0% found this document useful (0 votes)
300 views3 pages

LPG Cylinder Filling Plant Machines Utility Reuirements

This document outlines the utility requirements for various machines used in an LPG cylinder filling plant, including chain conveyors, roller conveyors, tare weight encoding systems, pneumatic admission systems, carousels, filling scales, check scales, resetting check scales, controlling units, automatic valve and o-ring detectors, thermo-shrinkable sleeve machines, LPG pressure regulating skids, and manual o-ring leak testers. The utilities required include electricity ranging from 12V to 400V, compressed air, and LPG, with specified flow rates and connection details provided for each machine component.

Uploaded by

Kamal Deshapriya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
300 views3 pages

LPG Cylinder Filling Plant Machines Utility Reuirements

This document outlines the utility requirements for various machines used in an LPG cylinder filling plant, including chain conveyors, roller conveyors, tare weight encoding systems, pneumatic admission systems, carousels, filling scales, check scales, resetting check scales, controlling units, automatic valve and o-ring detectors, thermo-shrinkable sleeve machines, LPG pressure regulating skids, and manual o-ring leak testers. The utilities required include electricity ranging from 12V to 400V, compressed air, and LPG, with specified flow rates and connection details provided for each machine component.

Uploaded by

Kamal Deshapriya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

LPG CYLINDER FILLING PLANT MACHINES UTILITY REUIREMENTS

1. CHAIN CONVEYORS.
 Made of a galvanized steel frame.
 CC600 cast iron chain is used.
 Electricity - Cable glands of each explosion proof electrical motor.
 Conveyor - Including all conveyor legs and concrete plug.

2. ROLLER CONVEYOR.
 Made of a galvanized steel frame.
 Galvanized steel rollers 50(diameter).
 Thickness 3 mm.
 Axes 12(diameter) (18 roller per meter).
 Each roller is equipped with balls bearings.
 Conveyor legs are included when it is not embedded to the concrete.

3. TARE WEIGHT ENCODING SYSTEM.

Consumptions.
 Air : 6,2 N liters / cylinder *4
 Electricity : 12V, 100mA max. (According To power supply 85-264VAC, 47-440HZ)

4. TANGEANTIAL PNEUMATIC ADMISSION.

Consumptions.
 Air : 0,04Nm3/cylinders with air pressure set at 6bars.
 Air : Quick drain valve of the air regulator - Ø1/2".

5. CAROUSEL SYSTEM

Consumptions.
 Air : Depends of the filling machines numbers used
 LPG : Depends of the filling machines numbers used
 Electricity 400Vac : 1,1kW.
 Electricity 230Vac : Maximum 0,8kW.
Limit of supply.
 Air : Male connection Ø1" – Gas type
 LPG : Counter flange – Ø3" ANSI 300
 Electricity 400Vac : Cable gland of the driving unit.
 Electricity 230Vac : Cable gland of the power supply.
6. ELECTRONIC FILLING SCALE ON CAROUSEL

Consumptions.
 Electricity : 12V, 100mA max. According to power supply 85264VAC,47-440HZ
 Air : 0.015Nm3 maximum per filling cycle.
Limits of supply.
 Air : Isolating valve - Ø1/4".
 Electricity : Electrical plug.
 LPG : Isolating valve Ø1/2".

7. ELECTRONIC CHECK SCALE.

Consumptions.
 Air : 7 Normal liters / cylinder with air pressure set at 6bars.
 Electricity : 12V, 100mA max. According to SIRAGA power supply 85264VAC, 47-
440HZ.
Limit of supply.
 Air : See technical description of Power Supply Panel.
 Electricity : See technical description of Power Supply Panel.

8. ELECTRONIC RESETTING CHECK SCALE.

Consumptions.
 Electricity : 12V, 100mA max. According to SIRAGA power supply 85264VAC,47
440HZ
 Air : 0.005Nm maximum per filling cycle.
Limit of supply.
 Air : See the power supply panel
 Electricity :See the power supply panel
 LPG :2 LPG flexible pipe, l=1.2 m, with isolating valve Ø ½" NPT

9. CONTROLLING UNIT.

Limit of consumptions.
 Air : Quick drain valve of the air regulator - Ø1/2".
 Electricity : Cable gland of the electrical power transformer.
Utilities.
 Air : See the description of the filling machine.
 Electricity : 0, 3 kW – 230 Vac (50 Hz).
10. AUTOMATIC VALVE LEAK + ORING DETECTOR.

Consumptions.
 Air : 0,015 Nm3 / cylinder with air pressure set at 6bars.
 Electricity : 230V, 50Hz.....: 0, 3 kW.
Limit of supply
 Air : Quick drain valve of the air regulator - Ø1/2".
 Electricity : Cable gland of power supply.

11. AUTOMATIC THERMO-SHRINKABLE SLEEVES MACHINE 1 HEAD.

Limit of supply.
 Air : Quick drain valve of the air regulator - Ø1/2".
 Elec : Cable gland of the electrical explosion proof control panel.
Consumptions.
 Air : 2, 4 Normal liters / cylinder with air pressure set at 6bars.
 Elec : 6,18Kw.

12. LPG PRESSURE REGULATING SKID

Limit of supply
 LPG inlet. : Counter-flanges Ø 3” PN40 RF.
 LPG return line. : Counter-flanges Ø 2" PN40 RF.
 LPG outlet : Counter-flanges Ø 3" PN40 RF.
 Radiography : 10%.

13. MANUAL ORING LEAK TESTER DUAL HEADS

Limit of supply
 Compressed air : quick drain valve for the air regulator -Ø1/2"
Standard performances.
 Leak sensitivity : 0.5 g of LPG
Special requirements.
 Installation : on conveyor
 Conveyor : chain conveyor (level=+480mm)
 Cylinder stop unit : 2