Industrial Bimetal Thermometer Bottom Connection: Since 1971
Industrial Bimetal Thermometer Bottom Connection: Since 1971
Industrial Bimetal Thermometer Bottom Connection: Since 1971
Since 1971
Industrial Bimetal Thermometer
Bottom Connection
All SS construction HAWK BTL bottom connection thermometer
provides the same features as BTE series
External re-calibration adjustable angle bimetal thermometer, but
adjustment with a fixed lower(bottom) connection. It has
been designed specially to meet the needs
Open front/ of standard industrial applications and
removable ring
installations.
Hermetically sealed Our Bimetal thermometers are welded
case all stainless steel construction and are
hermetically sealed. These instruments are
Bottom, top, right, left, leak tested completely to insure the integrity
side mounting of the joints in the process of producing.
HAWK Supplies a wide selection of the
Field silicon fillable available temperature ranges from -50 C
o
for additional o o
dampening for extreme
to 550 C or equivalent in F.
vibration
BTL
Series
Typical Applications:
Medical and pharmaceutical industry Industrial OEM equipments Food and beverage processing
MIining industry Marine Industry Construction and agriculture equipments Refrigeration and
HVAC systems Pulp and paper mills Energy and water managements Dairly Military
Specifications:
Operating: Size: Pointer:
The temperature of the case should not be 2 1/2"(63mm), 3"(80mm), Anodized aluminum with black
allowed to be exposed to continuous 4"(100mm), 5"(125mm) or finish
temperature in excess of 200 oF(95 oC). If 6"(150mm)
Accuracy:
silicone filled, the temperature limit is Case&Ring: 1.0% of span
150 oF(65 oC). Stem and bulb should not be Stainless Steel 304(SS316-option), (Grade A to ASME B40.3)
contact with sustained process temperature polished bayonet ring
exceeding 50% over-range or 800 oF(425oC). Stem External Adjustment:
External re-calibartion on back
Immersion: 304 Stainless Steel, 1/4" diameter
-Standard, 3/8" or others dia available
For getting the correct temperature readings,
Scale:
the stem of all models in all ranges must be Dial Face o o
immersed 2" deep in liquid, and 4" deep in C, F(single or dual scale)
Aluminum, white background
gas except for 0/50 oC(32/122 oF) which with black graduations and figures,
require 3" deep in liquid, and 4" deep in gas. anti-parallax to minimize the Stem Length:
reading error available 2 1/2", 4", 6", 9", 12", 15", 18"
Thermowell: 24" standard lengths, available
Use of a thermowell is recommended when stemSensing Element: in stem lengths up to 72" long
or bulb would be exposed to pressure, corrosive Bimetallic Coil Connection:
fluid or high velocity media. Window: Thread.....1/2", 3/8", 1/4" NPT
Use of a thermowell permits calibration check Plain Glass-standard standard, JIS, DIN , M14*1.0
without interrupting or shutting the process. Tempered safety, Polycarbonate and M20*1.5 available
or laminated safety glass-optional Plain
Thermowells are available in various styles, Male swivel nut
connections, materials and sizes. Please Sliding male swivel nut
Weatherproof: Female swivel nut
refer to HAWK Thermowell catalogs for NEMA 4X/IP65 enclosure as per Sliding female swivel nut
detailed informations. IEC 529 UNI 8896
Pressure Range:
o o o o
Single Scale F Single Scale C Dual Scale C& F
Code Dial Range Code Dial Range Code Dial Range
o o o o
H1 -100/+100 F H14 -50/+100 C H32 -50/+100 C&-58/+212 F
o o o o
H2 -80/+120 F H15 -50/+50 C H33 -50/+50 C&-58/+122 F
o o o o
H3 -40/+160 F H16 -20/+120 C H34 -20/+120 C&-4/+248 F
o o o o
H4 -20/+120 F H17 -20/+80 C H35 -20/+80 C&-4/+176 F
o o o o
H5 0/+200 F H18 -20/+40 C H36 -20/+40 C&-4/+104 F
o o o o
H6 0/+250 F H19 0/+50 C H37 0/+50 C&32/+122
C F
o o o o
H7 50/300 F H20 0/+60 C H38 0/+60 C&32/+140 F
o o o o
H8 50/400 F H21 0/+80 C H39 0/+80 C&32/+176 F
o o o o
H9 50/500 F H22 0/+100 C H40 0/+100 C&32/+212 F
o o o o
H10 50/550 F H23 0/+120 C H41 0/+120 C&32/+248 F
o o o o
H11 150/750 F H24 0/+150 C H42 0/+150 C&32/+302 F
o o o o
H12 100/800 F H25 0/+200 C H43 0/+200 C&32/+392 F
o o o o
H13 200/1000 F H26 0/+250 C H44 0/+250 C&32/+482 F
o o o
H27 0/+300 C H45 0/+300 C&32/+572 F
o o o
H28 0/+400 C H46 0/+400 C&32/+752 F
o o o
H29 0/+450 C H47 0/+450 C&32/+842 F
o o o
H30 0/+500 C H48 0/+500 C&32/+932 F
o
H31 100/+550 C H49 100/+550 o C&212/+1022 o F
SIZE A B C D S
2.28" 2.68" 0.87" 2 1/2"(63mm), 4"(100mm),
2 1/2"(63mm) (58mm) (68mm) (22mm) 6"(150mm), 9"(225mm),
2.76" 3.31" 1.34" 1/4" to 3/8" 12"(300mm), 15"(380mm),
3"(80mm) (70mm) (84mm) (34mm) 18"(450mm), 24"(600mm)
4.16" 4.65" 1.46" 6mm, up to 72" are standard stem
4"(100mm) (102mm) (118mm) (37mm) 6.35mm, lengths. The other stem
4.53" 1.30" 8mm, lengths are available on
5.16"
5"(125mm) (115mm) (131mm) (33mm) 10mm request.
5.12" 6.26" 1.65"
6"(150mm) (140mm) (159mm) (42mm)
SW - 316 stainless
steel wetted parts
SC - 316 stainless
steel case and ring
A). The product has not been subjected to misuse, neglect, abuse , accident, incorrect mounting, improper use or
misapplication such as negligence, accident, vandalism, shock or vibration.
B). The performance of any system of which HAWK's products are a component part.
C). The product has not been exposed to any other service, range or environment of greater severity than that for
which the products were designed.
D). The product has not been altered or repaired by anyone except HAWK GAUGE or its authorized service agencies.
E). The serial number or date code has not been removed, defaced or changed.
F). The actual pressure&temperature occurring exceed the values specified for HAWK Thermometer
Unless otherwise specified in a manual or warranty card, or agree to in a writing signed by HAWK GAUGE office,
HAWK Thermometer products shall be warranted for one years from the date of sale.
This warranty is in lieu of all other warranties expressed or implied, and of all obligations or liabilities on its part for
damages including but not limited to consequential damages, following the use of misuse of instruments sold by it.
No agent is authorized to assume for it any liability except as set forth above.
Note:
HAWK GAUGE CO.,LTD reserves the right to make product improvements and change its specifications at any time
stated throughout this brochure without notification. Please contact the factory on all critical dimensions and
specifications for verification.
HAWK GAUGE is not expert in the customer's technical field and therefore doesn't warrant suitability of it's product
for the application selected by customer.
HAWK
Pressure Temperature Level Flow