Vision Turbine Meters
Vision Turbine Meters
Vision Turbine Meters
Nürtinger Str. 76
72639 Neuffen (Germany)
Tel. +49-7025-9208-0
Fax +49-7025-9208-15
www.badgermeter.de
[email protected]
Description Applications
The liquid turbine meters of the series Vision are for the For flow measurement of water, demineralized water,
exact measuring of small quantities of liquids. The actual alkaline solutions, oils/edible oils, fuel/fuel consumption,
flow as well as the already passed flow can be measured. fuel oil, beverage, water based liquids, etc.
The large number of pulses gives a good resolution. As the Special for washmaschines, dish washers, coffee
mass of the turbine are very small the response time is machines, laser cooling plants, solar solutions, backery
very short. It is not necessary to install a straight length of machines, steam cooking machines in large kitchen plants,
pipeline at the upstream side. The simple mechanical dialysis equipment, CD cleaning, irrigation plants, etc.
construction of the sensor Vision guarantees a long lifespan
without any loss of accuracy. Pressure surges do not affect
the measuring system. Electrical connections
Measuring principle
The rotor is turned by the fluid force in proportional to the
flow. A hall generator supplies pulses, which can be util-
ized for digital or analogue signal processing. The gener- with 3 flat plugs with AMP Faston connection
ated pulses are specified as the k-factor. 2,8 x 0,5 mm 2,8/6,3 x 0,8 mm
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
Technical data
Type 1005 2F66 2006 2F66 2006 4F44 2008 2F66
Material Trogamid
Connection* G 1/4" G 3/8"
Order code (with coupler
56547-163-2F66 56510-163-2F66 56510-163-4F44 56500-163-2F66
socket acc. EN 60529)
Order code for AMP Faston - 56510-164-2F66 56510-164-4F44 56500-164-2F66
Order code for 1m-cable 56547-165-2F66-1 56510-165-2F66-1 56510-165-4F44-1 56500-165-2F66-1
Measuring rate l/min 0,1 – 2,5 0,5 - 5 1 – 10 0,5 – 7,5
K-factor PPL 22.000 6900 3300 4700
DN mm 5 6 6 8
Type 2008 4F44 2008 4F22 2008 4F17 3012 4F16
Material Trogamid
Connection* G 3/8" G 3/4"
Order code (with coupler
56500-163-4F44 56500-163-4F22 56500-163-4F17 56422-163-4F16
socket acc. EN 60529)
Order code for AMP Faston 56500-164-4F44 56500-164-4F22 56500-164-4F17 -
Order code for 1m-cable 56500-165-4F44-1 56500-165-4F22-1 56500-165-4F17-1 56422-165-4F16-1
Measuring rate l/min 1 - 15 1 – 25 2 – 35 5 – 65
K-factor PPL 2200 1000 750 210
DN mm 8 8 8 12
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
Type 1005 2F66 2006 2F66 2006 4F44 2008 2F66 2008 4F44 2008 4F22 2008 4F17 3012 4F16
Measuring rate l/min 0.1 – 2.5 0,5 – 5 1 – 10 0,50 – 7,5 1 – 15 1 – 25 2 – 35 5 – 65
K-factor PPL* 22.000 6900 3300 4700 2200 1000 750 210
Size mm 5 6 6 8 8 8 8 12
Viscosity range 0.8 - 16 mm²/sec (mpas)
Accuracy +/- 3% of value
Repeatability Better than 0.5%
Temperature range -20 up to +100 °C
Operating pressure 25 bar max
Burst pressure 200 bar ~100 bar
Electrical connection ** - AMP Faston 2.8/6.3 x 0.8 mmm
- Connection MICRO-EN 60529 and 3 flat plugs 2.8 x 0.5 mm (point plate)
- Cable connection: round cable 3xAWG 24 with free cable end
Filter 20 to 40 micron recommended
Power supply 5 - 24 VDC.
Current consumption Ca. 8 mA.
Output signal Pulses by open collector (NPN sinking).
Output current Max. 20 mA.
Pull-up resistor 1 - 2.2 kOhm
* PPL = Pulses per liter
** DIN connector MICRO EN60529
Display operation
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
Dimensions (in mm)
(+)Red
5-24 VDC
(-)Black
0 VDC
(Ω)Brown
Output
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
Example Vision 2000 with round cable 3 x AWG 24 and hose nipple
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
Displays for the VISION series
The ILR 701T, 750T series electronic register
Features
• Large six digit LCD display
• Display in liters, pints, quarts or gallons, freely pro-
grammable
• 11 digits, non-resettable lifetime totalizer and 6 digits,
resettable totalizer
• Temperature range: -20 °C to +80 °C
(-4 °F to +140 °F)
• Calibration factor saved in non-volatile memory
• 9 point linearization (ILR 750T, ILR 701T)
• Scalable pulse output and 4-20 mA output (ILR 750)
• Protection class IP65
Description
the batch totalization or the flow rate of the fluid going
The electronic register module contains a microprocessor board
through the meter on the 6-digit display.
powered by a lithium battery. It can be programmed to batch
The registers batch totalizer is a 6-digit display with three
in liters, pints, quarts, or gallons and will totalize in liters or
places of resolution after the decimal point. If the total
gallons. A calibration factor and unit of measure are
dispensed exceeds 999.999 then the display will shift and
programmed during factory test. Unlike mechanical registers,
only 2 digits will be displayed after the decimal point,
these units can be electronically recalibrated in the field when
9999.99 and will continue to shift to the maximum value of
necessary. A 6-digit LC display, accurate to three decimal
999999. After reaching 999999 the batch totalizer will
places, shows the exact amount of fluid that has passed
rollover to 0.000. The batch totalizer is reset to zero when
through the meter. The entire register module is protected
the reset button is depressed.
from normal wear and tear by a rugged, shock resistant
housing. The register also has a resettable totalizer that requires
that the total and reset button both be depressed to reset
Operation (hold the “Total” button, then press the “Reset” button to
Tubine meters have hall sensors that cause the turbine to send reset this totalizer while resettable totalize is displayed).
pulses to the register as rotates. This would be used for multiple batch totalization purposes.
The register is in a sleep mode until it detects these pulses
caused by fluid going through the meter. The micro-processor The register´s life time totalizer is 11 digits and will either
in the register then measures the flow and will display either be in gallons or liters based on the unit of measure
selected. Pushing and holding the total button while the
life time totalizer is displayed will display the full 11-digit
life time totalizer value.
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
The electronic displays are available in two versions
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .
Example Vision 3000 with built up display
TRANSMITTER
Wireless system consisting of transmitter and receiver (shown here the transmitter on the Vision 3000)
RECEIVER
Wireless system consisting of transmitter and receiver (shown here the receiver)
TUR_VIS_BR_DB_02_1704.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted .