18" Red-I65™ at 24" O.c.: This Product Meets or Exceeds The Set Design Controls For The Application and Loads Listed

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Project: Project Type: RJ3

Location:
Folder: Folder
Date: 6/13/18 8:17 AM
RedSpec™ by RedBuilt™ Designer: BN
v7.1.4 Comment:

18" Red-I65™ @ 24" o.c.


This product meets or exceeds the set design controls for the application and loads listed

DESIGN CONTROLS % Design Allow. DOL Combination Pattern Pass/Fail


Shear (lb) 19% 721 3850 Roof(125%) 1.0D+1.0Lr Adjacent First Support PASS
Positive Moment (ft-lb) 32% 4133 12975 Roof(125%) 1.0D+1.0Lr Even Members PASS
Negative Moment (ft-lb) 6% -749 12975 Roof(125%) 1.0D+1.0Lr All Spans PASS

DEFLECTIONS (in) % Design Allow. Design Allow. Combination Pattern Pass/Fail


Span Live 18% 0.199 1.100 L / 999+ L / 240 1.0D+1.0Lr Even Members PASS
Span Total 23% 0.339 1.467 L / 778 L / 180 1.0D+1.0Lr Even Members PASS
Overhang Live (down) 8% 0.036 0.450 2L / 999+ 2L / 240 1.0D+1.0Lr Odd Members PASS
Overhang Total (down) 0.000 0.600 2L / 999+ 2L / 180 1.0D+1.0Lr PASS
Overhang Live (up) -0.114 2L / 943
Overhang Total (up) -0.181 2L / 595

SUPPORTS Support 1 Support 2


Live Reaction, Critical (lb) (DOL%) 638 (125) 638 (125)
Dead Reaction (lb) 527 527
Total Reaction (lb) (DOL%) 1165 (125) 1165 (125)
Bearing Bottom Bottom
Support Wall Wall
Req'd Bearing, No Stiffeners (in) 3.50 3.50
Req'd Bearing, Stiffeners (in) - -

SPANS AND LOADS


Dimensions represent horizontal design spans. Member Slope: 0/12

4'- 6.0" 22'- 0.0" 4'- 6.0"

APPLICATION LOADS
Type Units DOL Live Dead Partition Tributary Member Type
Uniform psf Roof(125%) 20 15 0 24" Roof Joist

ADDITIONAL LOADS
Type Units DOL Live Dead Location from left Application Comment
Uniform psf Roof(125%) 20 17 0'-0.0" to 31'-0.0" Replaces Roof Dead Loads and Live Loads

NOTES
• Building code and design methodology: 2015 IBC ASD (US).
• Continuous lateral support required at top edge. Lateral support at bottom edge shall be per RedBuilt recommendations.

C:\Users\bNguyen.BNSE\Desktop\TJI- Wood Joist\TJI-WoodJoist.red

6/13/2018 8:17:09 AM Project : Folder : RJ3 Page 1 of 1

The products noted are intended for interior, untreated, non-corrosive applications with normal temperatures and dry conditions of use, and must be installed
in accordance with local building code requirements and RedBuilt™ recommendations. The loads, spans, and spacing have been provided by others and must
be approved for the specific application by the design professional for the project. Unless otherwise noted, this output has not been reviewed by a RedBuilt™