Testing & Commisioning FM200

SELA PASS TESTING AND commissioning procedure for fire 'uppressioJf system (FM-200) we will be read_v to start TESTING AND. Commissioning 01 Tuesday 0410112011. Please cOffirm by return for the above date and make the site ready / or that.

Uploaded by

Danish Khan
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views8 pages

Testing & Commisioning FM200

SELA PASS TESTING AND commissioning procedure for fire 'uppressioJf system (FM-200) we will be read_v to start TESTING AND. Commissioning 01 Tuesday 0410112011. Please cOffirm by return for the above date and make the site ready / or that.

Uploaded by

Danish Khan
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8
02/01 2011 10:08 FAX 0242572820 Sela for Power, Automation & Safety Systems (Sela - PASS) SELA PASS: Si oor Aanhita AS pit Aa dLuly eSaciNly cg all Aas (why - A Lue) Facsimile Message ‘To MIS: | Sharyuwi Co. Eng. Saleem Akhtar Ws Date: |2" San, 2014 From: | Eng. Muhammad Sabti WA (02)639-0124 Ext. 270 (09639-0511 050-311-2283 Our Ref.: | NOOGOSFF-0ST. Email: | £[email protected] Al khalidya Palace Clinic - Jeddah Dear Sir, With reference to the above mentioned TESTING AND COMMISSIONING PROCEDURE =) subject, we are submitting the testing and commissioning procedure for fire suppression system (FM-200). Riya Oc Te (01) 400899 4420110 Fax (01) 4634430 We will be ready to start testing and commissioning on Tuesday 04/01/2011. Please confirm by return for the above date and make the site ready for that. Sincerely Yours, Sela- PASS (Power, Automation & Safety Systems). Muhammad. System Engineer Tel (02)-691-5777 Ext.163 Faxit (02)-257-2320, Mobb (050-458-4321 o > (yer ya (7) sere (apenas Oa} eat es algal 1) OST as OD) ITED AlKhabar TL (03) 8678233 /R67H244 Fa (3) 678266, “Macina= Tel./Fax: (04 286049 ‘ingdecx of Sandi Acabia www selanet.com (or) nts (WATE /ANWANTTVe pel (A) Armee thyaga + pat “aia Aa 02/01 2011 10:08 Fax 02+2572520 SELA PASS: ooz Sans TESTING AND COMMISSIONING ‘Hient Name: Sharqawi Co. Pies Ae Poe Cnc sh ak course Hoos ‘Sustem Type; SIEMENS HFC-227¢a (FM-200) Fire Suppression Systems. Location Ni TESTING & COMMISSIONING (Reference: NFPA 200, ton 2008) MECHANICAL COMPONENTS: in accordance with Syetem Design 2 _|Nezzle Pert Number in accordance with system Design {3 [Plea edicton conten o System Design 4 [Phelan and Nazis securely anor, $ [Discharge Nozzles installed in optimal Agent Dispersal 6 _|Agent Storage Containers mounted securely by Brackets. JAgent Storage Containers are in accordance with System| 7 [Design 7 Piping oneumatcally leak tested in acoordanoe with NFPA {2001 (2008 Ecition). Sec. 7.7.2.2.12" The Piping shall be 3 |Pneumatcally tested in a closed circul for a period of 10 |minutes at 40 ps (278 KPa). Al the end of 10 minutes, the Jpressure drop shall not exceed 20 percent ofthe test pressure |Fiow test pertormed in accordance with NFPA 2001 (2008 tition). Sec. 7.7.2.2.18°A flow test using nitrogen or an 9 inert gas shall be performed on the piping network to venty that fow is continuous and that tne piping and nazzies ere lunobstructes,” Room enclosure of any significant air ieakage sealed 10 tightly with fre resistant sealant. (nat under our Scope ~ by client, I Date of Testing & re Commissioning — Page 1 02/01 2011 10:08 FAX 0242572520 SELA PASS: ro0s mews TESTING AND COMMISSi ‘ent Nara: Sharqawi Co, fs Proieet Name: A-ehaliya Place Cie Jeddah Contract No. 10060s¢ ‘Swstern Type: SIEMENS HFC-227ea (FM-200) Fire Suppression Systems, Location Name: 4 [Wiring system property installed in compliance with focal lcodes, 2 [Field circuits free of ground fauts and short ccuts. [Power to contro! panels supplied from a separate circuit breakers. 4 [24-hour stanciby power provides for operation, |Smoke/heat detectors installed in proper locations, not [obstructed or near air vertlation end cooling equipment, [Smoke/hest setectors installed in accordance with [technica data regarding instalation, Naual aera waka opeY RRS aay 7 accesible prose tertod one pleted sonnet semage - ~ ans poacase daw having he spun ne itn! won eon aa ropary Leon 2 {Abort switch property installed and clearty ientited, |Manual agent release stations shall aways override abort witches, 11. |Contrl paneis propery installed and clearly identifi, Satitacinny NS Net Salstaciony Date of Testing & Commissioning Signatur Pagez 02/01 2011 10:07 FAK 0242872320 SELA PASS seoass TING Al MMISSIONING ‘lignt Warne; Shargawi Co. Project Name: Al-thaliiya Palace Clinic Jeddah Contract No: S0060SFF ‘Suatem Type: SIEMENS H1FC-227ea (FM-200) Fire Suppression Systems Lgcation Name: woos [Check each detector at Zone 1 [Check each detector at Zone 2, [Check all end-otsine resistors installed across al devices, (Check ait supervised circuits for proper trouble response. Test: |Operate detection initiating circuits, Very alarm function Joceurs Operate the necessary crcut to intiate a second alarm [srouit. Verfy second alarm funetien occurs |Operate manual release, Verity manval release function Joccurs [Operate abor switch circut. Ven abor function occa [Confirm visual end auctbe supervisory signals are received atthe control panel [Test automatic vaives proper operation, 6 |Check preumatic valve actuator proper operation. Note: S~ Sststaciony NS — nol Satetactony Page 3 Se ewe, 2. ae: ame Congany vention | SREOTSGE Tyme 1 z 3 Fi 02/01 2011 10:07 FAX 0242872320 SELA PASS oos TESTING AND COMMISSIONING ‘Aen tne Shrgpet s/s bates Atay tbe Ginsedah Come nome System Type; SIEMENS H1FC-227ea (FM-200) Fire Suppression ‘Systems, a Very control panel is connected to dedicated source, [Testa primary power failure. System to operate an stancty| 2 loomer. [Overall Remarks: ~ “Return of System to Operational Conditio 1. [Reconnect each agent container. 2 [Test completed. System returned to full service condition. Note: S—Saisiaciowy NS Nol Saletactory Jee me ime company Poaon | Set Teta Signature Pages 02/01 2011 10:08 FAX 0242572520 SELA PASS Bove TESTING AND COMMISSIONING ‘at ame: Saran Gs 4@ Poi Nan: A tela Fae Ch cana Na acest Sar Tea: SHEEN HFC 2705 (F200) re Suppresion tee Location Name: Jeddah 1 {Allopen ends of the pipes natwork are closed. 2 [Check ail pipes, fitings, Hangers, supports are installed [eropery, [Connect a dummy nitrogen cylinderiair compressor wit] Jpressure gauge 0-60 psi using a veducer and coupling, |Alow the pressure to reach visto 40 ps inthe entire piping network stan Time Iria Prossure: 5. [Maintain he pressure for 10 minutes, 8 Check the pressure reading in the gauge eer 10 minutes. End Time: Final Pressure: 7 heck whether the pressure is more or equal to 32 psi Note: S-Sadsfacioy _NS-Not Sallsfactory |Overall Remarks : Fe Dato of Testing & -Commisioning, signature SELA PASS Boor TESTING AND COMMISSIONING ‘ena, sharvew Co ys ttle Aan asta Pale Cn déah onsale: aosostt tea ie: SIEMENS C227 (4M. Supresion Sper ate ra f diiecedire ee 4 {Check ail pipes, stings, Hangers, supports are installed} Propesty. 2. {Connect a dummy nitrogen cylincerir compressor using ¢| reducer ana coupling. 3 [Oneck all nazzies whether the nittogm get out from each. |Quantity of Nozees: Pcs, INote:S~ Satisfactory NS Not Satisfactory [Overall Remarks : Pages 02/01 2011 10:09 Fax 0242872320 SELA PASS oos Sa See a Sere TESTING AND COMMISSIONING ‘ent Name; Shara Co. tly Pret Rare: Ait aloe Ci doh commas: 00st System Tne SIEMENS HEC 227s (F620) re Supression yes \ocaionnome = ee Pipes size in accordance with System Dasign INowe, Sprinkler & Hose Cabinets Pat Number Tn 2 |sccordance wih system Design, "y [Pie Sze reducion conforms fo Syatem Design.” _ 7 [Pibe ins and Nezzies scarey Taster: - ig _ [Pre lose Cabinets re in accordance wih System Dear Piping preumaticaly 1esk tesied in accordance wih NFPA }13. The Piping shall be Pressurized fora period of 24 © [hours at 200 psiThe pressure drop shell not exceed 20 Jpercent of the test pressure. ing the Test and Dra 7 \Waives. [Check the enough flow and pressure from the fire hose] 8 [cabinets, [Check the water spray system by opening the Deluga| [vaives. Date of Testing & Nome ‘company Position es Page?