Readme B
Readme B
03 2018-12
Readme
1 Compatibility .................................................................................................. 3
2 Converting Projects from Former Versions ................................................. 3
3 General Restrictions ...................................................................................... 4
3.1 SICAM Wizards ................................................................................................ 4
3.1.1 SICAM IEC Wizard ........................................................................................... 4
3.1.2 SICAM TEA-X Wizard ...................................................................................... 4
3.2 SICAM Network Manager ................................................................................. 5
3.3 SIMATIC WinCC Web Navigator ...................................................................... 5
3.3.1 Display of Switching Objects up to SICAM SCC V7.02 with own Pictures ........ 5
3.4 Topology .......................................................................................................... 5
3.5 Topology with SIMATIC WinCC V7.4 SP1 and V7.5......................................... 5
3.6 Dynamic Alarm Filter ........................................................................................ 5
3.6.1 DAF – Configuration of Alarm System .............................................................. 5
3.7 SICAM Switching Device Objects V8.0 and later .............................................. 6
3.7.1 Touch Operation .............................................................................................. 6
3.7.2 Displaying Switching Objects with own Pictures ............................................... 6
3.8 SICAM IndustrialX Controls up to V7.02 ........................................................... 6
3.8.1 Displaying Switching Objects with own Pictures ............................................... 7
3.8.2 SICAM SCC LS/TR IndustrialX Control ............................................................ 7
3.8.3 SICAM WinCC V3 IndustrialX Control .............................................................. 7
3.9 IEC Communication Suite ................................................................................ 7
3.9.1 IEC Communication Suite – Buffered Report with IEC 61850........................... 7
3.9.2 IEC Communication Suite – Connection of IEC 60870-5-104 Devices ............. 7
3.10 Connection to SICAM PAS from SICAM PAS V7 ............................................. 7
3.10.1 Redundant SICAM PAS .............................................................................. 7
3.11 Connection to SICAM PAS of Earlier Versions ................................................. 8
3.11.1 SICAM PAS Channels of Earlier Versions ................................................... 8
3.11.2 Normalization DLL....................................................................................... 8
3.12 SICAM Valpro .................................................................................................. 8
3.13 WinCC Report Designer ................................................................................... 8
3.13.1 WinCC Alarm Log with Line Printer ............................................................. 8
3.13.2 WinCC Message Sequence Report with Page Printer ................................. 9
4 Changes Compared to Previous Version ................................................... 10
5 Revision History ........................................................................................... 11
5.1 SICAM SCC V9.02 Compared to SICAM SCC V9.01 ..................................... 11
5.2 SICAM SCC V9.01 Compared to SICAM SCC V9.00 ..................................... 12
5.3 SICAM SCC V9.00 Compared to SICAM SCC V8.04 ..................................... 12
5.4 SICAM SCC V8.04 Compared to SICAM SCC V8.03 ..................................... 14
5.5 SICAM SCC V8.03 Compared to SICAM SCC V8.02 ..................................... 15
5.6 SICAM SCC V8.02 Compared to SICAM PAS CC V8.01 ............................... 15
5.7 SICAM SCC V8.01 Compared to SICAM PAS CC V8.00 ............................... 16
5.8 SICAM SCC V8.00 Compared to SICAM PAS CC V7.02 ............................... 17
5.9 SICAM SCC V7.02 Compared to SICAM PAS CC V7.01 ............................... 18
5.10 SICAM SCC V7.01 Compared to SICAM PAS CCV7.00 SP1 ........................ 20
5.11 SICAM PAS CC V7.00 SP1 Compared to V7.00 ............................................ 22
1 Compatibility
The licenses for SICAM PAS CC V6.x, V7.x, and V8.0x continue to be valid for SICAM SCC
V9.0x, but they are not compatible with the authorizations of SICAM PAS CC V5 versions.
There is an upgrade license available for former V5 authorizations.
SIMATIC WinCC V7.3 (V7.3 Second Edition) must be installed with at least Update 16.
SIMATIC WinCC V7.4 must be installed with at least SP1 Update 4 and Patch 4/Update 5.
SIMATIC WinCC V7.4 without SP1 cannot be used.
Detailed references regarding SIMATIC WinCC and SIMATIC software can be found in the
WinCC Information System in Installation Requirements and on the following support websites:
The required hotfixes/updates for SIMATIC WinCC are available on the SICAM SCC DVD.
Check whether a new hotfix/update for an installed component is available on the DVD.
In order to be able to run both SICAM SCC and DIGSI 4 on the same computer, install DIGSI
first and then SICAM SCC. Uninstalling just one product is not recommended.
NOTE
After the installation of SICAM SCC, if you install or uninstall SICAM PAS/PQS V8.03 or earlier
or SICAM PQ Analyzer V3.03 or earlier on the same computer, you must repair the SICAM
SCC installation.
To do so, use the functionality provided by the Windows Control Panel.
NOTE
The SICAM PAS Protocol Suite V7 is no longer included. Change your SICAM SCC projects to
the SICAM PAS Protocol Suite standard channel before updating the software.
3 General Restrictions
NOTE
If you migrate a SIMATIC WinCC project or use the OS project editor, deactivate the SICAM
Add-in in Graphics Designer’s Addin-Manager before.
When the Graphics Designer is opened, the SICAM Add-in takes a few seconds. Since the
Graphics Designer gets frequently opened and closed in the background during these
operations, an activated SICAM Add-in could cause delays or abortion of the operations.
If you use Windows 2008 Server SP2 32 Bit, there may be sporadic problems with the WinCC
Project Manager when deleting all imported data of a station/a project. Errors during the
deletion are indicated in the Trace Window. Errors occurring during deletion are reported in the
Report window, and the WinCC Project Manager closes. In this case, create a WinCC Project
and copy the diagrams and other components into the new project.
If you switch the runtime language in SIMATIC WinCC, you have to close and re-open the
WinCC project before import/update, in order to get the texts of the import data for the Alarm
Logging System to be written into the text library in the correct language. When updating a
station, the same runtime language must always be used as with the first import.
NOTE
When importing data, observe the maximum number of tags that you have licensed for
SIMATIC WinCC. In SICAM systems every data structure is numbered as a tag.
If the maximum number of your licensed tags is exceeded, no further external tags are created
by WinCC. However, the internal parts of the tag structures are created. If this problem
occurred you have to delete all imported data of the project with the Wizard and then delete the
remaining external structure tags and internal single tags (*.RTInfo, *.RTCmd, *.RTSync, and
*.IXHook).
After installing a license for the required number of tags (the “smaller” license has to be deleted!)
or removing tags from the mapping to SICAM SCC, you can do a re-import.
Close the WinCC Configuration Studio before importing data with the TEA-X Wizard to avoid
access contentions.
If you want to configure PAS or IEC connections later, you can, for example, pass through the
SICAM PAS Wizard with the option Create SICAM components in project without import data
before starting the SICAM Network Manager.
After this initialization all Wizards and the Network Manager can be used.
For redundant SICAM SCC systems, each server enters messages in the message lists.
Because of the Online synchronization for Alarm Logging of the WinCC redundancy, you
then see these messages twice.
After installation of the plugin, the SCCCommon.dll file has to be registered on the Web
Navigator Client. To do so, execute the SCCCommon.bat file with administrator rights in the
Program Files (x86)\Common Files\Siemens\Bin folder.
3.3.1 Display of Switching Objects up to SICAM SCC V7.02 with own Pictures
If user-specific bitmaps, configured without absolute path in SICAM SCC up to V7.02, are used
for display within the switching objects, these are not displayed during runtime in WinCC V7.2
or higher. The default search path is relative to the folder Program Files (x86)\Siemens\WinCC\
WebNavigator\Client\bin. You can reference the used bitmaps using this path or store them in
this location.
3.4 Topology
To be able to use the new Topological Coloring of V9.00 or higher, you have to adjust the
existing configurations. Consider the notes regarding conversion in the manual.
The previous Topological Coloring is not supported anymore.
o Open the properties of the message types in the Alarm Logging and select the
Flashing on option to activate flashing.
It is possible to display the user name in the message lists during runtime, when the
DAF is used. When a message is entered into to the message list the content of the
variable DAF_Username is written into the User Name DAF column.
Write the current user name, e.g. while sending a command, into the variable
DAF_UserName. The variable can be found in the tag management within the internal
tags folder in the SICAMDAF group.
In the Graphics Designer open a picture with a SICAM SCC message list for DAF.
In the Message lists tab of the WinCC AlarmControl properties you can now add the
User Name DAF from the available message blocks to the message list.
If you use the DAF_Username for messages that have to be acknowledged, consider
the corresponding configuration information. This allows you to configure an operation
message as acknowledgment message, containing the user who was logged on during
acknowledgment.
Messages which are displayed colored in the event list are displayed with GO color for
both COME and GO state.
NOTE
To be able to operate left and right mouse buttons via touch screen for SICAM switching objects
in older WinCC versions, place a transparent button on top of the SICAM switch and call the
same object functions for the button events Mouse Click and Press Right as provided in the
SICAM switch for OnLeftClick and OnRightClick.
However, in the VB Script of the button you have to hand over the name of the object. For
example, item.ShowSwitchDialog becomes Screenitems("<objectname of SICAM
switch>").ShowSwitchDialog.
Click OK to confirm your selection of process tags in the tag-selection dialog. A double-click
would only open an empty field.
For the connection via the IEC Communication Suite the LS/TR object with CScript, SBO and
QoC is available in the library. This object supports the output via CScript.
With redundant SICAM SCC systems, double entries may occur in the message lists if the
IEC 61850 devices operate with Buffered Report.
This behavior especially occurs after connection interruptions or after restart of the SCC
Runtime on one of the redundant SCC systems.
The channels of earlier SICAM PAS CC/SCC versions do not support the current switching
device objects introduced with SICAM SCC V8.00 and the SICAM SCC Runtime Data Server.
If you use one of the V5, V6 or V7 SICAM PAS channels included in the scope of delivery in
order to set up a connection to SICAM PAS, you use the V7.x IndustrialX switching device
objects which are also available in the Graphic Objects Library.
The channels of earlier versions do not provide the additional process data required for the
SICAM SCC Runtime Data Server. For this reason its functions are not available for tags from
these channels (e.g. spontaneous blinking).
After changing the ProjectID resp. HMIInterfaceID (e.g. when creating a redundant project)
these settings have to be redone.
When following the instructions of the SICAM PAS Wizard, the layout of the SICAM line printer
is copied into the project directory using the Create SICAM Alarm Logging System option.
When installing a new version of SICAM SCC, the sicam_signallist_lineprinter.rp1 file must
be copied from the ”..\WinCC\Syslay” directory into the ”..\<Projectname>\prt” directory.
When opening the Report Designer for the first time, the SICAM layouts are copied into the
project directory. When installing a new version of SICAM SCC, the following files must be
copied from the ”..\WinCC\Syslay” directory into the ”..\<Projectname>\prt” directory:
• @sicam_signallist_pageprinter.rpl
• @sicam_signallist_pageprinter_land.rpl
• @sicam_short_term_pageprinter.rpl
• @sicam_short_term_pageprinter_land.rpl
5 Revision History
5.1 SICAM SCC V9.02 Compared to SICAM SCC V9.01
General Information
• SIMATIC WinCC V7.4 is not supported anymore.
SICAM Functions
• The SICAM SCC\Misc folder contains the new CScript SCC_CopyTagValueRT.fct.
SICAM TOOLBOX II
• Extended acquisition of communication parameters from the OPM into the initializing files
of IEC 61850 and IEC 60870-5-104 connections
SICAM Functions
• The SICAM SCC\Command folder contains new CScripts for output of analog setpoints
with QoC; the other CScripts have been revised. Use these for new projects.
SICAM TOOLBOX II
• Extended acquisition of communication parameters from the OPM into the initializing files
of IEC 61850 and IEC 60870-5-104 connections.
Topological Coloring
• New topology components implemented
• A license key is needed for topological coloring
• New topology toolbar
• Consider the notes regarding conversion in the manual
SICAM Functions
• Under the project functions in the C editor of the Global Scripts a new folder has been
added containing revised CScripts. Use these for new projects.
General Information
• Extended Demo project (e.g. zoom and navigation window)
• Template project for micro grids
SICAM Wizards
• New Wizard for import of TEA-X files from SICAM PAS (no Unicode support).
If a TEA-X file is imported from SICAM PAS, only 1 SICAM PAS station can be connected.
To connect several SICAM PAS stations to a SICAM SCC, in SICAM PAS – Configuration
set the text format to Short text and the file type for export to PXD.
• When generating the topological coloring, for all SICAM controls the SICAM Addin sets the
topological colors and line types that had been configured.
SICAM Functions
New function for message-specific acknowledgment of alarms
SICAM Wizards
• Import of DIGSI export files (XML format) for devices with IEC 60870-5-104 communication
for direct connection of the devices to SICAM SCC
• During IEC 61850 import of SCL files, only a selection of information mapped in static
datasets is offered for devices which only support static datasets.
For devices supporting both dynamic and static datasets, these can be selected.
SICAM Add-In
• Accelerated creation of the scripts for topological coloring
• Function for replacing measured-value objects with SICAM Numeric Controls
Licensing
• SICAM SCC can be operated with a full license, with a 14-day trial license or in Demo
mode. The Demo mode is only available for SICAM SCC V8 components.
• During operation without valid SICAM SCC licenses a trial license is offered for most of the
components. This license can only be used once and is valid over a period of 14 days after
activating the Trial mode.
• The Trial mode can also be skipped; in this case SICAM SCC switches over to Demo
mode.
• The purpose of the Demo mode is to enable operation for presentation purposes and for
changing configuration settings on site if e.g. only a Runtime license has been installed.
• In Demo mode configuration in the Graphics Designer is possible for approximately 30
minutes. Afterwards the Graphics Designer must be closed. Data cannot be imported in
Demo mode using the SICAM wizards.
• A reminder message is shown in Runtime at cyclical intervals in order to inform the user
that SICAM SCC runs in Demo mode.
NOTE
If you do not want to show the Trial box during presentations, make sure that the Trial period
has expired before you start your presentation.
SICAM Add-in
• Conversion to Visual Basic Script and revised generation of the topological coloring scripts
SICAM Functions
• New function for the object-specific blocking of information
SICAM Wizard
• Accelerated import of messages into the Message Management System
SICAM Add-In
• New tasks for upgrading the switching device objects and the bay overview objects
SICAM Functions
• Support of the new switching device objects for SICAM SCC Runtime Data Server
SICAM Wizard
• Support of SICAM SCC Runtime Data Server
• Speed-up of tag import
SICAM Functions
• Scripts for SICAM SAS connection integrated
SICAM Wizard
• Global Wizard for SICAM SAS connection integrated
SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.04 installation is included to the SICAM SCC DVD and
can be installed from there.
• Observe the separate readme file enclosed there.
• In the Recpro setup directory the current Recpro hotfix may be available; install this as well,
if applicable.
SICAM RecProtec
• SICAM RecProtec is not included in the installation of SICAM SCC. You can continue using
SICAM RecProtec V6.0x. The SICAM SCC DVD includes a SICAM Recpro V6.04
installation with SICAM RecProtec. It can be installed from there.
• Observe the separate readme file enclosed there.
• In the Recpro setup directory the current Recpro hotfix may be available; install this as well,
if applicable.
SICAM Add-In
• For project conversion via SIMATIC WinCC Project Migrator tool and when using
CrossReference, it is not necessary to deactivate the SICAM Add-In in the Graphics
Designer anymore.
SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.03 SP6 installation is included to the SICAM SCC V7.01
DVD and can be installed from there.
• When selecting the Delete fault record after successful transmission parameter in the
Recpro Collector, you can now define via the RpCol.ini file in the Number of Deleted
Records entry how many of the deleted fault records shall remain in the administration file
(frcdlist.csv) of the source archive.
NOTE
o The communication driver checks the administration file to determine whether fault
records existing in the device have already been transmitted into the source archive.
o If the device includes more fault records than the administration file, those records which
are not included in the file will be transmitted.
o Following deletion by the Recpro Collector, the last 10 entries will remain by default in the
administration file in SICAM PAS CC V6.03 until now because SIPROTEC 4 devices
cannot store a larger number of fault records.
o Certain devices from third-party manufacturers can store a larger number fault records.
For the Number of Deleted Records entry in the RpCol.ini file, you should therefore
define a value which is greater than the maximum number of the fault records stored in a
protection device. (Default value in the new RpCol.ini = 100).
In the Recpro setup directory the current Recpro hotfix may be available; install this as well, if
applicable.
SICAM RecProtec
• SICAM RecProtec is not included in the installation of SICAM SCC V7.01. You can
continue using SICAM RecProtec V6.0x. The SICAM SCC V7.01 DVD includes a SICAM
Recpro V6.03 SP6 installation with SICAM RecProtec. It can be installed from there.
• The entries in the information area of the Windows taskbar are now updated after each
polling cycle.
• If the ALM service has not yet run up, the license query is repeated 3 times every 30
seconds.
• The stability of the communication component has been improved.
• If the communication component cannot be started, the start attempt is repeated 3 times
every 30 seconds.
• For the upfsam_config.exe, the tooltip for the fault record overview has been completed.
Without a running WinCC Runtime, IX State Sync stops automatically. Therefore the
WinCC Runtime must be running during configuration of IX State Sync.
General Information
• Support of Windows 7 and Windows Server 2008 (consider WinCC version).
• Support of SIMATIC WinCC V7.0 SP2
• New connectivity of SICAM PAS CC to SICAM 1703 family devices and IEC 61850
devices.
SICAM functions
• New template for a Global action “Sicam_IEC61850_DeviceGI.pas“ for sending a
general interrogation command to directly connected IEC 61850 devices. You can find
the template in the installation directory of SICAM PAS CC in the subdirectory „PAS“.
This template is used for each device and allows a device-specific general interrogation.
Consider the configuration information inside the function.
SICAM Functions
• Add-on for new target systems
SICAM Wizard
• Add-ons for new target systems
SICAM PDR
• SICAM PDR is not included in the scope of delivery of SICAM PAS CC V7.00.
• In large pictures, the data exchange performance between IndustrialX controls and WinCC
data manager is improved by adjusting the IX tag update cycle.
WinCC Script runtime will not be frozen by switching pictures.
• In large pictures, the display of bitmaps in switch controls is optimized. Switch controls with
bitmaps are shown fast and correctly when switching pictures or zooming.
Bitmaps having the same path will be loaded only once.
NOTE
o The new property “AckTagCycleTime” enables you to set the update cycle of the
acknowledge tag. By default, this value is the same as for the WinCC update cycle
(property “TagCycleTime”).
You can change this value via the WinCC object properties dialog.
o If you change the update cycle “TagCycleTime” via the IndustrialX controls property dialog,
the property “AckTagCycleTime” will be set to the same new value as “TagCycleTime”.
SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.03 SP6 installation is included to the SICAM PAS CC
V7.00 SP1 DVD and can be installed from there.
• When selecting the Delete fault record after successful transmission parameter in the
Recpro Collector, you can now define via the RpCol.ini file in the Number of Deleted
Records entry how many of the deleted fault records shall remain in the administration file
(frcdlist.csv) of the source archive.
NOTE
o The communication driver checks the administration file to determine whether fault
records existing in the device have already been transmitted into the source archive.
o If the device includes more fault records than the administration file, those records which
are not included in the file will be transmitted.
o Following deletion by the Recpro Collector, the last 10 entries will remain by default in the
administration file in SICAM PAS CC V6.03 until now because SIPROTEC 4 devices
cannot store a larger number of fault records.
o Certain devices from third-party manufacturers can store a larger number fault records.
For the Number of Deleted Records entry in the RpCol.ini file, you should therefore
define a value which is greater than the maximum number of the fault records stored in a
protection device. (Default value in the new RpCol.ini = 100).
SICAM RecProtec
• SICAM RecProtec is not included in the installation of SICAM PAS CC V7.00. You can
continue using SICAM RecProtec V6.0x. The SICAM PAS CC V7.00 SP1 DVD includes a
SICAM Recpro V6.03 SP6 installation with SICAM RecProtec. It can be installed from
there.
• The entries in the information area of the Windows taskbar are now updated after each
polling cycle.
• If the ALM service has not yet run up, the license query is repeated 3 times every 30
seconds.
• The stability of the communication component has been improved.
• If the communication component cannot be started, the start attempt is repeated 3 times
every 30 seconds.
• For the upfsam_config.exe, the tooltip for the fault record overview has been completed.
SICAM Valpro
• Improvement for operation in other time zones than UTC+1.
General Information
• No operation together with SICAM WinCC V5.03 possible
SICAM Add-In
• New version with extended functionality
SICAM functions
• Debugging
SICAM PDR
• SICAM PDR is not included in the scope of delivery of SICAM PAS CC V7.00.
SICAM Recpro
• If no upgrade to SICAM PQ Analyzer shall be done, SICAM Recpro V6.0x can also be used.
For this case, a SICAM Recpro V6.03 installation is included to the SICAM PAS CC V7.0
DVD and can be installed from there.
SICAM RecProtec
• SICAM RecProtec is not included in the scope of delivery of SICAM PAS CC V7.00. You
can continue using SICAM RecProtec V6.0x. The SICAM PAS CC V7.0 DVD includes a
SICAM Recpro V6.03 installation with SICAM RecProtec. It can be installed from there.
• In the bay overview object, the output behavior for line color changes has been improved.
• Improvement of dynamic behavior in pdlrt.exe. When diagrams with many active
topological objects are open, WinCC pdlrt.exe will no longer be closed sporadically.
• If topological coloring is used, consider the following notes:
• To reduce the display times, the transmission of the OFF color in switching device
objects upon initializing has been removed. For this reason, the line parameters and
nodes must always be defined in OFF color.
• Upon initializing, the ground objects must transmit the grounded state to the line,
because they are no longer triggered by the switching objects.
Proceed as follows to ensure that the ground objects transmit the grounded state to the
line upon initializing:
Define a selection area, select a ground object in this area and then select identical
objects. In the SICAM menu under settings, select upgrade Topological Ground and
then Group parameterize…. In this way, you connect the ActivateControls variable to
the RGBValue property of all ground objects.
General Information
• The operating system Windows Vista is supported.
• SIMATIC WinCC V6.2, V6.2 SP2, V6.2 SP3, V7.0 and V7.0 SP1 are supported.
• Operation together with SICAM WinCC V5.03 possible
• New Substitutions function in IndustrialX Controls, measured-value objects (structure
types)
• New concept for topological coloring
SICAM Functions
• New functions for substitution
• To be able to use the new “substitutions” function in existing projects created in older
versions, the related structure types must be converted.
There are 2 possibilities for the conversion of the structure types:
Possibility 1:
Follow the description in the configuration information “CompPack_ConfigTool.pdf“, from
SICAM PAS CC V7.0 on in the user guide.
Possibility 2:
Delete the “SICAM Process Tags” with the Wizard. Then delete the structure types in your
project manually and import the “SICAM Process Tags” again with the Wizard. Extended
structure types are generated by these steps.
The SIMATIC WinCC Tag Management allows you to load the SICAM PAS PROTOCOL
SUITE V5.chn or the SICAM PAS PROTOCOL SUITE V6.chn. Afterwards, select the
desired channel PAS DATA SERVER V5 or PAS DATA SERVER V6 in the SICAM PAS
Wizard during the data import.
• For more details on the configuration and update of SICAM PAS/SICAM PAS CC systems
with different versions, refer to the configuration information “CompPack_ConfigTool.pdf”,
from SICAM PAS CC V7.0 on in the user guide.
SICAM PDR
• The function PDR (Post Disturbance Review) is reached by using different components
simultaneously:
• SICAM PDR Recorder (separate download)
The component SICAM PDR Recorder is available with the SICAM PAS V6.00 PDR
Recorder Add-on V1.00 (separate download). The task of this function in SICAM PAS is
to record the desired data of connected devices - tripped by an event (Trigger) - for a
predefined period. The resulting data are called PDR Records.
• SICAM PDR Player
The component SICAM PDR Player is available. The SICAM PDR Player has 3
components: SICAM PDR Collector allows you to transmit the PDR Records to an
archive and evaluation computer. SICAM Recpro Explorer allows you to navigate in the
archive. The SICAM PDR Viewer is used to evaluate data via graphical and tabular
representations.
SICAM Recpro
• Customer-specific copy function in the Recpro Collector.
• The user interface can now also be switched to Russian or Chinese.
• Recpro supports the same functions as Recpro for SICAM WinCC V5.03.
SICAM RecProtec
• Fault-record transmission from SIPROTEC 4 devices possible via a direct connection and
via modem connection.
For the operation, Siemens recommends the same modems as for DIGSI (see
www.siprotec.de)
SICAM Valpro
• The user interface can now also be switched to Russian.
These Open Source Software files are protected by copyright. Your compliance with those
license conditions will entitle you to use the Open Source Software as foreseen in the relevant
license. In the event of conflicts between Siemens license conditions and the Open Source
Software license conditions, the Open Source Software conditions shall prevail with respect to
the Open Source Software portions of the software.
The Open Source Software is licensed royalty-free. Insofar as the applicable Open Source
Software License Conditions provide for it you can order the source code of the Open Source
Software from your Siemens sales contact - against payment of the shipping and handling
charges - for a period of at least 3 years since purchase of the Product. We are liable for the
Product including the Open Source Software contained in it pursuant to the license conditions
applicable to the Product. Any liability for the Open Source Software beyond the program flow
intended for the Product is explicitly excluded. Furthermore any liability for defects resulting
from modifications to the Open Source Software by you or third parties is excluded. We do not
provide any technical support for the Product if it has been modified.