for calling the PQ Analyzer

SICAM Web Navigator Plug-ins


• Updated Web Navigator Plug-ins for all supported SIMATIC WinCC versions

SICAM Wizards
• Import of DIGSI export files (XML format) for devices with IEC 60870-5-104 communication
for direct connection of the devices to SICAM SCC
• During IEC 61850 import of SCL files, only a selection of information mapped in static
datasets is offered for devices which only support static datasets.
For devices supporting both dynamic and static datasets, these can be selected.

SICAM SCC Setup


• Installation via command line is possible, for automated installations (e.g. in training
centers)

5.6 SICAM SCC V8.02 Compared to SICAM PAS CC V8.01


General Information
• Dialogs optimized for touchscreen operation

Unrestricted – Siemens Aktiengesellschaft Page 15 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Add-In
• Accelerated creation of the scripts for topological coloring
• Function for replacing measured-value objects with SICAM Numeric Controls

SICAM IEC Channel


• Communication with IEC 61850 devices with IEC61850 Edition 2 extended with further
CDCs
• Efficiency of "Buffered Report" function improved: Now a selective query is performed for
data buffered in the connected devices
• SCD Import now supports enumerations

SICAM Graphic Objects Library


• New SICAM Numeric Controls for display of measured and metered values, and
additionally with setpoint output for SICAM PAS connection

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

5.7 SICAM SCC V8.01 Compared to SICAM PAS CC V8.00


General Information
NOTE
Conversion of topological coloring required
• The Runtime for topological coloring was converted to Visual Basic Script in order to
improve its performance and functionality. This means that the topological coloring must be
generated once again.

Licensing
• SICAM SCC can be operated with a full license, with a 14-day trial license or in Demo
mode. The Demo mode is only available for SICAM SCC V8 components.
• During operation without valid SICAM SCC licenses a trial license is offered for most of the
components. This license can only be used once and is valid over a period of 14 days after
activating the Trial mode.
• The Trial mode can also be skipped; in this case SICAM SCC switches over to Demo
mode.
• The purpose of the Demo mode is to enable operation for presentation purposes and for
changing configuration settings on site if e.g. only a Runtime license has been installed.
• In Demo mode configuration in the Graphics Designer is possible for approximately 30
minutes. Afterwards the Graphics Designer must be closed. Data cannot be imported in
Demo mode using the SICAM wizards.
• A reminder message is shown in Runtime at cyclical intervals in order to inform the user
that SICAM SCC runs in Demo mode.

NOTE
If you do not want to show the Trial box during presentations, make sure that the Trial period
has expired before you start your presentation.

SICAM Add-in
• Conversion to Visual Basic Script and revised generation of the topological coloring scripts

Unrestricted – Siemens Aktiengesellschaft Page 16 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Functions
• New function for the object-specific blocking of information

SICAM Wizard
• Accelerated import of messages into the Message Management System

SICAM IEC Channel


• Communication with IEC 61850 devices now also with IEC61850 Edition 2

SICAM Graphic Objects Library


• New SICAM switching device and bay overview objects
• Updated topology templates

SICAM Web Navigator Plug-Ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

5.8 SICAM SCC V8.00 Compared to SICAM PAS CC V7.02


General Information
• SIMATIC WinCC V7.2 supported
NOTE
Conversion of the project required

SICAM Add-In
• New tasks for upgrading the switching device objects and the bay overview objects

SICAM Functions
• Support of the new switching device objects for SICAM SCC Runtime Data Server

SICAM Wizard
• Support of SICAM SCC Runtime Data Server
• Speed-up of tag import

SICAM PAS Channel


• Support of SICAM SCC Runtime Data Server

SICAM RTU Connection via IEC60870-5-104


• Using the “Ini-Timeout” parameter in TOOLBOX II, the user can determine whether:
• all indications with the cause “General Interrogation”
• or only the pending single-point indications with this cause
• are logged in the event list upon the start-up of SICAM SCC.
(for information: “Ini-Timeout” basically controls how long ‘invalid’ indications are suppressed
during start-up)

Unrestricted – Siemens Aktiengesellschaft Page 17 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Alarm Logging System


• In the message list templates of the graphic object library, statistics information has been
added to the hit list.

SICAM Switching Objects and SICAM Runtime Data Server


• To increase the number of versions supported by SICAM SCC, the SICAM SCC Runtime
Data Server component has been introduced. The SICAM SCC Runtime Data Server
processes all process data of the SICAM SCC project, whether they are currently displayed
in a diagram or not. SIMATIC WinCC V7.0 SP3 or higher is required for the SICAM SCC
Runtime Data Server component.
• New projects are automatically configured to run with the SICAM SCC Runtime Data
Server. Existing projects can be converted, but can also continue to run without conversion.
• To convert existing projects (base SIMATIC WinCC V7.0 SP3 or higher) for operation with
SICAM SCC Runtime Data Server, you have to perform the following conversion steps:
• Delete and re-import the process data with the corresponding Wizard (at least SICAM
process tags function).
• Re-import the SICAM graphic object library into your project.
• If used, remove the topological coloring.
• Upgrade the switching device objects and the bay overview objects via SICAM menu of
the Graphics Designer (show task dialog – perform the upgrade of V7 switching device
objects and bay overview objects for each diagram).
• If used, re-create the topological coloring.
• Replace the Button quit blinking in the diagrams.

SICAM Graphic Object Library


• New switching device objects and bay overview objects
• Updated operator elements
• Updated templates for topology
• Templates for message lists with statistics information in the hit list

SICAM Redundancy Components


• The redundancy component IX State Synch should only be installed with WinCC V6.2. It
cannot be run in parallel with the SICAM SCC Runtime Data Server.
• With SIMATIC WinCC V7.0 and later the redundancy alignment of the diagrams is
performed by the SICAM SCC Runtime Data Server in conjunction with the new switching
device objects.

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

5.9 SICAM SCC V7.02 Compared to SICAM PAS CC V7.01


General Information
• Replacement of SICAM WinCC by integration of SICAM SAS connection. Installation via
selection of the appropriate components during custom setup.
• Installation of SICAM 1703 connection via selection of the appropriate components during
custom setup.

Unrestricted – Siemens Aktiengesellschaft Page 18 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Functions
• Scripts for SICAM SAS connection integrated

SICAM Wizard
• Global Wizard for SICAM SAS connection integrated

SICAM PAS Channel


• ComFault and OprReady are entered in the message lists even without mapping them to
diagrams, like in SICAM SCC V7.0 (SP1).

SICAM Alarm Logging System


• Extension of the Message Coloring function by WinCC status texts (RAISED, RAISED
Ack, CLEARED, CLEARED Ack).

SICAM Switching Objects (IndustrialX Controls)


• Switching device objects for SICAM SAS connection integrated

SICAM Graphic Object Library


• Updated SICAM objects
• Objects for SICAM SAS connection integrated

SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.04 installation is included to the SICAM SCC DVD and
can be installed from there.
• Observe the separate readme file enclosed there.
• In the Recpro setup directory the current Recpro hotfix may be available; install this as well,
if applicable.

SICAM RecProtec
• SICAM RecProtec is not included in the installation of SICAM SCC. You can continue using
SICAM RecProtec V6.0x. The SICAM SCC DVD includes a SICAM Recpro V6.04
installation with SICAM RecProtec. It can be installed from there.
• Observe the separate readme file enclosed there.
• In the Recpro setup directory the current Recpro hotfix may be available; install this as well,
if applicable.

SICAM Recpro for SAS


• Recpro Calling Engine for SICAM SAS connection is integrated in SICAM Recpro V6.04
installation.
• Observe the separate readme file enclosed there.
• In the Recpro setup directory the current Recpro hotfix may be available; install this as well,
if applicable.

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

Unrestricted – Siemens Aktiengesellschaft Page 19 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

5.10 SICAM SCC V7.01 Compared to SICAM PAS CCV7.00 SP1


General Information
• Support of SIMATIC WinCC V7.0 SP3
• With SIMATIC WinCC V7.0 SP3 support of Windows 7 64-bit and Windows Server 2008 R2
64-bit.

SICAM Add-In
• For project conversion via SIMATIC WinCC Project Migrator tool and when using
CrossReference, it is not necessary to deactivate the SICAM Add-In in the Graphics
Designer anymore.

SICAM PAS Channel


• In combination with SICAM PAS systems a log has been introduced to avoid multiple or
missing messages after connection interruptions and downtimes (available in combination
with SICAM PAS V7.0 SP3 HF4)

SICAM Alarm Logging System


• The WinCC server can lock messages. The lock is not being transferred to other WinCC
computers via the automation system.
• In combination with SICAM PAS systems a log has been introduced to avoid multiple or
missing messages after connection interruptions and downtimes (available in combination
with SICAM PAS V7.0 SP3 HF4)

SICAM Switching Objects (IndustrialX Controls)


• After switching pictures during a connection interruption, the status display of the overview
objects and switching device objects has been harmonized
• During the connection to SICAM 1703 or IEC 61850 devices, commands must be sent
with qualifiers of command (QoC) when commands are issued. To activate the function,
select Send QoC with Command Value in the Properties dialog of the switching device.
Then, you can set the values that shall be sent in the Preset section. If you need the
possibility to display and change the values in the switching dialog at runtime, select the
option Visible in RT.

SICAM Graphic Object Library


• Updated SICAM objects

SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.03 SP6 installation is included to the SICAM SCC V7.01
DVD and can be installed from there.

• When selecting the Delete fault record after successful transmission parameter in the
Recpro Collector, you can now define via the RpCol.ini file in the Number of Deleted
Records entry how many of the deleted fault records shall remain in the administration file
(frcdlist.csv) of the source archive.

NOTE
o The communication driver checks the administration file to determine whether fault
records existing in the device have already been transmitted into the source archive.
o If the device includes more fault records than the administration file, those records which
are not included in the file will be transmitted.

Unrestricted – Siemens Aktiengesellschaft Page 20 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

o Following deletion by the Recpro Collector, the last 10 entries will remain by default in the
administration file in SICAM PAS CC V6.03 until now because SIPROTEC 4 devices
cannot store a larger number of fault records.
o Certain devices from third-party manufacturers can store a larger number fault records.
For the Number of Deleted Records entry in the RpCol.ini file, you should therefore
define a value which is greater than the maximum number of the fault records stored in a
protection device. (Default value in the new RpCol.ini = 100).

In the Recpro setup directory the current Recpro hotfix may be available; install this as well, if
applicable.

SICAM RecProtec
• SICAM RecProtec is not included in the installation of SICAM SCC V7.01. You can
continue using SICAM RecProtec V6.0x. The SICAM SCC V7.01 DVD includes a SICAM
Recpro V6.03 SP6 installation with SICAM RecProtec. It can be installed from there.
• The entries in the information area of the Windows taskbar are now updated after each
polling cycle.
• If the ALM service has not yet run up, the license query is repeated 3 times every 30
seconds.
• The stability of the communication component has been improved.
• If the communication component cannot be started, the start attempt is repeated 3 times
every 30 seconds.
• For the upfsam_config.exe, the tooltip for the fault record overview has been completed.

SICAM redundancy components


• Alarm Acknowledge Sync
The synchronization of acknowledgment data in the Alarm Logging is done automatically
as of SIMATIC WinCC V6.2. To activate the synchronization functionality for SIMATIC
WinCC V6.0 SP4 installations, you have to install a registry key. The corresponding .reg file
"AckSyncChannels.reg" can be found as .zip file on the product DVD within the
ProductEnhancements\AlarmAcknowledgeSync4WinCCV60 directory.

• SICAM IX State Sync


The application IX State Sync must no longer be started via Windows Startup folder, but
has to be inserted in the WinCC startup list. Thus, the application is automatically started
and stopped together with the WinCC Runtime.
Add SICAM IX State Sync to the WinCC startup list.
To do this first you have to load the SynchTool.exe file from the \PAS CC\SynchTool\bin
subdirectory of the SICAM installation directory via Add… under Additional
Tasks/Applications.

Without a running WinCC Runtime, IX State Sync stops automatically. Therefore the
WinCC Runtime must be running during configuration of IX State Sync.

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

Unrestricted – Siemens Aktiengesellschaft Page 21 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

5.11 SICAM PAS CC V7.00 SP1 Compared to V7.00

General Information
• Support of Windows 7 and Windows Server 2008 (consider WinCC version).
• Support of SIMATIC WinCC V7.0 SP2
• New connectivity of SICAM PAS CC to SICAM 1703 family devices and IEC 61850
devices.

SICAM IEC channel


• New SICAM IEC Communication Suite
• Communication with SICAM 1703 family devices via IEC 61850 and IEC 60870-5-104
• Communication with IEC 61850 devices

SICAM Wizard for TOOLBOX II / SCD data


• New variant of the SICAM Wizard
• Data import of TOOLBOX II data for SICAM PAS CC
• Data import and –selection from SCD, ICD, and CID files (6MD5500-0EP00-7AA0,
licensed)

SICAM Graphic Object Library


• Templates for switching objects and message lists for SICAM 1703 and IEC 61850
device connection

SICAM functions
• New template for a Global action “Sicam_IEC61850_DeviceGI.pas“ for sending a
general interrogation command to directly connected IEC 61850 devices. You can find
the template in the installation directory of SICAM PAS CC in the subdirectory „PAS“.
This template is used for each device and allows a device-specific general interrogation.
Consider the configuration information inside the function.

SICAM PAS CC manual


• New edition with add-ons for connection to the SICAM 1703 family and IEC 61850
devices.

SICAM Functions
• Add-on for new target systems

SICAM Wizard
• Add-ons for new target systems

SICAM PAS Channel


• Process value changes, which occurred while the connection to SICAM PAS was
interrupted, are up-dated correctly.

SICAM PDR
• SICAM PDR is not included in the scope of delivery of SICAM PAS CC V7.00.

SICAM Switching Objects (IndustrialX Controls)


• In the bay overview object, the license check has been improved.

Unrestricted – Siemens Aktiengesellschaft Page 22 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

• In large pictures, the data exchange performance between IndustrialX controls and WinCC
data manager is improved by adjusting the IX tag update cycle.
WinCC Script runtime will not be frozen by switching pictures.
• In large pictures, the display of bitmaps in switch controls is optimized. Switch controls with
bitmaps are shown fast and correctly when switching pictures or zooming.
Bitmaps having the same path will be loaded only once.

NOTE
o The new property “AckTagCycleTime” enables you to set the update cycle of the
acknowledge tag. By default, this value is the same as for the WinCC update cycle
(property “TagCycleTime”).
You can change this value via the WinCC object properties dialog.
o If you change the update cycle “TagCycleTime” via the IndustrialX controls property dialog,
the property “AckTagCycleTime” will be set to the same new value as “TagCycleTime”.

SICAM Graphic Object Library


• Updated SICAM objects, add-ons for new target systems.

SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.03 SP6 installation is included to the SICAM PAS CC
V7.00 SP1 DVD and can be installed from there.
• When selecting the Delete fault record after successful transmission parameter in the
Recpro Collector, you can now define via the RpCol.ini file in the Number of Deleted
Records entry how many of the deleted fault records shall remain in the administration file
(frcdlist.csv) of the source archive.

NOTE
o The communication driver checks the administration file to determine whether fault
records existing in the device have already been transmitted into the source archive.
o If the device includes more fault records than the administration file, those records which
are not included in the file will be transmitted.
o Following deletion by the Recpro Collector, the last 10 entries will remain by default in the
administration file in SICAM PAS CC V6.03 until now because SIPROTEC 4 devices
cannot store a larger number of fault records.
o Certain devices from third-party manufacturers can store a larger number fault records.
For the Number of Deleted Records entry in the RpCol.ini file, you should therefore
define a value which is greater than the maximum number of the fault records stored in a
protection device. (Default value in the new RpCol.ini = 100).

SICAM RecProtec
• SICAM RecProtec is not included in the installation of SICAM PAS CC V7.00. You can
continue using SICAM RecProtec V6.0x. The SICAM PAS CC V7.00 SP1 DVD includes a
SICAM Recpro V6.03 SP6 installation with SICAM RecProtec. It can be installed from
there.
• The entries in the information area of the Windows taskbar are now updated after each
polling cycle.
• If the ALM service has not yet run up, the license query is repeated 3 times every 30
seconds.
• The stability of the communication component has been improved.
• If the communication component cannot be started, the start attempt is repeated 3 times
every 30 seconds.
• For the upfsam_config.exe, the tooltip for the fault record overview has been completed.

Unrestricted – Siemens Aktiengesellschaft Page 23 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Valpro
• Improvement for operation in other time zones than UTC+1.

SICAM Web Navigator Plug-ins


Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions

5.12 SICAM PAS CC V7.00 Compared to the V6.0x Versions

General Information
• No operation together with SICAM WinCC V5.03 possible

SICAM Add-In
• New version with extended functionality

SICAM functions
• Debugging

SICAM PAS Channel


• New redundancy concept, simultaneous communication with the 2 redundant SICAM PAS
systems.
• Configuration in SICAM PAS not as DIP anymore, but as slave connection. Observe the
configuration notes.

SICAM PDR
• SICAM PDR is not included in the scope of delivery of SICAM PAS CC V7.00.

SICAM Switching Objects (IndustrialX Controls)


• Settings made in the WinCC User Administrator are also considered in the Web Navigator.

SICAM Graphic Object Library


• SICAM objects updated

SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.03 installation is included to the SICAM PAS CC V7.0
DVD and can be installed from there.

SICAM RecProtec
• SICAM RecProtec is not included in the scope of delivery of SICAM PAS CC V7.00. You
can continue using SICAM RecProtec V6.0x. The SICAM PAS CC V7.0 DVD includes a
SICAM Recpro V6.03 installation with SICAM RecProtec. It can be installed from there.

SICAM Topological Coloring


• The display times of pictures with topological coloring have been significantly reduced.
Upon initializing, the current value is only forwarded when data actually exist. Therefore,
the feeder/ground objects must transmit their state upon start-up (the configuration must be
adapted accordingly, see notes below).

Unrestricted – Siemens Aktiengesellschaft Page 24 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

• In the bay overview object, the output behavior for line color changes has been improved.
• Improvement of dynamic behavior in pdlrt.exe. When diagrams with many active
topological objects are open, WinCC pdlrt.exe will no longer be closed sporadically.
• If topological coloring is used, consider the following notes:
• To reduce the display times, the transmission of the OFF color in switching device
objects upon initializing has been removed. For this reason, the line parameters and
nodes must always be defined in OFF color.

Existing configurations can be adapted by means of the SICAM toolbar.

Proceed as follows to simultaneously modify the color of several objects:


Define a selection area, select a line or node in this area and then select identical
objects.

• Upon initializing, the ground objects must transmit the grounded state to the line,
because they are no longer triggered by the switching objects.

Existing configurations can be adapted by means of the SICAM toolbar.

Proceed as follows to ensure that the ground objects transmit the grounded state to the
line upon initializing:
Define a selection area, select a ground object in this area and then select identical
objects. In the SICAM menu under settings, select upgrade Topological Ground and
then Group parameterize…. In this way, you connect the ActivateControls variable to
the RGBValue property of all ground objects.

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions.

5.13 SICAM PAS CC V6.0x Versions Compared to V5.11

General Information
• The operating system Windows Vista is supported.
• SIMATIC WinCC V6.2, V6.2 SP2, V6.2 SP3, V7.0 and V7.0 SP1 are supported.
• Operation together with SICAM WinCC V5.03 possible
• New Substitutions function in IndustrialX Controls, measured-value objects (structure
types)
• New concept for topological coloring

SICAM Functions
• New functions for substitution

SICAM Global Wizard


• If problems occur with an existing project during archiving in TagLogging, follow the
instructions of the wizard and delete the SICAM Archives. In TagLogging, the
MeasuredValueArchive_x and MeteredValueArchive_x archives created by the wizard and
the SICAM time must be deleted manually afterwards. Next, you can reimport the archive
variables using the wizard.

Unrestricted – Siemens Aktiengesellschaft Page 25 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

• To be able to use the new “substitutions” function in existing projects created in older
versions, the related structure types must be converted.
There are 2 possibilities for the conversion of the structure types:
Possibility 1:
Follow the description in the configuration information “CompPack_ConfigTool.pdf“, from
SICAM PAS CC V7.0 on in the user guide.
Possibility 2:
Delete the “SICAM Process Tags” with the Wizard. Then delete the structure types in your
project manually and import the “SICAM Process Tags” again with the Wizard. Extended
structure types are generated by these steps.

SICAM PAS Channel


• To be able to display different SICAM PAS versions simultaneously in a SICAM PAS CC
project, different channels (SICAM PAS PROTOCOL SUITE V5 and V6) are provided for
the connection to SICAM PAS V5.11 or SICAM PAS V6.00.
These channels connect only to the corresponding SICAM PAS versions. This means that
data in a channel for SICAM PAS V5.11 always stay in this version, even if you install a new
SICAM PAS CC version.
In contrast to that, the SICAM PAS CC default channel (SICAM PAS PROTOCOL SUITE)
always communicates with the corresponding SICAM PAS version. The data in the default
channel are migrated automatically to a new (higher) version, so that it is not necessary to
change the configuration after an update.

The SIMATIC WinCC Tag Management allows you to load the SICAM PAS PROTOCOL
SUITE V5.chn or the SICAM PAS PROTOCOL SUITE V6.chn. Afterwards, select the
desired channel PAS DATA SERVER V5 or PAS DATA SERVER V6 in the SICAM PAS
Wizard during the data import.
• For more details on the configuration and update of SICAM PAS/SICAM PAS CC systems
with different versions, refer to the configuration information “CompPack_ConfigTool.pdf”,
from SICAM PAS CC V7.0 on in the user guide.

SICAM Alarm Logging System


• It is possible to filter indication lists for process values in text form with SIMATIC WinCC
V7.0 SP1.

SICAM PDR
• The function PDR (Post Disturbance Review) is reached by using different components
simultaneously:
• SICAM PDR Recorder (separate download)
The component SICAM PDR Recorder is available with the SICAM PAS V6.00 PDR
Recorder Add-on V1.00 (separate download). The task of this function in SICAM PAS is
to record the desired data of connected devices - tripped by an event (Trigger) - for a
predefined period. The resulting data are called PDR Records.
• SICAM PDR Player
The component SICAM PDR Player is available. The SICAM PDR Player has 3
components: SICAM PDR Collector allows you to transmit the PDR Records to an
archive and evaluation computer. SICAM Recpro Explorer allows you to navigate in the
archive. The SICAM PDR Viewer is used to evaluate data via graphical and tabular
representations.

Unrestricted – Siemens Aktiengesellschaft Page 26 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

SICAM Recpro
• Customer-specific copy function in the Recpro Collector.
• The user interface can now also be switched to Russian or Chinese.
• Recpro supports the same functions as Recpro for SICAM WinCC V5.03.

SICAM RecProtec
• Fault-record transmission from SIPROTEC 4 devices possible via a direct connection and
via modem connection.

For more detailed information, refer to the SICAM RecProtec manual.

For the operation, Siemens recommends the same modems as for DIGSI (see
www.siprotec.de)

SICAM redundancy components


• New “IX State Sync” application and comparison of acknowledgments of the alarm lists.
The following changes are applied to this application:
• The Wizard creates an internal tag “SICAMPASCCSynchState”. The application “IX
State comparison” needs an internal “string”-type tag “SICAMPASCCSynchState” to
detect, whether WinCC Runtime is running.
The application writes the state cyclically into this tag.
If the application can write into this tag, the WinCC Runtime is running.
• The setup creates an entry in the Windows Registry.
It sets the value of the “IXOperatingMode" setting in the Registry Key
“HKEY_LOCAL_MACHINE\SOFTWARE\Siemens\SICAM PAS CC\SETUP" to 1.
This leads switching device objects to take over changes from the *.IXHook tag into their
own state.

SICAM Switching Objects (IndustrialX Controls)


• A new function has been implemented for substitutions.
• Faster display-refresh rates:
• Controls now provide a new property referred to as “Activate“. This property must be
connected to a WinCC tag of the “binary” type. The tag must have the starting value “1”.
Controls can only log on to the WinCC data management if the related tag has the value
“1”. If the tag connection is missing or the tag value is not “1”, then the switching device
objects show the states “not actual” and “disturbed position”!
• If you use picture windows with tag prefix, then the prefix also has an impact on the
activation tag associated with the “Activate” property. In this case, create a single tag
manually for each prefix used in the tag management. Example: The tag
“ActivateControls” is associated to the “Activate” property. The tag prefix of the picture
window is “Bay_32_”. In this case, create an internal binary tag with the name
“Bay_32_ActivateControls” and the starting value “1” in the WinCC Tag Management in
the SICAMAdmin group.
• Integrated blinking frequency
Controls feature an integrated blinking timer. With Version SICAM PAS CC V 5.11 or higher,
the internal tags “@FlashFast, @FlashMedium and @FlashSlow” are no longer required
for the controls. The “Sicam_FlashSyn.pas” script is no longer required for the controls.

Unrestricted – Siemens Aktiengesellschaft Page 27 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

• Utility software for upgrades


A utility software is provided for upgrades of previous versions to V6.00. The utility software
connects the new property of all controls of a WinCC diagram with a selectable WinCC tag.
The utility software can be opened in the Graphics Designer via the “SICAM – Upgrade
Controls…” menu item. The correct name of the control property is assigned by default.
The tag name is a suggestion you can always change.
When clicking “OK”, the tag connections are shown on all controls in the active diagram.

SICAM Graphic Object Library


• Graphic object libraries with SIMATIC WinCC V6.x and V7.0 objects are available. The
Wizard imports the library corresponding to the SIMATIC WinCC version into your project
(The 2 libraries can be found in the “lib” folder of your SICAM PAS CC installation directory.
If necessary, you can copy the desired library manually as library.pxl into the WinCC project
index.).
• This version is used to install new SICAM PAS CC V6.00 graphic objects and extensions of
the WinCC Graphics Designer which support the topological coloring of WinCC diagrams
during runtime.
• Measured-value objects with the new substitution function

SICAM Valpro
• The user interface can now also be switched to Russian.

SICAM Web Navigator Plug-ins


• Updated Web Navigator plug-ins for all supported SIMATIC WinCC versions.
• To configure an automatic diagram change to an empty diagram without operating options
in case of compatibility-key errors, insert the “HelperObject WebNavCompKeyPicChanger”
into your Web diagrams and set the “Display” property to NO.

Unrestricted – Siemens Aktiengesellschaft Page 28 of 29


Copyrights  Siemens AG 2018 All Rights Reserved
SICAM SCC V9.03 2018-12
Readme

6 Open Source Software Used in the Product


The product contains, among other things, Open Source Software developed by third parties.
The Open Source Software used in the product and the license agreements concerning this
software can be found in the Readme_OSS.

These Open Source Software files are protected by copyright. Your compliance with those
license conditions will entitle you to use the Open Source Software as foreseen in the relevant
license. In the event of conflicts between Siemens license conditions and the Open Source
Software license conditions, the Open Source Software conditions shall prevail with respect to
the Open Source Software portions of the software.

The Open Source Software is licensed royalty-free. Insofar as the applicable Open Source
Software License Conditions provide for it you can order the source code of the Open Source
Software from your Siemens sales contact - against payment of the shipping and handling
charges - for a period of at least 3 years since purchase of the Product. We are liable for the
Product including the Open Source Software contained in it pursuant to the license conditions
applicable to the Product. Any liability for the Open Source Software beyond the program flow
intended for the Product is explicitly excluded. Furthermore any liability for defects resulting
from modifications to the Open Source Software by you or third parties is excluded. We do not
provide any technical support for the Product if it has been modified.

7 Contact
Our customer support center provides around-the-clock support.

Customer Support Center


Tel: + 49 (180) 524-7000
Fax: + 49 (180) 524-2471
E-mail: [email protected]
http://www.siemens.com/energy-support/en

Unrestricted – Siemens Aktiengesellschaft Page 29 of 29


Copyrights  Siemens AG 2018 All Rights Reserved

You might also like