Tank General Information Circumference Information (Millimeter)
Tank General Information Circumference Information (Millimeter)
Plate Arrangement
Amount/Descripti
Shell Thickness
Measurement
Ring No.
method
1 (%)
(mm)
Unit
on
Title
Dou
L/
H/D
D/D
Qua
ntity
t/d/Z
DFB
in
1
:
1- The information in the table on the previous page is available for a cylindrical tank at the time of
calibration (the mentioned environments are related to the calibration time and after applying
corrections to the strapping method).
Now, after two months from the time of calibration to obtain the tank inventory, the number read on the
dip tape is 3.217 meters and the temperature of the fluid and the environment are 22 and 24
degrees Celsius, respectively. Calculate the tank inventory at 60 °F (by writing the calculations and formulas
used in full).
2- The empty spherical tank is calibrated at a temperature of 20 °C, the equatorial medium and its two
semiconductor environments at this temperature are 20.103, 20.121 and 20.115, respectively. If the
height of the pole to the pole of the tank at this temperature is 6.39 meters, it is desirable to calculate the
enclosed volume from a height of 3.4 to 3.42 meters at a temperature of 60 °F.