SALIENT FEATURES

● Suitable for conductive liquids


● Maintenance free
● Full bore type
● Local Indication through LCD
● Simple & cost effective construction
● Empty pipe indication
● Material option depending upon process data
● Universal Power Supply 90 to 260V AC Optional 24V DC
● Communication port (Optional)
● HART Communication

DESCRIPTION
\\ELMAG-200 are micro-controller
controller based full bore type electromagnetic flow
ow meters specially used
for various industrial applications. These flow meters accurately measure the flow rate of conductive liquid & slurries in closed
pipes. Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of
conventional mechanical flow measuring device. The use of ‘ Pulsed DC’ technology offers highest ability & better measuring
accuracy in the form of electrical signal 4 - 20mA DC linearly proportional to volumetric flow. The instrument is based on
Faraday’s law of electro-magnetic
netic induction. A magnetic field is generated by the instrument in the flow tube. The
fluid flowing through this magnetic field eld generates a voltage that is proportional tto the flow
ow velocity. Corresponding
electrical output is provided
ided with respect to measuring flow range.

TECHNICAL SPECIFICATIONS
Media : Liquids (Conductive)
Conductivity : > 5 µs/cm
Viscosity : 200 cp max
Line Size : 15 NB to 600 NB
Excitation : Pulsed DC
Type of Output : 1) 4 to 20 mA DC, Isolated, HART
2) Pulse
Display : 16 x 2 LCD - 4 digit for Flow Rate & 8 digit for Totalised Flow
Engineering Unit : User Programmable (m³ /hr by default)
Calibration Range : As per requirement (Factory Calibrated for std. 2m/s velocity)
Accuracy : +/- 0.5% of F. S. (for 20 to 100% flow )
Linearity : +/- 0.5% of F. S.
Repeatability +/- 0.2% of F. S.
Temperature Coeffcient : +/- 0.05% per °C
Process Temperature : 85° C max for Rubber Lining & 120°C for PTFE Lining
Process Pressure : 10 kg/cm² max (higher on request)
Material of construction : Lining - Rubber (5mm +/-1mm thick) / PTFE (Teflon) (3mm +/-1mm+/ thick)
Flange - CS / MS / SS
Electrode - SS 316L / Hastalloy C / Platinum
Coil Housing - MS / SS 304
Power Supply : Option 1 : 24 V DC
Option 2 : 90 - 260 V AC, 50 Hz
Power Consumption : < 10 VA
Isolation : 1.4 KV between Input, Output & Power Supply
Response Time : < 1 Sec
Transmitter Enclosure : Die cast Aluminium IP 66, flow tube IP 68
Process Connections : ASA 150 flanged, as per table B 16.5
Mounting : In-Line
Line Horizontal (Vertical on request)
Operating Conditions : Temperature 0 to 55°C / Humidity 5 to 95% non condensing
Note :- For process conditions other than above please consult factory.
OPTIONAL
Communication Port : 1) RS 485 supporting MODBUS RTU Protocol
2) GSM Commun
Communication
3) 4-20mA
20mA with HART
Electronics : Remote Electronics

CAT/ELMAG-200-R1 Page 1 of 2
DIMENSIONAL DETAILS
Meter OD W H FD Flow Range (m³ /hr)
FLOW NOMOGRAPH
EL A --2
EM
L MAGG 20000MH
Size (mm) (mm) (mm) (mm) Min Normal Max

250
EL EEC
LE
TCRTO
RMOA
MGAG
NNEETTIIC
CFFLLOOW
WMM
E TEETRER
15 NB 88.9 100 180 200 0.03 1.2723 6.4
P
mm
P

EL EC T R ON ET
20 NB 98.4 100 180 200 0.11 2.2619 11
25 NB 107.9 100 180 200 0.18 3.5341 18
32 NB 117.5 100 210 200 0.29 5.7906 29
40 NB 127.0 100 210 200 0.45 9.05 45
50 NB 152.4 100 210 200 0.71 14.14 71
H MOD E L :
EL ECT RON ET

65 NB 177.8 100 220 200 1.19 23.892 119


SR. N O :

80 NB 190.5 100 240 200 1.81 36.19 181


W 100 NB 228.5 150 274 250 2.83 56.55 283
FD
125 NB 254.0 175 300 250 4.42 88.35 442
150 NB 279.4 175 330 300 6.36 127.23 636
200 NB 342.9 175 390 350 11.3 226.18 1130
250 NB 406.4 244 440 450 17.66 353.41 1766
300 NB 482.6 250 520 500 25.43 508.91 2543
350 NB 533.4 250 520 550 34.62 692.68 3462
400 NB 596.9 250 520 600 45.22 904.72 4522 Note :
450 NB 635.0 623 632 698 57.23 1145.04 5723 • Typical mounting dimensions for
reference
500 NB 698.5 623 686 768 70.65 1413.63 7065
• Standard factory calibration for 0 to
600 NB 812.8 818 772 918 101.74 2035.63 10174 2m/Sec velocity
• Max. Flow range in LPH / LPM is upto
OD : Flange Diameter W : Coil Housing width 9999
H : Coil Housing Height FD : Flange to Flange distance
OD
• Flow meter should be selected with the
help of Nomograph recommended full
scale velocity
INSTALLATION DRAWING
Pipe Support Pipe Support
Valve Valve

Flow In Flow Out

A-G -
EELLMMAG 20
2 00H
0M

ELEECL ETCRTORMOAMG
AGNNEETTIICC
FF LLOOWWMMETEETRER

P
P

Pipe Support 10D 5D


Valve

MO D E L :
EL EC T R ON ET
NO :

ORDERING INFORMATION

08 Other 04 All
08 Other 03 SS316 03 SS316 03 Platinum 03
4-20mA
09 None 03 25 mtr.
+ HART
4-20mA
15 mm to R Remote 02 Rubber 02 SS304 02 SS 304 02 Hyst C 02 SS304 02 + Pulse 02 230V AC 02 GSM 02 10 mtr. 02 None
600 mm
L Local 01 PTFE 01 CS / MS 01 MS 01 SS 316L 01 Aluminium 01 4-20 mA 01 24V DC 01 RS 485 01 5 mtr. 01 Datalogger
Lining Flange Coil Electrode Electronics Power Communi- Remote
SERIES Line Size Electronics Output Data logging
Material Housing Material Enclosure Supply cation Port Cable Length
ELMAG-200 65 mm L/R A 02 B 01 C 01 D 01 E 01 F 01 G 02 H 01 I 02 J 02
*Due to our continuous product revisions, Design, Speci‹cations and Model Number are subject to change without notice.
*Accuracy de‹ned at lab conditions.
Note : GSM output is without SIM card & SCADA viewing software.
Consult Factory

Va lve Au to m a ti on & Co n tr ol Te ch no lo gy
g lo b v a lv e

P roc e s s C ontrols

IN ST R U M EN T S & SYST EM S .,
3 0 , M o h a b b e w a la , In d u s tria l Are a , D e h ra d u n ,
U tta ra k h a n d -2 4 8 0 0 2 ,IN D IA .
Te l: +9 1 -9 7 2 0 8 7 0 8 7 0 | F a x : +9 1 -1 3 5 -2 6 4 4 0 9 7
Em a il: s a le s @ in s tru m e n ts -s y s te m s .c o m | in fo @ in s tru m e n ts -s y s te m s .c o m
W e b : w w w.in s tru m e n ts -s y s te m s .in

CAT/ELMAG-200-R1 Page 2 of 2

You might also like