0% found this document useful (0 votes)
672 views4 pages

Top 5300

TOP-5300 description

Uploaded by

ayman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
672 views4 pages

Top 5300

TOP-5300 description

Uploaded by

ayman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
Tor TOP Syringe Pump TOP-5300 A standard syringe pump for an age of routine pump use. The range in flow rate settings has Inclined Panel for Easy Visual Confirmation ‘The slope of the panel face has been increased so that numbers on the display and indicator lights can be easily checked, even ata distance. Bolus Function Useful for priming and when bolus injection Is called for. To prevent incorrect operation, the bolus function is designed ta work only when the ml key is pressed at the ‘same time as the bolus key. Alarm Panel Warning lights alert the operator of low battery, low volume, occlusion, and internal malfunctions, Brand Selection Key Lets you select the make of syringe to be used Syringe Verification Key Provided with a key for checking by means of indicator lights thar the settings for the syringe being used are correct, Battery Indicator — A 34evel indicator displays the charging status and remaining capacity of the intemal battery. Power Switch Safety Mechanism builtin safety mechanism prevents the power from shutting off immediately when the ON/OFF key is accidentally pressed during infusion, TTT Mama dal ‘The result is an expanded number of applications, ranging from routine clinical use to supplementary feeding in premature infants and neonates, blood transfusions, ‘chemotherapy in the ICU and CCU, and the infusion of therapeutic drugs such as antineoplastics, obstetric agents, anticoagulants and anesthetics, over a wide range of flow rate settings. Compatible with Other Makes of Syringes Accepts TOP as well as other leading makes of syringes in 10, 20, 30, and 50 mi sizes. The ¢ syringe brand setting can be changed by pressing the brand selection key on the panel.The syringe size is automatically identified when the barrel clamp is set. Specifications 1: TOR TERUMO, B.D, B. BRAUN Specifications 2: B-D, TERUMO, MONOJECT, B. BRAUN Continuously Monitors Plunger A plunger detection sensor checks that the plunger has been properly set. and an internal mechanism continuously monitors plunger movement during infusion. Occlusion Detecting Pressure Alarm is Adjustable There are four switchable pressure levels for detecting occlusion of the infusion line and setting off the occlusion alarm. volume settings for the next use. Power Source Change Alarm If the plug is accidentally pulled or a power failure occurs during AC power operation, the unit automatically switches over to the internal battery and an alarm is sounded Computer Integration System The status of the syringe pump can be remotely Monitored with an RS-232C connector (optional) for external communication. External DC Power Compatible : Connects to external DC power source, enabling use of the pump within an ambulance. Battery Replacement is Easy The batteries can easily be replaced simply by opening the battery cover at the bottom of the unit. Electromagnetic Compat Standards) The pump conforms to the EU standards on electromagnetic compatibility (EMC Standards) which require that devices should not be affected by electromagnetic fields from external sources and should in turn not emit electromagnetic waves sufficient to affect the operation of other electronic devices. jity (EMC TOP Syringe Pump TOP-5300 [a | Description TOP Sringe Pump Mode! TOP-5300 E Power supply ‘AC power source’ ACTOO to 240V=10% 50/60H» lapprox | Exemnel Dt power source: DC12.? to 15V lexact] Buin battery. Rechargeable, DCI2V 700mAh N-Cd Model: 8P-53 Continuous operation: Approx. two haurs (when a new Battery i fully recharged vith smu set) ower consumption AC povies source: 0 3Alapprox) current Excennal DC power source’ 0.5A jexact ee ‘Applicable syringes |0ml. 20m, 30mL ana Smt syringes from 1) Tok TeRUwO"8.0 or &. BALI 2) BD, TERUMO, MONOIECT or 8.BRAUN can be use in he auto Sclecion|#|mode, only the SOmL syringe can be used Flow range 1. 409.6mI7 [ToML syringe) 6.1: 700.0mU% ZoMt Synge) 6.1. 909.0mU7 (Some syringe) 8.1-1500-Om? [50m syringe) [Settings adjustable im 0. Ime increments.) Total infusion 0.1-999.5mL volume range TOP Infusion Stand Infusion accuracy randspecified mode : ‘echanieal accuracy: 21% Accuracy intucing the syringe: #306 ‘Auto selection| made {Only 50mL syringes can be used.| ‘Mechanical accuracy: £1 Accuracy including the syringe: 439% eAccurngy obtained vinen fusion is performed for over one our at Bolus rate ‘Approx. 400.0mL/h (10mL syringe) ‘Approx 700-Omt/h [20mL syringe! ‘Approx $00.OmL/h [30mL syringe) Approx 1500,0mUh (SOL Syringe ‘cculsion detecting 4-step selection pressure Extra high 119.7440. 04Pa/ 9002300mmHg/ 1.2220.41 kgf/cm High: 2” 9311233.34Pay 7008230mmrig? 0'9580.34kgH/em™ Miele: $6 5426.74Pay $008200mmHg/ 0 6820.27eg¢/em: Low: $9154200HPay 30081 Sdmmbg/ 0.4120, 20Ka1/em ‘Atom Low volume (inactive in the auto selection| % Imodel, acculusion, low SH RY meagre oor eon Pe Spansion — Operon tener tne ston 5 ere HT I florm after ti slenced the alarm sounds again Sts memorize! Infusion rate see walue/ Tos infson volume storage Setung is allowed. ure setting: Presence/Aosence of wait tone ang operation tone an be specie Power source switch alarm: Notes by the alarm sound thet power {sino onger supplied from the AC or BC power source and the system ( has entered the atery operation mode. Operating ‘Ambient temparature: 10 r0 40°C condition Relative humidity. 30 19 85% (no condensation} ‘Atmospheric pressure: 70 to 1OGIP pe ‘Ambient temperature: -10 10 # Storage conditions Relaive numa 10 10 90% {no condensation] Fmosphetie pressure: 50 10 1064 Classification ‘lass Ian internally powered equipment, Type CFE, IPXI 1dr prootl Fuse TIA External dimentions Aprox 320NWini T6INT39/OInm ‘Weight Approx. 2.269 ‘Accessories AAC power source cord 1/ Operation GuideT “Options TOP Pate Clamp/TQ? Infusion StandExternal DC power source cord Communication ce @ Product specricatons and appearance ave subject to change wthout prior notice ai Tor ‘TOP Corporation 18-10, Senjunakatcho, Adacnisu, Tayo 120.0035, Japan Te 81Uapert3-38823101 Fax: 81lepanl-3-3681-8163 (02008 TOPCORFORATON VPOr81003 reed pan.

You might also like