Technical Report: Sharp Corporation
Technical Report: Sharp Corporation
16, 2013
Technical Report
2. Description: Diameter of CL brush roller has changed from φ18 to φ16. Cleaning performance of
Process unit improved by creating larger gap between CL brush roller and CL blade.
- CL brush roller
After After
Less tiers Less tiers
in this area in this area
A line has
been added
4. Parts Action:
Current parts New parts Inter-
Ref. Model Price Effective
Version P/G No. Q’ty Parts name change-
No. name rank time
Parts code Parts code ability
MX-M904
1 MX-M1054 ALL 36- NROLN1662FCZ2 NROLN1662FCZ3 BD 1 CL brush roller 2013/1 3
MX-M1204
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type. 5. Interchangeable if replaced with same types of
New type cannot be used in place of current type. related parts in use.
3. Current type cannot be used in place of new type.
6. Others.
New type can be used in place of current type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
1/1
SHARP CORPORATION Document Systems Division C