Background (1)
To do a single- Choose
YES YES laboratory validation ISO 16140-4
YES
NO
Apply method only in that particular
laboratory (incl. scope extension)
For use of the (food) type in a single laboratory, in the case of:
a] an alternative (proprietary) method validated according to ISO 16140-2 or
Choose
Choose b] a non-proprietary method validated according to ISO 16140-5 or
ISO 16140-4
ISO 16140-3 c] a reference method with performance characteristics or
AOAC Europe/NMKL Nordval symposium Oslo d] a reference method without performance characteristics
(verification)
6
4 June 2019
ISO 16140-2 (validation of alternative proprietary methods)
Definitions
› Validation: establishment of › Verification: demonstration
the performance that a validated method
characteristics of a method functions in the user’s hands
and provision of objective according to the method’s
evidence that the performance specifications determined in
requirements for a specified the validation study and is fit
intended use are fulfilled. for its purpose.
Quantitative Intralaboratory
reproducibility standard ✓ Not applicable
deviation (SIR)
Estimated LOD50
› Three protocols available.
Inoculation level of the test portion
Protocol 9 × LOD50 3 × LOD50 1 × LOD50 3 to 5 cfu Blank Total number of
/test /test /test /test replicates
portion portion portion portion
1 1 4 4 - 1 10
2 - 3 5 – 1 9
3 - - - 7 1 8
Estimated LOD50
› Criterium eLOD< 4 x LOD50 › Most alternative methods do
not have LOD50 data but
› Example for 3 dilutions
RLOD!
High inoculation Intermediate Low inoculation level Blank level eLOD50
level inoculation level
= 18 cfu/test = 6 cfu/test = 2 cfu/test portion cfu/test portion
portion portion
1/1 4/4 4/4 0/1 < 2,0
1/1 4/4 3/4 0/1 = 1,0
1/1 4/4 2/4 0/1 = 1,4
1/1 4/4 1/4 0/1 = 2,0
1/1 4/4 0/4 0/1 = 3,0
AOAC Europe/NMKL Nordval symposium Oslo 15
4 June 2019
ISO 16140-3 (method verification) (5)
Estimated bias (eBias)
› Criterium: eBias < 0,5 log
Mean result for batch Absolute difference in
log10 cfu/g results between
artificially
Artificially contaminated Inoculum suspension contaminated
(food) item [without (food) item] (food) item and the
inoculum suspension
Sample 1, 2,06
test portion 1 2,17 −0,11
(average of 1,87 and
Sample 1, 2,25)
test portion 2
Sample 2, 3,99
test portion 1 4,29 −0,30
(average of 3,93 and
Sample 2, 4,04)
Test portion 2
AOAC Europe/NMKL Nordval symposium Oslo 16
Sample
4 June 2019
3,
test portion 1 3,68
ISO 16140-3 (method verification) (6)
Intralab. Reproducibility (SIR)
› Link with ISO 19036 (2019)
› Is the technical uncertainty as
in ISO 19036
Questions????