General Characteristics: 3029TFS29 G3
General Characteristics: 3029TFS29 G3
General Characteristics: 3029TFS29 G3
GENERAL CHARACTERISTICS
Frequency (Hz) 60 Hz
Voltage (V) 480/277
Standard Control Panel APM303
Optional control panel TELYS
Optional Control Panel M80
Optional control panel NA
POWER
ESP PRP
Voltage Standby Amps
kWe kVA kWe kVA
480/277 40 50 36 45 60
440/254 40 50 36 45 66
DESCRIPTIVE 220/127 40 50 36 45 131
Mechanic governor 208/120 37 46 34 42 128
Mechanically welded chassis with antivibration
suspension
Main line circuit breaker DIMENSIONS COMPACT VERSION
Radiator for core temperature of 48/50°C max with Length (mm) 1700
mechanical fan Width (mm) 896
Protective grille for fan and rotating parts (CE option)
Height (mm) 1221
9 dB(A) silencer supplied separately
Dry weight (kg) 820
Charger DC starting battery with electrolyte
12 V charge alternator and starter Tank capacity (L) 100
Delivered with oil and coolant -30°C
Manual for use and installation DIMENSIONS SOUNDPROOFED VERSION
Type soundproofing M127
Length (mm) 2080
Width (mm) 960
Height (mm) 1415
Dry weight (kg) 1040
POWER DEFINITION
PRP : Prime Power is available for an unlimited number of annual Tank capacity (L) 100
operating hours in variable load applications, in accordance with ISO
8528-1. ESP : The standby power rating is applicable for supplying
Acoustic pressure level @1m in dB(A) 77
emergency power in variable load applications in accordance with ISO Guaranteed acoustic power level (Lwa)
8528-1. Overload is not allowed.
Acoustic pressure level @7m in dB(A) 67
TERMS OF USE
According to the standard, the nominal power assigned by the genset is
given for 25°C Air Intlet Temperature, of a barometric pressure of 100
kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions
in your installation, refer to the derating table.
ASSOCIATED UNCERTAINTY
For the generating sets used indoor, where the acoustic pressure levels
depends on the installation conditions, it is not possible to specify the
ambient noise level in the exploitation and maintenance instructions .
You will also find in our exploitation and maintenance instructions a
warning concerning the air noise dangers and the need to implement
appropriated preventive measures.
04/04/2019
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
J40U
ENGINE CHARACTERISTICS
EMISSIONS
Emission PM (g/kWh)
Emission CO (g/kW.h)
Emission HC+NOx (g/kWh) 0
Emission HC (g/kW.h)
04/04/2019
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
J40U
ALTERNATOR CHARACTERISTICS
DIMENSIONS
Dimensions soundproofed version Dimensions DW compact version
Type soundproofing M127 Type soundproofing
Length (mm) 2080 Length (mm) 2160
Width (mm) 960 Width (mm) 966
Height (mm) 1415 Height (mm) 1388
Dry weight (kg) 1040 Dry weight (kg) 1002
Tank capacity (L) 100 Tank capacity (L) 230
Acoustic pressure level @1m in dB(A) 77 Acoustic pressure level @1m in dB(A)
Guaranteed acoustic power level (Lwa) Guaranteed acoustic power level (Lwa)
Acoustic pressure level @7m in dB(A) 67 Acoustic pressure level @7m in dB(A)
Dimensions DW soundproofed version Dimensions DW 48h soundproofed version
Type soundproofing M127 DW Type soundproofing M127 DW48
Length (mm) 2160 Length (mm) 2160
Width (mm) 966 Width (mm) 966
Height (mm) 1582 Height (mm) 1631
Dry weight (kg) 1210 %PdnetE_5% 1215
Tank capacity (L) 230 Tank capacity (L) 420
Acoustic pressure level @1m in dB(A) 77 Acoustic pressure level @1m in dB(A) 76
04/04/2019
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
Guaranteed acoustic power level (Lwa) Guaranteed acoustic power level (Lwa)
Acoustic pressure level @7m in dB(A) 67 Acoustic pressure level @7m in dB(A) 66
04/04/2019
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
J40U
CONTROL PANEL
04/04/2019
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
M80, transfer of information Basic terminal block
The M80 is a dual-function control unit. It can be used as a The control unit can be used as a basic terminal block for
basic terminal block for connecting a control box and as an connecting a control box.
instrument panel with a direct read facility, with displays
giving a global view of your generating set's basic Offers the following functions:
parameters.
emergency stop button, customer connection terminal
Offers the following functions: block, CE.
04/04/2019
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.