You are on page 1/ 6

SOL AR INVERTERS

ABB string inverters


UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q
1.2 to 5.0 kW
The UNO-DM-TL-PLUS-Q
single-phase inverter family, with
power ratings from 1.2 to 5.0 kW, is
the optimal solution for residential
installations.

— One size fits all Vision® remote monitoring experience.


01
UNO-DM-TL-PLUS-Q The design wraps ABB’s quality and engineering into The advanced communication interfaces (WLAN,
outdoor string inverter a lightweight and compact package thanks to Ethernet, RS485) combined with an efficient
technological choices optimized for installations with Modbus (RTU/TCP) communication protocol,
different orientation. Sunspec compliant, allow the inverter to be easily
All power ratings share the same overall volume, integrated within any smart environment and with
allowing higher performance in a minimum space, third party monitoring and control systems.
and are available with both single (from 1.2 to 3.0 A complete set of control functions with the
kW models) and dual (from 3.3 to 5.0 kW models) embedded efficient algorithm, enabling dynamic
Maximum Power Point Trackers. control of the feed-in (i.e. zero injection), make the
inverter suitable for worldwide applications in
Easy to install, fast to commission compliance with regulatory norms and needs of the
The presence of Plug and Play connectors, both on utilities.
the DC and AC side, as well as the wireless
communication, enable a simple, fast and safe ABB Ability™ Energy Viewer for solar plants
installation without the need of opening the front This new tool allows residential customers to
cover of the inverter. remotely monitor the performance of their own
solar plant and provides all information necessary to
The featured easy commissioning routine removes increase energy self-reliance and self-sufficiency.
the need for a long configuration process, resulting
in lower installation time and costs. Highlights
Improved user experience thanks to the build in • Wireless access to the embedded Web User
User Interface (UI) or the Installer for Solar Interface
Inverters app which enable access to features such • Easy commissioning capability
as advanced inverter configuration settings, • Future-proof with embedded connectivity for
dynamic feed-in control and load manager, from smart building and smart grid integration
any WLAN enabled device (smartphone, tablet or PC). • Dynamic feed-in control (for instance “zero
injection”)
Smart capabilities • Remote firmware upgrade for inverter and
The embedded logging capabilities and direct components
transferring of the data to Internet (via Ethernet or • Modbus TCP/RTU Sunspec compliant
WLAN) allow customers to enjoy the whole Aurora • Lifetime free of charge access to Aurora Vision
P R O D U C T F LY E R F O R U N O - D M - 1 . 2 / 2 . 0/ 3 . 3/4 . 0/4 . 6/ 5 . 0 -T L - P L U S - Q A B B S O L A R I N V E R T E R S


ABB string inverters
UNO-DM-TL-PLUS-Q
1.2 to 5.0 kW


Technical data and types

Type code UNO-DM-1.2-TL-PLUS-Q UNO-DM-2.0-TL-PLUS-Q UNO-DM-3.0-TL-PLUS-Q UNO-DM-3.3-TL-PLUS-Q


Input side
Absolute maximum DC input voltage (Vmax,abs) 600 V
Start-up DC input voltage (Vstart) 120 V (adj. 100…150 V) 150 V (adj. 100…250 V) 150 V (adj. 100…250 V) 200 V (adj. 120...350 V)
Operating DC input voltage range
0.7 x Vstart ...580 V (min 90 V)
(Vdcmin ...Vdcmax)
Rated DC input voltage (Vdcr) 185 V 300 V 300 V 360 V
Rated DC input power (Pdcr) 1500 W 2500 W 3300 W 3500 W
Number of independent MPPT 1 1 1 2
Maximum DC input power for each MPPT
1500 W 2500 W 3300 W 2000 W
(P MPPTmax)
DC input voltage range with parallel
100…530 V 210...530 V 320...530 V 170...530 V
configuration of MPPT at Pacr
Linear derating from
DC power limitation with parallel configuration
N/A N/A N/A Max to Null [530
of MPPT
V≤VMPPT ≤580 V]
2000 W
DC power limitation for each MPPT with [200 V≤VMPPT≤530 V]
independent configuration of MPPT at Pacr, N/A N/A N/A the other channel:
max unbalance example Pdcr -2000 W
[112 V≤VMPPT≤530 V]
Maximum DC input current (I dcmax) /
10.0 A 10.0 A 10.0 A 20.0/10.0 A
for each MPPT (I MPPTmax)
Maximum input short circuit current for each
12.5 A 12.5 A 12.5 A 12.5 A
MPPT
Number of DC input pairs for each MPPT 1
DC connection type 1) Quick Fit PV Connector
Input protection
Reverse polarity protection Yes, from limited current source
Input over voltage protection for each MPPT-
Yes
varistor
Photovoltaic array isolation control According to local standard
DC switch rating for each MPPT
25 A / 600 V
(version with DC switch)
Output side
AC grid connection type Single-phase
Rated AC power (Pacr @cosφ=1 ) 1200 W 2000 W 3000 W 3300 W
Maximum AC output power (Pacmax @cosφ=1) 1200 W 2000 W 3000 W 3300 W
Maximum apparent power (S max) 1200 VA 2000 VA 3000 VA 3300 VA
Rated AC grid voltage (Vac,r) 230 V
AC voltage range 3) 180...264 V
Maximum AC output current (I ac,max) 5.5 A 10.0 A 14.5 A 14.5 A
Contributory fault current 10.0 A 12.0 A 16.0 A 16.0 A
Rated output frequency (fr) 4) 50/60 Hz
Output frequency range (fmin ...fmax) 4) 47...53/57...63 Hz
Nominal power factor and adjustable range > 0.995, adj. ± 0.1 - 1 (over/under excited)
Total current harmonic distortion < 3.5%
AC connection type Female connector from panel
Output protection
Anti-islanding protection According to local standard
Maximum external AC overcurrent protection 10.0 A 16.0 A 16.0 A 20.0 A
Output overvoltage protection - varistor 2 (L - N / L - PE)
P R O D U C T F LY E R F O R U N O - D M - 1 . 2 / 2 . 0/ 3 . 3/4 . 0/4 . 6/ 5 . 0 -T L - P L U S - Q A B B S O L A R I N V E R T E R S


ABB UNO-DM-1.2/2.0-TL-PLUS-Q string inverter block diagram

MPPT 1 Inverter Line Grid parallel


(DC/DC) Bulk caps (DC/AC) filter relay
+ + +
IN1(+) IN1(+) L

IN1 IN1 IN1

IN1(-) IN1(-) N
- - -

Standard version -S version


PE

Residual current
detection Optional
RS485
+ T/R
- T/R
RTN
DC/DC DC/AC
DSP DSP Remote control
contr. contr. +R
-R

Load manager/
µP Alarm
N.C
N.O
C

Control circuit

WLAN


Technical data and types

Type code UNO-DM-1.2-TL-PLUS-Q UNO-DM-2.0-TL-PLUS-Q UNO-DM-3.0-TL-PLUS-Q UNO-DM-3.3-TL-PLUS-Q


Operating performance
Maximum efficiency (ηmax) 94.8% 96.7% 96.7% 97.0%
Weighted efficiency (EURO/CEC) 92.0%/- 95.0%/- 90.0%/- 96.5% / -
Feed in power threshold 8W
Night consumption <0.4 W
Embedded communication
Embedded communication interface 5) Wireless
Embedded communication protocol ModBus TCP (SunSpec)
Commissioning tool Web User Interface, Aurora Manager Lite
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile,
Monitoring
ABB Ability™ Energy Viewer for solar plants
Optional board UNO-DM-COM kit
Optional communication interface RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus RTU (SunSpec), Aurora Protocol
Optional board UNO-DM-PLUS Ethernet COM kit
Ethernet, RS485 (use with meter for dynamic feed-in control),
Optional communication interface
Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol
Environmental
-25...+60°C /-13...140°F -25...+60°C /-13...140°F -25...+60°C/-13...140°F -25...+60°C /-13...140°F
Ambient temperature range with derating above with derating above con derating sopra with derating above
50°C/122°F 50°C/122°F 50°C/122°F 50°C/122°F
Relative humidity 0...100 % condensing
Acoustic noise emission level 50 dBA @ 1 m
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 553 x 418 x 175 mm / 21.8” x 16.5” x 6.9”
Weight 15 kg / 33 lbs
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE , RCM
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1,EN 61000-6-2, EN 61000-
Safety and EMC standard
6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3
Grid standard CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 413, ITC-BT-40,
(check your sales channel for availability) 7) AS/NZS 4777.2, IEC 61727, IEC 62116
Available products variants
Standard UNO-DM-1.2-TL-PLUS-B-Q UNO-DM-2.0-TL-PLUS-B-Q UNO-DM-3.0-TL-PLUS-B-Q UNO-DM-3.3-TL-PLUS-B-Q
With DC switch UNO-DM-1.2-TL-PLUS-SB-Q UNO-DM-2.0-TL-PLUS-SB-Q UNO-DM-3.0-TL-PLUS-SB-Q UNO-DM-3.3-TL-PLUS-SB-Q

1)
“Refer to the document “String inverter – Product Manual appendix” available at 4)
The Frequency range may vary depending on specific country grid standard;
www.abb.com/solarinverters to know the brand and the model of the quick fit CE is valid for 50Hz only
connector” 5)
As per IEEE 802.11 b/g/n standard
2)
For UK G83/2 setting, maximum output current limited to 16 A up to a maximum output 6)
Pacr = 4200 W @ 45°C/113°F
Pacr of 3600 W and a maximum apparent power of 3600 VA 7)
Further grid standard will be added, please refer to ABB Solar page for further details
3)
The AC voltage range may vary depending on specific country grid standard Remark. Features not specifically listed in the present data sheet are not included in the
product
P R O D U C T F LY E R F O R U N O - D M - 1 . 2 / 2 . 0/ 3 . 3/4 . 0/4 . 6/ 5 . 0 -T L - P L U S - Q A B B S O L A R I N V E R T E R S


UNO-DM-PLUS-Q:
Efficient, connected, smart.


Technical data and types

Type code UNO-DM-4.0-TL-PLUS-Q UNO-DM-4.6-TL-PLUS-Q UNO-DM-5.0-TL-PLUS-Q


Input side
Absolute maximum DC input voltage (Vmax,abs) 600 V
Start-up DC input voltage (Vstart) 200 V (adj. 120...350 V)
Operating DC input voltage range (Vdcmin ...Vdcmax) 0.7 x Vstart ...580 V (min 90 V)
Rated DC input voltage (Vdcr) 360 V
Rated DC input power (Pdcr) 4250 W 4750 W 5150 W
Number of independent MPPT 2
Maximum DC input power for each MPPT (P MPPTmax) 3000 W 3000 W 3500 W
DC input voltage range with parallel configuration
130...530 V 150...530 V 170....480 V
of MPPT at Pacr
DC power limitation with parallel configuration Linear derating from Max to Linear derating from Max to Linear derating from Max to
of MPPT Pacr Null [530V≤VMPPT ≤580V] Null [530V≤VMPPT ≤580V] Null [480V≤VMPPT ≤580V]
On MPPT 1: 3500 W
[185 V≤VMPPT ≤480 V]
DC power limitation for each MPPT with 3000 W [190 V≤VMPPT ≤530 V] 3000 W [190 V≤VMPPT ≤530 V]
On MPPT 2: Pdcr -3500 W
independent configuration of MPPT at Pacr, the other channel: Pdcr -3000 W the other channel: Pdcr -3000 W
[145 V≤VMPPT ≤480 V] or
max unbalance example [90 V≤VMPPT ≤530 V] [90 V≤VMPPT ≤530 V]
3500 W (305 V≤VMPPT ≤480 V)
with no power on MPPT1
Maximum DC input current (I dcmax) / 30.5/19-11.5
32.0/16.0 A 32.0/16.0 A
for each MPPT (I MPPTmax) (MPPT 1 - MPPT 2)
Maximum input short circuit current for each MPPT 20.0 A 20.0 A 22.0 A
Number of DC input pairs for each MPPT 1
DC connection type 1) Quick Fit PV Connector
Input protection
Reverse polarity protection Yes, from limited current source
Input over voltage protection for each MPPT-
Yes
varistor
Photovoltaic array isolation control According to local standard
DC switch rating for each MPPT
25 A / 600 V
(version with DC switch)
Output side
AC grid connection type Single-phase
Rated AC power (Pacr @cosφ=1 ) 4000 W 4600 W 5000 W
Maximum AC output power (Pacmax @cosφ=1) 4000 W 2) 4600 W 5000 W
Maximum apparent power (S max) 4000 VA 2) 4600 VA 5000 VA
Rated AC grid voltage (Vac,r) 230 V
AC voltage range 3) 180...264 V
Maximum AC output current (I ac,max) 17.2 A 20.0 A 22.0 A
Contributory fault current 19.0 A 22.0 A 24.0 A
Rated output frequency (fr) 4) 50/60 Hz
Output frequency range (fmin ...fmax) 4) 47...53/57...63 Hz
Nominal power factor and adjustable range > 0.995, adj. ± 0.1 - 1 (over/under excited)
Total current harmonic distortion < 3.5
AC connection type Female connector from panel
Output protection
Anti-islanding protection According to local standard
Maximum external AC overcurrent protection 25.0 A 25.0 A 32.0 A
Output overvoltage protection - varistor 2 (L - N / L - PE)
P R O D U C T F LY E R F O R U N O - D M - 1 . 2 / 2 . 0/ 3 . 3/4 . 0/4 . 6/ 5 . 0 -T L - P L U S - Q A B B S O L A R I N V E R T E R S


ABB UNO-DM-3.3/4.0/4.6/5.0-TL-PLUS-Q string inverter block diagram

MPPT 1 Inverter
(DC/DC) Bulk caps (DC/AC)
+ + +
IN1.1(+) IN1.1(+) Line Grid parallel
filter relay
IN1 IN1 IN1
L

IN1.1(-) IN1.1(-)
- - -
N

MPPT 2
(DC/DC)
+ + +
IN2.1(+) IN2.1(+)
PE
IN2 IN2 IN2

Residual current Optional


IN2.1(-) IN2.1(-) detection
- - -
RS485
+ T/R

Standard version -S version - T/R


RTN

DC/DC DC/AC
DSP DSP Remote control
contr. contr.
+R
-R

µP Load manager/
Alarm
N.C
N.O
C
Control circuit
WLAN


Technical data and types

Type code UNO-DM-4.0-TL-PLUS-Q UNO-DM-4.6-TL-PLUS-Q UNO-DM-5.0-TL-PLUS-Q


Operating performance
Maximum efficiency (ηmax) 97.0% 97.0% 97.4%
Weighted efficiency (EURO/CEC) 96.5% / - 96.5% / - 97.0% / -
Feed in power threshold 8W
Night consumption <0.4 W
Embedded communication
Embedded communication interface 5) Wireless
Embedded communication protocol ModBus TCP (SunSpec)
Commissioning tool Web User Interface, Aurora Manager Lite
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile,
Monitoring
ABB Ability™ Energy Viewer for solar plants
Optional board UNO-DM-COM kit
Optional communication interface RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus RTU (SunSpec), Aurora Protocol
Optional board UNO-DM-PLUS Ethernet COM kit
Ethernet, RS485 (use with meter for dynamic feed-in control),
Optional communication interface
Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol
Environmental
-25...+60°C /-13...140°F with -25...+60°C /-13...140°F with -25...+60°C /-13...140°F with
Ambient temperature range
derating above 50°C/122°F derating above 45°C/113°F 6) derating above 45°C/113°F
Relative humidity 0...100 % condensing
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 553 x 418 x 175 mm / 21.8” x 16.5” x 6.9”
Weight 15 kg / 33 lbs
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE , RCM
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1, EN 61000-6-2,
Safety and EMC standard
EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
Grid standard CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 413,
(check your sales channel for availability) 7) ITC-BT-40, AS/NZS 4777.2, C10/11, IEC 61727, IEC 62116
Available products variants
Standard UNO-DM-4.0-TL-PLUS-B-Q UNO-DM-4.6-TL-PLUS-B-Q UNO-DM-5.0-TL-PLUS-B-QU
With DC switch UNO-DM-4.0-TL-PLUS-SB-Q UNO-DM-4.6-TL-PLUS-SB-Q UNO-DM-5.0-TL-PLUS-SB-QU

1)
“Refer to the document “String inverter – Product Manual appendix” available at CE is valid for 50Hz only
www.abb.com/solarinverters to know the brand and the model of the quick fit connector” 5)
As per IEEE 802.11 b/g/n standard
2)
For UK G83/2 setting, maximum output current limited to 16 A up to a maximum output 6)
Pacr = 4200 W @ 45°C/113°F
Pacr of 3600 W and a maximum apparent power of 3600 VA 7)
Further grid standard will be added, please refer to ABB Solar page for further details
3)
The AC voltage range may vary depending on specific country grid standard Remark. Features not specifically listed in the present data sheet are not included in the
4)
The Frequency range may vary depending on specific country grid standard; product
UNO-DM-TL-PLUS-Q-1.2/2.0/3.3/4.0/4.6/5.0-9AKK107046A8889 EN REV A 19.12.2018

— —
For more information please contact We reserve the right to make technical We reserve all rights in this document and
your local ABB representative or visit: changes or modify the contents of this in the subject matter and illustrations
document without prior notice. With contained therein. Any reproduction,
www.abb.com/solarinverters regard to purchase orders, the agreed disclosure to third parties or utilization of
particulars shall prevail. ABB AG does not its contents – in whole or in parts – is
www.abb.com accept any responsibility whatsoever for forbidden without prior written consent of
potential errors or possible lack of ABB AG. Copyright© 2018 ABB
information in this document. All rights reserved