Transformer MCQs
Transformer MCQs
Answer: Option C
Answer: Option A
Q3. If the percentage impedances of the two transformers working in parallel are different, then
D. parallel operation will still be possible, but the power factors at which the two transformers operate will be different
from the power factor of the common load
Answer: Option D
Q4. An ideal transformer will have maximum efficiency at a load such that
Answer: Option A
2
Q5. A Buchholz relay can be installed on
A. auto-transformers
B. air-cooled transformers
C. welding transformers
Answer: Option D
Q6. The full-load copper loss of a transformer is 1600 W. At half-load, the copper loss will be
A. 6400 W
B. 1600 W
C. 800 W
D. 400 W
Answer: Option D
A. frequency
Answer: Option D
Q8. A transformer cannot raise or lower the voltage of a D.C. supply because
C. Faraday's laws of electromagnetic induction are not valid since the rate of change of flux is zero
Answer: Option C
Q9. Which of the following loss in a transformer is zero even at full load?
A. Core loss
2
B. Friction loss
C. Eddy current loss
D. Hysteresis loss
Answer: Option B
Q10. Part of the transformer which is most subject to damage from overheating is
A. iron core
B. copper winding
C. winding insulation
D. frame or case
Answer: Option C
The no-load current drawn by transformer is usually what per cent of the full-load current?
Answer: Option B
The chemical used in breather for transformer should have the quality of
A. ionizing air
B. absorbing moisture
Answer: Option B
D. to take care of the expansion and contraction of transformer oil due to variation of temper-ature of sur-roundings
2
Answer: Option D
The function of breather in a transformer is
D. to arrest flow of moisture when outside air enters the transformer
Answer: Option D
Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is
likely to result in
B. power factor of one of the transformers is leading while that of the other lagging
C. transformers having higher copper losses will have negligible core losses
Answer: Option D
A. average value
B. r.m.s. value
C. maximum value
D. instantaneous value
Answer: Option C
In a given transformer for given applied voltage, losses which remain constant irrespective of load changes are
B. copper losses
Answer: Option C
The changes in volume of transformer cooling oil due to variation of atmospheric tem-perature during day and night
is taken care of by which part of transformer
2
A. Conservator
B. Breather
C. Bushings
D. Buchholz relay
Answer: Option A
Answer: Option B
Answer: Option C
A. zero
B. 10 Q
C. 1000 Q
D. infinity
Answer: Option D
Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds
A. 50°C
B. 80°C
C. 100°C
2
D. 150°C
Answer: Option D
For given applied voltage, with the increase in frequency of the applied voltage
Answer: Option C
In an actual transformer the iron loss remains practically constant from noload to fullload because
Answer: Option C
A. asbestos fiber
B. silica sand
C. sodium chloride
D. silica gel
Answer: Option D
Answer: Option A
2
If the supply frequency to the transformer is increased, the iron loss will
A. not changes
B. decrease
C. increase
Answer: Option C
B. compound generators
C. series motors
D. induction motors
Answer: Option D
Minimum voltage regulation occurs when the power factor of the load is
A. unity
B. lagging
C. leading
D. zero
Answer: Option C
A. 33 kV
B. 66 kV
C. 132 kV
D. 400 kV
Answer: Option D
The secondary winding of which of the following transformers is always kept closed?
A. Step-up transformer
B. Step-down transformer
2
C. Potential transformer
D. Current transformer
Answer: Option D
Answer: Option A
The transformer oil should have _____ volatility and _____ viscosity.
A. low, low
B. high, high
C. low, high
D. high, low
Answer: Option A
A. tightness of clamping
B. gauge of laminations
C. size of laminations
Answer: Option D
A. 0.4 mm to 0.5 mm
B. 4 mm to 5 mm
C. 14 mm to 15 mm
D. 25 mm to 40 mm
Answer: Option A
2
The core used in high frequency transformer is usually
A. copper core
C. air core
Answer: Option C
A transformer transforms
A. voltage
B. current
C. power
D. frequency
Answer: Option C
A. zero
B. 1 ohm
C. 1000 ohms
D. infinite
Answer: Option D
A. on full-load
B. on overload
Answer: Option C
D. no load
Answer: Option A
A. Bmax
B. Bmax1-6
C. Bmax1-83
D. B max
Answer: Option B
The no load current in a transformer lags behind the applied voltage by an angle of about
A. 180°
B. 120°
C. 90°
D. 75°
Answer: Option D
The efficiency of two identical transformers under load conditions can be determined by
A. short-circuit test
B. back-to-back test
Answer: Option B
For a transformer, operating at constant load current, maximum efficiency will occur at
Answer: Option D
Helical coils can be used on
Answer: Option A
Answer: Option A
Answer: Option B
C. Primary winding
D. Secondary winding
Answer: Option A
A. mica strip
2
Answer: Option B
Answer: Option A
If R₂ is the resistance of secondary winding of the transformer and K is the transformation ratio then the equivalent
secondary resistance referred to primary will be
A. R₂/√K
B. R₂/K²
C. R₂²/K²
D. R₂²/K
Answer: Option B
Two transformers operating in parallel will share the load depending upon their
A. leakage reactance
C. efficiencies
D. ratings
Answer: Option B
A. Frequency
B. Voltage
C. Current
Answer: Option A
When a given transformer is run at its rated voltage but reduced frequency, its
Answer: Option D
A. Current
B. Voltage
C. Frequency
Answer: Option C
A. low
B. negligible
Answer: Option A
While conducting short-circuit test on a transformer the following side is short circuited
C. Primary side
D. Secondary side
Answer: Option B
Answer: Option C
A. core
B. windings
C. tank
Answer: Option B
The primary coil of a transformer is connected to a 60 V ac source. The secondary coil is connected to a 330 Ω load.
The turns ratio is 3:1. What is the secondary voltage?
A. 2 V
B. 20 V
C. 180 V
D. 18 V
Answer: Option B
Answer: Option A
A transformer has a 1:6 turns ratio and a secondary coil load resistance of 470 Ω. The load resistance as seen by the
source is
A. 1.3 Ω
B. 7.8 Ω
C. 78 Ω
2
D. 13 Ω
Answer: Option D
A. primary side
B. secondary side
Answer: Option D
Answer: Option A
Answer: Option C
Which of the following is not the standard voltage for power supply in India?
A. 11 kV
B. 33kV
C. 66 kV
D. 122 kV
Answer: Option D
2
When the equivalent circuit diagram of doouble squirrelcage induction motor is constructed the two cages can be
considered
A. in series
B. in parallel
C. in series-parallel
Answer: Option B
An ideal transformer has infinite values of primary and secondary inductances. The statement is
A. true
B. false
Answer: Option B
Answer: Option A
B. Impedance test
D. Polarity test
Answer: Option C
The efficiencies of transformers compared with that of electric motors of the same power are
B. much smaller
C. much higher
D. somewhat smaller
2
Answer: Option C
The noise resulting from vibrations of laminations set by magnetic forces, is termed as
A. Magnetostriction
B. Boo
C. Hum
D. Zoom
Answer: Option C
A. voltage device
B. current device
C. power device
Answer: Option D
A. temperature
B. stray losses
C. all-day efficiency
Answer: Option A
For the parallel operation of single phase transformers, it is necessary that they should have
A. same efficiency
B. same polarity
Answer: Option B
A. supply frequency
2
B. load current
C. power factor of load
Answer: Option D
A. copper loss
B. magnetizing current
Answer: Option C
A. 1 kV
B. 33 kV
C. 100 kV
D. 330 kV
Answer: Option B
A. sludge
B. odour
C. gases
D. moisture
Answer: Option D
Losses which occur in rotating electric machines and do not occur in trans formers are
B. magnetic losses
D. copper losses
2
Answer: Option A
Which of the following is the main advantage of an auto-transformer over a two-winding transformer?
Answer: Option B
Answer: Option C
A. capacitive only
B. inductive only
C. inductive or resistive
Answer: Option A
Which motor is preferred for use in mines where explosive gases exist?
A. Air motor
B. Induction motor
C. Shunt motor
D. Synchronous motor
Answer: Option A
A. Circular type
2
B. Sandwich type
C. Cylindrical type
D. Rectangular type
Answer: Option B
A. load changes
C. magnetostriction
D. mechanical vibrations
Answer: Option C
Answer: Option A
A. special test
B. routine test
C. type test
Answer: Option C
A. high loads
Answer: Option D
Open circuit test on transformers is conducted to determine
A. hysteresis losses
B. copper losses
C. core losses
Answer: Option C
A. hysteresis losses
B. copper losses
C. core losses
Answer: Option B
In a certain transformer, the input power to the primary is 120 W. If 8.5 W are lost to the winding resistance, what is
the output power to the load, neglecting any other issues?
A. 0 W
B. 14.1 W
C. 111.5 W
D. 1,020 W
Answer: Option C
Which of the following acts as a protection against high voltage surges due to lightning and switching?
A. Horn gaps
C. Breather
D. Conservator
Answer: Option A
The power factor of an induction motor under no-load conditions will be closer to
A. 0.2 lagging
2
B. 0.2 leading
C. 0.5 leading
D. unity
Answer: Option A
Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is
Answer: Option A
A. high resistance
B. high reluctance
C. low resistance
D. low reluctance
Answer: Option D
A. high reluctance
B. low reactance
C. high resistance
D. low resistance
Answer: Option B
The permissible flux density in case of cold rolled grain-oriented steel is around
A. 1.7 Wb/m²
B. 2.7 Wb/m²
C. 3.7 Wb/m²
D. 4.7 Wb/m²
2
Answer: Option A
No-load current of a transformer has
Answer: Option D
In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of
A. less than 15 A
B. more than 15 A
C. 15 A
Answer: Option A
Answer: Option A
The secondary of a current transformer is always short-circuited under operating conditions because it
Answer: Option A
A. proper ventilation
2
D. having number of rotor slots more or less than the number of stator slots (not equal)
Answer: Option D
A. Conservator
B. Breather
C. Buchholz relay
D. Exciter
Answer: Option D
A. Primary winding
B. Secondary winding
Answer: Option D
The complete circle diagram of induction motor can be drawn with the help of data found from
A. no-load test
Answer: Option D
C. oil cooling
Answer: Option C
An open-circuit test on a transformer is conducted primarily to measure
A. insulation resistance
B. copper loss
C. core loss
D. total loss
Answer: Option C
B. through air
Answer: Option C
Answer: Option C
C. frequency meter
Answer: Option A
Answer: Option B
Which of the following property is not necessarily desirable in the material for transformer core?
A. Mechanical strength
D. High permeability
Answer: Option C
Which of the following properties is not necessarily desirable for the material for transformer core?
B. High permeability
Answer: Option C
A. 1.5 MVA
B. 5 MVA
C. 15 MVA
D. 50 MVA
Answer: Option A
Reduction in core losses and increase in permeability are obtained with transformer employing
Answer: Option A
Harmonics in transformer result in
Answer: Option D
Answer: Option A
In a power or distribution transformer about 10 per cent end turns are heavily insulated
A. to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns
B. to absorb the line surge voltage and save the winding of transformer from damage
C. to reflect the line surge and save the winding of a transformer from damage
Answer: Option A
C. Primary winding
D. Secondary winding
Answer: Option B
What will happen if the transformers working in parallel are not connected with regard to polarity?
A. The power factor of the two transformers will be different from the power factor of common load
2
Answer: Option B
A. load on it increases
B. load on it decreases
Answer: Option B
A. wood
B. copper
C. aluminium
D. silicon steel
Answer: Option D
A. 3000 kVA
B. 1000 kVA
C. 500 kVA
D. 250 kVA
Answer: Option A
The maximum load that a power transformer can carry is limited by its
A. temperature rise
C. voltage ratio
D. copper loss
2
Answer: Option C
Which of the following is the most likely source of harmonics in a transformer?
A. poor insulation
B. Overload
C. loose connections
D. Core saturation
Answer: Option D
A. load current
Answer: Option A
A. zoom
B. hum
C. ringing
D. buzz
Answer: Option B
A. core loss
B. copper loss
C. efficiency
D. magnetizing current
Answer: Option E
A. Bushings
B. Core
C. Primary winding
D. Secondary winding
Answer: Option A
Answer: Option A
Which of the following insulating materials can withstand the highest temperature safely?
A. Cellulose
B. Asbestos
C. Mica
D. Glass fibre
Answer: Option C
C. starting the motor on load which is more than the rated load
Answer: Option D
A. fluctuating load
B. poor insulation
C. mechanical vibrations
2
D. saturation of core
Answer: Option D
A. hot because of heavy iron losses taking place in it due to high flux density
Answer: Option A
Answer: Option A
Answer: Option B
In Ns is the synchronous speed and s the slip, then actual running speed of an induction motor will be
A. Ns
B. s.N.
C. (l-s)Ns
D. (Ns-l)s
Answer: Option C
2
B. Zero load
C. 25% load
D. 50% load
Answer: Option D
A. no-load
B. half-load
C. near full-load
D. 10% overload
Answer: Option C
Which of the following statements regarding an idel single-phase transformer having a turn ratio of 1 : 2 and drawing
a current of 10 A from 200 V A.C. supply is incorrect?
Answer: Option D
A. at no load
Answer: Option B
Which of the following protection is normally not provided on small distribution transformers?
B. Buchholz relay
2
C. Overcurrent protection
D. All of the above
Answer: Option B
Answer: Option D
Answer: Option D
A. volts
B. amperes
C. kW
D. kVA
Answer: Option D