InteliCompact-NT

Controllers designed
for simple and
multiple set
applications

1. Document information ................................................................... 3


2. Operator guide .............................................................................. 4

Copyright © 2016 ComAp a.s.


Prague, Czech Republic
ComAp a.s., U Uranie 1612/14a,

Operator Guide
170 00 Praha 7, Czech Republic
Tel: +420 246 0124 111
E-mail: [email protected], www.comap.cz
Table of contents
1. Document information ........................................................................................................ 3
1.1. Clarification of notation ........................................................................................................... 3
1.2. Conformity Declaration ........................................................................................................... 3
2. Operator guide ................................................................................................................... 4
2.1. Front panel elements ............................................................................................................. 4
2.2. User interface modes ............................................................................................................. 6
2.3. Display screens and pages structure ..................................................................................... 6
2.4. View measured values ........................................................................................................... 8
2.5. Setpoints - view and change .................................................................................................. 8
2.6. Browsing the history log ......................................................................................................... 9
2.7. Browsing alarms ................................................................................................................... 10
2.8. Entering the password ......................................................................................................... 11
2.9. Controller information screen ............................................................................................... 11
2.10. Controller language selection .............................................................................................. 13
2.11. User interface mode selection ............................................................................................. 13
2.12. Display contrast adjustment ................................................................................................. 13

InteliCompact-NT Operator Guide 2


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
1. Document information
INTELICOMPACT-NT® - OPERATOR GUIDE
W RITTEN BY: MICHAL SLAVATA AND REVISED BY: MILAN MATĚJKA
©2016 COMAP A.S.
U URANIE 1612/14A, PRAHA 7, CZECH REPUBLIC
PHONE: +420246012111
W EB: http://www.comap.cz, E-MAIL: [email protected]

DOCUMENT HISTORY
REVISION NUMBER RELATED SW. VERSION DATE

1 1.0 30.05.2008

2 1.1 28.02.2009

3 1.3.1 5.8.2011

4 2.1.0 16.8.2016

1.1. Clarification of notation


NOTE:
This type of paragraph calls readers attention to a notice or related theme.

CAUTION!
This type of paragraph highlights a procedure, adjustment etc., which can cause a damage or
unproper function of the equipment if not performed correctly and may not be clear at first sight.

WARNING!
This type of paragraph indicates things, procedures, adjustments etc. which need high level of
attention, otherwise can cause personal injury or death.

1.2. Conformity Declaration


The following described machine complies with the appropriate basic safety and
health requirement of the Low Voltage Directive No.: 2014/35/EU and
Electromagnetic Compatibility Directive 2014/30/EU based on its design and type, as
brought into circulation by us.

InteliCompact-NT Operator Guide 3


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
2. Operator guide
2.1. Front panel elements

Gen-set control buttons


POSITION DESCRIPTION
START button. Works in MAN mode only. Press this button to initiate the
1 start sequence of the engine. See the Reference Guide – “Engine start”
chapter to learn more about start sequence.
STOP button. Works in MAN mode only. Press this button to initiate the stop
sequence of the gen-set. Repeated pressing or holding the button for more
2 than 2s will cancel current phase of stop sequence (like ramping the power
down or cooling) and next phase will continue. See the Reference Guide –
“Engine cooldown and stop” chapter to learn more about stop sequence.
FAULT RESET button. Use this button to acknowledge alarms and
deactivate the horn output. Inactive alarms will disappear immediately and
3 status of active alarms will be changed to "confirmed" so they will disappear
as soon as their reasons dismiss. Learn more about alarms in the Reference
Guide – “Alarm management” chapter.

HORN RESET button. Use this button to deactivate the horn output without
4
acknowledging the alarms.

MODE LEFT button. Use this button to change the mode. The button works
only if the main screen with the indicator of currently selected mode is
5 displayed.

InteliCompact-NT Operator Guide 4


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
NOTE:
This button will not work if the controller mode is forced by one of binary
inputs listed in the Reference Guide – “Operating modes” chapter.
MODE RIGHT button. Use this button to change the mode. The button
works only if the main screen with the indicator of currently selected mode is
displayed.
6
NOTE:
This button will not work if the controller mode is forced by one of binary
inputs listed in the Reference Guide – “Operating modes” chapter.
GCB button. Works in MAN and TEST modes only. Press this button to
open or close the GCB. Note that certain conditions must be valid otherwise
7
GCB closing is blocked. See the Reference Guide – “Connecting to the load”
chapter for details.
MCB button. Works in MAN and TEST modes only. Press this button to
open or close the MCB manually.

NOTE:
8 Only in InteliCompact SPTM version.

CAUTION!
You can disconnect the load from the mains supply with this button! Be sure
you know well what you are about to do!

Gen-set operation indicators


POSITION DESCRIPTION
General alarm. This red indicator lights if at least one alarm is present in the alarm
9
list. It blinks if a new alarm has appeared and is still not acknowledged.
Gen-set voltage OK. This green indicator lights if the generator voltage and
frequency are in limits.
10
NOTE:
The limits for the generator voltage and frequency are given by setpoints located
in the Gener Protect group.
GCB position. This green indicator blinks if the forward “passive synchronizing” is
11 currently in progress; otherwise it shows current status of the generator circuit breaker
according to the feedback input.
12 Bus under voltage. This green indicator shows if the bus is under voltage or not.
MCB position. This green indicator blinks if the “passive synchronizing” is currently in
progress; otherwise it shows current status of the mains circuit breaker according to
the feedback input.
13
NOTE:
Only in InteliCompact SPTM version.
Mains voltage OK. This green indicator lights if the mains is evaluated as healthy.
See the Reference guide – “AMF function” chapter for details about mains evaluation.
14
NOTE:
Only in InteliCompact SPTM version.
Mains failure. This red indicator lights when the mains failure is detected and after
the gen-set has started and is about to take the load it lights permanently until the
mains failure disappears.
15
NOTE:
Only in InteliCompact SPTM version.

InteliCompact-NT Operator Guide 5


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
Display and display control buttons
POSITION DESCRIPTION
16 Graphic B/W display, 128x64 pixels

PAGE button. Use this button to switch over display pages. See next
17
chapter for details about display pages and screens structure

18 UP button. Use this button to move up or increase value.

19 DOWN button. Use this button to move down or decrease value.

ENTER button. Use this button to finish editing a setpoint or moving right in
20
the history page.

2.2. User interface modes


There are two modes of the user interface:

 User mode allows the user to go through all screens with measurements and alarms. The

button does not work, i.e. setpoints and history pages are not accessible.
 Engineer mode gives the qualified person full access to all pages and screens.

See the chapter “User interface mode selection” in Reference Guide to learn how to switch the user
interface mode.

2.3. Display screens and pages structure


The displayed information is structured into "pages" and "screens". Use PAGE button to switch over
the pages.

1. The page Measurement consists of screens which display measured values like voltages,
current, oil pressure etc., computed values like i.e. gen-set power, statistic data and the alarm
list on the last screen.
2. The page Setpoints contains all setpoints organized to groups and also a special group for
entering password.
3. The page History log shows the history log in the order that the last record is displayed first.

NOTE:
The picture below shows the structure of displayed data. The contents of each particular screen may
be slightly different according to the firmware branch and version.

InteliCompact-NT Operator Guide 6


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
Structure of the displayed data (basic)

InteliCompact-NT Operator Guide 7


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
2.4. View measured values

Press button repeatedly until you see the main screen with the kW meter and mode selector.

Then press or to select a requested screen within the measurement page.

Main screen

2.5. Setpoints - view and change

1. Press button repeatedly until you see a screen with a list of setpoint groups. Then select

desired group by pressing the or buttons and finally press button to


continue into the selected group.
2. Now you will see the list of setpoints which belong to the selected group together with their

current setting. Use the or buttons again to select the setpoint you want to modify

and press .
3. The current value of the setpoint will appear in the right part under the setpoint name and you

can change it by pressing or buttons. The rate of changing the value will
accelerate when the button is held down

4. Press button to confirm the change or to discard it and return to the list of
setpoints of the selected group.

5. Continue with change of another setpoint or press to return to the list of groups.

InteliCompact-NT Operator Guide 8


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
List of groups of setpoints

List of setpoints within selected group

Editing a setpoint

2.6. Browsing the history log

1. Press button repeatedly until you see the main history log screen with the reason
column and the latest record.

NOTE:
The records are numbered in reverse order, i.e. the latest (newest) record is "0" and older
records have "-1", "-2" etc.

2. Use the button to move over columns within the selected record. Pressing it repeatedly
will move cyclically through the columns, i.e. after last column the first one will be displayed.

3. Use buttons and to move over the records.

4. Press button to select another display page.

InteliCompact-NT Operator Guide 9


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
Main history log screen

NOTE:
The first history record after the controller is switched on, programmed or watchdog reset occurs
contains diagnostic values instead of operational. Some fields in these records seem to have
nonsense values. Do not take these values into account.

2.7. Browsing alarms


The Alarmlist and ECU Alarmlist are displayed on the last two screens in the measurement page. If
the main screen is displayed then the Alarmlist screen will appear automatically always when a new
alarm occurs. It can be also displayed manually as described in the chapter “View measured values”
in Reference Guide.

 Use the to move over the alarms in the ECU Alarmlist. Details of the selected alarm are
displayed in the bottom line.

 Press button to reset alarms.

 Active alarms are displayed as white text on black background. It means the alarm is stil
active, i.e. the appropriate alarm conditions are still present.
 Inactive alarms are displayed as black text on white background. It means the alarm is no
more active, i.e. the appropriate alarm conditions are gone.
 Not confirmed alarms are displayed with an asterisk. It means the alarm is still not
acknowledged (confirmed).

ALARMLIST

InteliCompact-NT Operator Guide 10


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
ECU AlarmList

NOTE:
The ECU AlarmList is visible only if an ECU is configured.

2.8. Entering the password


The password must be entered prior adjusting setpoints that are password-protected. Password is
located in the first group of setpoints and the way how to enter or change password is similar to
change of setpoints as described in the “Setpoints” chapter in Reference Guide.
NOTE:
It is possible to change only passwords of the same or lower level than actually entered password!

NOTE:
Lost password? Display the information screen which contains the serial number and a password
decode number as is described in the chapter below. Write down both numbers and send a request to
retrieve the password to your local ComAp distributor containing these two numbers. You can also
save and send an archive instead.

2.9. Controller information screen

1. Press the button repeatedly until you will see the main controller screen with the mode
selector and kW analog meter.

2. Hold down the button and simultaneously press the button to see the controller
information screen.
3. The information screen will disappear automatically after 5 secs

4. Press the button again within 5s to switch to language selection screen.

5. Press the button again to switch to the user interface mode selection screen. This
screen also contains serial number and password decode number.

6. Next pressing of the button switches back to the information screen.

7. Press the button to get back to the controller main screen.

InteliCompact-NT Operator Guide 11


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
Structure of the displayed data (advance)

The information screen contains following information:

 Controller Name
 Firmware identification string
 Serial number of the controller
 ESF version
 Firmware version, application version
 Application type
 Branch name

NOTE:
ESF version is shown only when electronic engine is configured.

InteliCompact-NT Operator Guide 12


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF
2.10. Controller language selection
There are two languages available in the controller. Default languages are English and Chinese. The
languages can be changed or modified during the configuration in LiteEdit. Please see the LiteEdit
documentation for details.
To switch the controller language:

1. Display the information screen as described above.

2. While the information screen is still displayed, press the button.

3. Language menu will appear, use or buttons to select the desired language.

4. Press to confirm the selection.

2.11. User interface mode selection


To switch the User interface mode, follow instructions below:

1. Display the information screen as described above.

2. While the information screen is still displayed, press the button twice.

3. User interface mode menu will appear, use or buttons to select the desired mode
(User or Engineer).

4. Press to confirm the selection.

2.12. Display contrast adjustment

1. Press the button repeatedly until you will see the main controller screen with the mode
selector and kW analog meter.

2. Hold down the button and simultaneously press button or repeatedly to


increase or decrease the contrast.

InteliCompact-NT Operator Guide 13


INTELICOMPACT-NT, SW VERSION 1.3, ©COMAP – SEPTEMBER 2011 REFERENCE GUIDE.PDF